Aespire 7100 Essential performance Compact design

Similar documents
Innovating with you Shaping exceptional care

Carestation 650. Physical Specifications Product Description Carestation 620 A1 ANESTESI CARESTATION 650

Carestation 620. Key Features. Ventilation. Design

Carestation 650. Key Features. Design. Ventilation

Carestation 650c. Key Features. Design. Ventilation

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

S/5 Aespire. Quick Reference Guide

A9600 Anesthesia Workstation. Your healthcare, we care.

Flow meter. bellow vaporizer. APL valve. Scavenging system

GE Healthcare. Aestiva/5. More than superior ventilation

Anesthesia Workstation

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Safe Accurate Reliable. CWM-301 Anesthesia System

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

GE Healthcare. Avance Carestation. Upgrade promotions guide

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

The centerpiece of a comprehensive anaesthesia workstation

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

The anaesthesia workstation focused on you

Aestiva/5. Operation Manual - Part 1. Software Revision 4.X System Controls, Operation, Checkout

Anes Machine Use and Pre-use Check - CA1 focus

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

PERSEO EVOLUTION. workstation for gaseous anaesthesia. for adults, children and newborns. Code: OM 403 / 3 gas module 3 rotameter

The anaesthesia workstation focused on you

Hallowell EMC Anesthesia WorkStation Operating Manual

Draeger Fabius GS Pre-Use Check

Anesthesia Machine Intro

Recommendations on Checking Anaesthesia Delivery Systems

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Your patients, our primary focus. Siesta i Whispa anesthesia machine

DATA SHEET. VENTILATION SERVO-s

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the

Your patients, our primary focus

State-of-the-art anesthesia technology

DATA SHEET. ANESTHESIA SYSTEM FLOW-i

AUTOVENT 4000 VENTILATOR

APUS Anesthesia Machines

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Panther 5 Acute Care Ventilator

Service Manual. Anesthesia System ANESTHESIA S ANESTHESIA SYSTEM

Anesthesia Delivery Systems What Do I Need to Know About My Machine? A Workshop James H. Philip, MEE, MD, CCE

The SAV04 Small Animal Ventilator. Contents Page

Prima SP2/3 Anaesthetic Machine Range Service Manual Partnership for Life

VT650. Gas Flow Analyzer. Technical data. Key benefits and features:

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

VT900. Gas Flow Analyzer. Technical data. Key benefits and features:

BleaseFocus Anesthesia System VERSATILE ANESTHESIA

V8800 Ventilator System. Your healthcare, we care.

THE GE AISYS ANAESTHETIC MACHINE

Operation and Maintenance of the EPV200 Portable Ventilator

New Anesthesia Delivery Systems What Do I Need to Know About My New Machine?

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Siesta i Whispa Integrated technology

Dameca MRI 508. State-of-the-art MRI technology

Multi-Gas Analyzer. Multi-Gas Analyzer bcgroupintl.com. Features - MGA MGA-3050 Multi-Gas Analyzer

Technical Data and Specifications

IMPACT. Uni-Vent. Eagle. Model 754 Portable Ventilator

AV-S Ventilator User Manual

SLE5000 Infant Ventilator with HFO

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

SERVO-s v8.0 Data sheet

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

SLE5000 Neonatal Ventilator with High Frequency Oscillation

Oxygen Dialflow Meter. Instructions for Use

AV-S Ventilator. Service Manual. Partnership for Life. Remote Display Module and Interface for use with A200SP Absorber

NEONATAL/INFANT VENTILATOR

300 Held Drive Northampton Pa

Pressure Automated Calibration Equipment

APUS Anesthesia Machines

Oxylog VE300 Emergency & Transport Ventilation

Breathing Circuits. Product training

Fabius MRI. From specialists for specialists. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Datasheet Flow-c Anesthesia Machine System version 4.5

Oxylog 3000 plus Emergency & Transport Ventilation

HAMILTON-MR1. Technical specifications HAMILTON-MR1

INTENSIVE CARE VENTILATORS

Apollo Safety Features

Milestones of Aeonmed Ventilators

ALLIED HEALTHCARE PRODUCTS, INC. Litholyme, GE Medisorb, Carbolime, and Amsorb Plus. Test Summary

Prima SP Anaesthetic Machine Range Service Manual

Columbus Instruments

Oxygen Dialflow Meter. Instructions for Use

AV-S Ventilator User Manual. This manual contains information for software upgrade v

How Ventilators Work. Chapter 3

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Mass Casualty Ventilator Models: MCV100 & MCV100-B

D The plus that gives you more DRÄGER FABIUS PLUS

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

HAMILTON-C1 neo. Technical specifications

D The plus that makes all the difference DRÄGER FABIUS PLUS

Pneumatic high-pressure controller Model CPC7000

SIGNET 615 ANAESTHESIA WORKSTATION USER MANUAL

Mass Casualty Ventilator

Transcription:

GE Healthcare Aespire 7100 Essential performance Compact design Features Enhanced monitor integration capabilities with our Datex-Ohmeda Anesthesia Monitor and Compact Anesthesia monitor Lightweight and compact for easy maneuverability Optional integrated auxiliary O 2 flowmeter and suction control Advanced Breathing System (ABS ) One step bag/vent switch turns the ventilator on/off Minimal number of parts and tube connections greatly reduces the potential for leaks and misconnects Ease of disassembly (no tools) Fully autoclavable and latex-free 7100 Ventilator Volume and Pressure modes with electronic PEEP Exhaled volume, airway pressure and inspired oxygen monitoring capabilities Direct access to ventilator parameter settings Smart alarms direct user to specific problems and affected parameters Pressure bar graph for visual reference on a breath-bybreath basis (optional pressure waveform available) Aespire 7100 shown with Datex-Ohmeda Cardiocap /5 monitor and Tec 7 Vaporizers Improved low flow/reduced life cycle costs Only one scheduled maintenance check per year Fresh gas flow compensation automatically (available with tidal volume compensation option) Minimum O 2 flow of 50 ml Dual air flow tubes standard for higher resolution of low flows

Physical Specifications Dimensions Height: 134.5 cm/52.9 in Width: 72 cm/28.3 in Depth: 73 cm/28.7 in Weight: Approximately 108 kg/238 lb Top shelf Weight limit: 34 kg/75 lb Width: 66 cm/26 in Depth: 40 cm/15.75 in Work surface Height: 81.7 cm/32.2 in Size: 2160 cm 2 /334 in 2 Drawers (internal dimensions) Height: Width: Depth: Absorber bag arm (optional) Arm length: Bag arm height (adjustable): Casters Diameter: Brakes: 17.5 cm/6.9 in 33 cm/13 in 26.5 cm/10.4 in 30.5 cm/12 in 87 cm/34.3 in 104 cm/40.9 in 12.5 cm/5 in Individual locking front casters DIN rail Side of machine: 34.5 cm/13.6 in

Ventilator Operating Specifications Positive End Expiratory Pressure (PEEP) Range: Integrated, electronically controlled OFF, 4 to 30 cm H 2 O (increments of 1 cm H 2 O) Ventilator monitored values Optional pressure waveform shown Modes of ventilation Volume Control mode With tidal volume compensation (optional) Pressure mode (optional) Ventilation parameters Tidal volume range: 45 to 1500 ml (Volume Control mode) Incremental settings: 45 to 100 ml (increments of 5 ml) 100 to 300 ml (increments of 10 ml) 300 to 1000 ml (increments of 25 ml) 1000 to 1500 ml (increments of 50 ml) Pressure (P Inspired ) range: 5 to 50 cm H 2 O (increments of 1 cm H 2 O) 5 to 1500 ml volume delivery Rate: 4 to 65 breaths per minute (increments of 1 breath per minute) Inspiratory/ expiratory ratio: 2:1 to 1:6 (increments of 0.5) Inspiratory pause adjust: 5% to 60% of inspiratory time (increments of 5%) Tidal volume: Minute volume: Breathing rate: Oxygen percentage: 5 to 1500 ml, 1 ml resolution 0 to 99.9 L/min, 0.1 L/min resolution 0 to 65 breaths per minute, 1 breath per minute resolution 5% to 110%, 1% resolution Airway pressure: -9 to 99 cm H 2 O, 1 cm H 2 O resolution Alarm settings Tidal volume (V TE ): Low: OFF, 5 to 1500 ml High: 20 to 1600 ml, OFF Minute volume (V E ): Low: OFF, 0.1 to 10 L/min High: 0.5 to 30 L/min, OFF Inspired oxygen (FiO 2 ): Low: 18 to 100% High: 21 to 100%, OFF Apnea alarm: Low airway pressure: Pressure (P limit ) range: Sustained airway pressure: Subatmospheric pressure: Alarm silence countdown timer: Mechanical ventilation ON: < 5 ml breath measured in 30 seconds Mechanical ventilation OFF: < 25 ml breath measured in 30 seconds Change of < 4 cm H 2 O above PEEP 12 to 99 cm H 2 O (increments of 1 cm H 2 O) 6 to 30 cm H 2 O + PEEP (adjusted based on ventilator settings) Paw < -10 cm H 2 O 120 to 0 seconds

use 16 18 14 12 10 8 7 6 5 4 3 2 1 Ventilator Accuracy Delivery/monitoring accuracy Volume delivery: > 200 ml = better than ±10% Set TV 75 to 200 ml = better than ±20 ml < 75 ml = better than ±15 ml Pressure (P Inspired ) delivery repeatability: ±2 cm H 2 O PEEP delivery repeatability: ±2 cm H 2 O Volume monitoring: > 200 ml = better than ±10% 75 to 200 ml = better than ±20 ml < 75 ml = better than ±15 ml Pressure monitoring: Better than ±2 cm H 2 O and ±5% of reading (whichever is greater) Ventilator Components Flow transducer Variable orifice flow sensor Dimensions: 22 mm OD and 15 mm ID Location: Inspiratory outlet and expiratory inlet (Optional autoclavable sensor available) Battery backup Backup power: Battery type: Communication port Serial interface: Anesthetic Agent Delivery Delivery Demonstrated battery time under typical operating conditions is 90 + minutes when fully charged. Battery time under extreme conditions is 30 minutes. Internal rechargeable sealed lead acid Isolated RS-232C compatible port Vaporizers: Tec 5, Tec 6 Plus, Tec 7 Number of positions: 2 Mounting: Tool-free installation Selectatec manifold interlocks and isolates vaporizers Lock before Warning Keep upright at all times. Do not autoclave. Not for use in prescence of flammable anaesthetic agents. Only to be used in conlunction with an O monitor. See manual for Operational Instructions. Factors affecting performance. Service and maintenance recommendations. Next service date Oxygen sensor Galvanic fuel cell Warning High vaporizer settings with low gas flows may lead to hypoxic mixtures within the breathing circuit. Ohmeda strongly recommends the use of oxygen monitoring. Refer to manual before use. Calibrated for use at flows of 0.2 to 10 L/min. and at ambient temperatures of 18C to 30C at 1013mb. Tec 6 Plus Ventilator pneumatics USE ONLY DESFLURANE OPERATIONAL Pressure range at inlet: 240 kpa to 700 kpa/ 35 psig to 100 psig Use only Desflurane NO OUTPUT LOW AGENT WARM UP ALARM BATTERY LOW Peak gas flow: Flow range: 70 L/min + fresh gas flow 2 to 70 L/min Tec 6 Plus vaporizer Tec 7 vaporizer Flow compensation range: 200 ml/min to 15 L/min Ventilator screen Display size: 120 mm x 92 mm Display density: 1/4 VGA standard

Electrical Specifications Current leakage 100/120 V: < 300µA Power Power input: Power cord: Inlet/outlet modules (120 V) System circuit breakers: Outlets (optional): Pneumatic Specifications Auxiliary common gas outlet Connector: Gas supply Pipeline input range: Pipeline connections: Cylinder input: Primary regulator diaphragm minimum burst pressure: Primary regulator nominal output: 100-120 Vac, 50/60 Hz Length: 5 m/16.4 ft Rating: 15A @ 120 Vac 15A 4 outlets on back, 3-2A, 1-3A individual breakers, optional isolation transformer ISO 22 mm OD and 15 mm ID 240 kpa to 600 kpa/ 35 psig to 88 psig DISS-male, DISS-female, DIN 13252, AS4059, S90-116 or NIST (ISO 5359). All fittings available for O 2, N 2 O, and Air, and contain pipeline filter and check valve. Pin indexed in accordance with CGA-V-1 or DIN (nut and gland); contains input filter and check valve Note: Maximum 3 cylinders; two inboard mounted, one outboard mounted. 2758 kpa/400 psig < 338 kpa/49 psig Pin indexed cylinder connections < 407 kpa/59 psig DIN cylinder connections O 2 controls Method: Supply failure alarm: O 2 flush: Flowmeters Proportionate decrease of N 2 O with reduction in O 2 pressure Range: 193 kpa to 221 kpa/ 28 psig to 32 psig Sounds at maximum volume every 10 seconds Range: 25 to 75 L/min O 2 ranges: 0.05 to 0.95 L/min and 1 to 15 L/min; Minimum O 2 flow: 50 ml/min ±25 ml N 2 O ranges: 0 to 0.95 L/min and 1 to 10 L/min Air range: 0 to 0.95 and 1 to 15 L/min Calibration: Percent of Accuracy full scale flow (% of flowrate) 100 ±2.5% 90 ±2.5% 80 ±2.6% 70 ±2.7% 60 ±2.9% 50 ±3.1% 40 ±3.4% 30 ±4.0% 20 ±5.0% 10 ±8.1% Calibration conditions:* 20 C/68 F, 101.3 kpa/760 mmhg * Different breathing circuit pressures, barometric pressures or temperatures change flowtube accuracy. Hypoxic guard system Range: Materials Mechanical Link-25 Provides a nominal minimum 25% concentration of oxygen in O 2 /N 2 O mixture All materials in contact with patient breathing gases are free of natural rubber latex.

Environmental Specifications System operation Temperature: 10 to 40 C/50 to 104 F Humidity: 15 to 95% relative humidity (non-condensing) per IEC 68-2-3 Altitude: -440 to 3565 m/ 500 to 800 mmhg System storage Temperature: -15 to 50 C/-5 to 122 F Humidity: 10 to 95% relative humidity (including condensing) per IEC 68-2-3 Altitude: -440 to 5860 m/ 375 to 800 mmhg Oxygen cell storage: -15 to 50 C/5 to 122 F 10 to 95% relative humidity 500 to 800 mmhg Electromagnetic compatibility Immunity: Complies with all requirements of EN 60601-1-2 Emissions: CISPR 11 group 1 class B Approvals: UL 2601-1, CSA C22.2 #601.1 EN/IEC 60601-1 CE 0197 Breathing Circuit Specifications Operational modes Breathing circuit is circle mode only Carbon dioxide absorbent canister Absorbent capacity: 800 g Integrated expiratory limb water reservoír Ports and connectors Exhalation: Inhalation: Bag port: Pressure gauge 22 mm OD ISO 15 mm ID taper 22 mm OD ISO 15 mm ID taper 22 mm OD Scale range: 0 to 10 kpa/-20 to 100 cm H 2 0 Bag-to-Ventilator switch Control: Bi-stable Controls ventilator and direction of breathing gas within the circuit Integrated Adjustable Pressure Limiting (APL) valve Range: Tactile knob indication at: 0.8 to 70 cm H 2 O 30 cm H 2 O and above Adjustment range of rotation: 0.8 to 30 cm H 2 O (0 to 230 ) 30 to 70 cm H 2 O (230 to 330 )

Materials All materials in contact with exhaled patient gases are autoclavable, except disposable flow sensors and O 2 cell. (Autoclavable flow sensors optional). All materials in contact with patient gas are free of natural rubber latex. Breathing circuit parameters Compliance: Bag mode: 1.82 ml/cm H 2 O Mechanical mode: Automatically compensates for compression losses within the absorber and bellows assembly Circuit volume: 2.7 L Vent Mode 1.2 L Bag Mode Expiratory resistance: P exp Bag Mode P exp Vent Mode Flow rate Pressure drop Pressure drop 10 L/min 0.78 cm H 2 O 0.77 cm H 2 O 30 L/min 1.59 cm H 2 O 1.71 cm H 2 O 60 L/min 3.48 cm H 2 O 3.88 cm H 2 O Note: With patient circuit and wye piece add +0.89 cm H 2 O Anesthetic gas scavenging Type Hospital system Machine connection required Active low flow: High vacuum 36 L/min DISS evac (300 mmhg) @ 12 in Hg Passive: Passive or externally 30 mm/0.5 in attached active system M ISO taper Active adjustable flow: > 30L/min

2005 General Electric Company All rights reserved. GE and GE Monogram are trademarks of General Electric Company. Aespire, Cardiocap, ABS, Tec, Mechanical Link-25 and Selectatec are trademarks of Datex-Ohmeda, Inc. Datex-Ohmeda, Inc., a General Electric company, going to market as GE Healthcare. For more than 100 years, healthcare providers worldwide have relied on GE Healthcare for medical technology, services, and productivity solutions. So no matter what challenges your healthcare system faces, you can always count on GE to help you deliver the highest quality healthcare. For details, please contact your GE representative today. GE Healthcare P.O. Box 7550 Madison, WI 53707-7550 USA www.gehealthcare.com AN3969-B 11/05