Proof of concept of a Bio-Containment System for Mars Sample Return Mission

Similar documents
FlexAct BT (Bag Tester) Validation November, 2015

Development Report. Walker Barrier 10 Ergoclean Gloveport Interface. And. Single Piece Gauntlet Performance Testing

DeZURIK. KSV Knife Gate Valve. Safety Manual

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

User Manual November 2014

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

Paper Session II-C - Verification of International Space Station Component Leak Rates by Helium Accumulation Method

Installation, use and maintenance instructions. Gas burner (5)

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

Hermetic Compressor Manifold Analysis With the Use of the Finite Element Method

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Installation, operating and maintenance Instructions for Seemag bypass level indicator

First Experimental investigations on Wheel- Walking for improving Triple-Bogie rover locomotion performances

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Datasheet: K-30 ASCII Sensor

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

RESOLUTION MSC.94(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR NIGHT VISION EQUIPMENT FOR HIGH-SPEED CRAFT (HSC)

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

4400 TwinHybrid Gas Seal

Gas Network Craftsperson

Solenoid Valves used in Safety Instrumented Systems

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

Every things under control High-Integrity Pressure Protection System (HIPPS)

200 / 300 Upgrade Kits

H 2 O Bubble Chamber Superheated Active Target System. Safety and Systems Overview B. DiGiovine

Tightening Evaluation of New 400A Size Metal Gasket

Robotic On-Orbit Satellite Servicing: One Size Does Not Fit All

Discussion and guidance on the definition and qualification of porous loads

Integration of safety studies into a detailed design phase for a navy ship

Electro-Pneumatic Converter YT-940 SERIES

ST 18 Aluminium Gas Model

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

ST 18 Aluminium Gas Model

Standard Flexel 3D bioprocessing bags for Palletank

ME 8843-Advanced Mechatronics. Project Proposal-Automatic Bike Transmission

METNET Mission for Mars. MetNet. Atmospheric science network for Mars

SINEO Microwave Digestion Core Technology (2012)

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

User Manual MFCS TM -EZ

Pressure independent control valve (PICV) FLOWMATIC

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

PEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review

SIL explained. Understanding the use of valve actuators in SIL rated safety instrumented systems ACTUATION

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Application Note AN-107

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

SEMATECH Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems

Bio-sample testing on an adaptation to a tensile testing machine

valves and actuators SUBSEA ACTUATION

Anchor Load Cells. Among the different types that are used as anchor load cells

Code Basic module and level control complete with optionals code

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

ANL Bubble Chamber Superheated Active Target System

IMPROVED XENON LOADING EQUIPMENT WITH LOADING CAPACITY UP TO 1200 KG FOR ALPHABUS

XVII Congreso de Confiabilidad

Development of a High Pressure, Oil Free, Rolling Piston Compressor

Introduction to Pneumatics

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

CT433 - Machine Safety

6 th International Conference on Trends in Agricultural Engineering 7-9 September 2016, Prague, Czech Republic

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Specify the Right Remote Diaphragm Seal Solution for Vacuum Applications

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

e.do Gripper Safety requirements, technical features and assembly and integration instructions

WHITEPAPER. The flowplus 16 Pressure Sensor. Physical Principles and Function

NGN Series nitrogen generator

A NEW APPROACH TO BUCKLING DETECTION IN OFFSHORE PIPELINE LAYING

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

User Manual April 2015

rpbsafety.com Samoset Rd Royal Oak, MI USA OF THE NOVA 3 ABRASIVE BLASTING SUPPLIED AIR RESPIRATOR

Life Cycle Benefits: Maintenace (Control Valve Diagnostic and Field Device Diagnostic Management)

Design of an Automated Perfusion Pump James J Higham

Technical Specifications of Hydrogen Isotope Handling and Recovery System

Double Emulsion Droplet generation and collection protocol Version Author Date Reviewer Change 1 Introduction

LSG Single Point Failure Analysis

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B )

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

Upgrading Vestas V47-660kW

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

RocketSat V: AirCore. 4/18/09 Symposium Jessica (JB) Brown Mackenzie Miller Emily Logan Steven Ramm. Colorado Space Grant Consortium RocketSat V 1

2017 LOCKHEED MARTIN CORPORATION. ALL RIGHTS RESERVED

RD(H)20/25 Pressure-Reducing Regulator User Manual

The use of remote plasma emission spectroscopy as an alternative method of gas sensing for direct monitoring of vacuum processes

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Precision Liquid Settlement Array Manual

Electronic Automatic Transmission for Bicycle

Using STPA in the Design of a new Manned Spacecraft

High Pressure Heatable Liquid Cells GS05910, GS05915, GS05920, GS05925 Series User Manual

Relative Pressure Sensor for Automobile Fuel Tanks

Safety manual for Fisher GX Control Valve and Actuator

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

MIL-STD-883G METHOD

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

Agilent 1220 Infinity II LC Mobile Upgrade Kit

LNG TANDEM OFFLOADING A KEY ENABLING TECHNOLOGY TO MAKE LNG PRODUCTION OFFSHORE HAPPEN

E. MENDOZA, C. KEMPEN, Y. ESTERKIN, S. SUN, K. SUSKO and J. GOGLIA

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Transcription:

Proof of concept of a Bio-Containment System for Mars Sample Return Mission S. Senese (I), P. Magnani (I), A. Fumagalli (I), M. Colomba (I) A. Pedrini (II), D. Indrigo (II), A. Terribile (II), R. Ferrario (II) M. Guest (III) J. Romstedt (IV) (I) (II) (III) (IV) Selex Galileo, Viale Europa, 20014 Nerviano (Mi), Italy Tecnomare, Via Pacinotti 4, 30175 Venezia Marghera, Italy Systems Engineering & Assessment Ltd, SEA House, Bristol Business Park, Bristol, BS16 1EJ, UK ESA/ESTEC, Noordwijk, The Netherlands A Mars Sample Return (MSR) mission foreseen in the 2020s envisages the collection of some tens of samples of Martian soil for return to Earth. Once collected, each sample will be stored and capped into dedicated vessels and finally fixed into a dedicated container (Orbiting Sample - OS). After the storage of all samples, the OS will be launched into Mars orbit and transferred to the Earth Reentry Capsule (ERC) for the return trip to Earth. The transfer of the OS into the ERC, the return phase, Earth re-entry and samples curation are subject to stringent constraints with respect to Planetary Protection requirements in order to prevent any back contamination. As part of this transfer system, the main objective of the Bio-Containment project is the proof of concept of the sample container bio-barrier and the sealing monitoring system. In this paper, the basic design characteristics of the Biocontainment system will be given together with an overview of the main performed hardware activity. 1) INTRODUCTION As soon as the Orbiting Sample (OS) is captured around the Mars orbit, any contamination of the spacecraft and in particular of the ERC with Martian material must be avoided. In order to achieve this goal, a system capable to position the OS into the Bio-Container and break the chain with Mars has been put in place. It consists of sealing gaskets combined with a sterilization process. These operations are all actuated by dedicated mechanisms. Once the chain with Mars is broken, the Bio-container will be closed with two level of gasket based sealings. One of the two containment compartments is pressurized in order to enable a monitoring system the detection of possible major failures by pressure measurement. Dedicated mechanisms have been designed to execute all these operations. Once closed, the Bio-Container will be inserted into the ERC ready for the return flight to the Earth. During the whole return cruise the pressurized compartment of the Bio-container will be constantly monitored, so that in case the required sealing is not guaranteed, the ERC re-entry to Earth will be aborted. The performed breadboard test campaign had the objective to verify the functionality and performance of mechanisms and the overall system capability to fulfil the basic biocontainment requirement, which is expressed as follows: the probability that a single non sterilized particle larger than 10 nm in diameter is released into the terrestrial biosphere shall be below 10-6. 2) BIO-CONTAINER SYSTEM CONFIGURATION Characterizing features of the Bio-Containment system (see also Fig. 1) are: two containment vessels; chain Breaking Lid (to support Mars chain breaking); two lids (each equipped with gasketing system); monitoring system (pressurization, pressure and temperature sensors). Fig.1 Bio-container Overall Schematics

The outer vessel (D= 360 mm) is foreseen in titanium also to allow wireless power and data transfer. The Inner vessl (D= 260 mm) is foreseen in aluminium. The vessels are designed for re-entry loads and no feed throughs are utilized. Fig. 2 show the CAD drawing of the inner vessel. three clamps for final stroke and tightening; management of the lids (with different size); actuator based on Motor-Reduced; ball screw for output stage Fig.2 CAD drawing of the inner vessel and some stress analysis results Two lids are present (one for each vessel) and each is equipped with three gaskets sealing. Gaskets of different material and working principle are foreseen to limit common cause failures. A lid schematics is shown in Fig. 3. Each lid is equipped with a safe lock mechanism. Fig. 4 Schematics of lid closing mechanism (End Effector) Another important element of the Bio-Containment system is the Chain Breaking Lid (CBL) in charge to achieve the final bio-separation. The main features of the CBL (see also Fig. 5) are: made by two detachable halves; separation interface sterilized during integration; outer rims sterilized while in operation by thermal wave. Fig. 3 CAD drawing of one of the lid and a possible schematic for gasket placement A special mechanism (End Effector) has been developed to automatically close the lids. The mechanism is characterized by the following features/performances (see also Fig. 4): Fig. 5 Schematics of CBL Rim sterilised at start of operational phase (all around) Concerning the monitoring system (which internal location is shown in Fig. 6) is characterized by the following:

Power/Data transfer through a solid metallic wall; Transfer power from the external environment inside the metallic container sufficient to keep charged the internal energy storage system (some tens of milliwatts, minutes per day); Transfer data from the internal sensors and devices to the external environment (hundereds bit/s bandwidth); Manage the internal sensors and actuator and operate the correct operations sequence. The internal pressurization (in the range of 300-400 mbar) is achieved by perforating a small metallic reservoir containing Argon. The pressurization system (reservoir, puncher and actuator) are schematized in Fig. 8. Fig. 8 Schematics of pressurization system elements For safety and reliability aspects, the monitoring system is presently foreseen in triple redundancy and some implementation schematics is shown in Fig. 9. Fig. 6 Schematics of the Biocontainer and location of the monitoring system and coupling transformers The schematics of the internal electronics of the monitoring system is shown in Fig.7 and the functions performed are the following: Coupling transformers Rectifier Regulator Power Storage Data Tx (OOK logic) Smart Logic Controller Voltage regulator, Voltage monitor, Bus monitor Motor and Hall sensors P-T sensors Fig. 9 Some implementation schematics for triple redundancy 3) BREADBOARDS MODELS In the course of the activity several parts have been manufactured at Bread Board level and tested. The item manufactured have been relevant to both Bio-container parts (see schematics in Fig. 10) and Monitoring system parts (see table in Fig. 11). Fig. 7 Overall Scheme of internal electronics of Wireless System

Fig. 13 Simplified container and lids (with close mechanism) Fig. 10 Summary of bio-container Breadboard parts Pressurization device Wireless I/F Inner electronics Outer Electronic (for test purposes) Separatior Ti plate Fig. 11 Summary of monitoring system Breadboard parts Fig. 14 Closing mechanism (End Effector) From Fig. 12 to Fig. 15 are shown a selection of pictures of the manufactured/tested parts. Fig. 14 Monitoring System parts Fig. 12 Complete inner container

Fig. 17 shows the set-up utilized during the particle leak test (in support to the verification of the basic Planetary Protection requirement). Fig. 15 Basic pressure/temperature transducers (Off the shelf items) 4) TESTING ISSUES Several tests have been performed on the Bread Board parts throughout the activity and a qualitative summary is reported in Tab. 1 Fig. 17 Set-up utilized for the particle leak test 5) APPROACH FOR COMPLETE BIO-CONTAINMENT PERFORMANCE PROJECTION The approach utilized for the overall verification of the basic planetary protection requirement is based on the following steps: Tab. 1 Summary of performed tests In Fig. 16 are shown a selection of pictures of taken during lid closure and gas leak test testing. Starting point are the mathematical model developed (for gas and particles escape) and the specific leak tests for gas and particle Model verification Gas leak rate calibration (using 9 µm calibrated hole) Model/True gas leak comparison for validation Model calibration- Particle rate calibration through calibrated holes (9µ and 20µm) Model/True particles leak comparison for validation Gaskets characterization (using measured He data leak rate and measured particles leak) Viton gaskets Silicon gaskets Metal gaskets Complete BCS simulation with 10 nm particle size and argon gas in the intermediate container The Bio-containment system mathematical model schematics (for gas and particle escape estimation) is shown in Fig. 18. The application of the approach above described allows the determination of the pressure trend and particle escape trend in all simulated compartments (including the particles escaped outside the system). Fig. 16 Lid closure test (left), leak rate test (right)

Fig. 18 Overall Bio-container scheme used for the gas and particle escape Mathematical Model definition The modelling is based on seven chambers (the eight is the outside ) and seven gasketing system. For the gas, molecular plus viscous flow has been considered. For the particles (in Brownian motion) molecular flow has been utilized. 6) ORBITING SAMPLE HANDLING SYSTEM: A POSSIBLE CONFIGURATION A possible overall configuration for a complete Orbiting Sample Handling System (OSHS) is schematically shown in Fig. 19. Visible from the picture are the main elements in charge of the handling: the Capture Mechanism, the Bio- Containment related items (insertion mechanism into vessels, CBL, lids and related mechanisms) shown in the green background, ERC lid closure mechanism (in lower pink background), ERC. Fig. 20 Some steps of handling sequence (schematics) 7) CONCLUSIONS An important design and development activity is presently being concluded on the bio-containment system for the possible future Mars Sample Return Mission. Several parts have been detail designed, manufactured and tested and the results so far achieved seems compatible with the overall objectives. Some more development is being planned Fig. 19 A possible configuration for a complete Orbiting Sample Handling System The final key requirement related to very low particle escape probability is coped with by making use of the test results achieved in terms of leak rate and particle escape and propagating them via a mathematical model of the complete bio-container. In Fig. 20 is shown, schematically, an example of sequence; optimization of overall OSHS configuration can be done.