SUMMARY PROBLEMS CAUSED BY BACKFLOW IN PIPE SYSTEMS.

Similar documents
Experiment 8: Minor Losses

UNIT 15 WATER HAMMER AND SURGE TANKS

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

The Discussion of this exercise covers the following points:

CVEN 311 Fluid Dynamics Fall Semester 2011 Dr. Kelly Brumbelow, Texas A&M University. Final Exam

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Modelling of Pressurised Pipes within InfoWorks ICM and CS

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

776 Cryogenic Safety Valve

EDUCTOR. principle of operation

Instruction Manual. Pipe Friction Training Panel

MATH AND MAINTENANCE FOR PUMPS AND BLOWERS TRAINING SEMINAR

BY THOMAS M. WALSKI, BRIAN LUBENOW, AND JEFFREY SPAIDE. When they install a branch from a water distribution main,

Application Worksheet

Water Hammer In Irrigation Systems 1

RESIDENTIAL WATER DISTRIBUTION

Barcol-Air BRM Radiant Module

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Regulating valves REG-SA and REG-SB

Tutorial. BOSfluids. Relief valve

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gerald D. Anderson. Education Technical Specialist

BACK PRESSURE / SUSTAINING

SIZING OF WATER PIPING SYSTEM

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

Integral type Differential pressure flowmeter VNT Series

BACK PRESSURE / SUSTAINING

ANSWERS TO QUESTIONS IN THE NOTES AUTUMN 2018

Homework of Chapter (4.2,4.3)

THE INNER WORKINGS OF A SIPHON Jacques Chaurette p. eng. January 2003

Free Surface Flow Simulation with ACUSIM in the Water Industry

(Refer Slide Time: 2:16)

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

756 Safety Relief Valves

FILTER BYPASS CONTROL

HIGH FLOW PROTECTION FOR VARIABLE SPEED PUMPS

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

Hand operated regulating valves Types REG-SA and REG-SB

Evaluating Surge Potential in CSO Tunnels

STAP. Differential pressure controllers DN , ANSI flanges

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

22. Specialty Valves.

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

VACUVENT VE SERIES CATALOGUE

DIMENSIONING WATER SUPPLY SYSTEM IN BUILDING

Joint Expo 2012 February 7-8, 2012 BASIC HYDRAULICS

SIZING THE WELL-X-TROL

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

STA-F Description. STA-F Prefab insulation Measuring nipples

Applied Fluid Mechanics

Operational Behaviour of Safety Valves with Constant Superimposed Backpressure

for Stainless Steel Lines of Pressure Vessels, Hot Water Boilers, Heat Exchangers, Secondary Side of Pressure Reducing Valves etc.

Theory, Application, and Sizing of Air Valves

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Energy balance of the model as described in Theory and Model

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

Greenup Lock Filling and Emptying System Study

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Differential Pressure Control Valve (DPCV)

Analysis of pressure losses in the diffuser of a control valve

Transient Analysis and Design Considerations for Hydraulic Pipelines. Jonathan Funk, EIT

Technical Bulletin 160. Maximum Air Pressure for Diffusers. by:

Irrigation &Hydraulics Department lb / ft to kg/lit.

STAINLESS STEEL OVERFLOW VALVE TYPE 417

OIL AND GAS INDUSTRY

Theory, Applications and Sizing of Air Valves

I.CHEM.E. SYMPOSIUM SERIES NO. 97 BUOYANCY-DRIVEN NATURAL VENTILATION OP ENCLOSED SPACES

differential pressure regulating valve - threaded

Transient Analyses In Relief Systems

Hours / 100 Marks Seat No.

SIZING OF WATER PIPING SYSTEM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Pressure and Flow Control Valves DBGM, German and European Patents

Permeability. Darcy's Law

PRESSURE SURGES IN PIPELINES

Modeling a Pressure Safety Valve

Pressure Regulators. Aperflux 101

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

STRUCTURE S-65 PURPOSE SPILLWAY OPERATION

Safety devices for overpressure protection. Rupture discs: applications, sizing, and types

STAP. Differential pressure controllers DN , ANSI fl anges

Hours / 100 Marks Seat No.

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

AUTOMATIC FLOW CARTRIDGES. Competition Analysis Not All Automatics Are Created Equal

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Pressure regulating valves Types OFV, OFV-SS

Air Operated Hydraulic Pumping Systems to 50,000 psi

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

APPENDIX B HYDRAULIC DESIGN DATA FOR CULVERTS

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

NOTES ON WATER HAMMER. 55

Transcription:

Page 1 of 11 SUMMARY There are many problems derived from a reverse flow in a piping system. A solution presented in this paper is the WaStop inline check valve. The paper aims to explain some of the important technical aspects when choosing a check valve, such as choice of materials used to manufacture the valve and pressure losses when in operation. PROBLEMS CAUSED BY BACKFLOW IN PIPE SYSTEMS. A pipe system operates on a pressure differential. There has to be a higher pressure upstream relative to downstream, to enable flow in the wanted direction. The differential is created by either a pump or an elevation change or a combination of the two. If the pressure differential becomes negative there will be a flow in the opposite direction. CAUSES: Heavy rain/snowfall, Storm water systems are dimensioned for normal rain. To dimension a system to handle exceptional rain is in practicality impossible, hence in case of heavy rain or snow the system becomes overloaded. High tide in combination with low elevation. Pump failure. PROBLEMS: Overflow of basements or even whole areas. Storm water overflows into sewage systems and overloads treatment plants. Contamination of reservoirs etc.

Page of 11 SOLUTION To prevent problems caused by backflow in a system, backflow prevention in form of a check valve or a flap gate is installed. The WaStop is an inline check valve which is closed by default. Wastop consist of two main components a valve body and a membrane. The valve body ensures that membrane has a perfectly matched surface enabling an airtight seal between the membrane and the valve body. The valve body seals against the pipe with a conical rubber seal allowing a good fit in a range of different diameter pipes. The valve body is manufactured in stainless steel; AISI 304 or 316 the difference between the materials being -3% molybdenum improving 316s resistance to chlorides such as seawater, hence the popular name marine grade. The material of the membrane is either a special blend Silicone MVQ or a polyether based Polyurethane, smaller dimension WaStops are made in Silicone which has a high resistance to various chemicals and temperature variations. The larger dimension WaStops are made in polyurethane with high mechanical properties, giving the membrane high resistance to wear and tear. Both membrane materials having high elasticity, meaning they will return to its initial shape and size when the forces deforming the membrane are removed. Hence the membrane is referred to as the memory membrane. The membranes have been tested and showed no change in properties after 150 000 cycles (opening/closing). The membrane is delivered as standard in three different shore hardness ranging from 35-80 SH. The softer membrane has a lower opening pressure but can t withstand as high backpressure, while the harder membrane has a higher opening pressure and is able to handle more backpressure. The application dictates which hardness to choose.

Page 3 of 11 TECHNICAL ASPECTS Important technical aspects deciding on which backflow prevention to use includes opening pressure and head loss. OPENING PRESSURE Since the WaStop is closed by default it operates with certain opening- and closing pressures. The difference between opening and closing pressure creates a pulsating effect, by rapidly changing the fluid velocity in the pipe it self-cleanses both the valve itself and the system. Both opening pressure and head loss is both defined as Δh in fig.1. The difference being that the opening pressure refers to when there is no flow through the valve, and head loss is the pressure loss when there is a flow through the valve. FIG. 1 OPENING PRESSURE AND HEAD LOSS DEFINITION.

Page 4 of 11 PRESSURE LOSS Pressure loss in a pipe system is calculated as the sum of major losses associated with energy loss per length of pipe and minor loss associated with bends, fittings, valves etc. Minor losses are estimated as:, = = h, h, =, : [ ] h, : ( ) : [ ] : :9.81 The total head loss of a system being: [ ] : h [ ] : [ ] h = + Since the hydraulic area of the WaStop depends on the flow through the valve, depends on the fluid velocity in the pipe. The amount of throttling introduced by a check valve in the system determines the hydraulic efficiency of the valve. From fig.6-11 (Appendix A). It is apparent that the loss coefficients are lower when the outlet is submerged compared to the open air discharge. An explanation is that the density of the membrane is only slightly higher than the density of water. Hence the apparent immersed weight of a membrane with the volume 0.1 m³ and mass 130kg is only 30 kg submerged in water. Therefore the membrane opens more when submerged, i.e., larger hydraulic area meaning a lower head loss. Δh < Δh [ ]

Page 5 of 11 METHODS OF ESTIMATING HEAD LOSS There are several methods of estimating head loss. The method in this paper uses the resistance coefficient. For all pipe fittings head loss are close to being proportional to the velocity head. As a result there are a few methods aimed at finding the correct multiplier for the velocity head term, such as the and the equivalent length method. As the name suggests when using the equivalent length method one tries to convert the minor losses to an equivalent length of pipe which would give the same head loss as the fitting. : h [ ] h = + A method not based on finding a multiplier for the velocity head and mainly used for valves is the method. By definition the valve flow coefficient = 1 when a pressure of 1 psi causes flow of 1 US gallon per minute of water a 60 through the valve. = This is a dimensional formula and the dimension must be in the following units : [ ] : [ ] : 60 The European equivalent being of a different magnitude with parameters in SI units. In order to convert between and values we need to re-arrange equations and with the relation = h bring them to similar form, an exercise yielding the result: : [ h ] = 9.9

Page 6 of 11 CASE STUDY OF PIPE SYSTEM WITH AND WITHOUT A WASTOP DN600 (4 ), A comparison of the total head loss (major + minor) of a system with 0 m (330 ) concrete pipe discharging into a slow moving lake, with and without a WaStop. h = 0.5 4 h h = 1 FIG. PIPE SYSTEM DN600 0m (330 feet) ASSUMPTIONS: Pipe roughness = ( = ), pipe diameter 600mm (4 ) Discharge submerged, all the velocity potential is lost; = 1 (without a Wastop) Inlet to the piping system = 0.5 values for the given flow rates for the outlet with a WaStop from a test done at the Utah State University Water Researched Laboratory. Incline 4 (=0.4%) [mmh0] 5 000 4 500 4 000 3 500 3 000 500 000 Total Head loss DN600 with and without WS590 Pipe + WS590 Pipe 1 500 1 000 4 500 0 0 Vel. [m/s] 0.0 0.5 1.0 1.5.0.5 3.0 3.5 16 14 1 8 6 [feeth0] Vel. [fps] 0 4 6 8 1 FIG. 3 TOTAL HEAD LOSS PIPE SYSTEM (FIG. 4) WITH AND WITHOUT WASTOP 590

Page 7 of 11 INTERPRETING HEAD LOSS DATA Comparing head loss data is difficult since the test procedure is rarely presented and there are multiple ways of altering data. However, the test results shown below were conducted in the same facility with the same reference points etc. are comparable. The test result shows that the WaStop has 65% lower head loss than a competing inline check valve at flow (m/s). Both valves were tested in the same open air scenario. [mm H0] 4 500 4 000 3 500 3 000 500 000 1 500 1 000 500 0 Flow [l/s] Pipe Velocity [m/s] Headloss DN300 Valve Slip-in unibody elastomeric check valve1'' WaStop 90 0 50 0 150 00 50 0.0 0.5 1.0 1.5.0.5 3.0 FIG. 4 HEAD LOSS COMPARISION BETWEEN A COMPETING INLINE CHECKVALVE AND THE WASTOP (SI-UNITS).

Page 8 of 11 16.0 Headloss 1'' Valve Slip-in unibody elastomeric check valve 1'' WaStop 90 14.0 1.0 [ft H0].0 8.0 6.0 4.0.0 0.0 Flow [GPM] Pipe Velocity [fps] 0 500 00 1500 000 500 3000 3500 0 4 6 8 FIG. 5 HEAD LOSS COMPARISION BETWEEN A COMPETING INLINE CHECKVALVE AND THE WASTOP (US-UNITS) CONCLUSION The material choices in the design of a check valve are of high importance. The valve body needs to be rigid allowing a good seal between the membrane and the body, but also thin to not decrease the hydraulic area of the pipe more than necessary. The membrane needs to be elastic to regain its shape after many deformation cycles and still resistant to chemicals and wear and tear. The geometry of the membrane should allow flow with minimum head loss in one direction and be able to withstand high backpressures in the other direction. When comparing head loss data one need to make sure first of all that the data is comparable. That the same or similar test setup and procedure was used and datum points are the same. Furthermore the head loss data presented in this paper is the total head loss for an outlet including a WaStop. In some situations as an example a submerged discharge, before the addition of a WaStop, the outlet has a loss coefficient equal to one. Hence the additional head loss introduced by the WaStop would be: _ =, 1. Same reasoning applies to all inlets/outlets already including some head loss before the addition of a Wastop, warranting some consideration before choosing a product preventing reverse flow.

Page 9 of 11 000 Head loss WaStop Open Air [mmwc] 00 90 390 590 985 1485 0 1 0 00 000 FIG. 6 OPEN AIR HEAD LOSS Flow [l/s] 0 Head loss WaStop Open Air [ftwc] 1 0 00 000 0000 90 390 590 985 1485 0.1 FIG. 7 OPEN AIR HEAD LOSS (US) Flow [GPM]

Page of 11 000 Head loss WaStop Submerged [mmwc] 00 0 90 390 590 1 0 00 000 FIG. 8 SUBMERGED HEAD LOSS Flow [l/s] 0 Head loss WaStop Submerged [ftwc] 1 0 00 000 0000 90 390 590 0.1 FIG. 9 SUBMERGED HEAD LOSS (US) Flow [GPM]

Page 11 of 11 K L WaStop open air WS90 WS390 WS590 WS985 WS1485 K L - Loss coeff. 0 18 16 14 1 8 6 4 0 0 1 3 4 5 Velocity [m/s] FIG. KL WASTOP OPEN AIR K L WaStop submerged WS90 WS390 WS590 K L - Loss coeff. 0 18 16 14 1 8 6 4 0 0 1 3 4 5 Velocity [m/s] FIG. 11 KL WASTOP SUBMERGED