Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Similar documents
Installation Instructions JATCO Environmental Protection Tank Model J-7000

Shell & Tube. JATCO Inc. Operating Manual

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

CF-SERIES HIGH FLOW REGULATORS

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

RK LEL Sample Draw Aspirator Adapter Operator s Manual

SIDE 16 Sidemount System User Manual

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

480C DUAL PERFORMANCE VALUE PACK

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

Model 9201E Tempered Water Blending System

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

IMPORTANT SAFETY INSTRUCTIONS

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3070AT by Axiall Corporation

BS Series Basket Strainer

ACCU-MIX 1200 / / 26270

92831 TEL: (714) FAX:

4-in-1 Professional Inflator Kit

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

Accu-Tab Systems 2000 P Series by Axiall Corporation

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX

KJ4000 Operating Instructions & Parts Manual NSN

Cocoa Patio Pond with Lit Spillway

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Masoneilan* 78 Model Air Filter Regulator

SERIES BA TRASH BASKETS

FLOW CONTROL & AIR PILOT SWITCH VALVES

SC HYDRAULIC ENGINEERING CORPORATION

Model ASSEMBLY and OPERATING INSTRUCTIONS

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

GAS FRYER Instruction Manual Model #5099NS

SERIES L4E & L6E LADDER EXTENSIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

RAM 4021 Operation Manual

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

SERIES BB TRASH BASKETS

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

453 Series Steam Heated Vaporizing Regulator

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

J Air and Water Kit Instructions Part# 02584

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Prestan professional Training manikin

User Instruction Manual

INSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645

This document to be used with Hurley traditional Davits

EQUIPMENT Operation Manual. Loctite Stainless Steel Poppet Valve Part Number

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS

WEATHERIZING INSTRUCTIONS

Stainless Steel 142 mm Filter Holder YY

AIRMASTER SERIES RF AUTOMATIC DEWATERING VALVES. For the purging of water from compressed air systems WHERE DO YOU NEED AUTOMATIC DEWATERING VALVES

Standard Gas Countertop Griddle

STC 2KS/2KD Series Stainless Steel Angle Seat Valve

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

Please Do Not Return This Product To The Store!

Owner s Manual A VMAC Eliminator After-Cooler

Model Portable Eyewash

Sample Pro Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

MODEL 100 NITROGEN INFLATION CART

AIR HYDRAULIC RIVETER

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

Pressure Relief Valve Instruction Manual

Yoke Block Instruction Manual

MR/MRDC/MDC TECHNICAL APPLICATION GUIDE TABLE OF CONTENTS FOR MINI-REGULATOR WITH AND WITHOUT DRAIN CHECK OPTIONS

Operating Manual CBA Series Cascade Breathing Air Assemblies

AND OPERATION INSTRUCTIONS

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Offset head dual chuck

Operating and Maintenance Instructions

OPERATING INSTRUCTIONS

Gas Countertop Hot Plates

Accu-Tab PowerBase 3140AT by Axiall Corporation

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

PACKER OPERATING PROCEDURES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Masoneilan* Model 78-80S & 08-80S Transfer Valves

Transcription:

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX The JATCO Environment Tank must be installed at a level which will allow the waste liquids to be disposed of to gravity flow into the tank. IMPORTANT: The top of the tank must be below the level of waste liquids to be received. Inlet and the outlet check valves are both teed from the same port near the bottom of the tank (end opposite the sight glass). When facing this end the inlet check valve is on the left (see drawing point A ) and the outlet check valve is on the right (see drawing point B ). The discharge should be piped directly to the storage tank that is to receive the waste liquid. The discharge may be teed into an existing flow line, provided that a high pressure check valve (1000 PSI) is installed to prevent high pressure from returning to the discharge check valve on the JATCO tank. Supply Gas Pressure (40 PSI minimum) is connected to the bottom inlet of the micro-valve (point C) this Gas pressure must not exceed (100 PSI) for normal operation. No pressure regulator is provided as most applications for this device have regulated gas pressure supplied for engine fuel or burner gas. Manual dump plunger and gauge cock knobs removed for shipping. Manual Dump Plunger: Install in ⅛ NPT hole in top of valve body (see drawing point F ). Note: The gland nut should be finger tight only. Depressing the manual dump plunger allows the operator to check function of the float and micro valve. When the plunger is depressed, the tank will cycle once and return to the automatic operation. The plunger button should be returned to the extended position. Three way pilot valve (point G) is vented thru ¼ NPT port (point H). Liquid levels in the JATCO Tank may be observed in the sight glass furnished as standard equipment.

J 5000 CX (A) Inlet Check Valve 1 NPT (B) Discharge Check Valve 1 NPT (C) Supply Gas Inlet ⅜ Compression (D) ¼ Screen Vent (E) Pressure Relief Valve (F) Manual Dump Plunger Assembly (G) Three Way Actuated Ball Valve (H) Vessel Vent ¼ NPT (I) Gauge Cocks & Sight Glass

JATCO Inc. J-5000cx Tank Parts 3 6 1 8 2 9 7 5 10 No. Item# Description 1 JM5001X 3-Way Micro Valve w/mounting Plate 2 JM5002-100 SS Pressure Relief Valve 100 PSI 2 JM5002-200 SS Pressure Relief Valve 200 PSI 2 JM5002-100-IL ⅜" Stainless Steel In Line Pressure Relief Valve 100 PSI 2 JM5002-200-IL ½" Stainless Steel In Line Pressure Relief Valve 200 PSI 3 JM5003 Manual Dump Plunger Assembly 3 JM5003-G Greaseable Manual Dump Plunger Assembly 4 JM5004 Stainless Steel Float Arm & Pivot Assembly w/float 5 JM5005 1" Check Valve 6 JM5006 2" Valve Body Assembly 7 JM5007 10-Gallon ASME code vessel 8 JM5008X ¼" Pilot Valve 8-Kit JM5008x-Kit ¼" Pilot Valve Conversion Kit 9 JM5009 SS Gauge Cock Set 10 JM5010-100 Gauge Glass JM5010-200 Red Line Gauge Glass JM5011 Complete Float Control Assembly (Item #1, 3, 4, 6) JM5012 Complete Control Set (Item #1, 2, 3, 4, 6, 8) JM5012-200PSI JM5013 Complete Control Set 200 PSI ⅜" x ¼" SS Inline Filter STAINLESS OPTIONS No. Item# Description 1 JM5001x-SS 3 Way Stainless Steel Micro-Valve 6 JM5006-SS 2" Stainless Steel Valve Body Assembly 8 JM5008x-100-SS ¼" Stainless Steel Pilot Valve JM5008x-200-SS JM5008x-SS-100-Kit JM5008x-SS-200-Kit JM5011 SS JM5012 SS JM5012-200-SS J-5000-Box ½" Stainless Steel 3 Way Ball Valve w/actuator ¼" Stainless Steel Pilot Valve Kit ½" Stainless Steel 3 Way Ball Valve w/actuator Stainless Steel Complete Float Control Assembly Stainless Steel Complete Control Set 100 PSI Stainless Steel Complete Control Set 200 PSI Insulated Box Only (not assembled)

WARRANTY JATCO, Inc. warrants its products to be free from defects in materials and workmanship, under normal use and service, for a period of one year from the date of shipment. The sole liability and exclusive remedy is limited to the repair or replacement, at the option of JATCO, Inc., of the product, or any parts thereof, which upon examination by JATCO, Inc., disclose to its satisfaction defects due to faulty material or poor workmanship, and which defects are reported to JATCO, Inc., in writing, during the warranty period. The warranty provision contained herein shall not apply to or cover any defects resulting from normal wear and tear, unauthorized changes, repairs, alterations or modifications to the product: or any other causes beyond the control of JATCO, Inc. JATCO, Inc. neither assumes nor authorizes any other person or business organization to assume for it any other warranty or liability in connection with the sale, use or operation of its products.

JATCO INC. OPERATING MANUAL DISCLAIMER Except as otherwise expressly provided in the Warranty section of this manual, JATCO, Inc. does not warrant that the system or any of its components will work properly in all environments or under all conditions and makes no warranty or representation, express or implied, with respect to the quality, performance, merchantability, or fitness for a particular purpose of the system or its components. This operating manual is not intended as an installation guide for the product. This product is intended to be installed by an installation specialist. For a list of such installation specialists please contact JATCO, Inc. In the event the product is not installed by an installation specialist, the warranty provided in the Warranty section of this manual shall not apply to any defects, damage, or other failure of the product to properly function due to improper installation, and JATCO shall have no liability whatsoever for any loss, damage, injury, cost, or expense of any nature arising out of an installation of the product by anyone other than an installation specialist. The information in this manual is subject to change without notice. JATCO, Inc. makes no representations or warranties with respect to the contents of this manual. JATCO, Inc. reserves the right to revise this manual and to make changes from time to time in the content hereof without any obligation of JATCO, Inc. to notify any person of such revisions or changes. It shall be the user s responsibility to determine whether any changes or revisions to this manual have been made. Neither JATCO, Inc. nor any of its directors, shareholders, officers, employees, or agents shall be liable in contract, tort, or in any other manner whatsoever to any person for any loss, damage, injury, liability, cost or expense of any nature, including without limitation, incidental, special, direct, or consequential damages arising out of or in connection with the use of this manual. This manual is proprietary to JATCO, Inc. and no ownership rights in this manual or its contents are transferred to the user. No part of this manual shall be used, reproduced, translated, converted, adapted, stored in a retrieval system, communicated or transmitted by any means, for any commercial purpose, including without limitation, sale, resale, license, rental or lease, without the prior written consent of JATCO, Inc. Any product or component part names used in this manual that are not property of JATCO, Inc. are the properties of the respective owners of such products or component parts and each of JATCO, Inc. and the user acknowledge such ownership.