Job Sheet 1. Geothermal Energy

Similar documents
Heat Pump Connections and Interior Piping

The Discussion of this exercise covers the following points:

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

FAULT CODE TROUBLESHOOTING INDEX

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

LENNOX SLP98UHV DIAGNOSTIC CODES

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

WATER CONTROL SYSTEM QUICK START

BUBBLER CONTROL SYSTEM

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

The Discussion of this exercise covers the following points: Range with an elevated or suppressed zero Suppressed-zero range Elevated-zero range

Exercise 3-2. Two-Wire and Three-Wire Controls EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Two-wire control

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

UNLOADING PROCEDURE OF AN AIRFLOW CONTAINER

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

SIP 1000 OPERATION AND PROGRAMMING MANUAL

DASSAULT AVIATION Proprietary Data

1.2 Example 1: A simple hydraulic system

Start up XXX from normal shutdown Introduction

Refrigeration and Air Conditioning Technical leaflet

OPERATION MANUAL. For the PARU01. Underwater Plasma Cutting. Supervisors Remote Panel

Operating Manual. Model BAC-30RT30/BAC-30DC

GW DRY PIPE VALVE INSTALLATION & OPERATION 100mm (4 ) 150mm (6 )

CP3R Quick Start Manual

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

CPN1 Quick Start Manual

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

KIT. Small Automatic Water Boosters KIT MODELS

FX134, FX1234, FX3030 Problem and Solutions

BUBBLER CONTROL SYSTEM

SILENTAIRE TECHNOLOGY

DPC-30 DPC-100. Reference Manual

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Portable Oil Lube Air Compressors

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

1. Study the performance of a binary distillation column operated in batch mode.

E X T E R I O R L I V E P R O P A N E F I R E P R O P P R O C E D U R E S F O R U S I N G T H E P R O P A N E P R O P

Basic Pneumatics. Module 7: Time delay valve and sequence control systems. Academic Services PREPARED BY. January 2013

AIR CONDITIONING AND PRESSURIZATION CONTROLS AND INDICATORS

The Discussion of this exercise covers the following points:

Manual for continuous distillation

A/C SYSTEM DIAGNOSIS

Propane Conversion Kit Instructions

NOTICE. Issued: February 12, 2010 AO# Dundas Street West, Oakville, ON CANADA Phone: (905) Fax: (905)

Minimum standard of competence in advanced training for liquefied gas tanker cargo operations (STCW Reg V/1-2)

TECHNICAL DATA. Dry 132a. October 1, 2008

Installation, Operation & Maintenance Instructions

SILENTAIRE TECHNOLOGY

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Industrial Pneumatics

R E D I C O N T R O L S

HOT SERIES (High Output Temperature) Geothermal Water to Water Heat Pump R-134A Refrigerant 2 Ton to 20 Ton Single Speed

Reverse Osmosis System Installation Guide and Operation Manual.

Accessories. Valves. Adjustable Pressure Relief Valves

LPG LEVEL GAUGE /INDICATOR manual

Project Title: Pneumatic Exercise Machine

Basic Pneumatics. Module 9: Time delay valve. Academic Services PREPARED BY. April 2012

Reclaim Basic Set Up

VARIOspeed 3R User Manual

Cover Page for Lab Report Group Portion. Pump Performance

Prestige Solo Prestige Excellence 24-32

Experiment Instructions. Circulating Pumps Training Panel

Gas Absorption Column CAG

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

SEPARATION SYSTEMS. Separator (MBD-1600) or the Wet Oil Tank, (ABJ-1800). Water is

NGP-250/500 Nitrogen Generator Quick Start Guide

COMPRESSOR MANUAL. (888)

Operating Manual. Model 25200B/25202B Refrigerant Recovery Unit. (Not for use in automotive R-134a applications)

KKT Training Series: ECO Series, Preventative Maintenance

Operating Procedures for Metal Evaporator I

Section - III SYSTEMS DESCRIPTION

Kelsow Work Instruction. Subsea Well Control Hydraulic Panel Operation

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

OPERATING INSTRUCTIONS

ScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m

Eco Snow CO2 Clean System Operation

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

TECHNICAL DATA. Q = C v P S

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

INSTALLATION GUIDE Gas Rangetops

CCT-7320/ROC-2313 Reverse Osmosis Controller

UNIVERSITY OF WATERLOO

Dynamic Simulation for T-9 Storage Tank (Holding Case)

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

How many intakes can I operate from the control center? Up to 4 intakes can be controlled from the control center.

Time-Delay Electropneumatic Applications

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Twin & Triple Control Concealed Thermostatic Shower Valve

TotalPac X Single interlock Preaction system Electric release

Product Range. High performance and economic high pressure solutions Made in Germany

Transcription:

Job Sheet 1 Geothermal Energy OBJECTIVES In this job sheet, you will become familiar with the training system components. You will operate your training system in heating and cooling mode and observe the temperature at various locations on the system. PROCEDURE Familiarization with the training system components In this part of the job sheet, you will locate and identify some training system components. 1. Identify the highlighted zones in the training system diagram of Figure 15. Record your answers in the table below. Festo Didactic 88271-20 17

Circled letter A B C D E Component Figure 15. Training system diagram. 18 Festo Didactic 88271-20

2. Locate the priming tank (Figure 16) on your training system. Observe the current position of the three-way valves. In the rectangle to the right of the image, draw the diagram corresponding to the position of the three-way valves. Priming tank 3-way valves Pumping station Pump nameplate Figure 16. Priming tank and pumping station. 3. Locate the pumping station. Read the electrical characteristics indicated on the pump nameplate and complete Table 2. Table 2. Electrical characteristics of the pump. Parameter Voltage Frequency Current Number of phase Nameplate data 4. Locate the following indicator lights on the Geothermal Heat Pump control panel: Loop pump Reversing valve Festo Didactic 88271-20 19

Compressor Desuperheater Heat pump fault Circulation pump 5. Which ranges and units can the loop pressure gauge (PI-1) read? 6. What information can be read on the refrigerant high-pressure (HP) and low-pressure (LP) gauges located on the right side of your training system? Temperature at various locations on the training system in heating mode In this part of the job sheet, you will operate your training system in heating mode and observe the temperature at various locations. a In many job sheets throughout this manual, you will have to set switches, valves, the thermostat, and the air distribution register to achieve specific operating conditions required by the topics covered. In each case, you will be supplied with a list of components and the required settings. For instance, in the following list, the main power switch must be set to Off. 20 Festo Didactic 88271-20

7. Perform the following settings: Main power switch... Off Thermostat... Heating mode Temperature set point... 5 C (9 F) above room temperature Valve HV-1... Open Valve HV-2... Open Valve HV-3... Open Valve HV-4... Open Valve HV-5... Open Valve HV-6... Open Valve HV-7... Open Valve HV-8... Closed Valve HV-9... No adjustments required Valve HV-10... Handle in horizontal position Valve HV-11... Open Valve HV-12... Open Valve HV-13... Open Pressure gauge PI-1 selector switch... Right Pressure gauge PI-2 selector switch... Right Desuperheater On/Off switch... Off Priming tank three-way valves... Pumping station three-way valves... a Air distribution register (on top of the heat pump)... Open Heat pumps have several protection devices and do not start immediately when power is turned on. The blower and the ground loop pump may be running before the heat pump turns on. 8. Turn the system on by setting the main power switch to On. Immediately feel the temperature at the various locations identified by a circled letter in Figure 17 by touching the components with your hands. Record your observations using the terms cold, room temperature, warm, and hot in the At start up column of Table 3. After a while, the compressor starts and the corresponding indicator light on the control panel turns on. Wait until the compressor has been running for ten minutes, and then repeat your temperature observations. Record your observations in the After 10 minutes of operation in heating mode column in Table 3. Festo Didactic 88271-20 21

Figure 17. Locations where the temperature must be sensed. Table 3. Sensed temperatures in heating and cooling modes. Location (circled number in Figure 17) At start up After 10 minutes of operation in heating mode Temperature At the moment when the mode is set to cooling After 10 minutes of operation in cooling mode A B C D E F G 22 Festo Didactic 88271-20

9. Using the words On or Off, record the control panel indicator light status in the Heating mode column of Table 4. Table 4. Indicator light status in heating and cooling modes. Indicator light Heating mode Cooling mode Loop pump Compressor Desuperheater pump Reversing valve Circulation pump Heat pump fault 10. Is the air temperature near the air distribution register (G) warmer than the air temperature near the heat pump air intake (F)? 11. Did the water in the ground simulation tank (C) change temperature after ten minutes of compressor operation? 12. Did the temperature of the water flowing through the ground loops increase or decrease after ten minutes of compressor operation? Festo Didactic 88271-20 23

Temperature at various locations on the training system in cooling mode In this part of the job sheet, you will operate your training system in cooling mode and repeat your temperature observations. You will compare your observed temperatures in heating mode and cooling mode. 13. Perform the following settings on your training system: Main power switch... Off Thermostat... Cooling mode Temperature set point... 5 C (9 F) below room temperature Valve HV-1... Open Valve HV-2... Open Valve HV-3... Open Valve HV-4... Open Valve HV-5... Open Valve HV-6... Open Valve HV-7... Open Valve HV-8... Closed Valve HV-9... No adjustments required Valve HV-10... Handle in horizontal position Valve HV-11... Open Valve HV-12... Open Valve HV-13... Open Pressure gauge PI-1 selector switch... Right Pressure gauge PI-2 selector switch... Right Desuperheater On/Off switch... Off Priming tank three-way valves... Pumping station three-way valves... Air distribution register (on top of the heat pump)... Open 14. Turn the system on by setting the main power switch to On. Immediately feel the temperature at the various locations identified by a circled letter in Figure 17 by touching the components with your hands. Record your observations using the terms cold, room temperature, warm, and hot in the At the moment when the mode is set to cooling column of Table 3. After a while, the compressor starts and the corresponding indicator light on the control panel turns on. Wait until the compressor has been running for ten minutes, and then repeat your temperature observations. Record your observations in the After 10 minutes of operation in cooling mode column in Table 3. 24 Festo Didactic 88271-20

15. Using the words On or Off, record the control panel indicator light status in the Cooling mode column of Table 4. 16. Compare your observations in heating and cooling modes recorded in Table 3. Where did the temperature change from warm to cold, and from cold to warm? 17. When you changed the operating mode to cooling, did the reversing valve indicator light turn on or turn off? 18. Based on your answer to the previous question, would you say that the default operating mode of your training system is heating mode or cooling mode? 19. Set the thermostat operating mode to Off, then shut down your training system by setting the main power switch to Off. Name: Date: Instructor's approval: Festo Didactic 88271-20 25