CO2 incubator with additional process controls

Similar documents
CO2 incubator with additional process controls

CO2 incubator with additional process controls

CO2 incubator with additional process controls

CO2 incubator with additional process controls

NEW: CO2 incubator with sterilizable sensor

NEW: CO2 incubator with sterilizable sensor

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

Thermo Scientific Heraeus BBD6220 CO 2 Incubators

CO2 INCUBATOR CO2 INCUBATORS

PERFORM Operating Document

PERFORM Operating Document

NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

MICROBIOLOGICAL CO2 INCUBATORS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Ultrasonic baths. XUB range of digital ultrasonic baths. XUBA range of analogue ultrasonic baths. Digitally controlled range with a choice of 5 baths

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Columbus Instruments

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Additel 761 Automated Pressure Calibrators

HumiSys HF High Flow RH Generator

CO2 Incubator. LCO-A Series

Additel 761 Automated Pressure Calibrators Selection Guide

with O 2 Controller Instruction Manual

Mass Flow Controller (MFC) for Gases

Additel 761 Automated Pressure Calibrators Selection Guide

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Oxygen Flue Gas Analyzer BA 2000

Additel 761 Automated Pressure Calibrators

Instruction and Maintenance Manual

MANUAL KPS Pressure Control Valve

We measure it. For gas and water installers. testo hpa. bar

KERN EG/EW Version /02

Precision pressure sensor Basic version Model CPT6020

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

Series Environmental Chambers

Mass Flow Controller (MFC) for Gases

Operating Instructions CO2 Incubator symphony 6.5 W

Continuous Gas Analyzers, extractive

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Customer Responsibilities

ADT 761 Automated Pressure Calibrator

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Additel 761 Automated Pressure Calibrators

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Online data sheet FLOWSIC30 GAS FLOW METERS

Instruction and Maintenance Manual

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Differential Pressure Transmiter

Mass Flowmeters. Mass Flowmeters for Gases

Installation and Operation Manual

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Model 601CV. Mass Flow Controller. Product Features:

Improve Process Reliability

FAS-W. Features. Applications. Automatic condensation hygrometer

Datasheet: K-30 ASCII Sensor

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

PRC CO ² -LASER PRESENTATION

EC214 EC215 - EC215R Bench Conductivity Meters

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Recirculating Coolers

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

Sartorius CCL kg Prototype Mass Comparator

NGN Series nitrogen generator

Qi Litre Ultrasonic Cleaner

Pressure transmitter PASCAL Ci4

BUBBLER CONTROL SYSTEM

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Hand-held pressure calibrator with integrated pump Model CPH6600

Gas density monitor With integrated transmitter Model GDM-100-TI

Mass Flow Meter (MFM) for Gases

Optical Dissolved Oxygen Meter

Optical Dissolved Oxygen Meter

490 Micro GC Site Preparation Checklist

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

SonoMeter 30 Energy Meters

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

HI 2314 HI 2315 HI 23151

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

Constant Pressure Inlet (CCN) Operator Manual

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

RADWAG Mass Comparators - ETERMA 2013 MASS COMPARATORS

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Transcription:

CB series 53 C2 incubators C2 incubator with additional process controls The BINDER C2 incubator CB series is the premium class for all sensitive incubation applications and best cell growth. Even during complex cultivation experiments or individual environments under hypoxic conditions, it is easy to grow thanks to a comprehensive assortment of options and accessories. Advantages: Hot air sterilization at 180 C Seamless, deep-drawn inner chamber made of stainless steel Unique BINDER technology (patented air jacket system, controlled condensation, etc.) Areas of application: Bio Tissue Engineering In vitro Fertilization (IVF)Clinics / University Hospitals 05.09.2011

Customer benefits Features Customer benefits Characteristics Sterilization Complete elimination of bacteria, spores, etc. Reliable sterilization of the atmosphere and all surfaces Minimal sterilization costs 180 C hot air sterilization Standards compliance, meets all relevant standards Automatic sterilization process Permadry humidity system APT.line heating technology Uniform osmotic cell pressure ptimum cell growth even with microwell plates No Provides no sources of contamination. ptimal, uniform cell growth throughout the inner chamber Controlled humidification system Defined recondensation point Dry interior walls High humidity Rapid humidity recovery times Simple water exchange through water pan Preheating chamber with VENTAIR air jacket Homogeneous temperature distribution Rapid recovery after temperature drop Accurate temperature control Gas distribution Stable ph value Gas mixing head with venturi effect Homogeneous C2 distribution Fast effective aeration Inner chamber concept C2 measurement perating costs Easy cleaning Fully usable volume 53, 150, 210 l No Provides no sources of contamination. Stable ph value even with frequent door opening Long-term stable system Low maintenance costs Minimal operating costs Time savings Seamless, deep-drawn inner chamber Integrated shelf support system Burr-free stainless steel perforated sheets with tilt protection Single-beam infrared sensor Rapid response time Measures C2 in real-time Independent of gas and humidity Minimal work and material costs for sterilization

Performance characteristics Electronically controlled APT.line preheating chamber assuring temperature accuracy and best cell growth Temperature range from 7 C above ambient temperature to 60 C MCS controller for temperature and C2 concentration User-friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real time clock Standard-compliant hot air sterilization at 180 C (DIN 58947) VENTAIR Jacket System Drift-free infrared C2 measurement system Patended Gas mixing nozzle Permadry System - condensation-free double-pan humidification system, maintains dry interior walls Seamless deep-drawn inner chamber made of stainless steel with integrated shelf support system (flanges) Electronic self-diagnostic system for errors with visual and audible alarms, as well as relay potential changeover contact for central monitoring Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm Tightly-fitted inner glass door RS 422 interface for communication software APT-CM DataControlSystem 2 perforated stainless steel shelves with standard equipement and 2 control Units are stackable with stacking adapter Door lock BINDER test confirmation

Specifications CB 53 Exterior dimensions Width (mm) 580 Height (incl. feet) (mm) 720 Depth (plus 55 mm for door handle and connection) (mm) 550 Wall clearance side / rear (mm) 50 / 100 Number of doors (ea.) 1 Inner glass door(s) 1 Interior dimensions Width (mm) 400 Height (mm) 400 Depth (mm) 330 Interior volume (l) 53 Number of shelves (standard/max.) 2 / 3 Dimensions shelves width x depth (mm) 396 x 289 Load per shelf (kg) 10 Permitted total load (kg) 30 Weight (empty) (kg) 60 Temperature data Temperature range from 5 C above ambient temperature to ( C) 60 Temperature variation at 37 C (± K) 0,3 Temperature fluctuation at 37 C (± K) 0,1 Recovery time after door was opened for 30 sec. at 37 C (min.) 1) 3 Humidity data Humidity (% RH) 95 C2 data C2 range (vol. % C2) 0-20 Setting accuracy (Vol.-% C2) 0,1 Recovery time after door was opened for 30 sec. 1) at 5.0 vol. % C2 (min.) 6 C2 measurement IR Connection hose nozzle for C2 for hose with internal diameter (mm) 6

Specifications CB 53 2 data 2 range (vol. % 2) 0,2-95 Setting accuracy (Vol.-% 2) 0,1 Recovery time after door was opened for 30 sec. 1) at 1.0 vol. % 2 (min.) 25 at 5.0 vol. % 2 (min.) 9 2 measurement Zr2 Connection hose nozzle for 2 / N2 for hose with internal diameter (mm) 6 Electrical data Voltage (± 10%) 50/60 Hz (V) 230 Nominal power (kw) 1,0 Energy consumption at 37 C (W) 2) 70 1) up to 98 % of the set value 2) These values can be used for dimensioning air condition systems. All technical data are specified for units with standard equipment at an ambient temperature of 25 C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

ptions BINDER Gas Supply Service The external tank changer makes automatic changeover to a second tank possible once the first tank is empty. It has acoustic and visual alarms and is equipped with a zero-voltage alarm output for extreme notification systems. It can be used for maximum two C2 incubators and is suitable for C2, 2 and N2 tanks. Gas-tight, 4-way divided inner glass door For stable climate conditions in the broad chamber. Minimal loss of humidity, heat, and C2 when loading. Ensures short recovery times. Control for variable 2 values For hyper- or hypoxic culture conditions. The 2 or N2 gas supply can be controlled using an additional control loop as needed. A zirconium oxide sensor (Zr2) is used for the measurement. Silicone access ports For introducing external measuring instruments into the chamber. The access ports have a diameter of 30 mm and can be sealed on both sides using a silicone plug. They can be positioned on the back, left, and right sides. Stacking adapter Used for stacking of two CB incubators which are thermally isolated from each other. The incubators can thus be sterilized with hot air independent of each other. Available as stacking adapters, stacking frames or base frames. APT-CM DataControlSystem GLP Edition Software for GLP-compliant control, programming and documentation. Allows networking of up to 30 devices or controllers. Meets FDA 21 CFR Part 11 requirements. Calibration certificate & validation BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do.

ptions CB 53 Silicone access port with two silicone plugs, 30 mm, back Lockable controller keyboard Gas tank connection set for C2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m hose Gas tank connection set for 2 consisting of a gas tank pressure regulator (max. pressure 10 bar) with connection parts and 5 m hose Gas tank connection set for N2 consisting of a gas tank pressure regulator max. pressure 10 bar) with connection parts and 5 m hose BINDER Gas Supply Service external gas tank replacement for connecting 2 gas tanks, either C2 or N2, with audible and visual alarms, as well as potential-free alarm output Unit conversion from RS 422 to Ethernet interface 4-20 ma analog outputs for temperature and C2 measurements (e.g. chart recorder connection) with 6-pin DIN socket (output not adjustable) Switched LEM inner chamber socket (coverable) and LEM connector (max. current carrying capacity 230 V AC - 3 A) (protection class IP 65) Independent Intelligent Fail Safe monitoring function. Unique safety function used to prevent unnoticed deviations of the C2 concentration from the set value. Note: Not possible in conjunction with access ports or divided inner glass door Calibration certificate for temperature and C2 (temperature measurement in center / C2 measurement performed using analyzed test gas at 37 C and 5% C2) Calibration certificate for optional 2 control, 2 measurement with analyzed test gas 1% 2 Temperature measurement acc. to DIN 12880 (27 measuring points) at 37 C or at specified temperature with measuring protocol and certificate Manual for Primary Human Cell Culture, in English Shelf, perforated, stainless steel Shelf, stainless steel for divided gas-tight inner glass door Base on casters Stacking adapter for direct thermal decoupled stacking of two C 53 C2 incubators

C CB PRDUCT SELLING GUIDE BINDER C 2 -Incubators ptimal cell growth - thanks to hot air sterilization at 180 C seamless one-piece inner chamber unique BINDER technology (patented Air jacket system, Single condensation point,...) Applications: Bio Tissue Engineering Cell Biology Basic Research In-Vitro Fertilization (IVF) BINDER features Customer benefits What the competition offers Sterilization Bio Tissue Engineering State of the art 180 C hot air sterilization ff Total elimination of germs, spores, Hot air sterilization Cell Biology at 180 C in Basic Research etc. that could In-Vitro damage cell Fertilization cultures accordance with standards ff High availability (IVF) at low operating cost, Automatic sterilization process overnight sterilization procedure Disinfection does not eliminate all contamination, since not all germs, spores, etc. are destroyed Expensive time and labor-intensive and complicated decontamination procedure Permadry humidification Single Point Condensation and humidification system Dry inner walls at all times Rapid humidity recovery High humidity ff No contamination to damage your cell cultures ff smotic cell pressure is balanced ff ptimum cell growth. This is especially important when cultivating open cultures in microwell plates Wet inner walls or doors promote contamination Contamination can destroy your cell cultures APT.line Ventair air jacket Air jacket heating system Homogenous temperature distribution Rapid temperature recovery, precise temperatures ff ptimum cell growth in the entire inner chamber Sluggish temperature recovery, especially with water jacket systems Uneven temperature distribution Unique Gas mixing head Unique Gas mixing head with venturi effect No fan u no contamination of cell cultures with airborne particles Homogenous C2 distribution ff No contamination to damage your cell cultures ff Stable ph for optimum cell growth Use of fans can contaminate cell cultures with airborne particles. HEPA filters represent an additional risk of trapping contamination below the chamber ceiling. Risk of recontamination Risk of unsatisfactory ph conditions ne piece inner chamber Seamless chamber with built-in shelf supports Unique, easy-to-clean seamless design No fittings in the interior chamber means optimum space utilization ff No contamination to damage your cell cultures ff Large working space Labor and time-intense cleaning procedure, because of multiple interior fittings in the chamber which must be removed for cleaning The numerous interior fittings particularly reduce the available working space IR Sensor ph stability independent from humidity IR sensor measures immediately after door is opened Rapid C recovery after door is opened; 2 buffer solution ph remains constant even when door is frequently opened ff Ensures optimum cell growth even when door is frequently opened ff IR is independent measuring of C 2 /ph Low quality TC sensor cannot measure C 2 concentration for about 30 minutes after the door is opened, because TC sensors need stable humidity to measure the C 2 concentration Unstable buffer solution ph when door is opened frequently Cost of ownership Requires no HEPA filter replacement Fully automatic hot air sterilization at 180 C, compliant with standards No manual / chemical cleaning ff Low operating cost ff Low cost of ownership Between $ 670 and $ 1140 annual cleaning cost (labor and material) per year Requires cleaning at least once a month FR INTERNAL USE AND AUTHRIZED PARTNERS NLY!

C CB PRDUCT SELLING GUIDE Product program at a glance C 150 CB 53 CB 150 CB 210 Interior volume (l/cu.ft.) 150 / 5.4 53 / 1.9 150 / 5.4 210 / 7.5 Interior dimensions (mm/inch) Width Height Depth 500 / 19.7 600 / 23.6 500 / 19.7 400 / 15.7 400 / 15.7 330 / 13.0 500 / 19.7 600 / 23.6 500 / 19.7 560 / 22.1 750 / 29.5 500 / 19.7 Exterior dimensions (mm/inch) Width Height Depth* *plus 50 mm (2.2 inch) I-triangle, door handle and connections 680 / 26.8 819 / 32.2 815 / 32.1 580 / 22.8 720 / 28.3 546 / 21.5 680 / 26.8 919 / 36.2 715 / 28.1 740 / 29.1 1069 / 42.1 715 / 28.1 Temperature range 7 C / 13 F above ambient up to 50 C / 122 F 5 C / 9 F above ambient up to 60 C / 140 F 7 C / 13 F above ambient up to 60 C / 140 F 7 C / 13 F above ambient up to 60 C / 140 F C 2 - range (Vol.-%C 2 ) 0-20 0-20 0-20 0-20 Humidity values (% RH) 95 95 95 95 Recovery time after door was opened for 30 sec. at 37 C (98.6 F) (Min) 5 3 3 3 ptions Gas-tight, divided inner glass door (CB series) Additional information Catalog Scientific products Flyer C 2 incubators 2 controller (CB series) Gas Supply Control Unit Stacking frame - Information and technical data contained in this flyer are subject to alteration

Wolf Laboratories Limited www.wolflabs.co.uk Tel: 01759 301142 Fax:01759 301143 sales@wolflabs.co.uk Use the above details to contact us if this literature doesn't answer all your questions. Pricing on any accessories shown can be found by keying the part number into the search box on our website. The specifications listed in this brochure are subject to change by the manufacturer and therefore cannot be guaranteed to be correct. If there are aspects of the specification that must be guaranteed, please provide these to our sales team so that details can be confirmed.