Linde Hydraulics Corporation, P.O. Box 82, Canfield, Ohio 44406

Similar documents
LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

PRESSURE ADJUSTMENT Main pressure adjustment

Priority (Swing) Motors Data and Specifications

Document How to Set Single Stage Press Pressures

Lesson 6: Flow Control Valves

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

HYDRAULIC CYLINDER TEST

Model: 43T. Bermad Pressure Relief Valve

MADILL 24.7" 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

APPS-160 Gen 2 User Manual

Introduction. Part one: Identify the Hydraulic Trainer Components

WW-720. Pressure Reducing Control Valve

CASH VALVE TYPE KP BACK PRESSURE VALVES

(Refer Slide Time: 0:26)

PVQ 13 A2 R SE 1 S 20 C-11 D

Unit 24: Applications of Pneumatics and Hydraulics

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

FOR TM TURRET COMBAT ENGINEER VEHICLE, M728 ( ) TECHNICAL MANUAL

Yoke Block Instruction Manual

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

WW-720. Pressure Reducing Control Valve

WW-730. Pressure Sustaining/Relief Control Valve

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Yoke Block Instruction Manual

ANTI SHOCK RELIEF VALVE

Operating Procedure TITON SUBSEA BOLT TENSIONER

IFP C175-* REMOTE CONTROL RELIEF VALVE

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

BACK PRESSURE / SUSTAINING

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

BLEED DOWN OF THE HIGH GMA PRESSURE

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Air Operated Hydraulic Pumping Systems to 50,000 psi

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Pressure Reducing Control Valve w/ Hydraulic Check Feature

S & M Water Consultants

Full Range Pressure Compensating Variable Flow Control

Operation Manual Piston Sensed Gas Pressure Regulators

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Copyright, 2005 GPM Hydraulic Consulting, Inc.

BACK PRESSURE / SUSTAINING

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

BIOPAK 240R MAINTENANCE TOOL KIT. TOOL KIT PART NUMBER: B Revision A

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

Installation & Operating Instructions for Genesys Analog Series Manifolds

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Waterous Relief Valve

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Pneumatic Controls, Air Settings, Hydraulic adjustments on; Models 22HF, 16HF & 1600 machines

Bermad Pressure Reducing. Model: 42T

FRAGMENTATION INSTRUCTION & OPERATION HANDBOOK

PK-2D Service Manual

DBML-60/80 Squeeze Tool

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Operating Instructions for: PQ120 Pump Series. PQ120 Series Pump SPX

VACUUM REGULATORS CONTENTS

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

BRONZE BUSHING REPLACEMENT PROCEDURE DN345 & NL450C

TECHNICAL DATA. than the water inlet pressure to the concentrate

RP series Rotor Pumps

MANUAL BE SERIES Test Benches

! CAUTION! ! WARNING! General Information

Installation & Operating Instructions for Genesys Analog Series Manifolds

a. Next, lift the lever on pressure reducing valve to allow street pressure water into the system.

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

Tex-914-K, Calibrating Motorized Gyratory-Shear Molding Asphalt Press

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Hydraulic Piston Accumulators

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Heat Pump Connections and Interior Piping

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Reclaim Basic Set Up

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

LNG Regulator Test Kit

Installation Manual. Model # SF-3W 9/16/03 REV 1. Arch Chemicals, Inc Lower River Road. P.O. Box 800 Charleston, TN PULSAR

PRESSURE REGULATOR PRESSURE REDUCING. APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure

Ag Leader Technology Proportional Valve

Manual Solvent Purification System. Innovative Technology, Inc.

Operating Instructions Models and Hydrostatic Test Pumps

Removal of hydraulic load holding valve incident causing injury

SUPER PRECISION AIR RELAYS

BRAKE SYSTEM BLEEDING

Proper Pump Installation Practices

Models: C62/63/64-A/D

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Leak free Pipe Rupture Valve for Excavators

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

Leak-Free Load-Control Valve SAE ½ psi flange

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

Transcription:

Page 1 / 5 BPV..HF with Pressure Cut-off BPV..EH with Pressure Cut-off PURPOSE The purpose of the "PRESSURE CUT-OFF" is to prevent large amounts of oil from bleeding over a relief valve, which reduces overheating of the main loop in a closed loop application. The "PRESSURE CUT-OFF" reduces the control pressure of the pump so that the pump can stroke back towards neutral at a pre- determined maximum system pressure. Adjusting screws I and II are used to set the system pressure when the "PRESSURE CUT-OFF" becomes functional. Adjusting screw III determines the minimum pump flow going over the relief valve by establishing a minimum control pressure felt in the pump servo control once the "PRESSURE CUT-OFF" is active. P = System Pressure P1 = System Pressure at Maximum Flow P2 = System Pressure at Minimum Flow C = Control Pressure C1 = Control Pressure at Minumum Flow

SCHEMATICS Page 2 / 5 BPV...HF with Pressue Cut-off BPV...EH with Pressue Cut-off

TUBING DIAGRAM Page 3 / 5

ADJUSTMENT PROCEDURES Page 4 / 5 Port identification and adjustment locations: 1. INSTALL 1.0mm ORIFICES A. For "HF" control: One in each control pressure line. B. For "EH" control: One in control cover (see parts book). 2. PRE-ADJUSTMENTS A. Check for proper adjustment of Rb, hydraulic neutral, high pressure R/V settings and plumbing of BPV. B. To insure the proper function of the pressure cut-off valve, control presssure at Y & Z should be limited to a maximum of 21 bar (305 psi). C. Mount pressure gauges to monitor system pressure and the control pressure downstream of the control orifices. D. Turn in adjustment screws I and II until the ends of the screws are flush with the lock nut. This will block the pressure cut-off valve. E. Adjustment screw III should be turned all the way out, but not removed. 3. PRELIMINARY READINGS A. With the discharge of the pump blocked (closed lines, blocked motor or cylinder), very slowly increase the control pressure to the pump. As control pressure increases the pump's discharge pressure will also increase. Continue raising control pressure until the discharge pressure stablizes and remains constant. B. Note the constant discharge pressure and the corresponding control pressure to reach it for each direction of pump swash. C. To each control pressure reading, add 0.3 bar or 4.4 psi.

ADJUSTMENT PROCEDURES Page 5 / 5 4. FINAL ADJUSTMENTS A. Loosen adjustment screws I and II all the way out, but do not remove them. B. With the discharge of the pump still blocked, slowly introduce full control pressure to the pump, ie pump control valve in a fully open position. (The control pressure during this step should be below the control reading observed in step 38. If not, repeat steps 1 thru 4B). C. With full control on the pump, turn in the corresponding adjustment screw I or II (see chart below for relationship of adjustment screws to ports) until the calculated control pressure (step 3C) is registered on the appropriate control pressure gauge and lock adjustment screw with lock nut. Repeat procedure for opposite direction of pump swash, setting the appropriate control pressure reading from step 3C. D. Turn in adjustment screw III until the control pressure rises another 0.1 + 0.1 bar (1.5 + 1.5 psi) and lock with lock nut. 5. INCIDENTALS A. Since oil will be bleeding over the main relief valves during this procedure, watch the oil temperature in the main loop. B. Any change in hardware, control pressure supply or system configuration after the initial adjustments are made, will probably alter the performance of the pressure cut-off valve. In this event, readjustment is necessary to retune the pressure cut-off valve to accommodate the change. C. The "Pressure Cut-Off" valve can be used only in combination with "HF" and "EH" controlled BPV pumps. 6. RELATIONSHIP OF ADJUSTMENT SCREWS TO PORTS Control Port or Solenoid on BPV Pump System Pressure Port on Pressure Cut-off valve Corresponding Adjustment Screw Z B I Y A II