Shafer RV-Series Rotary Vane Valve Actuators

Similar documents
Product Data Sheet L-TRDD-D Rev. 1 November Shafer L-Series Linear Valve Actuators Thrust Ratings and Dimensional Data

PressureGuard. Self-Contained Hydraulic Emergency Shutdown Systems For Rotary or Non API 6A Linear Valves

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

A Complete Solution For HIPPS

VBL Volume Booster. Features. D103393X012 January 2013

Safety Guide DOC.SG.EF.EN Rev. 0 March EL-O-Matic F-Series Rack and Pinion Pneumatic Actuators

BETTIS RPE Series Rack and Pinion Pneumatic Actuators. Safety Guide DOC.SG.BRPE.EN Rev. 1 November 2015

VBL Volume Booster. Instruction Manual Part Number: D103317X012, Rev. 1 Release: August 2013

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

T208VR Series Tank Blanketing Vacuum Regulator

Shafer Gas-Hydraulic Tanks Replacing Hydraulic Fluid Procedure on an Existing Actuator

Fisher L2sj Low Emission Liquid Level Controller

Damcos PHP Portable hand pump unit 5 l. Product Data Sheet September 2014 SD E04

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type R622 Pressure Reducing Regulator

1805 Series Relief Valves

Pressure Independent Control Series

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

Type 1190 Low-Pressure Gas Blanketing Regulator

Fisher 2625 and 2625NS Volume Boosters

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Installation Instructions

64 Series Pressure Reducing Regulators

Fisher and Whisper Disk Diffusers

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Fisher 4660 High-Low Pressure Pilot

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Installation Instructions

1805 Series Relief Valves

Y692VB Series Vacuum Breaker

Float Operated Level Controllers

Fisher DVI Desuperheater Venturi Inline

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Installation Instructions

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

PRESSURE REGULATORS. Type A/140. Process Management TM

Model DE-1, VDE-1 and DE-2 Air Release Heads

PRESSURE REGULATORS. Type B/240. Process Management TM

Installation Operation Maintenance

Type ACE95jr Tank Blanketing Valve

Quick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor

Roxar 2 System Mechanical Retrieval Tool

Fisher 4660 High-Low Pressure Pilot

SpeciÞcations. Engine Dimensions Dimensions in millimeters. Inch equivalents shown in [].

Pressure Sensing Valve - Model 4023

Roxar 2 System Mechanical Retrieval Tool

Fisher 8532 High-Performance Butterfly Valve

Type EZH Relief or Backpressure Regulator

1305 Series Pressure Reducing Regulators

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

1301 Series High-Pressure Regulators

Types ACE95 and ACE95Sr Tank Blanketing Valves

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

VBS-9263 Series. Application. Features. Applicable Literature

Autocalibration Systems for In Situ Oxygen Analyzers

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Introduction INDEX. INTRODUCTION HSE

Types ACE95 and ACE95Sr Tank Blanketing Valves

VB-7263 Series. Application. Features. Applicable Literature

Type 4660 High-Low Pressure Pilot

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Quick Start Guide LIQ-QSG-499ACL-03, Rev I July Rosemount 499ACL-03. Monochloramine Sensor

Fisher DSA Steam-Atomized Desuperheater

Storage Systems and Accessories

Pressure Dump Valve Service Kit for Series 2300 Units

Installation Instructions

Types ACE95 and ACE95Sr Tank Blanketing Valves

Hydraulic Piston Accumulators

VB-7273 Series. Application. Features. Applicable Literature

PVQ 13 A2 R SE 1 S 20 C-11 D

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271

PTS1120TSJB PTS2120TSTSJB

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

Fisher 4194 Differential Pressure Indicating Controllers

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Types S100K and S102K Pressure Regulators

TYPE 2800E EXTERNALLY MOUNTED, GAS LUBRICATED, NON-CONTACTING, DOUBLE CARTRIDGE SEAL

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

Directional Controls

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Series 2G Diaphragm Actuators

SLAM-SHUT VALVES. Type BM5. Process Management TM

Design DSA Steam-Atomized Desuperheater

Air Eliminators and Combination Air Eliminators Strainers

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

4194 Series Differential Pressure Indicating Controllers

Installation Instructions

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Type FEQ Slam-Shut Valve

Continuous digester. ANDRITZ Continuous Pulp Cooking System Extraction Zone

Full Range Pressure Compensating Variable Flow Control

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

RGC-IR Remote Gas Calibrator for IR400

TAM Single SeT inflatable

Transcription:

Shafer RV-Series Rotary Vane Valve Actuators Product Data Sheet RV-ASDD-D-3-06-09 Rev. 1 November 2017 U.S. Customary Units Dimension: inches (in) Torque: Inch Pounds (in-lbs) Pressure: Pounds Per Square Inch (psi) Weight: Pounds (lbs) Volume: Cubic Inches (in 3 )

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09 Rev. 1 November 2017 Table of Contents Section 1: Actuator Specifications Sheet Actuator Specifications... 1 Section 2: Dimensional Data Seets Dimensional Data...8 I

4 5/8 6 3/4 Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 1 of 11, Rev. 1 Actuator Specifications Note: 1/4 NPTF PORTS 5 1/4 Bolt circle, rotor bore, keyway quantity and size of mounting holes for RV-Series actuators will be custom fitted to specific valve. All dimension data is subject to change. All dimensions shown in inches. 5 1/ 4 3 1/ 8 8 3/4 6 1/2 x 2 Rotary Vane Actuator Torque expression: 11.5 in. lbs./psi Maximum test pressure: 3000 psi Maximum acceptable valve stem: 2-5/8 in. diameter Maximum wrench square: 2 in. across flats Weight of actuator including hydraulic fluid: 39 lbs. Actual fluid displacement per 90 strokes equals 21 cu. in. Gas consumption per 90 stroke equals 6.3 standard cu. ft. @ 1000 psi Number of strokes of standard 4 cu. in. hand pump per 90 stroke equals 6 1/4 NPTF PORTS 5 1/4 8 3/4 6 1/2 x 3 1/2 Rotary Vane Actuator Torque expression: 20 in. lbs./psi Maximum test pressure: 3000 psi Maximum acceptable valve stem: 2-5/8 in. diameter Maximum wrench square: 2 in. across flats Weight of actuator including hydraulic fluid: 94 lbs. Actual fluid displacement per 90 strokes equals 36 cu. in. Gas consumption per 90 stroke equals 6.53 standard cu. ft. @ 1000 psi Number of strokes of standard 4 cu. in. hand pump per 90 stroke equals 9 5 1/4 1 1/4 NPTF PORTS 11 1/4 9 1/8 8 3/4 6 1/2 x 8 Rotary Vane Actuator Torque expression: 47.3 in. lbs./psi Maximum test pressure: 3000 psi Maximum acceptable valve stem: 2-5/8 in. diameter Maximum wrench square: 2 in. across flats Weight of actuator including hydraulic fluid: 140 lbs. Actual fluid displacement per 90 strokes equals 82 cu. in. Gas consumption per 90 stroke equals 8.37 standard cu. ft. @ 1000 psi Number of strokes of standard 4 cu. in. hand pump per 90 stroke equals 21

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 2 of 11, Rev. 1 November 2017 9 x 7 Rotary Vane Actuator Torque expression: 72 in. lbs./psi Maximum test pressure: 3000 psi Maximum acceptable valve stem: 3-3/4 in. diameter Maximum wrench square: 2-1/2 in. across flats Weight of actuator including hydraulic fluid: 230 lbs. Actual fluid displacement per 90 strokes equals 125 cu. in. Gas consumption per 90 stroke equals 12.5 standard cu. ft. @ 1000 psi Number of strokes of standard 4 cu. in. hand pump per 90 stroke equals 32 9 x 12 Rotary Vane Actuator Torque expression: 128.5 in. lbs./psi Maximum test pressure: 3000 psi Maximum acceptable valve stem: 3-3/4 in. diameter Maximum wrench square: 2-1/2 in. across flats Weight of actuator including hydraulic fluid: 347 lbs. Actual fluid displacement per 90 strokes equals 225 cu. in. Gas consumption per 90 stroke equals 22.5 standard cu. ft. @ 1000 psi Number of strokes of standard 4 cu. in. hand pump per 90 stroke equals 57 1/2 NPTF PORTS (shown plugged) 4 1/2 4 1/2 12 1/2 x 8 Rotary Vane Actuator Torque expression: 186.77 in. lbs./psi Maximum test pressure: 2880 psi 1 2 1/2 Maximum acceptable valve stem: 4-1/2 in. diameter 9 1/4 Maximum wrench square: 3-1/4 in. across flats 15 5/8 Weight of actuator including hydraulic fluid: 500 lbs. Actual fluid displacement per 90 strokes equals 327 cu. in. Gas consumption per 90 stroke equals 32.6 standard cu. ft. @ 1000 psi Number of strokes of standard 4 cu. in. hand pump per 90 stroke equals 82 2

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 3 of 11, Rev. 1 1/2 NPTF PORTS (sh own plugged) 4 1/2 4 1/2 12 1/2 x 12 Rotary Vane Actuator Torque expression: 288 in. lbs./psi Maximum test pressure: 2880 psi 1 6 1/2 Maximum acceptable valve stem: 4-1/2 in. diameter 9 1/4 15 5/8 Maximum wrench square: 3-1/4 in. across flats Weight of actuator including hydraulic fluid: 660 lbs. Actual fluid displacement per 90 strokes equals 490 cu. in. Gas consumption per 90 stroke equals 48.9 standard cu. ft. @ 1000 psi Number of strokes of standard 4 cu. in. hand pump per 90 stroke equals 123 1/2 NPTF PORTS (shown plugged) 5 3/4 5 3/4 14 1/2 x 16 Rotary Vane Actuator Torque expression: 522 in. lbs./psi Maximum test pressure: 2440 psi 2 0 9/16 Maximum acceptable valve stem: 5-1/2 in. diameter Weight of actuator including hydraulic fluid: 1064 lbs. 10 3/8 18 1/4 Actual fluid displacement per 90 strokes equals 913 cu. in. Gas consumption per 90 stroke equals 91.2 standard cu. ft. @ 1000 psi Number of strokes of standard 12 cu. in. hand pump per 90 stroke equals 76 16 1/2 x 16 Rotary Vane Actuator Torque expression: 688.5 in. lbs./psi Maximum test pressure: 2160 psi Maximum acceptable valve stem: 6 in. diameter 11 1/2 Weight of actuator including hydraulic fluid: 1325 lbs. Actual fluid displacement per 90 strokes equals 1280 cu. in. Gas consumption per 90 stroke equals 127.8 standard cu. ft. @ 1000 psi Number of strokes of standard 12 cu. in. hand pump per 90 stroke equals 107 3

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 4 of 11, Rev. 1 November 2017 13 3/4 20 x 16 Rotary Vane Actuator Torque expression: 1,148.4 in. lbs./psi Maximum test pressure: 2250 psi Maximum acceptable valve stem: 6 in. diameter Weight of actuator including hydraulic fluid: 1880 lbs. Actual fluid displacement per 90 strokes equals 2013 cu. in. Gas consumption per 90 stroke equals 201 standard cu. ft. @ 1000 psi Number of strokes of standard 12 cu. in. hand pump per 90 stroke equals 168 25 x 16 Rotary Vane Actuator Torque expression: 1853.1 in. lbs./psi Maximum test pressure: 2160 psi 16 3/4 Maximum acceptable valve stem: 6-1/2 in. diameter Weight of actuator including hydraulic fluid: 2920 lbs. Actual fluid displacement per 90 strokes equals 3232 cu. in. Gas consumption per 90 stroke equals 322.8 standard cu. ft. @ 1000 psi Number of strokes of standard 12 cu. in. hand pump per 90 stroke equals 270 3/4 NPTF PORTS (shown plugged) 8 8 26 x 22 Rotary Vane Actuator Torque expression: 2691.5 in. lbs./psi Maximum test pressure: 2160 psi 17 1/2 30 1/16 Maximum acceptable valve stem: 7-3/8 in. diameter Weight of actuator including hydraulic fluid: 4050 lbs. 31 Actual fluid displacement per 90 strokes equals 4697 cu. in. Gas consumption per 90 stroke equals 469.1 standard cu. ft. @ 1000 psi Number of strokes of standard 12 cu. in. hand pump per 90 stroke equals 392 4

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 5 of 11, Rev. 1 17 1/2 3/4 NPTF PORTS (shown plugged) 44 1/16 8 8 31 26 x 36 Rotary Vane Actuator Torque expression: 4,338 in. lbs./psi Maximum working pressure: 1000 psi Maximum test pressure: 2000 psi Maximum acceptable valve stem: 7-3/8 in. diameter Weight of actuator including hydraulic fluid: 7687 lbs. Actual fluid displacement per 90 strokes equals 7686 cu. in. Gas consumption per 90 stroke equals 767.6 standard cu. ft. @ 1000 psi Number of strokes of standard 12 cu. in. hand pump per 90 stroke equals 641 21 1/2 1 1/4 NPTF PORTS (shown plugged) 10 10 40 1/16 39 33 x 32 Rotary Vane Actuator Torque expression: 5,868 in. lbs./psi Maximum working pressure: 1000 psi Maximum test pressure: 1500 psi Maximum acceptable valve stem: 9-1/2 in. diameter Weight of actuator including hydraulic fluid: 8900 lbs. Actual fluid displacement per 90 strokes equals 10857 cu. in. Gas consumption per 90 stroke equals 1084.2 standard cu. ft. @ 1000 psi Number of strokes of standard 12 cu. in. hand pump per 90 stroke equals 905 5

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 6 of 11, Rev. 1 November 2017 Speed of Operation in Seconds Per 90 Rotation* Actuator Operating Pressure (psig) Size 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 6 1/2 x 2 8 5 4 4 3 3 3 2 2 2 2 2 1 1 6 1/2 x 3 1/2 9 6 5 5 4 3 3 3 2 2 2 2 1 1 6 1/2 x 8 10 7 6 6 5 4 4 4 3 1/2 3 1/2 3 3 2 1 9 x 7 14 11 9 8 8 7 5 5 5 5 3 3 2 2 9 x 12 15 13 11 10 9 9 8 7 6 6 5 4 4 3 12 1/2 x 8 15 14 12 11 11 10 9 9 8 8 7 6 6 6 12 1/2 x 12 20 18 18 16 15 13 10 10 10 10 9 9 9 9 14 1/2 x 16 32 25 20 18 16 14 14 12 12 12 12 11 11 11 16 1/2 x 16 40 30 28 23 20 19 17 16 15 15 15 15 15 14 20 x 16 40 35 30 25 24 22 20 20 20 19 19 19 19 18 25 x 16 76 53 43 37 33 30 25 25 24 24 24 24 22 22 26 x 22 80 60 50 40 35 30 25 25 25 25 25 25 25 25 26 x 36 90 80 70 50 45 40 38 35 35 35 33 x 32 254 178 146 125 111 102 95 88 83 79 * Stroking speeds above are approximate as speed may be affected by fluid viscosity or the flow capacities of the individual control components. The listed speeds are based on actuators with gas hydraulic tanks, hand pump and the standard poppet type control block in the power supply circuit. Adjustable speed control valves may be specified so that the stroking speed may be finetuned to the field operating conditions. If faster speeds are required, please consult a factory representative. Approximate Weights For Shafer Rotary Operators, Hydraulic Tanks And Power Storage Tanks Size Operator Weight (lbs) Hydraulic Tank Weight (lbs) (per Pair) Power Storage Tank (Standard) Weight (lbs) 6 1/2 x 2 39 35 20 6 1/2 x 3 1/2 100 35 20 6 1/2 x 8 150 75 40 9 x 7 275 111 52 9 x 12 400 170 85 12 1/2 x 8 500 265 125 12 1/2 x 12 660 406 175 14 1/2 x 16 1064 675 275 16 1/2 x 16 1325 875 450 20 x 16 1880 1275 693 25 x 16 2920 2708 1181 26 x 22 4500 3348 1450 26 x 36 7687 5362 2315 33 x 32 8900 7448 3160 6

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 7 of 11, Rev. 1 Approximate Weights For Shafer Hand Pumps, 2-Way Electric Controls and Limit Switches Pumps Control (Two-Way Electric) Limit Switch 4 cu. in. = 20 lbs. 1/4 in. = 60 lbs. LARGE = 25 lbs. 12 cu. in. = 44 lbs. 1/2 in. = 75 lbs. -------- 4 cu. in. Pump, 1/4 Poppet Block = 52 lbs. + Cover 28 lbs. = Total 80 lbs. 12 cu. in. Pump, 1/4 Poppet Block= 102 lbs. + Cover 42 lbs. = Total 144 lbs. Linebreak Small Plate with Lockout = 42 lbs. + Cover 22 lbs. = 64 lbs. 4 cu. in. Pump / D.H.V. = 50 lbs. 12 cu. in. Pump / D.H.V. = 110 lbs. Limit Valve (ESD) with Plate 10 lbs. 1-08672 Terminal Box= 10 lbs. 1-09027 Terminal Box = 12 lbs. 1/4 Poppet Block, 4 cu. in. Pump & Linebreak with cover = 95 lbs. 7

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 8 of 11, Rev. 1 November 2017 Dimensional Data Gas / Hydraulic Rotary Vane - Horizontal Stem, Vertical Line Note: All dimensional data is for reference only and subject to change. Depending on the application, specific actuator controls may or may not be located inside of the control box. Where specified, there may be additional pressure vessels or power storage tanks which are not shown. Size A B C D E F G H J K L M 6 1/2 x 2 5 1/4 24 1/2 29 231/4 25 1/4 18 1/4 19 1/4 16 1/4 8 3/4 9 1/4 1/2 2 1/4 6 1/2 x 3 1/2 6 3/4 24 1/2 29 23 1/4 25 1/4 18 1/4 19 1/4 16 1/4 8 3/4 9 1/4 1/2 3 3/4 6 1/2 x 8 11 1/4 24 1/2 29 30 25 1/4 18 1/4 19 1/4 16 1/4 8 3/4 9 1/4 4 3/4 6 1/2 9 x 7 10 3/4 29 3/4 35 1/2 30 3/4 25 1/4 21 1/4 19 1/4 21 1/4 11 3/4 10 3/4 4 1/4 5 1/2 9 x 12 16 1/4 30 1/2 36 1/4 37 1/2 25 1/4 23 1/4 19 1/4 22 11 3/4 113/4 7 1/2 11 12 1/2 x 8 12 1/2 32 1/2 39 1/4 45 1/4 25 1/4 23 1/4 19 1/4 24 15 3/4 11 3/4 11 1/2 7 1/2 12 1/2 x 12 17 33 3/4 41 1/2 42 25 1/4 27 1/4 19 1/4 25 1/4 15 3/4 12 1/4 10 10 3/4 14 1/2 x 16 20 9/16 44 1/2 53 1/2 47 32 1/2 33 1/2 23 32 18 1/4 16 1/2 7 9 1/4 16 1/2 x 16 22 1/2 45 3/4 55 3/4 60 1/4 32 1/2 33 1/2 23 33 1/2 19 3/4 16 1/2 13 1/4 10 3/4 20 x 16 23 1/4 49 1/2 61 1/2 58 32 1/2 40 23 37 24 1/4 17 1/2 12 1/4 10 1/2 25 x 16 24 3/4 51 1/4 66 1/4 67 3/4 36 1/4 44 25 1/4 37 1/2 30 11 1/2 17 1/4 10 1/4 26 x 22 32 1/4 * * * 36 1/4 * 25 1/4 * 31 * * * 26 x 36 45 1/2 * * * 36 1/4 * 25 1/4 * 31 * * * 33 x 32 41 1/4 * * * 36 1/4 * 25 1/4 * 39 * * * * Indicates this particular size of actuator has not been used in this type of application. All dimensions shown in inches. H F/2 G /2 M A F G ACTUATO R A P P R O X I M A T E O V E R A L L C ON TR OL GAS/H YDRAU LIC TA N K ASSEM BLY D E J- D IAMET ER C L O SE L O P E N K B C APPR O XIM ATE OVER ALL 8

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 9 of 11, Rev. 1 Gas / Hydraulic Rotary Vane - Vertical Stem, Horizontal Line Note: All dimensional data is for reference only and subject to change. Depending on the application, specific actuator controls may or may not be located inside of the control box. Where specified, there may be additional pressure vessels or power storage tanks which are not shown. Size A B C D E F G H J K M 6 1/2 x 2 5 1/4 24 1/4 28 1/2 23 1/4 25 1/4 18 1/4 19 1/4 15 3/4 8 3/4 1/2 5 1/4 6 1/2 x 3 1/2 6 3/4 24 1/4 28 1/2 23 1/4 25 1/4 18 1/4 19 1/4 15 3/4 8 3/4 1/2 5 6 1/2 x 8 11 1/4 24 1/4 28 1/2 30 25 1/4 18 1/4 19 1/4 15 3/4 8 3/4 4 3/4 3 1/4 9 x 7 10 3/4 27 1/2 33 1/2 30 3/4 25 1/4 21 1/4 19 1/4 19 1/4 11 3/4 4 1/4 5 9 x 12 16 1/4 28 1/2 34 1/4 37 1/2 25 1/4 23 1/4 19 1/4 20 11 3/4 7 1/2 3 1/2 12 1/2 x 8 12 1/2 32 39 3/4 45 1/4 25 1/4 23 1/4 19 1/4 23 1/2 15 3/4 9 2 1/2 12 1/2 x 12 17 32 39 3/4 42 25 1/4 27 1/4 19 1/4 23 1/2 15 3/4 10 3/4 14 1/2 x 16 20 9/16 38 3/4 47 3/4 47 32 1/2 33 1/2 23 26 1/4 18 1/4 7 5 1/4 16 1/2 x 16 22 1/2 40 50 60 1/4 32 1/2 33 1/2 23 27 3/4 19 3/4 13 1/4 1 1/4 20 x 16 23 1/4 44 1/4 56 1/4 58 32 1/2 40 23 31 3/4 24 1/4 12 1/4 6 1/2 25 x 16 24 1/2 51 66 67 3/4 36 1/2 44 25 1/4 36 1/2 30 13 1/2 9 1/4 26 x 22 32 37 68 84 1/4 36 1/2 48 25 1/4 38 31 21 3/4 6 3/4 26 x 36 45 1/4 58 73 1/2 69 1/2 36 1/2 57 25 1/4 43 1/2 31 13 1/4 8 1/2 33 x 32 41 1/4 62 1/4 81 3/4 97 1/2 36 3/4 57 25 1/4 47 3/4 39 28 1/4 10 3/4 * Indicates this particular size of actuator has not been used in this type of application. All dimensions shown in inches. H A P P R O X IM A T E F O VE R AL L F/2 G/2 CLOSE J - DIAMETER G OP E N CONTR OL GAS/HYDRA ULIC TANK ASSEMBL Y A P P R O X IM A T E O VE R AL L E D ACTU AT OR A K M B C APPR OXIMATE OVERALL 9

Product Data Sheet Shafer RV-Series RV-ASDD-D-3-06-09, Page 10 of 11, Rev. 1 November 2017 Central Hydraulic System - Horizontal Stem, Vertical Line Note: All dimensional data is for reference only and subject to change. Depending on the application, specific actuator controls may or may not be located inside of the control box. Where specified, there may be additional pressure vessels or power storage tanks which are not shown. Size A B C D E F G H J K L M 6 1/2 x 2 5 1/4 23 1/2 27 30 3/4 22 3/4 22 19 1/4 17 8 3/4 12 1/2 4 1/2 2 1/4 6 1/2 x 3 1/2 6 3/4 24 3/4 29 30 3/4 22 3/4 22 19 1/4 17 8 3/4 12 1/2 4 1/2 3 3/4 6 1/2 x 8 11 1/4 24 3/4 29 30 3/4 22 3/4 22 19 1/4 17 8 3/4 12 1/2 4 1/2 6 1/2 9 x 7 10 3/4 26 1/4 32 31 1/2 22 3/4 22 19 1/4 18 1/2 11 3/4 12 1/2 5 5 1/4 9 x 12 16 1/4 26 1/4 32 31 1/2 22 3/4 22 1/2 19 1/4 18 1/2 11 3/4 12 1/2 5 10 3/4 12 1/2 x 8 12 1/2 28 36 32 1/2 22 3/4 23 1/4 19 1/4 20 1/2 15 3/4 12 1/2 5 8 3/4 12 1/2 x 12 17 28 36 33 1/2 22 3/4 23 1/4 19 1/4 20 1/2 15 3/4 12 1/2 5 10 3/4 14 1/2 x 16 20 9/16 34 1/4 43 1/4 34 3/4 32 1/2 26 1/2 28 1/4 23 1/4 18 1/4 12 1/2 9 9 1/4 16 1/2 x 16 22 1/2 35 45 35 1/2 32 1/2 26 1/2 28 1/4 24 19 3/4 12 1/2 9 10 3/4 20 x 16 23 1/4 37 1/2 49 3/4 37 3/4 32 1/2 26 1/2 28 1/4 26 1/2 24 1/4 12 1/2 9 10 1/2 25 x 16 24 1/2 36 3/4 51 3/4 46 36 1/2 25 25 1/4 28 3/4 30 12 1/2 5 1/2 12 1/4 26 x 22 32 * * * 36 1/2 * 25 1/4 * 31 * * * 26 x 36 45 1/4 * * * 36 1/2 * 25 1/4 * 31 * * * 33 x 32 41 1/4 * * * 36 1/2 * 25 1/4 * 39 * * * * Indicates this particular size of actuator has not been used in this type of application. All dimensions shown in inches. A P P R O X I M A T E F O V E R A L L G M A K G /2 ACTUATO R C ON TR OL R ESER VOIR TA N K A P P R O X I M A T E O V E R A L L E J - D IAMET ER L B H C U STOM ER CONNECTIO N C APPR O XIM ATE OVER ALL 10

Shafer RV-Series Product Data Sheet November 2017 RV-ASDD-D-3-06-09, Page 11 of 11, Rev. 1 Central Hydraulic System - Vertical Stem, Horizontal Line Note: All dimensional data is for reference only and subject to change. Depending on the application, specific actuator controls may or may not be located inside of the control box. Where specified, there may be additional pressure vessels or power storage tanks which are not shown. Size A B C D E F G H J K L 6 1/2 x 2 5 1/4 24 3/4 29 31 1/4 22 3/4 22 19 1/4 17 8 3/4 12 1/2 1/2 6 1/2 x 3 1/2 6 3/4 24 3/4 29 31 3/4 22 3/4 22 19 1/4 17 8 3/4 12 1/2 1 6 1/2 x 8 11 1/4 24 3/4 29 34 1/2 22 3/4 22 19 1/4 17 8 3/4 12 1/2 3 3/4 9 x 7 10 3/4 26 32 33 22 3/4 22 19 1/4 18 1/2 11 3/4 12 1/2 2 1/2 9 x 12 16 1/4 26 32 38 1/2 22 3/4 22 19 1/4 18 1/2 11 3/4 12 1/2 8 12 1/2 x 8 12 1/2 27 1/4 34 34 1/2 22 3/4 22 19 1/4 19 1/2 15 3/4 12 1/2 1 1/2 12 1/2 x 12 17 28 1/4 36 38 1/2 22 3/4 22 19 1/4 20 3/4 15 3/4 12 1/2 7 3/4 14 1/2 x 16 20 9/16 34 1/4 43 1/4 40 1/2 32 1/2 26 1/2 28 1/4 23 1/4 18 1/4 12 1/2 4 16 1/2 x 16 22 1/2 35 45 41 32 1/2 26 1/2 28 1/4 24 19 3/4 12 1/2 6 1/2 20 x 16 23 1/4 37 1/2 49 3/4 40 3/4 32 1/2 26 1/2 28 1/4 26 1/2 24 1/4 12 1/2 6 25 x 16 24 1/2 36 3/4 51 3/4 50 3/4 36 1/2 25 25 1/4 28 1/2 30 12 1/2 14 1/4 26 x 22 32 37 1/4 52 3/4 53 1/4 36 1/2 25 25 1/4 28 3/4 31 12 1/2 16 3/4 26 x 36 45 1/4 * * * 36 1/2 * 25 1/4 * 31 * * 33 x 32 41 1/4 * * * 36 1/2 * 25 1/4 * 39 * * * Indicates this particular size of actuator has not been used in this type of application. All dimensions shown in inches. A P P R O X I M A T E O V E R A L L G F K G /2 J - D IAMET ER CONTR OL R ESER VOIR TA N K A P P R O X I M A T E O V E R A L L D E ACTUATO R A L B H C U STOM ER CONNECTIO N C APPR O XIM ATE OVER ALL 11

World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers. Choose the WACC or sales office nearest you: NORTH & SOUTH AMERICA 19200 Northwest Freeway Houston TX 77065 USA T +1 281 477 4100 F +1 281 477 2809 2500 Park Avenue West Mansfield Ohio 44906 USA T +419 529 4311 F +419 529 3688 MIDDLE EAST & AFRICA P. O. Box 17033 Dubai United Arab Emirates T +971 4 811 8100 F +971 4 886 5465 P. O. Box 10305 Jubail 31961 Saudi Arabia T +966 3 340 8650 F +966 3 340 8790 Av. Hollingsworth 325 Iporanga Sorocaba SP 18087-105 Brazil T +55 15 3238 3788 F +55 15 3228 3300 ASIA PACIFIC No. 9 Gul Road #01-02 Singapore 629361 T +65 6777 8211 F +65 6268 0028 No. 1 Lai Yuan Road Wuqing Development Area Tianjin 301700 P. R. China T +86 22 8212 3300 F +86 22 8212 3308 24 Angus Crescent Longmeadow Business Estate East P.O. Box 6908 Greenstone 1616 Modderfontein Extension 5 South Africa T +27 11 451 3700 F +27 11 451 3800 EUROPE Berenyi u. 72-100 Videoton Industry Park Building #230 Székesfehérvár 8000 Hungary T +36 22 53 0950 F +36 22 54 3700 For complete list of sales and manufacturing sites, please visit www.emerson.com/actuationtechnologieslocations or contact us at info.actuationtechnologies@emerson.com www.emerson.com/shafer 2017 Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Shafer TM is a mark of one of the Emerson family of companies. All other marks are property of their respective owners. The contents of this publication are presented for information purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.