better measurement Simply a question of

Similar documents
better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

SCHMIDT Flow Sensor SS Instructions for Use

C-Flow Coriolis Mass Flow Meters

Mass Flow Controller (MFC) for Gases

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Thermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption

Mass Flow Meter (MFM) for gases

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

[Instruments for vacuum measurement, checking and adjustment] 3

SITRANS P measuring instruments for pressure

Mass Flow Meter (MFM) for Gases

Flow metering in gases Introduction to COMBIMASS family

deltaflowc deltaflowc Venturi or Probe

2/2-Way Solenoid Control Valve

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Mass Flow Controller (MFC) for Gases

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

MANUAL KPS Pressure Control Valve

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

Pressure Measurement Single-range transmitters for general applications

Mass Flow Controller (MFC) for Gases

Technical Data Sheet MF010-O-LC

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Proportional pressure regulators VPPE

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Electronic Turbine Meter TERZ 94

How to specify a product. Process Sensors and Mechanical Instruments

4/2 way Pneumatic Solenoid Valve

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Pressure Switches Application Guideline

Pneumatic spool valve islands

TF- & DM-Series. Turbineflowmeter

Mass Flow Controller (MFC) for Gases

RMG Meßtechnik GmbH. Publication No E

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

FLAMMABLE GAS SENSOR/TRANSMITTER

Tightness controls TC 1 3 and TC 4

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Expert Hydrostatic Level Transmitters

High-performance submersible pressure transmitter For level measurement Model LH-20

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Technical Data. Dimensions

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

JUMO dtrans p30 Pressure Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-20

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Gas density monitor With integrated transmitter Model GDM-100-TI

Level switches Series LD Vibrating fork level switch for liquids and solids

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Supplementary Operator s Manual 42/24-14 EN Rev. 3

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Mass Flow Controller (MFC) for Gases

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

GasSense NDIR User Manual

780S Ultra High Purity Series

Pressure Transmitters 36 F-27839

Gas Pressure Regulator HON 200

OPTIBAR P 1010 C Technical Datasheet

Tightness control TC. Product brochure GB 3 Edition AGA

Variable Area Flow Meters

Bypass Mass Flow Controller (MFC) for gases

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Visualize Nitrogen Gas Consumption

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.

Level switches Series LD Vibrating fork level switch for liquids and solids

Climatic Independent Level Sensor LAR

Differential pressure

High-performance submersible pressure transmitter For level measurement Model LH-10

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Digital Mass Flow Meters and Controllers for Gases

Technical Data. Dimensions

Polymer Electric. Product information. Normally Closed Safety Edges SL/NC II. GmbH & Co. KG. Polymer Electric

Technical Data. General specifications. Rated operating distance s n 5 mm

ATM.1ST/Ex - High Precision Transmitter

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

Technical Data. General specifications. Rated operating distance s n 2 mm

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

ATM.ECO - Analog Pressure Transmitter

Instruction Manual Differential Pressure Transmitter

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Transcription:

Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology

Flow rate volumes of gases an important parameter in industrial processes Evaluation electronics Measures to save energy and to assure quality in the production process are of particular importance in industrial processes. The ability to measure volumetric flow rates and volumetric flow of gases precisely has an important role to play in this. The requirements imposed on the flow rate sensor used for this are demanding: the sensor has to be capable of delivering precise measuring results for different gases, at high overpressures and across wide ranges of temperature. It also has to be able to do so under the most difficult environmental conditions such as explosive areas and in the open air. A further criterion involved in the selection of a suitable sensor is the prevention of maintenance and its attendant high secondary costs. Ease of assembly and reliable measuring values for many years: that is the objective. The true professional for industrial processes and pneumatic technology The thermal SCHMIDT Flow Sensor SS 20.600 is the perfect solution for demanding industrial applications. It can be used for a diverse range of applications, such as compressed air monitoring, gas monitoring on process burners, consumption recording of gases and a great deal more. The sensor records flow speed as well as media temperatures of up to 120 C. It can be used in small tubes from DN 25 upwards and can involve a sensor length of up to 1 metre to measure the volumetric flow rate in large channels and ducts. If the standard version is not sufficient for overpressure of up to 16 bar, a version rated for up to 40 bar can be selected. This sensor is very easy to install: screw down the sensor using the compression fitting included, align the sensor in the gas flow and centrally in the pipe, connect up its electrical wiring and job done! This sensor operates without any moving parts and employs a measuring principle that eliminates any drift or signs of ageing. This reduces the maintenance required for the sensor depending on how contaminated the medium becomes to the occasional need for the sensor head to be blown through (air blast) or rinsed in water. High gas speeds, special gases or explosion protection? The SS 20.600 can do (almost) everything! The special chamber head sensor records flow speeds of 0.2 m / s up to 220 m / s. In order to obtain precise measuring results across this very broad speed range, every sensor is individually checked and compared in an elaborate pressurised wind tunnel. To enable this sensor to be used in different gases, a range of individual versions is available, e. g. for pure oxygen, CO2, methane. Of particular interest: Hydrogen will become an important parameter in future, and it can also be measured using the SS 20.600 (option). For use in other media in potentially explosive atmospheres and environments, the sensor is optionally available in an explosionprotected version (ATEX). Output signals: - 4... 20 ma / 0... 10 V - Impulses (0... 100 Hz or impulse / m3) Protective chain

Practical examples Branch Application The solution with SS 20.600 Industrial processes Measurement of incoming air to control industrial burners / incinerators - High flow rate speeds of up to 220 m / s - Measurement of standard volumetric flow rate independent of pressure and temperature - O2 version for pure oxygen Recording of inert gas volumes (nitrogen) - Specific versions for gas and gas mixtures - Resistant to overpressure up to 40 bar Control of combustion gas volume (natural gas, methane,...) - ATEX version - For pipe diameters from DN 25 Detection of gas consumption - Acquisition of the flow rates of almost zero to the maximum value (detection gas slippage) - From - 40 C temperature of medium usable (ATEX version) Compressed air consumption, compressor control - Extremely wide measuring ranges for flow rate - Simple signal processing: impulse per m3 Leakage measurement - Measurement from 0.2 m / s - Design principle eliminates age-dependent drift Monitoring of minimum flow rate - High-precision adjustment (1 % precision) - Very fast response speed Pneumatic technology Flow sensor (incl. temperature measurement) 22 How does it work? The flow sensor element is protected, and is positioned in the chamber head in a way that favours unimpeded flow. Sensors for flow rate as well as temperature are arranged on the ceramic sensor element. For protection purposes, sensors are coated with a thin layer of glass. The flow sensor is heated to 40 K above the temperature of the medium. The power required to maintain this positive temperature differential ( overtemperature ) is an indicator for the flow rate speed that the sensor issues as normal speed (linear current / voltage / impulse signal). This is a great advantage of the measuring principle: No additional measurement of the pressure or temperature of the medium is required. flow flow 0 m /s

Individually adapted to suit every application you have the choice! For optimum installation in the various different pipe diameters, 4 standard sensor lengths as well as special lengths of 120 to 1,000 mm can be selected. A remote version is available for difficult installation conditions. The probe length itself and the cable length between sensor and housing can be selected. To enable the sensor to be adapted to flow rate conditions, 6 standard measuring ranges are available, extending up to 220 m / s. The volumetric flow rate is the result of the flow rate speed, multiplied by the pipe cross-sectional surface area and a profile factor. However, customer-specific measuring ranges can also be supplied in increments of 0.1 m / s. The advantage of this is that a desired maximum volumetric flow rate determines the measuring range of the sensor depending on pipe diameter. Example: Maximum volumetric flow rate of 450 m³ / hr with a pipe diameter of DN 65 yields a maximum flow rate measuring range for the sensor of 48.1 m / s (= 20 ma or 10 V). For the purposes of simple conversion, the homepage features a flow rate calculator that also determines the profile factor, which is dependent on the pipe cross section. For evaluation systems with impulse inputs, the SS 20.600 offers an additional impulse output for the flow rate signal. There is a standard measuring range of 0 100 Hz available or, if the pipe diameter is indicated, impulses per m³ as a customer-specific output as an option. Measure other gas media too? Absolutely! More often than not, the medium being measured is not air, but instead comprises other gases or gas mixtures. For these special applications, gas-specific versions of the SS 20.600 can be supplied. With these versions, the sensor has a specific correction based on adjustment in air programmed in. These correction factors were established individually for each gas on real gas channels. For gas mixtures, each correction is calculated on the basis of an individual customer specification. For media with an oxygen content of > 21 % of volume all components in contact with the media must be cleaned to remove greases, oils and / or other combustible elements. A specific grease-free and O2 > 21 % variant provides the required safety for this application. Accuracy in black & white As an option, the SS 20.600 can be supplied with a high precision adjustment for air that can also be used for pure oxygen and nitrogen. This measurement is carried out at SCHMIDT Technology. The high levels of precision and reproducibility are documented in an ISO calibrationcertificate (attached). This calibration can be renewed to suit user definitions. Everything in view The LED display is dual function. In normal operation the 4 x LED s illuminate steady green in sequence. In fault condition reportable faults are indicated by red flashing LED s. The instrument will output V and ma and change-over is automatic.

Use in combustible or explosive media The optional ATEX version SS 20.600 Ex is designed for use in the Zone 2 category of explosive gas atmospheres. For this, specific protection functions are incorporated, among other things, one example being a protective sleeve for the plug connector and the ground / earth terminal on the housing or, on the remote version, with an additional one on the sensor tube. This version enables a minimum medium temperature of - 40 C to be reached.

6 Dimensions of the basic sensor ATEX version SS 20.600 Ex (optional) 29 L 49 17 39 7,2 29 L 49 17 39 Ø 15 G½ 12 Ø 15 G1/2 12 8 25 SW 27 SW 24 8 12.5 25 SW 27 SW 24 Erdungsklemme Ø 67,3 Flow Flow Ø 24 130 Remote sensor including wall mounting bracket L 47 42 Remote sensor, ATEX version (optional) including wall mounting bracket L 47 42 Ø Ø 88 130 67,3 Ø 88 58 59 58 59 16,5 50 16,5 50 44 21 60 80 44 21 60 80 Ø 4,5 4 x Ø 4,5 4 x 4 8,5 4 8,5 36 36 Mounting instructions Mounting parameters infeed line 10 x ID min. outfeed line 5 x ID min. AL Ø ID DA DA / 2 SL 36 E R L D A = Outer diameter of tube SL = Length of welding sleeve E = Adjustable length of sensor tube AL = Extended length of compact sensor R = Reference length L = Length of sensor All dimensions in mm

7 Technical Data Measuring data Measuring values Standard flow velocity w N normalized to 20 C and 1,013.25 hpa; temperature of the medium T M Air or nitrogen; optional: Methan, natural gas, biogas, CO2, oxygen and specialty gases and gas mixtures 0... 10 / 20 / 60 / 90 / 140 / 220 m / s; optional: customised measuring ranges in 0.1 m / s-steps 0.2 m / s Measuring fluid Measuring range w N Lower detection limit w N Measuring range T M - 20... +120 C; SS 20.600 EX: - 40... +120 C Accuracy 1) Standard w N ± 3 % of measured value + (0.4 % fmr; min. 0.08 m / s) High precision w N (optional, for air, ± 1 % of measured value + (0.4 % fmr; min. 0.08 m / s) nitrogen, oxygen only) 1) Repeatability w N ± 1 % of measured value Response time t 90 w N 1 s (jump from 0 to 5 m / s air) Temperature gradient w N < 8 K / min at w N = 5 m / s Measurement accuracy T M ± 1 K (10... 30 C); ± 2 K remaining measuring range (@ w N > 5 m / s) Operating temperature Sensor - 20 + 120 C ; SS 20.600 EX: - 40... +120 C Electronics - 20 + 70 C Storage temperature - 20 + 85 C Material Housing Aluminium, anodized Sensor tube, screw connection Stainless steel 1.4571 Sensor head Platinum resistor element (glass-passivated), PPO / PA Protective sleeve Aluminium, anodized Sensor cable (on remote sensor) Jacket PUR, halogen-free, UL General Data Medium, environment Non-condensing (up to 95 % RH) Maximum pressure 16 / 40 bar; oxygen (O2 > 21 %: 20 bar Display 4 x Duo LEDs green / red / orange Supply voltage 24 V DC ± 20 % Current intake Approx. 50 ma (without impulse outputs); max. 250 ma Analogue outputs for temperature and flow rate Auto U / I Impulse outputs Electrical connection Maximum line length Mounting position Installation tolerance Minimum tube diameter DN 25 Type / class of protection ATEX category Sensor length Weight 0 10 V / 4 20 ma (protected against short circuits) Voltage output: > 550 Ω Current output: < 500 Ω Hysteresis: 50 Ω Frequency 0 100 Hz, optional: 1 impulse / 1 m 3 ; 1 impuls e/ 0.1 m 3 / h; 1 impulse / 0.01 m 3 / hr (max. 100 Hz) 1. Highside driver to supply voltage (not galvanically isolated) High level: > supply voltage - 3 V Short circuit current limitation: 100 ma 2. Semiconductor relay (galvanically isolated); max. 30 V / 50 ma Plug-in connector M 12, screwed, 8-pin, male Voltage signal: 15 m, current signal / impulse: 100 m Any (with vertical downdraft: lower limit of measuring range 2 m / s @ 16 bar) ± 3 to flow direction IP 65 (housing), IP 67 (sensor) / III (SELV) or PELV II 3G Ex na ic IIC T4 Gc 1) under reference conditions, related to adjustment reference Compact sensor: 120 / 250 / 400 / 600 mm; special lengths from 120 to 1,000 mm Approx. 500 g max. (without connection cable)

8 Accessories SCHMIDT Probe ball valve (see seperate brochure) A choice of probe ball valves are available to facilitate fast removal and installation in 1 to 2 pipework. Advantage: even while the system is under pressure, it is no problem to install or remove the sensor. A straight-run ball valve is available for larger pipework diameters. Extended connection options with field bus modules LED measured value display (see seperate brochure) For visualization purposes directly on location, an LED unit is available to display measuring values. The advantages: Display in m / s or m3 / h Programmable output signal Two programmable relay outputs Power supply: 85 250 V AC or 24 V DC Power supply to the connected sensor Separate version with sum function Detection of flow direction by the use of two SS 20.600 units arranged at 180 to one another As an option, the following variants are available for integrating the SS 20.600 into existing BUS systems: DeviceNet ProfiBUS DP Others on request The BUS modules are housed in a rugged auxiliary housing. The standard outputs are available in addition to the BUS signal. Shielded connection cable available in various lengths Sensor 1 FLOW Coupler socket with screw type terminals Type no. 524 929 Sensor 2 FLOW Welding steel sleeves Type no. 524 916 or stainless steel Type no. 524 882

Order information for the SCHMIDT Flow Sensor SS 20.600 Basic sensor Description Schmidt Flow Sensor SS 20.600; output signal 4... 20 ma and 0... 10 V; impulse output, incl. pressure-tight stainless steel compression fitting Optionen Article number 524 600 A B C D E F G H PP Mechanical type Sensor length 120 mm 1 Sensor length 250 mm 2 Sensor length 400 mm 3 Sensor length 600 mm 4 Special lengths (> 120 mm to 1,000 mm): Length: mm 8 Remote sensor incl. wall mounting bracket - sensor length (selectable lengths: 120 / 250 / 400 / 600 mm): mm - cable length (1... 10 m): m 9 Pressure-tight compression fitting, stainless steel G ½ 1 Pressure-tight compression fitting, stainless steel R ½ (P T) 2 Measuring ranges 1 and calibration Measuring range 0... 10 m / s 1 Measuring range 0... 20 m / s 2 Measuring range 0... 60 m / s 3 Measuring range 0... 90 m / s 4 Measuring range 0... 140 m / s 5 Measuring range 0... 220 m / s 6 Special measuring range (10... 220 m / s) in 0.1 m / s-steps:, m / s 9 Standard adjustment 1 High-precision adjustment check incl. ISO calibration certificate 2 Standard adjustment check with conversion factor for methane 2) w N max: 90 m/s Standard adjustment check with conversion factor for biogas (60 % methane, 40 % CO 2) 2) w N max: 35 m/s Standard adjustment check with conversion factor for CO 2 2) w N max: 60 m/s 3 4 5 Standard adjustment with correction of natural gas with 88 % CH4 7 Standard adjustment check with conversion factor for special gases and mixtures 2) 9 Impulse output Standard 100 Hz (= final value of measuring range w N) 1 1 impulse / 1 m 3 for pipe diameter (round) mm 2 1 impulse / 0.1 m 3 for pipe diameter (round) mm 3 1 impulse/ 0.01 m 3 for pipe diameter (round) mm 4 Additional outputs Protection type ATEX Without communications module 1 Communications modules for Profibus, others on request 3) * Without ATEX design (SS 20.600) 1 ATEX design (SS 20.600 EX) 2) 2 Protection type, Standard application 1 grease-free; O 2 Grease-free and for O 2 > 21 % 2) 3) (pmax = 20 bar) 2 Overpressure Operating pressure DD: 00 (atmospheric)... 16 bar 00... 16 Operating pressure DD: 17... 40 2) 17... 40 * On request 1) To select the appropriate measurement range please use our flow calculator tool on www.schmidttechnology.de 2) Not available in combination with the option special lengths 3) Not available in combination with ATEX

Order information SCHMIDT Flow Sensor SS 20.600 Describtion Article number Accessories Connecting cable, 8 pole, length 5 m, with coupler socket and open cable end 524 921 Connecting cable, 8 pole, length selectable, with cable end sleeves, free of halogen 524 942 Coupler socket, 8 pole, with screw terminals, for cable ø 6... 8 mm 524 929 Welding sleeve steel G ½ acc. to EN 10241, 5 pieces 524 916 Welding sleeve stainless steel 1.4571 G ½ acc. to EN 10241, 2 pieces 524 882 Power supply: output 24 V DC / 1A; input 115 / 230 V AC 535 282 SCHMIDT LED display MD 10.010; in wall housing to to show the volume flow and flow velocity, 85 250 V AC and sensor supply 527 320 SCHMIDT LED display MD 10.010; similar to 527 320, but with 24 V DC voltage supply 528 240 SCHMIDT LED display MD 10.015; in wall-mounted housing, similar to 527 320 but with additional sum function and second measuring input 527 330 SCHMIDT LED display MD 10.015; similar to 527 330, but with 24 V DC voltage supply 528 250 Assembly kit for pipe assembly, suitable for MD 10.010 / 10.015, including pipe clamps and collar for adjustment to the pipe diameter Probe ball valve 1 inside thread, connection to flow sensor: ½ inside thread incl. plug and chain Probe ball valve 1¼ inside thread, connection to flow sensor: ½ inside thread incl. plug and chain Probe ball valve 1½ inside thread, connection to flow sensor: ½ inside thread incl. plug and chain Probe ball valve 2 inside thread, connection to flow sensor: ½ inside thread incl. plug and chain 531 394 530 940 530 941 530 942 530 943 Form 1100/08/12/3000/2 Art. No. 536001.02B Data subject to change Straight-run probe ball valve ¾ inside thread, with threaded adapter for ½ full-length screw connection ¾ 532 355 Welded socket, steel, outside thread ¾, 5 pieces 531 200 Welded socket, stainless steel, outside thread ¾, 2 pieces 531 201 SCHMIDT Technology GmbH Feldbergstraße 1 78112 St. Georgen / Germany Phone +49 7724 / 8990 Fax +49 24 / 899101 sensors@schmidttechnology.de www.schmidttechnology.de www.schmidt-sensors.com