STARLOG. Capacitive Water Depth Probe

Similar documents
Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

BUYER S GUIDE AQUAlogger 530WTD

Technical Data Sheet MF010-O-LC

Installation and Operation Manual

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

Gas Pressure Probe. Information Sheet. Total Dissolved Gas

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

ACV-10 Automatic Control Valve

Elcometer ISO Groove Depth Checker. Operating Instructions

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Preferred Instruments Danbury, CT USA

Sensoric 4-20 ma Transmitter Board Operation Manual

Q2: Which instruments are necessary for monitoring the groundwater level?

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

FTC130 Transmitter. Operating Manual

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

NOVALYNX CORPORATION MODEL BAROMETRIC PRESSURE SENSOR PCB MODEL BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL

USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

AMS 2710 PCB pressure sensor module with V output

NOVALYNX CORPORATION MODEL ANALOG OUTPUT EVAPORATION GAUGE INSTRUCTION MANUAL

Expert Hydrostatic Level Transmitters

200A Series ELECTRONIC LEVEL TRANSMITTER

Owners Manual Release Date: Thursday, December 29, 2011

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

Elcometer 123. Surface Profile Gauge. Operating Instructions

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Accuracy under pressure.

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Heavy Duty Dissolved Oxygen Meter

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

PH01 Perfusion Cannula Manual

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

SX150A. Features. Typical Applications. Description

Location of CC Number if not located with the identification:

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

HOBO U20L Water Level Logger (U20L-0x) Manual

Onset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate

High-performance submersible pressure transmitter For level measurement Model LH-10

RDO Optical Dissolved Oxygen Sensor

SDX Submersible Depth Transmitter User Manual

Met One E-BAM Particulate Monitor

T EK-SUB 4800C 19 mm Submersible Level Transmitter

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

BUYER S GUIDE AQUAlogger 520

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Oxygen Sensor with Electrode

QUICK START GUIDE TO DRINKING WATER MONITORING

EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS

Variable Area Flow Meters

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

NEULOG OXYGEN LOGGER SENSOR GUIDE

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Elcometer Viscosity Cup. Operating Instructions

_ pressure transducers. User Manual

Design Features. General Description

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

DTG - LCD Digital Temperature Gauge USER MANUAL

UNDERSTANDING, ACCELERATED

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

SDX Submersible Depth Transmitter User Manual

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, Operation, and Maintenance Manual

MANUAL KPS Pressure Control Valve

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

BAPI Pressure Line of Products - FAQs

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

HOBO U20 Water Level Logger (U x and U x-Ti) Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

MODEL GT820 OXYGEN SENSOR

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

Agilent Flowmeter ADM1000

Procedure Troubleshooting the Interconnect Cables

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

AMS 6916 Board mount pressure sensor with ratiometric analog output

User manual CF8-D/W-IN

SITRANS P measuring instruments for pressure

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Level MEASUREMENT 1/2016

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

Pressure Measurement Single-range transmitters for general applications

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

High-performance submersible pressure transmitter For level measurement Model LH-10

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Precision pressure sensor Basic version Model CPT6020

3.0 Pressure Transmitter Selection

Pre-Calibrated Models

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

Running the LiCor 6400 Infra Red Gas Analyzer (IRGA) with 4 whole-plant cuvettes attached

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Transcription:

STARLOG Capacitive Water Depth Probe Model 6521 User Manual Supplement 6219 Revision D July 10. 1998

Copyright Notice Copyright Unidata Australia 1998. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without prior written permission of Unidata Australia, 3 Whyalla Street, Willetton, Western Australia, 6155, Australia. Published by MacLaren Enterprises Printed in Australia IBM is a registered trademark of International Business Machines Corp.

Table of Contents 1. INTRODUCTION.............................. 1 2. USING THE PROBE IN A STARLOG SCHEME..... 2 2.1. CHOOSING A LOGGER............................. 2 2.2. NOTES ABOUT A WATER DEPTH MONITORING SCHEME......................................... 2 2.2.1. Adding an Instrument................................ 2 2.2.2. What to Log....................................... 3 3. INSTALLATION.............................. 4 3.1. CABLING......................................... 4 3.2. CONNECTIONS................................... 4 4. CLEANING.................................. 5 4.1. STAINLESS STEEL PROBES........................ 5 5. CALIBRATION............................... 6 6. SPECIFICATIONS............................ 7 Contents - i

ii - Contents

1. INTRODUCTION The Capacitive Water Depth Probes (model 6521) are designed for high resolution measurement of small water depths using the dielectric characteristics of water. The probes are factory calibrated to standard ranges. The Capacitive Water Depth Probes can be cleaned easily in the field and have been designed to measure water depths in most environmental conditions. They are not affected by algae or sewage but consideration should be given to the use of capacitive water depth probes in situations where the dielectric constant of water may have been lowered significantly. Salt water and highly ionic water raise the dielectric constant only slightly and do not affect the accuracy of the water depth probe. These probes are not designed for measuring the depths of non-ionic liquids such as hydrocarbons (for instance, petroleum). The probes available from UNIDATA are: Model 6521J 0 to 0.5 metre Model 6521K 0 to 1.0 metre Model 6521L 0 to 2.0 metres Model 6521L Capacitive Depth Probe INTRODUCTION - 1

2. USING THE PROBE IN A STARLOG SCHEME UNIDATA s Capacitive Water Depth Probes are designed for automatic monitoring and collection of water depth in a STARLOG Data Logging System. When the probes are connected to a STARLOG Data Logger, data sensed by the probes is logged and stored according to a program you define using STARLOG Software. STARLOG Software runs on a computer compatible with IBM systems (PC/XT/AT, PS/2). This package includes a menu-driven program so that you can easily generate a data logging program called a Scheme then load the Scheme into a Data Logger. To discover how to use this program see the STARLOG Users Manual (supplement 6203 or 6245). This section provides you with information you will find helpful in creating and executing a Water Depth Monitoring Scheme using the current version of STARLOG Software, Version 3. 2.1. Choosing a Logger Any of the STARLOG range of Data Loggers can be used with this instrument to record water depth and temperature. Each Logger offers Analog channels with sufficient resolution to record data sent by the instrument. In fact, an 8-bit channel is sufficient for most water depth & temperature monitoring projects. When connecting the instrument to a STARLOGGER (Model 6004) or MACRO Data Logger (Model 7000) you will want to program the Logger for PDL compatibility mode which will configure Analog channels for 8-bit resolution. This is automatic via Version 3 Software. When using Version 2 Software, consult the Users Manual 6203. 2.2. Notes About a Water Depth Monitoring Scheme This section describes the probe s attributes and suggests how you might want to use data gathered. 2 - USING THE PROBE IN A STARLOG SCHEME

2.2.1. Adding an Instrument To create a Water Depth Monitoring Scheme, select a Probe from the Instrument List to add it to the Scheme. If the model you have does not appear in this list, you will want to add it. (Use the Instrument Editor in Version 3 or Maintain Instruments in Version 2.) Once you add the instrument to the Scheme, check to see which channel is allocated, scaling factors, format of data shown in reports, etc. The default settings are: Whether you create a new instrument for this list or edit one of the existing instruments, you will want to ensure that the transducer has the appropriate attributes. You can check this when you add the instrument to a Scheme. An instrument s input channel can be changed at this time. USING THE PROBE IN A STARLOG SCHEME - 3

2.2.2. What to Log For the Capacitive Water Depth Probe, you are most likely to want to log raw, minimum or maximum data or an average over the log interval or an average over a sub interval. You could also trigger logging by an event, for instance, you could log the average depth over a 30 minute interval every time water rises above 1 metre. 4 - USING THE PROBE IN A STARLOG SCHEME

3. INSTALLATION 3.1. Cabling The recommended cable is three core low voltage data cable. See the section below for connection details. The cable length, from the instrument to a STARLOG Data Logger, should be kept to a minimum to avoid electrical noise and signal fading. A maximum of 30 metres is recommended. 3.2. Connections The Capacitive Water Depth Probes are connected to analog channels of the STARLOG data loggers. Connection details for the default channel, Analog 0, are as follows: Wire Colour Function STARLOGGER & PDL MACRO Data Logger Pin Term Pin Term Red 5V output power from logger 13 17 18 49 White analogue input channel (a0) or (A0) of Macro 1 39 20 39 Black logger common (ground) 23 41 1 40 In the table above, Pin refers to the pins of the INPUT SIGNALS connector on a Data Logger, while Term is an abbreviation for numbered screw terminals on a Field Termination Strip. Information in the Term columns appears in bold type as this is the connection method you are most likely to use. Refer to the Supplement included with your Logger or Field Termination Strip for more information about these connections. Note: This table also shows connection details for h0 hi-res 0 of the Macro Data Logger (i.e., the same as A0). INSTALLATION - 5

4. CLEANING The inner conductor should be kept clean to ensure optimum performance and it it is recommended that it be cleaned every three months when used under normal conditions. More frequent cleaning is required under less ideal conditions. 4.1. STAINLESS STEEL PROBES A quick method of cleaning is to fill the tube with methylated spirit and shake the probe to loosen any sedimentary build-up. If the build-up is not great, water may be as effective. Top View A more thorough cleaning may be achieved by the removal of the probe s inner conductor. It can be removed with the following steps: 1. The teflon wire which is lightly tensioned is attached to a spacer at the bottom of the sensor tube. To free the wire carefully pull, slide the metal ring off the spacer. 2. Remove the set of screws just below the plastic housing. The housing can now be twisted and removed. 3. The teflon wire can now be cleaned using soaps and gentle rubbing. The inside of the stainless steel tube should also be inspected for refuse and cleaned if required. 4. To replace reverse the procedure taking care not to scrape the Range Markings of Probes 6 - CLEANING

teflon wire along the sharp edge of the stainless steel tube. The metal ring located at the bottom of the wire slips back into the bottom spacer. 5. The calibration should not be affected by this operation providing care is taken and the top cover is not removed. CLEANING - 7

5. CALIBRATION The instrument has been factory calibrated. The two concentric grooves on the stainless steel tube represent the effective calibrated length of the sensor. The lower mark represents a water depth of 0m and the upper 0.5m, 1.0m or 2.0m. This instrument can be field calibrated. Zero and fullscale are located on the probes as shown below. You can adjust the offset and the gain of this instrument via two trimmers (trimming potentiometers) inside the housing. 1. To access the trimmers, unscrew the plastic top cap. The Gain and Offset trimmers are visible inside the tube. 2. Adjust the offset to read 0 when probe is submerged to the Zero mark of the probe. 3. Adjust the Gain to read fullscale when probe is submerged to the fullscale mark. 4. Repeat at least once to confirm the readings. 5. Reassemble the probe when calibration is complete by reversing this procedure. 8 - CALIBRATION

6. SPECIFICATIONS Range: Power Consumption: Output Signal: Accuracy: Linearity: Resolution: Diameter: 0 to 0.5 metre model 6521J 0 to 1.0 metre model 6521K 0 to 2.0 metres model 6521L 5V DC, 3.5 ma (3.5% of battery life) 0 to 2.55 V DC full scale 0.5% of full scale reading 0.1% of full scale reading continuous 40 mm main body 65 mm at widest point SPECIFICATIONS - 9

10 - SPECIFICATIONS This page left intentionally blank.