3M Littmann Classic II S.E. Stethoscope

Similar documents
Master Classic II Stethoscope

3M Littmann Master Cardiology Stethoscope

Lightweight II S.E. Improved Design & Acoustics. Stethoscope

the typical anatomy of the ear canal. The eartips should point in a forward direction as you insert them into your ear canals.

Classic II Pediatric Stethoscope Classic II Infant Stethoscope

STANDARD OPERATING PROCEDURE

3M TM Littmann Stethoscopes. A Trusted Leader in. Auscultation. Distributed by

600 / 600FC OWNER'S MANUAL

Mirage Vista Nasal Mask

Aneroid Sphygmomanometer. Use, Care, & Maintenance

602 STRINGING MACHINE OWNER'S MANUAL

RADAR. User Manual EASYCLIK MODEL Vascular. Compression. Device.

Item N o.: Item N am e:southern Star 40cm Girls Cherry Bike

WELLS JOHNSON HIGH VOLUME CANISTERS

Have questions? Chat with us live at raleighusa.com or call us at , 8am 5pm PST

OLYMPIC ARMS, INC. MPR SUPPLEMENTAL OWNER S MANUAL

CHAPTER 2 MAINTENANCE

200 STRINGING MACHINE

Hydraulic Punch Drivers

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

AR STYLE FIREARMS OWNER'S MANUAL: OPERATION, HANDLING, DISASSEMBLY / REASSEMBLY & SAFETY INSTRUCTIONS

RayPette Plus Autoclavable Pipette. User Manual

USER MANUAL Tisas Pistols

MECH-TECH SYSTEMS CCU MODEL FOR GLOCK PISTOLS

Safety Huber Needles

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Owner s Manual. Model H4685

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

The pipettes cover a volume range from 0.1µl to 10ml.

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

CARDINAL SPINNING REEL INSTRUCTION MANUAL

Have questions? Chat with us live at raleighusa.com or call us at , 8am 5pm PST

Hydraulic Punch Drivers

User Guide. Tripod. flowtech 75 / 100 Tripod. Part No. S S

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

Product Information News September 26, 2003

Have questions? Chat with us live at raleighusa.com or call us at , 8am 5pm PST

Item N o.: Item N am e:40cm GIRLS VIOLET BIKE

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

COUNTRYMAN E6 DIRECTIONAL EARSET MICROPHONE

Item Name: 30CM GIRLS STAR THE UNICORN BIKE

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

X-6 STRINGING MACHINE OWNER'S MANUAL. Issue 1 - May Copyright 2004 GAMMA Sports - All Rights Reserved

STRINGING MACHINE OWNER'S MANUAL. Issue 5 - November 2012

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

English. ivolve Full Face Mask. User Manual

ORRA SPINNING REEL INSTRUCTION MANUAL (DRAFT)

Manuale d istruzioni User s Guide Manuel d utilisation Manual de instrucciones Manual de instruções Οδηγίες χρήσης INSTINCT

Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper!

SUPER PRO TM SERIES DUMMY LAUNCHER

English USER GUIDE User guide

FAIR-COURT OFFICIAL BASKETBALL EQUIPMENT TESTING SYSTEM

SSS SWEEPERS MODELS MS-31 & MS-39

Sterile Visual Flow Indicator

Mini Mr.Bulletfeeder by Double-Alpha

Thanks for shopping with Improvements! 20 Reel Mower with Catcher Item #

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

Pipettor. User Manual

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

trigger magazine release

Linkam Scientific Instruments USER GUIDE DSC600. Temperature Controlled Stage

2 PRE USE FUNCTION CHECK 3 OPERATING PROCEDURE 4 SERVICING. 5 CAREvent ALS ACCESSORIES 11

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Rev. B. Operating Instructions

REVO LOW PROFILE INSTRUCTION MANUAL

G7S Hand Pump Owner s Manual

Air-Mate High Efficiency Powered Air Purifying Respirator (PAPR) Staff Training Module

TJF-Q180V Cleaning and Disinfection Checklist

DIRECT DRIVE DIXIE DOUBLE SEAMER Model 25D

FAIR-COURT OFFICIAL BASKETBALL EQUIPMENT TESTING SYSTEM

6 digital caliper with case

SAR-15 RIFLE OWNERS MANUAL

Pressure Injection Cell Operator s Manual

CONTENTS SAFE HANDLING OF GUNS

Helios Separable Tandem Manual

PHOENIX MMXI 7 FOOT 3 IN 1 BILLIARD TABLE

RG1200 Service and Repair Manual

Item N o.: Item N am e:40cm Boys Rival Bike

Stroller. Sprint S T R O L L E R S P R I N T

TJF-Q180V Cleaning and Disinfection Checklist


SASK-A-POLE OWNERS AND USERS MANUAL

14500 Coy Drive, Grass Lake, Michigan Isolation Glove Box Instruction Manual

Parts List. 7. Handlebars 8. Grips 9. Handlebar Stem 10. Front Brake 11. Front Wheel 12. Crank 13. Chain

VividTrac R. Video Intubation Device. INSTRUCTIONS FOR USE. English

LIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS

TIPPMANN 98 CUSTOM. Owner s Manual CO2 POWERED PAINTBALL GUN

OWNER S MANUAL ALWAYS WEAR A GOVERNMENT APPROVED FLOATATION DEVICE WHEN FISHING. Know the limits of your ability and the limits of your equipment.

IMPORTANT: RECEIVING INSTRUCTIONS:

General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead

Henry Pratt Diviner Position Indicator. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #:DIVPOSNOM Revision Date: 2/9/11

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Road Bike Maintenance Clinic

OWNER S MANUAL

Invacare Twilight II Nasal Mask

PISTOL CALIBER AR STYLE FIREARMS

GM-121: Container End Lock Anchor Wand Page 1 WINSAFE CORP. GM 121 CONTAINER END LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

Transcription:

English 3 ittmann Classic S.E. Stethoscope Congratulations on the purchase of your new ittmann Classic S.E. Stethoscope. his classic stethoscope with a two-sided chestpiece offers high acoustic sensitivity for superior performance. traditional bell is combined with a patented tunable diaphragm that conveniently alternates between low and high frequency sounds without the need to turn over the chestpiece. Other features include a patient-friendly nonchill rim and diaphragm, excellent acoustic seal and comfortable fit with patented 3 ittmann Snap ight softsealing eartips, and a comfortably angled, anatomically correct headset. dditionally, the single-lumen tubing is available in a variety of popular colors to meet individual preferences. ost of all, know that your ittmann Classic S.E. stethoscope carries the ittmann brand name, the name known worldwide for unsurpassed quality. s a trusted leader in auscultation technology, the ittmann brand of stethoscopes is your assurance of acoustical superiority, innovative design and exceptional performance. 1

nstructions for se Chestpiece On ittmann stethoscopes with traditional combination chestpieces, it is necessary to open the side of the chestpiece being used. his is accomplished by holding the chestpiece stem in one hand and rotating the chestpiece with the other hand until a click is felt. Changing Frequencies sing the unable Diaphragm our ittmann Classic S.E. Stethoscope is equipped with a patented tunable diaphragm that enables you to listen to both low and high frequency sounds without turning over the chestpiece. ow frequencies: o listen to low frequency sounds, (traditional bell mode) you can use either the open bell or tunable diaphragm using very light skin contact. High frequencies: o listen to higher frequency sounds, using the tunable diaphragm, press firmly on the chestpiece. o listen to low and high frequency sounds without removing and turning over the chestpiece, simply alternate between light and firm pressure on the tunable diaphragm. Headset djustment Correct ncorrect our ittmann stethoscope is designed to provide a comfortable, acoustically sealed ear fit. otice that the eartubes are set to accommodate the typical anatomy of the ear canal. he eartips should point in a forward direction as you insert them into your ear canals. o reduce spring tension in the headset, hold each eartube at the bend near the eartip and gradually pull apart until fully extended. o increase spring tension, grasp the headset with one hand where the eartubes enter the tubing and squeeze until the tubing on one eartube touches the other. Repeat as necessary. For maximum acoustic performance, comfortable patented 3 ittmann Soft-sealing Eartips are provided with your stethoscope. his stethoscope utilizes a unique design for attaching the eartip to the eartube. he eartips are 2

pushed on to the end of the eartube and snapped firmly into place. o remove, pull firmly on the eartip. Removing the Diaphragm and Cleaning the Chestpiece With the diaphragm side up, grasp the rim with the thumbs and index fingers of both hands and roll the rim off the edge of the chestpiece. Remove the diaphragm from the rim and clean the parts in soapy water or wipe with alcohol. Chestpiece surfaces can be wiped with alcohol or soapy water. Dry all parts and surfaces thoroughly before reassembly. ssembly and Replacement of the unable Diaphragm sing your fingertip, apply a small amount of talcum powder to the inside surface of the flexible edge of the diaphragm. his will facilitate assembly and maintain smooth and quiet low/high frequency alternation. Snap the diaphragm with your fingers to remove excess talc. nsert the flexible edge of the diaphragm into the groove of the rim. his is best accomplished by starting with the rim positioned above the legible side of the diaphragm. Visually examine the ring to ensure that the flexible edge is smoothly engaged inside the rim. f necessary, flex the assembly by pinching the outer rim edge between the thumb and fingers. Repeat this flexing procedure after rotating the assembly one quarter. o attach the rim/diaphragm assembly to the chestpiece, engage the groove of the rim (with the diaphragm attached) around the chestpiece at one point and hold it in place with your thumbs. Slowly roll the rim around and over the chestpiece edge using both thumbs, moving in opposite directions around the chestpiece. Visually inspect the edge where the diaphragm engages the rim for uniform containment. inor adjustments may be made by slightly pulling and rolling the rim away from the diaphragm, allowing the diaphragm to slip into position. 3

General se and aintenance void extreme heat, cold, solvents, and oils. he entire stethoscope can be wiped clean with alcohol or soapy water. Eartips can be removed from the eartubes for thorough cleaning. OE: Do not immerse your stethoscope in any liquid or subject it to steam sterilization. f disinfection is required, the stethoscope may be wiped with a 70% isopropyl alcohol solution. ittmann Stethoscope Service and Warranty Program our ittmann stethoscope comes with the finest service and warranty policy in the industry. he ittmann Classic S.E. Stethoscope is warranted against any defects in material and workmanship for a period of three (3) years. f a material or manufacturing defect is discovered during the warranty period, repairs will be made without charge upon the return of the instrument to 3, except in cases of obvious abuse or accidental damage. 3 Health Care Service Center Bldg. 502, Suite 200 3350 Granada ve. orth Oakdale, 55128 CD: 3 Health Care Service Centre 3 Canada nc. 80 Enterprise Drive South ondon, Ontario Canada 61C2 1-800-563-2921 Outside of the.s. and Canada please contact your local 3 subsidiary for maintenance and repair information. Explanation of Symbols:! ttention, see instructions for use. his product and package do not contain natural rubber latex. For maintenance or repair services, write a short note explaining the repair or service you require, include your name, address and phone number and send your stethoscope directly to: 4