Rates of various Line materials and Labour charges used in cost sheets for general works

Similar documents
Method statement for. The installation of. Precast Concrete Piles. (Site Name).

The Sports Betting Champ s Never Lost NFL Super Bowl Betting System

GAS CYLINDERS RULES, 2004

MATH TIMESAVERS By: STEVAN KRAJNJAN THIS BOOK BELONGS TO:

Rules & Regulations on Membership Approved (January 28, 2017) a. Regular Members shall meet all requirements in the ASA By-Laws and the following;

Sample Sailing Instructions for Sanctitoned Lightning Class Championship Regattas

Copper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods

Information. Additional Requested Information: Attachments: MAHARASHTRA STATE ELECTRICITY TRANSMISSION CO. LTD. Tender for Operations and maintenance

DEFINITION OF PENALTIES

Analysis!of!Rainforest!Alliance!Report!on!the!Verification!of!Progress!Related!to!Enabling!Activities! for!the!guyana"norway!redd+!agreement!!!

Journeyman Team Events

DEFINITION OF PENALTIES

TOUR PROGRAMME OF CERAP

i) Filtration machine, measuring equipment and other related machinery

CASH PRIZE SCHEME PREAMBLE

Whiskey City Lineman Rodeo Competitive Events

F OVERHEAD CONSTRUCTION & STRINGING EQUIPMENT GRIP SELECTION

Installation and Training Manual

Conductors. By far the largest and most important component of any earthing or structural lightning protection system is the actual conductor.

LIST OF ILLUSTRATIONS

F OVERHEAD CONSTRUCTION & STRINGING EQUIPMENT WIRE GRIPS HI-TOOL NGK WIRE GRIPS (MADE IN JAPAN)

THE LIFE OF THOMAS HARDY

PORTABLE LIGHTNING MAST PROTECTION PLP SERIES INSTRUCTION MANUAL

F OVERHEAD CONSTRUCTION & STRINGING EQUIPMENT WIRE GRIPS HI-TOOL NGK WIRE GRIPS (MADE IN JAPAN)

Title: NFPA 70E Effective Date: 12/8/2014 Control Number: THG_0053 Revision Number: 1 Date: 10/26/2015 Annual Review Completed: 5/13/2015 NFPA 70E

KRAV MAGA LEVEL 1 CURRICULUM

KRAV MAGA LEVEL 1 CURRICULUM

SIROCCO. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming.

THE GENERAL ASSEMBLY OF PENNSYLVANIA HOUSE BILL

MANUFACTURING TECHNICAL INSTRUCTIONS - SAFETY FALL HAZARD CONTROL REQUIREMENTS SERIES & NO. SMI - 157

Ministry of Finance Bulletin

TRADE SHOW AND CONVENTION INSTALLER AGREEMENT

City of Roseville - Adult Softball League Rules

Databank. India Census 1881

LCW3-YFFL OFFICIAL RULES

INSTRUCTIONS 360 Y-DROP HAGIE STS 2015

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

COMPUTATIONAL OCEAN ACOUSTIC TOOLBOX MANUAL. Computational Ocean Acoustics Toolbox (COAT) is a package written containing the following

Tripod Setup Guide (M-TPx)

Oldrich Jindra coaching clinics. Drillbook Full ice 1-0

Page 1 of 1 04/19/13 SBR

Channel Bracket Support Cable Bracket Bearer Locking Pin Foundation Bolt Iron Anchor Step Manhole Sump Grill PVC/Steel Ladder Ladder Support & Hook

City of Roseville - Adult Softball League Rules

S Surge Arresters

LAST PG: * WE RESERVE THE RIGHT * ZERO TOLERANCE POLICY

Rebreather Training Council Standard

Co-ed Flag Football Rules

ABB NASOM Fun Run 2017

Chapter Two: Travel Agents, Tour Operators, Contracts and Legal Rights What You Need to Know... 9

Your grade may then be calculated by the following formula (Daily Points + Test Scores) / (# of days * 4 + # of tests * 100)

Certified in 3 & 4 leg configurations to CEN/TS 16415:2013 for maximum 2 persons and EN 795:2012 for single person use. total edge management system

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X

Price List January SECUROPE Life Line

AutoChanger Installation & User Guide Issue 2

PAGE INDEX PAGE # CATALOG NUMBER BUS SUPPORTS B 1 AWSTFR BUS SUPPORTS B 2 AWTTFR BUS SUPPORTS B 3 AWTESR BUS SUPPORTS B 4 AWLI BUS SUPPORTS B 6 AACB

[TO BE PUBLISHED IN THE GAZETTE OF INDIA, EXTRAORDINARY, PART II, GOVERNMENT OF INDIA MINISTRY OF FINANCE (DEPARTMENT OF REVENUE)

Photo Coming. Utility Anchors. macleanpower.com

Mini Channel & Fittings

Operating instructions. Surge arrester Type MVR

Table of Contents. Foreword... xix. Preface...xxii. Section I Usage of Online Surveys and Measurements

Title: Fall Protection Effective Date: 5/20/2006 Control Number: THG_0003 Revision Number: 1 Date: 10/10/2015 Annual Review Completed: 5/13/2015

Contents ... TEACHER GUIDE NCTM Content Standards Assessment Rubric... 6 How Is Our Resource Organized? The NCTM Principles & Standards...

INTERNATIONAL CASTING SPORT FEDERATION. International Tournament Rules for Casting sport. Print 2016

Low Wind High Yields Series

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

CHAIN LINK FENCE GATE

India Mark Handpump. Available Models & OperatingData: Materials of Construction: HANDPUMP. Recommended for water level setting depth (meters)

THE NATURAL RESOURCES BODY FOR WALES WATER RESOURCES ACT 1991 THE WALES ROD AND LINE (SALMON AND SEA TROUT) BYELAWS 2017

MILLER, Kelly. Digital Howard University. Howard University. MSRC Staff

Lightning and surge protection for yachts

Intermediate Angle, 0-25, Drilling detail. Angle 26-50, Baulk Plates, Pole Details. Termination Poles, ABC Details

2.4M Viking Swing Basket Swing

Precision Liquid Settlement Array Manual

TOWER INSTALLATION MANUAL For A.R.E. Guyed Pipe Towers Short Towers 43, 64 and 85 feet tall

TRAVSMART permanent single-cable horizontal lifeline system

Type 73 Mast System TELESCOPIC & SECTIONAL MAST SYSTEMS

OFFICIAL RULES AND REGULATIONS 2017

I.H.S INSTALLATION INSTRUCTIONS

TVPPA Lineman Apprenticeship Program

IS37 10 Metre Instrument Mast Handbook

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

THE MEMOIRS. JACQUES CASANOVA de SEINGALT

Deluxe Gourd Racks I D E G A. Parts List. Shown above are parts for the two-level, Deluxe Gourd Rack (DGR 12V)with 12 arms for vertically hung gourds.

Saab Seaeye Cougar XT Compact

TSX1600L Rite-Lock Power Arm Kit, left Stowing W/One Top Mount Pivot W/20" Base & 27" Upper

NRHSAA GIRLS GYMNASTICS

An Update on IEC TC 81 (Lightning Protection)

Parts Manual. Scraper Hitches PH:

First South East European Regional CIGRÉ Conference, Portoroz Deep Water Power Cable Systems? Indeed!

S Surge Arresters. Handling and Storage. Standards. Acceptance and Initial Inspection

Davorin Matanović DRILLING LINE (ROPE) AND BLOCKS

TENSOREX C+ TENSOREX C+

Initial Review of Research Policy and Procedure

ELECTRIC OPERATING PROCEDURES Date: 11/01/06

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

Security and confidence at height.

HEAVY DUTY H.S. DISCUS CAGE NET POLE NET POLE INSTALLATION

INTERNATIONAL CASTING SPORT FEDERATION. Internationale Castingsport Wettkampfbestimmungen. ICW Ausgabe: 2012

S.R.A. Fully Engineered Product Range

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Transcription:

Rates of various Line materials and Labour charges used in cost sheets for general works SL.NO Particulars Unit Materials rate in Rs. Labour charges (Casual) in Rs 1 2 3 4 5 RCC Poles a) 9.5 M 350kg WL Nos. 7675 1373 I b) 9M 145kg WL Nos. 5941 1060 c) 9M 150kg WL Square section Nos. 7210 1060 d) 8M 115kg WL Nos. 4351 848 II PCC Poles 8M PCC Poles 140kg WL Nos. 2495 848 PSC Poles III a) 11M 365kg WL Nos. 7924 1552 b) 9M 200kg WL Nos. 3401 1060 d) 8M 200kg WL Nos. 2942 848 IV Pre-Stressed Tubular Spun Pole 11M Long Nos. 15800 2353 PSCC Poles 9M PSCC pole WL 300Kg Nos. 4578 1060 9M PSCC pole 160Kg WL in Transverse direction and 136Kg WL in Longitudinal Nos. 3558 1060 directional Guy Less Pole Nos. New Item Double Pole Structure complete including 5 KG, 8SWG G.I. Wire for V Structure Grounding a) 9M RCC Poles Set 15910 3252 b) 8M RCC Poles Set 12730 3104 c) 9M PSCC Poles with 300Kg WL Set 13184 3252 Three Pole structure complete including 5 KG, 8SWG G.I. Wire for VII Structure Grounding a) 9M RCC Poles Set 27446 6271 b) 8M RCC Poles Set 22676 6049 c) 9M PSCC Poles with 300Kg WL Set 23357 6271 Transformer Structure complete VII with cross arms braces, clamps, 1) bolt&nuts and washers, For 25/63 kva a) Using 2nos 9M RCC Poles Set 19271 4115 b) Using 2 nos 8M RCC Poles Set 16091 3560 c) 9M PSCC Poles with 300Kg WL Set 16545 4115 For 25/63 kva- Star Rated Transformers

1) 2) 3) 4) VIII a) Using 2nos 9M RCC Poles Set 22532 4115 b) Using 2 nos 8M RCC Poles Set 19352 3560 c) 9M PSCC Poles with 300Kg WL Set 19806 4115 For 100 / 250 kva a) Using 2nos 9M RCC Poles Set 24575 4238 b) Using 2 nos 8M RCC Poles Set 21395 3816 c) 9M PSCC Poles with 300Kg WL Set 21849 4238 Note: The items V, VI, includes the cost of poles, structure materials & 5 kgs of G.I wire required for earthing of structure materials. Fixing Single pole mounted transformer kit on 9 mtr RCC pole (square sec) / 9 Mtr PSCC pole 300KG WL (Excluding Errection of pole) for 25/63kVA Transformer Set 4088 1016 for 100kVA Transformer Set 6129 1016 For Single pole mounted transformer kit for 100/250kVA on 11 mtr spun pole (Excluding Set 23035 2033 Errection of pole) 11 kv Horizontal cross arm with H.T.Single top support, clamp,bolts, nuts and washers MS a) For RCC Poles Set 382 99 b) For PSC Poles Set 377 99 b) For PCC Poles Set 374 99 11 kv Horizontal cross arm with H.T.Single top support, clamp,bolts, nuts and washers GI IX a) For RCC Poles Set 505 99 b) For PSC Poles Set 498 99 b) For PCC Poles Set 493 99 11 kv Horizontal cross arm, clamp,bolts, nuts and washers for DC Lines MS a) For RCC Poles each 316 81 b) For PSC Poles each 311 81 b) For PCC Poles each 308 81 11 kv Horizontal cross arm, clamp,bolts, nuts and washers for DC Lines GI a) For RCC Poles each 422 81 b) For PSC Poles each 415 81 b) For PCC Poles each 411 81

X XI XII XIII XIV 4-Pin cross arm with pole clamp, braces MS a) RCC Poles Set 263 96 b) For PSC Poles Set 258 96 b) PCC Poles Set 255 96 4-Pin cross arm with pole clamp, braces GI a) RCC Poles Set 352 96 b) For PSC Poles Set 345 96 b) PCC Poles Set 340 96 2-Pin cross arm with pole clamp, braces MS a) RCC Poles Set 162 96 b) For PSC Poles Set 157 96 b) PCC Poles Set 154 96 2-Pin cross arm with pole clamp, braces GI a) RCC Poles Set 219 96 b) For PSC Poles Set 212 96 b) PCC Poles Set 207 96 LT Cross arm for vertical configuration with Set 626 287 clamps,bolts,nuts and washers HT Single Top support with bolt,nuts and washers Set 89 64 LT Single Top support with bolt,nuts and washers Set 69 64 Insulators a) 11kV Ceramic Pin insulator with GI pin No 94 b) No.15 Strain Insulator No 33 c) No.8 Strain Insulator No 14 d) 1.1 KV Ceramic Pin Insulator With GI pin No 38 11 KV, 5KN composite / polymeric Pin Insulator (20mm dia FP rod) No 165 11 KV, 5KN composite / polymeric Pin Insulator (24mm dia FP rod) No 195 e) 45 kn Disc Insulator No 290 f) 70 kn Disc Insulator(Ball&Socket type) No 490 g) 90 kn Disc Insulator(Ball&Socket type) No 490 h) 11 kv Solid core Insulator No 152 Included in stringing

XVI XVII i) Silcon rubber composite insulator / 11KV 45 KN Polymeric Insulator. No 170 j)11kv 70 KN Polymeric insulator. No 287 G I Wires & Guy Wires 7/10 SWG Guy Wire MT 56267 8 SWG GI Wire MT 54674 10 SWG GI Wire MT 57683 GI Barbed Wire 12 SWG MT 67882 Conductor a) Weasel ACSR km 20100 1913 b) Rabbit ACSR km 33676 2608 c) Coyote ACSR km 92708 4555 Providing guarding at Road Crossings, Telephone Line Crossings. (Including labour for fixing of necessary cross arms) Providing guarding between HT & LT line. (Including labour fixing of necessary cross arms) Providing guarding between HT & LT line. (Including labour fixing of necessary cross arms) mtr 68 mtr 68 mtr 68 603 (each upto a span of 60 mtrs) 603 (each upto a span of 40 mtrs) 1059 ( span of above 40 mtrs) a) Guy set with No.15 strain insulator & Concreting materials as per Drwg No. Set 742 354 BESCOM/GM/CP/7/Dt; 24.10.07 XVIII b) Guy set with 2Nos. 15 strain insulator & Concreting materials as per Drwg No. Set 775 374 BESCOM/GM/CP/7/Dt; 24.10.07 b) Guy set with No. 8 strain insulator & Concreting materials as per Drwg No. Set 723 354 BESCOM/GM/CP/7/Dt; 24.10.07 XX EG Stirrup With GI Lacing Set/2Nos. 370 99 XXI Spiral Earth Electrode Set 207 55 Anti climbing device (12 Mtrs GI Barbed wire) Nos. 64 25 XXII Caution / Danger Board Nos. 120 49 Distribution Transformer, 3-Phase, 11kV/433 V with oil a) 15 kva (Copper wound) Nos. 49980 682 b) 25 kva (Aluminium wound) Nos. 56480 682 c) 25kVA BEE - 3 Star rated (Aluminium wound Nos. 51560 682 c) 25kVA BEE - 4 Star rated (Aluminium wound) Nos. 54969 682 d) 63 kva (Aluminium wound) Nos. 81440 682 e) 63kVA BEE - 3 Star rated (Aluminium wound Nos. 93726 682 XXII e) 63kVA BEE - 4 Star rated (Aluminium wound) Nos. 94757 682 f) 100 kva (Aluminium wound) Nos. 101570 910

f) 100 kva (Aluminium wound) BEE 3-Star rate Nos. 121422 910 f) 100 kva (Aluminium wound) BEE 3-Star rated Nos. 125856 910 g) 250 kva (Aluminium wound) Nos. 228340 1365 h) 250KVA BEE 3 star rated/energy Efficient Nos. 292467 1365 h) 500 kva (Aluminium wound) Nos. 361707 1819 11 kv G O S XXIV a) 200 A Single break Set 6951 636 b) 400 A Double break Set 15637 706 c) 200 A Single break vertical operation Set 10096 636 XXV 11 kv Solid Core HG Fuse Unit Set (3 Nos) 827 423 XXVI 11kV Class DOLO Cutouts Set (3 Nos) 4288 423 XXVI 11kV Class DOLO Cutouts(REC design) Set (3 Nos) 3396 423 XXVII Lightning Arresters i) 9 kv, 5kA Metal oxide Type 3 Nos 2070 71 ii) 9 kv, 5kA Polymeric Type 3 Nos 3441 71 Transformer grounding XXVIII a) Pipe Type ( G.I. Pipe B -class with Strips bolt nuts and washers,salt, charcoal etc.,) Per Electrode 1277 573 b) Rod Type Set 2000 Concreting with Material & Labour Included in Material cost Base concreting CC 1:4:8 a) Pole base 11/9.5/9/8 mtrs Pole supports 500x650x150 mm 229 - b)pole base 9 mtrs square pole 650x650x150 mm 298 - c)pole base 11 mtrs spun pole 1000x1000x150 mm 704 - Pole concreting CC 1:2:4 (without coping) - XXIX a) 9.5 Supports(pole concreting) 650x500x1850 mm 2792 a) 9M Supports(pole concreting) 650x500x1700 mm 2566 - a) 9M Square Supports(pole concreting) 650X650x1700 mm 3214 b) 11M Tubular Supports(pole concreting) 1000x1000x2500 11378 c) 11 mtr PSC 650x500x2000 mm 2721 c) 7.5 / 8 M Supports 400x400x1500 mm 982 - a) Guy concreting with Boulders, Mud & Sand As per Drawing No. BESCOM/GM/CP/7 /dt: 24.10.07 158 XXIX Providing Coping for Poles with CC 1:2:4 (As per actuals) a) 150mm around poles for a height of 300mm for RCC, PSC, PCC Poles/ I- Beem/Rail steel sections. b)390mm all around the pole for an height of 300mm for Spun Poles Guy concreting in Marshy area: - - - each 444 each 1050

XXIX a) Providing cement concrete 1:2:4 for Anchor Rod in Marshy/Black Cotton Soil each 824 600x600x450mm XXX 11 kv, 3 Core XLPE UG Cable (Flat armoured) a) 3X95 Sq mm km 548860 35797 b) 3X240 Sq.mm km 1038890 37786 c)3x 400 Sq.mm km 1565000 39774 XXXI Fixing 3-phase LT Capacitor housed in a enclosure with necessary Fuses, wiring, mounting arrangement for 1 15/25 kva DTC, 3 kvar No. 725 382 2 63 kva DTC, 9 kvar No. 1131 382 3 100 kva DTC, 18 kvar No. 1933 450 4 250 kva DTC, 27 kvar No. 2958 525 5 500 kva DTC, 54 kvar No. 5083 549 XXXII Providing Electronic Trivector Meters with associated CT's Metering Box etc., on LT side of Distribution Transformer Center (including cost of energy meter) 1 for 15/25 kva DTC with CT ratio 50/5A Set 7912 1145 2 for 50/63 kva DTC with CT ratio 100/5A Set 7474 1145 3 for 100 kva DTC with CT ratio 150/5A Set 7168 1145 4 for 250 kva DTC with CT ratio 400/5 A Set 7330 1145 5 for 500 kva DTC with CT ratio 800/5A Set 7465 1145