Instructions for Use (IFU) Electrical Leg- & Arm lift, model 2009-01, ver. 2012 1 Opitek International
Always be careful and pay attention when using the equipment to avoid over strain of limbs. To avoid instability of the lift, place the long part of the wheel base closest to the patient. Photos in this IFU may vary from the delivered model. Charging of the battery pack The battery on the equipment is best charged continuously (over night or when not in use). Use only the adaptor that was delivered with the lift. The orange indicator lamp charge lights up during charging and changes to green on full charge. If the empty signal is blinking you will have to start charging, but one or two lifts are always possible. An audio signal is heard when the battery is almost empty. The safety on / off switch (red knob) is engaged when the knob is pushed in. Full functionality is restored by turning the knob in the direction of the arrows. See the operating manual MCU (battery pack and control box) for further information. In case of loss of power, one downward movement is always possible by pressing the yellow emergency down contact, located at the bottom of the control box next to the connector for the charging adaptor. Lifting of one leg at the ankle Lifting of one leg can be done by using the lifting strap with article number 2006-50 around the patient s ankle. Place the lift alongside the OR table with the longest part of the wheelbase of the lift under the OR table. Lock the wheels (as a minimum the two wheels under the control box) and raise or lower the limb by pressing the respective buttons (up / down arrows) on the hand control until the desired height level is achieved. The lifting arm can swivel to achieve the desired position. 2 Opitek International
Lifting of one leg at the foot arch Lifting strap with Velcro (article 2006-60) can be used to lift at the foot arch. Place the lift alongside the OR table with the longest part of the wheelbase of the lift under the OR table. Lock the wheels (as a minimum the two wheels under the control box) and raise or lower the limb by pressing the respective buttons (up / down arrows) on the hand control until the desired height level is achieved. The lifting strap can be secured towards sliding off by placing 2 Velcro self adhesive coins (article number 2006-65) on the outer and inner side of the patient s foot and attaching the Velcro band of the 2006-60 strap to these 2 coins. The lifting arm can swivel to achieve the desired position. Velcro coin (article 2006-65) Lifting of 2 legs simultaneously Place the cross bar at a 90 degree angle on the short lifting arm by means of the cut-out in the cross bar. Use lifting strap 2006-50 or alternatively 2006-60. Place the lift at the short end or alongside the OR table with the longest part of the wheelbase of the lift under the OR table. Lock the wheels (as a minimum the two wheels under the control box) and raise or lower the limb by pressing the respective buttons (up / down arrows) on the hand control until the desired height level is achieved. The lifting arm can swivel to achieve the desired position. 3 Opitek International
Lifting of one leg with patient in prone position Place the cross bar at a 90 degree angle on the short lifting arm by means of the cutout in the cross bar. Use lifting strap 2006-70 (set with one Velcro band and one wide strap). Place the lift parallel to and alongside the OR table with the longest part of the wheelbase of the lift under the OR table. Lock the wheels (as a minimum the two wheels under the control box) and raise or lower the limb by pressing the respective buttons (up / down arrows) on the hand control until the desired height level is achieved. The lifting arm can swivel to achieve the desired position. The wide strap is placed around the thigh just above the knee joint and the Velcro band is fixed at the foot arch or around the ankle. Cleaning and disinfection: To clean the lift a mild soap solution and a soft cloth can be used. Do not soak any parts and do not leave any surface wet for longer periods of time. The surfaces can if needed be wiped with a disinfection agent (see cleaning and disinfection manual for details). Product Article number Leg lift complete system 2009-01 Package with remote control (cordless option) 2012-01 Spare Hand Control (with spiral cord) 9097140015 Spare battery 9097150009 Lifting strap without Velcro, min. 50 pcs. 2006-50 Lifting strap with Velcro, min. 50 pcs. 2006-60 Velcro coins, package of 50 pcs. 2006-65 Lifting strap for prone position, 1 set 2006-70 Guarantee 1 year. Expected lifetime of the battery is approx. 3 years. Lifting maximum capacity: 250 kg 100 kg (0cm 50cm from the center). Breakage test lifting strap 2006-50: max. 1262 N (approx. 125 kg) Breakage test lifting strap 2006-60: max. 323N (approx. 30kg) Manufacturer: Opitek International, Naverland 1C, DK-2600 Glostrup, Danmark Tel: +45 3966 1644, Fax: +45 3966 1655 www.opitek-international.dk info@opitek-international.dk 4 Opitek International
Accessories for Limb Lifter Foot Sling Code 2006-60 Velcro Locks for Foot Sling Code 2006-65 Ankle Sling Code 2006-50 Abdominal Sling Code 2006-70
Instructions for Care, Cleaning and Disinfection Electrical Leg- & Armlift Article 2009-01 WARNING Do not use alkali or acidic substances for routine cleaning purposes. Substances used should be ph neutral (6-8). Always disinfect after cleaning if a biological contamination of the device is visible or suspected. The frequency of routine cleaning will depend on the use of the device. Cleaning / Disinfection: Please observe the following before starting cleaning / disinfection procedures: Use suitable personal protective measures to protect yourself from stains. Disconnect all electrical connections from both the low voltage adaptor and the mains. Place the device on a suitable and stable surface and lock the wheels. Ensure that all openings in the bottom of the controlbox are closed properly (see pos. 1 and 2, fig. 1). Lift up and remove the 50cm lifting arm (and the 2-leg cross bar if mounted) from the top of the lifting cylinder and clean/disinfect the parts separately (se fig. 2) Cleaning: a) Use a clean soft cloth with warm (max. 65º C) water and a mild, neutral soap solution and wash the lift from the top and downwards avoid excessive fluid in the areas around the battery, controlbox and handcontrol. b) Wipe the lift thoroughly from the top and downwards with a soft cloth and clean water. c) Wipe the lift dry thoroughly with a soft cloth or paper napkins If disinfection is needed repeat steps a) to c) while using a solution of Sodium Hypochlorite (dilution 1/100 10.000 ppm) in stead of warm water and soap. On the plastic parts (black connecting pieces between outer and inner tube, battery/control box and the hand control with cable) a 70% isopropyl alcohol solution should be used to avoid discoloration and material fatigue due to Sodium Hypochlorite. Opitek International Naverland 1C 2600 Glostrup Denmark Tel.: +45 3966 1644 Fax: +45 3966 1655 mail@opitek-international.dk www.opitek- international.dk VAT number: DK30554582 Bank: Danske Bank SWIFT-BIC: DABADKKK DKK account number: 1471-4768208972 IBAN: DK45 3000 4768 2089 72 SEK account number: 1471-4260565834 IBAN: DK58 3000 4260 5658 34 EUR account number: 1471-4260565842 IBAN: DK36 3000 4260 5658 42
Do not soak any parts of the lift in liquid. Mount the 50cm lifting arm (and the 2-leg cross bar if needed) on the top of the lifting cylinder. Do not use lubrication. Fig. 1 Correctly closed control unit with properly connected actuator(s), control device, sealed mains adapter input (1) and sealed actuator input (2). The control unit would be damaged by fluid entering it. If the unit becomes dirty, the housing should best be cleaned immediately in order to prevent the accretion of residues. The control unit has been manufactured according to protection class IPx4. Fig. 2 Electrical leg- & Armlift complete with 50cm lifting arm and 2-leg cross bar. Opitek International Naverland 1C 2600 Glostrup Denmark Tel.: +45 3966 1644 Fax: +45 3966 1655 mail@opitek-international.dk www.opitek- international.dk VAT number: DK30554582 Bank: Danske Bank SWIFT-BIC: DABADKKK DKK account number: 1471-4768208972 IBAN: DK45 3000 4768 2089 72 SEK account number: 1471-4260565834 IBAN: DK58 3000 4260 5658 34 EUR account number: 1471-4260565842 IBAN: DK36 3000 4260 5658 42