DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Similar documents
ACRYLIC FLOW METERS 0-30, 0-70 & LPM

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

Operating and Maintenance Manual. Flowmeter

AND OPERATION INSTRUCTIONS

U S E R M A N U A L CAUTION. Models: 19MFA Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

UltraMaxO OXYGEN ANALYZER OPERATING MANUAL & INSTRUCTIONS FOR USE R221P11. R221M11 Rev. K

U S E R M A N U A L. (CGA 870 Connection)

USER MANUAL. AIR-OXYGEN BLENDER (DISS and NIST Connections) Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS

453 Series Steam Heated Vaporizing Regulator

RK-IR Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

UltraMaxO OXYGEN ANALYZER OPERATING MANUAL & INSTRUCTIONS FOR USE R221P11. R221M11 Rev. C

- GAS REGULATOR - COMPACT STYLE

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

Oxygen Dialflow Meter. Instructions for Use

RK LEL Sample Draw Aspirator Adapter Operator s Manual

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Portable Compressed CO 2 Regulator

Pressure Regulator. Instructions for Use

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

HomeFill II Oxygen Conserving Cylinder

CAL. Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE R218P12. R218M12 Rev. J

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

TactAir PCP Fill Kit/Adapter. Operation Manual

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

USER MANUAL SAVE THESE INSTRUCTIONS. Manuals available on our Website;

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

Model ASSEMBLY and OPERATING INSTRUCTIONS

Yoke Block Instruction Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Helium-Oxygen Blender

Micro Dial-Flowmeter. Instructions for Use

PORTER INSTRUMENT COMPANY, INC.

Yoke Block Instruction Manual

Dialflow Regulator. Instructions for Use

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

Offset head dual chuck

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

AIR INLINE METAL SHEAR

453 Series Steam Heated Vaporizing Regulator

U S E R M A N U A L. HELIUM-Oxygen Blender. (DISS and NIST Connections) Model No. PM5400 Series (shown) PM5500 Series SAVE THESE INSTRUCTIONS

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

1/2 Twin Hammer Composite. Air Impact Wrench ASSEMBLY AND OPERATING INSTRUCTIONS

IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS

Oxygen Dialflow Meter. Instructions for Use

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Rejuvenation Instructions

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

Certified ISO 9000 INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions

User Instruction Manual

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

Owner s Manual & Safety Instructions

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

623 Series Dome Load Regulators

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Instruction Manual No. 742, 8/98

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

User Operation Manual and Safety Instructions

4-in-1 Professional Inflator Kit

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

USER MANUAL Series (CGA 870 Connections) SAVE THESE INSTRUCTIONS

VAPOMATIC ANESTHETIC VAPORIZER

Cylinder Tilt Saddle Instruction Manual

MODEL CALIBRATION GAS DELIVERY SYSTEM

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

IMPORTANT SAFETY INFORMATION

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

INSTRUCTION MANUAL GAS TRAK

Vessel Installation and Operating Manual

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

USER MANUAL Series (Threaded Connections) SAVE THESE INSTRUCTIONS

45A, Armthorpe Road, Brampton, Ontario, Canada, L6T 5M4. Made in Canada by O-Two Medical Technologies Inc.

FLANGED TWO-PIECE BALL VALVES

MANIFLEX System. 52B Series 52C Series 52S Series INSTALLATION AND OPERATION INSTRUCTIONS

MACS Mask CPAP System

Flowmeters & Accessories Guide

Owner s Manual & Safety Instructions

J Air and Water Kit Instructions Part# 02584

Transcription:

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER) 0-3, 0-15, 0-30 & 0-70 LPM ASSEMBLY INSTRUCTIONS & INSTRUCTIONS FOR USE R219P87-400 (0-70 LPM) R219P88-400 (0-30 LPM) R219P79-400 (0-15 LPM) R219P99-400 (0-3 LPM) R219M01 Rev. A

TABLE OF CONTENTS 1.0 PRODUCT OVERVIEW...1 1.1 Description... 1 1.2 Intended Use... 1 1.3 Warnings... 1 1.4 Cautions... 2 2.0 PRODUCT SPECIFICATIONS... 3 2.1 Flow Ranges, Graduations & Accuracy... 3 2.2 Transport/Storage Requirements... 3 3.0 OPERATING INSTRUCTIONS... 4 3.1 General Operation... 4 4.0 TROUBLESHOOTING... 5 4.1 Troubleshooting Table:... 5 5.0 RECOMMENDED MAINTENANCE... 5 5.1 Cleaning Instructions... 5 6.0 WARRANTY... 6 7.0 SYMBOL GUIDE... 7 866.4.Maxtec www.maxtec.com III

1.0 PRODUCT OVERVIEW 1.1 Description Maxtec DFB flow meters are designed and calibrated to provide increased accuracy compared to standard flow meters, when used on air/oxygen blender outlets. By utilizing dual-scale graduations, the flow meters provide two flow meters in one for increased accuracy at lower flows. The flow meters feature high-quality acrylic block bodies and precision valves. Each flow meter comes equipped with a DISS outlet and DISS adapter for neat and compact attachment to the side of the blender. 1.2 Intended use The flow meter is intended for use as a secondary flow meter for an air/oxygen blender, such as the Maxtec MaxBlend 2, and is to be used by physicians, respiratory therapists and other authorized hospital personnel to administer selected doses of medical gases to a patient. 1.3 Warnings! This manual instructs a professional to install and operate the flow meter. This is provided for your safety and to prevent damage to the flow meter. If you do not understand this manual, DO NOT USE the flow meter and contact your provider. Use flow meters only for their Intended Use as described in this manual. ALWAYS confirm prescribed flow before administering to patient and monitor flow on a frequent basis. Flow meters may contain magnetic, ferrous material that may affect the results of an MRI. Read this User Manual before installing or operating the flow meter. To Reduce the Risk of Fire or Explosion: ALWAYS follow ANSI and CGA standards for Medical Gas Products and flow meters and Oxygen Handling. DO NOT use or store oils, greases, organic lubricants or any combustible materials on or near this Flow meter. Ћ Ћ DO NOT use near any type of flame or flammable/explosive substances, vapors or atmosphere. 866.4.Maxtec www.maxtec.com 1

ЋDO Ћ NOT connect to source pressure greater than 100 psi. DO NOT disassemble the flow meter while pressurized. ЋDO Ћ NOT smoke in an area where oxygen is being administered. 1.4 Cautions Use caution to avoid cross-threading fittings during installation. Always use a backing wrench when installing or removing connectors. Flow meters must be operated with the Flow Tube in a vertical, upright position. Only personnel instructed and trained in its use should operate this flow meter. Ensure all connections are tight and leak free. Only use oxygen-safe leak detector. Only trained medical professionals should operate the flow meter. DO NOT drop the flow meter. DO NOT autoclave. DO NOT gas sterilize with EtO (Ethylene Oxide). DO NOT clean with aromatic hydrocarbons. DO NOT immerse flow meter in any kind of liquid. This will void the warranty. DO NOT use if damaged. Inspect the flow meter for visual damage before each use. DO NOT over-tighten knob when turning off. This will cause damage to the flow meter. DO NOT over-tighten any threaded connectors; body may crack and cause leaks. The flow meter has been specifically calibrated for use on the outlet of an air/oxygen blender. The accuracy of the flow rates will be affected if the flow meter is used in any other way Gas temperatures other than 70 F (21 C) may affect the accuracy of the indicated flow. 2 866.4.Maxtec www.maxtec.com

Attaching accessories to the outlet (which may increase resistance to outlet flow) may change the indicated flow but will not affect the accuracy of the flow. 2.0 SPECIFICATIONS 2.1 Flow Range Accuracy Chart MODEL FLOW GRADUATIONS ACCURACY R219P99-400 0-3 LPM 0.1 (0.1-1) LPM 0.5 (1-3) LPM ± 0.5 LPM R219P79-400 0-15 LPM 0.25 (0.5-3) LPM 1 (5-15) LPM 0.5-3: ± 0.5 LPM 5-15: ± 10% of indicated value R219P88-400 0-30 LPM 0.25 (0.5-3) LPM 2.5 (5-30) LPM 0.5-3: ± 0.5 LPM 5-30: ± 10% of indicated value R219P87-400 0-70 LPM 1 (2-15) LPM 5 (15-70) LPM 2-4: ± 0.5 LPM 5-70: ± 10% of indicated value For the most current manual revision please visit our website: www.maxtec.com 2.2 Transport/Storage Requirements -40 F (-40 C) to 140 F (60 C) NOTE: Storage/transport outside the specified range may cause damage to the flow meter. The above flow meter models are calibrated for air/oxygen blenders at 70 F (21 C) and standard atmospheric pressure with inlet pressures at 50psi and 60% O 2. Specifications are subject to change without prior notice. 866.4.Maxtec www.maxtec.com 3

3.0 OPERATING INSTRUCTIONS 3.1 General Operation 1. Remove the air and oxygen line pressure to the air/oxygen blender and ensure the valve to the flow meter is closed. 2. Apply a thread sealant that is appropriate for medical oxygen use to the male NPT thread of the supplied 90 degree NPT to DISS adapter. 3. Use a backing-wrench to secure the female NPT fitting on the back of the flow meter while hand-tightening the male NPT thread of the 90 degree NPT to DISS adapter into the female NPT fitting. 4. With the backing-wrench still in place, tighten the 90 degree NPT to DISS adapter fitting at least one full revolution. Continue to tighten the fitting until it is aligned properly for the desired attachment configuration on the air/oxygen blender output. 5. Attach the flow meter to the air/oxygen blender output using the DISS connection. The flow meter must be mounted vertically for accurate measurements. 6. Restore pressure to the air/oxygen blender and verify that the float ball is at the very bottom of the flow tube. NOTE: If the float is not resting at the bottom of the flow tube, the product is leaking; consult the TROUBLESHOOTING Section 4.0. 7. Adjust flow: To increase- Turn knob counterclockwise To decrease- Turn knob clockwise 8. Set the flow by aligning the center of the float ball with the indicator lines on the flow tube. Adjusting flow beyond the last calibrated indicator line will result in an undetermined flow. 4 866.4.Maxtec www.maxtec.com

4.0 TROUBLESHOOTING 4.1 Troubleshooting Table PROBLEM CAUSE REMEDY Will not shut off Leak Sticking float ball or unable to set desired flow Defective valve Debris in flow tube Knob will not turn Valve seized Consult your provider or Maxtec 5.0 RECOMMENDED MAINTENANCE 5.1 Cleaning Instructions 1. Depressurize and disconnect all connections before cleaning. 2. Clean exterior surfaces of the flow meter with a cloth dampened with a mild detergent and water. 3. Wipe dry with a clean cloth. Caution: Do Not Autoclave 866.4.Maxtec www.maxtec.com 5

6.0 WARRANTY Under normal operating conditions, Maxtec warrants the Acrylic Flow Meters to be free from defects of workmanship or materials for the following period: a) Acrylic Housing... Lifetime of the product b) Needle Valve...Five (5) years from receipt c) All other parts not listed...two (2) years from receipt Warranty does not cover breakage/abuse. These warranties are from the date of receipt, provided that the product is properly operated and maintained in accordance with Maxtec's operating instructions. Based on Maxtec product evaluation, Maxtec's sole obligation under foregoing warranty is limited to making replacements, repairs, or issuing credit for equipment found to be defective. This warranty extends only to the buyer purchasing the equipment directly from Maxtec or through Maxtec's designated distributors and agents as new equipment. Routine maintenance items, such as o-rings, are excluded from warranty. Maxtec and any other subsidiaries shall not be liable to the purchaser or other persons for incidental or consequential damages or equipment that has been subject to abuse, misues, mis-application, alteration, negligence or accident. These warranties are exclusive and in lieu of all other warranties, expressed or implied, including warranty of merchantability and fitness for a particular purpose. For product warranty returns, please contact Maxtec Customer Service for a Returned Materials Authorization (RMA). 6 866.4.Maxtec www.maxtec.com

7.0 SYMBOL GUIDE Federal law (USA) restricts this device to sale on or by the order of a physician Not Manufactured with Natural Rubber Latex Warning! Storage Temperature -40 C (-40 F) 60 C (140 F) Consult instructions for use Non-sterile non sterile Manufacturer Authorized Representative Made in USA Contains no Polyvinyl Chloride PVC Do Not Designed for Blenders Maxtec 2305 South 1070 West Salt Lake City, Utah 84119 USA Toll-Free: 800.748.5355 International: 1.801.266.5300 Website: www.maxtec.com E-mail: sales@maxtec.com QNET BV Kantstraat 19 NL-5076 NP Haaren The Netherlands 866.4.Maxtec www.maxtec.com 7