Working correctly with gas

Similar documents
Technical Bulletin AL-134

ARC Unofficial Manual to the Solvent Dispensing System. Designed by J. C. Meyer

DEMONSTRATION 2.1 PROPERTIES OF CO 2. Chapter 2: Gases

How to use Solvent Purification System A brief manual

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

BS ml Bottle Sampling Unit

Standard Operating Procedure (SOP)

PREPARATION AND PROPERTIES OF ATMOSPHERIC GASES I: Carbon Dioxide and Oxygen

VOLUMETRIC TECHNIQUES

The Safe Use of Pyrophoric Substances

Electron Microscopy Centre

Agilent 1290 Infinity Pump Head Maintenance

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

School of Chemistry SOP For Operation Of Glove Boxes

2008 by Controlmatik ABW

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

LABORATORY TECHNIQUES. Pouring Liquids

Procedure for Filling 2 T Bruker Magnet with Nitrogen

Instructions for use Compressed air injector with water trap

Solvent System Walkthrough

Filtration FILTRATION PRODUCT TIPS

Experiment 18 Properties of Gases

MB-SP Series Solvent Purification System

Calcimeter Instruction Manual

HGC-200 Hydro Gas Chlorinator

Figure. Experimental set up of catalyst, reactants and product syringes.

Determination of the Gas-Law Constant (R) using CO2

Figure 1. Basic vacuum/inert gas manifold (Adapted from chemistryviews.org)

Gas Laws. Figure 1: Experimental Set-up with Leveling Bulb. GCC CHM 151LL: Gas Laws GCC, 2019 page 1 of 8

Overhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012.

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

Installation Instructions for NP100 Series Nitrogen Control Panels

Using the Akta Prime plus October 22, 2012

Question McGraw-Hill Ryerson Limited

Properties of Gases Observing Atom Pressure of a Gas Measuring Gas Products of Chemical Inferring Molecule Reactions

Contact Person(s) : Isabel M. Fisenne APPLICATION

Part 1: Distillation and Analysis of an Unknown Alcohol Mixture

Chemistry 261 Laboratory Experiment 6: Reduced Pressure Distillation of a Mixture of High Boiling Alcohols

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Training. Testor Training Manual

Lab-Specific Standard Operating Procedure (LSOP)- Pyrophoric Chemicals

Columbia Taping Tools. Hydra Reach Handle. Manual

1 of 5. Functionn. HTHP mud. measuree. of the filter. when the Power. Structure

POOL ROVER ST POOL CLEANER Installation Instructions

Accidents with alkali metals

Perfusion-Fixation of Adult Rat Brain

INSTALLATION INSTRUCTIONS

Funsheet [WHAT IS PRESSURE AND TEMPERATURE] Gu 2015

Variable Temperature Operation

Making OTR Measurements in Bottles using the. BottlePerm Fixture

Basic Flows in a Microfluidic Device

Manual Solvent Purification System. Innovative Technology, Inc.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

19. The Grignard Reaction

User Manual. Quantos Automated Dosing Liquid Module

Navigator 600 Silica analyzers

T004.BioTector TOC Analyzer Pressure and Flow Test failure analysis

Hydrogen Cyanide (HCN)

NRES Procedures for Lab-based Projects and Research

User Manual. Quantos Automated Dosing Powder Module

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

MODEL 1329 Tank Gauge

User s Guide. Vacuum Controller for liquid delivery systems

LNG Regulator Test Kit

Solvent Dispensing System Manual. Designed by J. C. Meyer

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

ExamLearn.ie. The Air & Oxygen

CHEM254 #4 The Synthesis of a Tertiary Alcohol Using a Pre-Made Grignard Reagent 1

OPERATING MANUAL LO-CROSS-FLOW CF M

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

Lab: Safety Due: Lab # 0

POLYMER TEST KIT (CLAPPER METHOD) OFI PART No

V-24 OXYGEN LANCE VALVE

SRI Model H2-40 Hydrogen Generator Operation and Maintenance Nov 2006

Chemical Injection Technologies Installation/Service Bulletin

Ammonia Treatment Instructions Page 1 of 5

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Safety instructions and operating manual

Blue Thumb Test Procedures

Welcome to the Specialized Medical Services Respiratory training webinar series!

Standard Operating Procedure

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8.

MS.RAJA ELGADY/PRESSURE PAPER 3

Operate Breathing Apparatus

A) It cannot be predicted. B) It is squared. C) It is doubled. D) It is halved. E) It does not change.

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Lab Equipment ANALYTICAL BALANCE

UltRo Dual Flow Reverse Osmosis Water System

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Instruction Manual Updated 6/22/06 Ver. 2.0

1. Introduction Why use the Flow-Through Cell? Component Identification... 1

Safe Use of Solvent Stills

Instruction Manual Updated 7/26/2011 Ver. 2.2

General Safety Rules

1. The Safe Use of Pyrophoric Reagents

Transcription:

Working correctly with gas When working with a reactive gas in a cylinder, there is an inherent risk. Special care has to be taken to allow safe handling. This example is with HCl. 1) Fixing the gas bottle. The first step in all reaction involving gas is a safe fixing of the bottle. In addition, a safety empty flask is added between the gas bottle and the reaction flask. This flask should have a volume larger than the reaction flask. safety flask reaction flask fixation 2) Preparation of the glassware After the safety flask, a three-neck reaction flask is prepared: two necks for gas inlet and outlet, and one Neck to add solvents and reagents. If the reaction is very water sensitive, it is then connected to two washing bottles containing a drying agent (CaCl 2 in the case of an acid gas). Finally, two washing bottles are added to neutralize the gas (in the case of HCl, a 4M NaOH solution). Extreme care has to be taken to connect the washing bottle the right way (see picture): In no case should the washing liquid be able to be sucked inside the tubing!

2) Preparation of the gas connection In preparation for the gas connection, first put all the glassware under nitrogen. Remove the protecting cap of the bottle and install the correct adaptor (!!! adaptors are out of different metals depending of the gas, be sure to check with the technician if you have the right one!!!). Connect the adaptor tightly using the correct tool (hand is not enough). Install a three-way connection just after the bottle: one to the nitrogen line, one to the reaction via the safety flask, one to the gas bottle. In the reaction flask, connect the gas tube to a glass connector equipped with a gas repartition fritte. Use a screwable connector with a O-ring joint to fit the glass tube to the reaction flask. Secure all tubing under pressure with clamps. Test then the complete apparatus with a nitrogen flow.

Glass Tube connector Correct adaptor O-ring connector 3 ways connector gas fritte

3) Adding solvent and reagents Add solvent or reagents using standard technique. Here a dry solvent was added via canula using the overpressure of an Ar balloon. This can be done true septa via a Teflon tube. The solvent is filtered through a glass fritte during transfer. 4) Turn on the gas 1) Check that the secondary valve is closed. 2) Open the main valve completely. Be ready to close it immediately if the system is not tight. 3) Switch the 3-ways connector to connect the gas bottle to the reaction flask (be careful not to send the gas to the line! Be always careful to have an open system, else there is a big risk of overpressure!). 4) Open slowly the secondary valve on the bottle. Be careful: some valves are not very sensitive, and the gas flow can go from nothing to relatively strong rapidly. 5) As soon as the gas come out, insert the gas inlet into the solvent, modulate bubbling with the valve. Check also bubbling out of the washing bottle. main valve secondary valve To the reaction 5) Monitor the reaction Check continuously the temperature of the reaction mixture and the washing bottle, if required, cool them down with ice. Check that there is a constant but slow bubbling in the reaction flask and the wash bottle. Check with ph paper if the wash bottle is still basic.

6) Stopping the reaction 1) Remove the gas inlet from the solvent 2) Close the secondary valve. Close the main valve 3) Immediately turn the 3-ways connector to let the nitrogen of the line enter the reaction system. 4) Flush with nitrogen for at least 30 min. 5) Be careful when removing the adaptor from the bottle (gloves, visage protection) as a tiny amount of gas will still come out. Let the hood on urgency for some time. Screw the protecting cap back on the bottle. Remove the bottle from the hood.