O3 3E 1 F Gas Sensor Module

Similar documents
Sensoric 4-20 ma Transmitter Board Operation Manual

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Ozone. Sensoric O3 3E 1

SPECIFICATION. date of manufacture. Intermittent: -20 o C to +50 o C. Pressure Range:

Phosgene Sensor. Sensoric COCl2 3E 1

OP08 - Electrochemical 3-Electrode Un-biased Toxic Sensors CONTENTS. Introduction 2. Operating Principles 2. Recommended Circuitry 4.

Datasheet: K-30 ASCII Sensor

MODEL GT820 OXYGEN SENSOR

ASDX Series Silicon Pressure Sensors

All Sixth Sense cells for toxic gas detection are based on electrochemical principles and can be classified as amperometric fuel cells.

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

Model B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

GasSense NDIR User Manual

Operating Instructions

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual

User Manual. PolyGard AT-1130 V3. Electrochemical Nitrogen Dioxide Transmitter. July, 2011

Technical Data Sheet MF010-O-LC

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

User Manual. µ-gard MD Electrochemical Carbon Monoxide Transmitter Serial No. MD April, 2011

HLM-2000-TX Gas Transmitter User Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Operation Manual. Rev. C LPT Low Power Transmitter (Electrochemical Sensor)

Operation and Maintenance Manual

HLM-2000-TX Gas Transmitter User Manual

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

GasLab SAN-102 Micro Oxygen Monitor User Manual

CALIBRATION KIT. Instruction Manual

User Manual. PolyGard DT V4. Electrochemical Carbon Monoxide Transmitter Serial No. DT December, 2008

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

MEC OEM. User Manual. Commercial in Confidence

Auto-Zero Calibration Technique for Pressure Sensors

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

Application Note AN-107

PRELIMINARY DATASHEET

Installation and Operation Manual

RAM 4021 Operation Manual

Instruction and Maintenance Manual

Specifications of Oxygen Sensor Module V-8344A

Nemoto Sensor Engineering Company Ltd

AMS 2710 PCB pressure sensor module with V output

Calibration Requirements for Direct Reading Confined Space Gas Detectors

GasLab SAN-102 Micro Oxygen Monitor User Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

with O 2 Controller Instruction Manual

Columbus Instruments

BI-680 Online Dissolved Oxygen Controller Instruction Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Advanced Test Equipment Rentals ATEC (2832)

RAM Operation Manual

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Nemoto Sensor Engineering Company Ltd

User s Guide Temperature Sensor Converter TSC-599

RAM 4021-DPX Operation Manual

Electrochemical Sensor

DESCRIPTION FEATURES

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

HI 2314 HI 2315 HI 23151

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Instruction and Maintenance Manual

BAPI Pressure Line of Products - FAQs

Electrochemical Sensor

Operating Instructions Part No

AMS 6916 Board mount pressure sensor with ratiometric analog output

Electrochemical Carbon Monoxide Gas Sensor (Model:ME3-CO) Manual. Version 1.2 Valid from May 1 st 2014

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

210 Series Transmitter with External Electrochemical Sensor

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

O2100C Oxygen Measurement Module Technical Use Notes do not use other wall adapters with the O2100Cmodule. 10% / V 5% / V 2% / V 1% / V 10% / V

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

! Warning, refer to accompanying documents.

USER'S GUIDE. Digital Barometers with Analog Output PTB210 Series M210670EN-B

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

PTB210 Series Digital Barometers with Analog Output USER'S GUIDE

DPC-30 DPC-100. Reference Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Precision pressure sensor Basic version Model CPT6020

Basic Board Mount Pressure Sensors. Datasheet

ME3-HCL Electrochemical sensor

EC214 EC215 - EC215R Bench Conductivity Meters

Model FS5001B VA.1. MEMS Mass Flow Sensors ISO 9001 ISO OHSAS 18001

Digital Vacuum Regulator

Operation manual Oxygen sensor

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

Air Check Lite Toxic Gas Monitor

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

SX150A. Features. Typical Applications. Description

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

The Univentor 1250 Anaesthesia Unit

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Installation and Operation Manual

Transcription:

Product Information Pack O3 3E 1 F Gas Sensor Module (Ozone) CONTENTS Product Data Sheet Product Specification 2 Poisoning and Cross Sensitivities 3 Operating Instructions Introduction 4 Electrostatic Discharge Guidelines 5 Mounting Orientation 5 Connection and Wiring 5 Error Conditions 6 Calibration Guidelines 6 Handling and Storage 8 Scope and Purpose of Document The purpose of this document is to present the performance specification and operating instructions of the O3 3E 1 F Gas Sensor Module. All information required for the correct use of the Gas Sensor Module is included in this document. For Product Safety Datasheets (PSDS), REACH and RoHS information, please visit www.citytech.com. The data provided in this document are valid at 20 C, 50% RH and 1013 mbar. Output signal can drift below the lower limit over time. Doc. Ref.: o33e1f Module.indd Issue 3 ECN I 171115b Page 1 of 8

Product Data Sheet Key Features & Benefits: Industry standard 4-20 ma output 40-200 mv option Technical Specifications Product Dimensions Target Gas Operating Principle Measurement Range Filter Output Response Time T 50 T 90 Resolution Linearity MEASUREMENT ) 3-electrode electrochemical 0.1-1 ppm O 3 Dust filter only 4-20 ma, 2 wire loop powered 40-200 mv <15 Seconds <60 Seconds 0.01 ma <10% of full scale Power Supply Required Maximum Loop Resistance Calibration ELECTRICAL 10-30 VDC single-ended 700 Ω Via PCB mounted button and potentiometer Mounting Weight Sensor Housing Material MECHANICAL Via 3mm PCB mounting holes <13 g Noryl All dimensions in mm All tolerances ±0.15 mm unless otherwise stated ENVIRONMENTAL Operating Temperature Range -20 C to +40 C Recommended Storage Temp 4 C to 10 C Operating Humidity Range 15% to 90% rh non-condensing LIFETIME Long Term Output Drift Expected Operating Life <5% per month 18 months in air Specifications are valid at 20 C, 50% RH and 1013 mbar. Doc. Ref.: o33e1f Module.indd Issue 3 ECN I 171115b Page 2 of 8

Product Data Sheet Poisoning These sensors are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation. When using Gas Sensor Modules with printed circuit boards (PCBs), degreasing agents should be used before the module is fitted. Do not glue directly on or near the modules as the solvent may cause crazing of the plastic. Cross Sensitivity Table Whilst these sensors are designed to be highly specific to the gas they are intended to measure, they will still respond to some degree to various other gases. The table below is not exclusive and other gases not included in the table may still cause a sensor to react. IMPORTANT NOTE : The cross sensitivity data shown below does not form part of the product specification and is supplied for guidance only. Values quoted are based on tests conducted on a small number of sensors and any batch may show significant variation. For the most accurate measurements, the Gas Sensor Module should be calibrated using the gas under investigation. Gas Concentration Used Reading (ppm O 3 ) Bromine, Br 2 - yes - no data Iodine, I 2 - yes - no data Carbon Dioxide, CO 2 5000 ppm 0 Carbon Monoxide, CO 100 ppm 0 Chlorine, Cl 2 1 ppm 1.2 Chlorine Dioxide, ClO 2 1 ppm 1.5 Hydrazine, N 2 H 4 3 ppm -3 Hydrogen, H 2 3000 ppm 0 Hydrogen Sulfide, H 2 S 20 ppm -1.6 1 Nitrogen, N 2 100%vol 0 Nitrogen Dioxide, NO 2 10 ppm 6 1) Continuous exposure to more than 30 ppm H 2 S may blind the sensor Doc. Ref.: o33e1f Module.indd Issue 3 ECN I 171115b Page 3 of 8

Product Operating Instructions Introduction The Gas Sensor Module provides easy to use connectivity and output, compactness, and ease of calibration for most life safety and environmental monitoring applications. It provides a calibrated 4-20 ma output as well as a 40-200 mv signal output. Features: Fully calibrated 4-20 ma (and 40-200 mv) output for each target gas; Linear output across detection range; Power in / output out, no setup required; Board allows user to calibrate gas sensor against target gas; Equipped with four mounting holes for prototyping. All Gas Sensor Modules can be mounted via four 3 mm mounting holes in the PCB. Gas Sensor Module Features The Gas Sensor Module is shipped calibrated to a 4-20 ma output. There are two options for recalibration: by use of the PCB mounted calibration button (for zero and span calibration); by use of the potentiometer (for span calibration). The PCB incorporates on-board temperature compensation and allows the use of an optional external temperature sensor. Doc. Ref.: o33e1f Module.indd Issue 3 ECN I 171115b Page 4 of 8

Product Operating Instructions Electrostatic Discharge Guidelines This component is susceptible to Electrostatic Discharge (ESD) when being installed or adjusted. To prevent ESD related damage during installation, the following guidelines should be considered: Ensure all power supplies are turned off; Wear an ESD strap connected to ground or discharge yourself by touching a metal part of the equipment into which the module is being installed; Ensure that any tools are discharged by contacting them against a metal part of the equipment into which the Gas Sensing Module is being installed; When adjusting potentiometers, with power applied, use an appropriate potentiometer adjustment tool or a small insulated screwdriver. Mounting Orientation Gas Sensor Modules should be installed with the sensor gas inlet side pointing downwards. The minimum requirement is to install the sensor with the sensor's gas inlet in a horizontal direction. It is not advisable to install the sensor with the gas inlet side permanently pointing upwards. Connection and Wiring The Gas Sensor Module is designed for standard two-wire operation, where the 4-20 ma output is supplied via the same wire pair as the power supply. The external circuit loop is connected to the transmitter PCB via the screw terminal connector - see below. The connector can be used in two orientations - vertically or horizontally. The Gas Sensor Module offers reverse polarity protection, so the power supply can be connected in either direction. The sensor only requires a few seconds to settle after power is applied. In addition to the 4-20 ma signal in the 2-wire loop, a 40-200 mv voltage output is also available. Operational status can be retrieved by pressing and holding the calibration button for between 0.5-3.0 seconds. The blinking pattern of the LED shows the calibration status, as follows. 1 blink : Factory settings (as delivered) 2 blink : Individual settings (recalibrated) 3 blink : Factory settings after reset Doc. Ref.: o33e1f Module.indd Issue 3 ECN I 171115b Page 5 of 8

Product Operating Instructions Error Conditions In normal use, the Gas Sensor Module output will remain within the range of 4 ma (for zero gas) and 20 ma (for span gas). An output of 0 ma represents a fault on the circuit board. Other error conditions are signalled by the module output going to 21 ma. Error conditions recognised by the board are as follows: Output dropping below 3.8 ma; Output rising above 20.5 ma; The board is used at temperatures more than 5 C outside of its temperature specification. Calibration Guidelines The Gas Sensor Module is calibrated before shipping to the customer. It provides a stable signal over its standard life and for many applications, only requires occasional recalibration. The time interval required between initial calibration and subsequent recalibrations depends on various factors. In strenuous applications involving extremes of operation, or for sensors used in safety applications, frequent calibration may be required. Calibration Period Calibration is required if the deviation of the measured value is outside the limits required by the application. Calibration Gas Concentration For maximum accuracy, the Gas Sensor Module should be calibrated using a gas concentration in the range where most measurements are to be made. Where this is not possible, a concentration towards the top of the measurement range should be chosen. Calibration gases exceeding the measurement range must not be used as this may not provide an accurate calibration. Electrochemical gas sensors need a certain amount of oxygen to function. Generally, a few thousand ppm oxygen is sufficient. However, as calibration only involves a short exposure to gas, the calibration gas need not contain oxygen - sufficient is supplied from the ambient air for a limited time. In most cases, a five minute exposure time is sufficient to achieve a stable calibration signal. However the sensor should not be completely potted with resin or totally immersed in an anaerobic gas mixture for long periods as this can affect the sensor's performance. Calibrating to Cross Sensitive Gases Electrochemical sensors are cross sensitive to certain non-target gases. Cross sensitivity data is only approximate and cross sensitivities will vary between sensors and sensor batches. Calibrating Gas Sensor Modules to non-target gas will result in measurement errors and is not advised. Doc. Ref.: o33e1f Module.indd Issue 3 ECN I 171115b Page 6 of 8

Product Operating Instructions Recommended Gas Flow Rates A minimum flow rate is required to ensure accurate calibration. The minimum flow rate is dependant on the gas type. Gas Type Minimum Flow Rate (ml/min) Ammonia, NH 3 250 Carbon Monoxide, CO 150 Hydrogen, H 2 150 Hydrogen Sulfide, H 2 S 250 Nitrogen Dioxide, NO 2 250 Ozone, O 3 250 These flow rates are based on gas delivery apparatus used by City Technology. Other designs of gas delivery may have an influence on the flow rates required. User Calibration Procedure Note that warranty on calibration is lost once a recalibration is performed. Zero Reading Calibration Connect and apply power to the Gas Sensor Module. Allow the sensor to stabilize for a minimum of 5 minutes in clean air. Once the output signal is stable, press and hold the calibration button for between 6 and 12 seconds. The LED acknowledges calibration by blinking 6 times. Span Calibration Via calibration button Apply calibration gas to the sensor at the appropriate flow rate for a minimum of 5 minutes. Once output signal is stable, press and hold the calibration button for between 12 and 60 seconds. The LED acknowledges calibration by blinking 8 times. Remove gas and reapply clean air. Via potentiometer Apply calibration gas to the sensor at the appropriate flow rate for a minimum of 5 minutes. Once output signal is stable, set the output to the appropriate value by adjusting the potentiometer. Remove gas and reapply clean air. Factory Reset Press and hold the calibration button for between 3 and 6 seconds. The LED acknowledges the factory reset by blinking 4 times. Doc. Ref.: o33e1f Module.indd Issue 3 ECN I 171115b Page 7 of 8

Handling and Storage Gas Sensor Modules are relatively insensitive to mishandling and following the simple guidelines given below should ensure correct operation. Gas Sensor Modules must not be exposed to temperatures outside the range -55 C to +60 C. Modules should be stored in their original sealed packaging within the temperaure range of +4 C to 10 C with the sensor membrane faced downwards. Gas Sensor Modules should not be stored, assembled or used in areas containing solvent vapours. Exposure to solvents will result in performance degradation and premature sensor failure. Exposure of modules to alcohol containing antiseptic products such as wipes and sanitizing gels should be avoided. Modules can respond to the alcohol based solvents and generate an output, which could manifest itself as an exaggerated baseline signal or prolonged recovery time. Gas Sensor Modules must not be subjected to any pressure when handling or clamping. To avoid damage to the sensing face of the sensors, Gas Sensor Modules must not be stacked on top of each other. At the end of its life, the product should be disposed of in accordance with local regulations. The hazardous waste disposal regulations depend on geographic location, and local regulations should be checked before discarding sensors. SAFETY NOTE This module is designed to be used in safety critical applications. To ensure that the Gas Sensor Module and/or instrument in which it is used are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check) before each use of the module and/or instrument. Failure to carry out such tests may jeopardize the safety of people and property. Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with the company s policy of continued product improvement, Life Safety Germany GmbH reserves the right to make product changes without notice. The products are always subject to a programme of improvement and testing which may result in some changes in the characteristics quoted. As the products may be used by the client in circumstances beyond the knowledge and control of Life Safety Germany GmbH, we cannot give any warranty as to the relevance of these particulars to an application. Life Safety Germany GmbH warrants goods of its manufacture as being free of defective materials and faulty workmanship. Life Safety Germany GmbH's standard product warranty applies unless agreed to otherwise by Life Safety Germany GmbH in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned during the period of coverage, Life Safety Germany GmbH will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Life Safety Germany GmbH be liable for consequential, special, or indirect damages. It is the clients responsibility to carry out the necessary tests to determine the usefulness of the products and to ensure their safety of operation in a particular application. While we provide application assistance personally, through our literature and our web site, it is up to the customer to determine the suitability of the product in the application. Doc. Ref.: o33e1f Module.indd Issue 3 ECN I 171115b Page 8 of 8