A TYPICAL AERATION UPGRADE CONSIDERATIONS AND OUTCOMES. Michael Young. Michael Young, Director, Faraga Pty Ltd and Aer-Force Pty Ltd

Similar documents
aeration and mixing systems

CTB3365x Introduction to Water Treatment

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

Technical Bulletin 160. Maximum Air Pressure for Diffusers. by:

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure

Fine Pore Aeration Systems Testing Michael K. Stenstrom Professor, Civil and Environmental Engineering Department

Supratec AERATION TECHNOLOGY. von-drais-straße 7 D Simmern / Hunsrück. tel.: / fax: /

Siting and Installation Manual

NOTICE. Issued: February 12, 2010 AO# Dundas Street West, Oakville, ON CANADA Phone: (905) Fax: (905)

Toronto Water Ashbridges Bay Treatment Plant Aeration Tank 2 - Process Control Narrative

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

IMPROVING PLANT AERATION USING GAS INFUSION TECHNOLOGY

Technical Bulletin 161. How Deep Can I Design my Aeration Tanks? by:

Red Valve Coarse and Fine Bubble Air Diffuser Systems

UTILIZATION OF LEAKY PIPES AS AERATION SYSTEM FOR AQUACULTURE

Supratec. MEMBRANE-PLATE-DIFFUSER For fine bubble aeration of liquids BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)

Supratec. von-drais-straße 7 D Simmern/Hunsrück Fon: +49 ( 67 61) Fax: +49 ( 67 61)

Disc diffuser ELASTOX -T

SECTION BIOLOGICAL TREATMENT SYSTEM FUNCTIONAL DESCRIPTIONS

Oxygen mass transfer in a bubble column with non-newtonian fluids

CCT-7320/ROC-2313 Reverse Osmosis Controller

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

Technical Service Bulletin March 2015 TSB142.01

KRONES filling systems for beer Filling of glass containers and cans

AquaDDM. Direct-Drive Mixer. Often Imitated Never Duplicated

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration

Supratec von-drais-straße 7 D Simmern/Hunsrück Fon: *49 ( ) Fax: *49 ( )

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

FINE BUBBLE DISC DIFFUSER

Liquid Thin Film Technology

INSTALLATION INSTRUCTIONS FOR THE SSI TUBE DIFFUSER General

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

TURBO OXYGEN NITROGEN PLANT

Huntsman Corporation Australia Pty Ltd. Botany Site NSW. Environment Protection Licence Reporting Period: to

Panel diffuser ELASTOX -P

Royce Interface Level Analyzer and Sensors

Straightforward, Solutions. The power of innovation. BioMix TM Compressed Gas Mixing

MULTI AERATOR (PACHUKA VALVE)

The activated sludge process

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

PROCESS AND AERATION OPTIMISATION USING ONLINE OFFGAS ANALYSIS

OWNER S TECHNICAL MANUAL

Expert Hydrostatic Level Transmitters

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

Performance Monitoring Examples Monitor, Analyze, Optimize

Ingersoll Rand. X-Series System Automation

Biodec Decanter. Ideal with our CYCLATOR technology

VACOMASS. The modular air supply system in wastewater treatment plants

Copeland Discus with CoreSense Diagnostics January 2011

Fine Bubble Tube Aeration System O&M Manual INSTALLATION INSTRUCTIONS FOR THE SSI TUBE DIFFUSER

Hazard Operability Analysis

Sewage aeration systems

IT STARTS AT THE SOURCE - RE-CALIBRATING YOUR PLANT METERS

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Transient Analyses In Relief Systems

Operational Settings:

Proportional valves with piezo technology in medical technology

ENVE 301 Environmental Engineering Unit Operations

Aeration of Dugouts or Ponds with Compressed Air

UsER manual for Watersens ph -REDOX

Contents. Foreword. Acknowledgements. General Introduction

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

CO 2 and O 2 scrubbers

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ASERCOM guidelines for the design of multiple compressor racks using frequency inverters

OXYGEN TRANSFER CAPABILITIES CANADIANPOND.CA PRODUCTS LTD.

Measurement Technology

QuickHeat TM Packaged Heat Exchanger Solutions

acculink platinum zv zoning system

SEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Characterizers for control loops

Integrating Aeration Blowers with Most-Open-Valve

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Rotary vane steering gear for smaller vessels

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Unit 24: Applications of Pneumatics and Hydraulics

ekom Compressor for Medical Air Sonata with Ekom

ENS-200 Energy saving trainer

STARLOG. Capacitive Water Depth Probe

Topline Peristaltic Dosing Pump for PAC Installation, Commissioning and O&M Manual

The Future of Hydraulic Control in Water-Systems

Trifecta High-Pressure Systems

Pool and Spa. Water Testing

Model EXAxt AV550G. Averaging Oxygen Analyzer

Oxygen Dialflow Meter. Instructions for Use

DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Point and Nonpoint Source Management. Design Standards for Sequencing Batch Reactors

Oxygen Measurement Systems High Reliability and Wide Application Coverage

EtO Micro-Dose Sterilization

Profile LFR-43 HELENA ITALY. Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone, Italy

THE WAY THE VENTURI AND ORIFICES WORK

Sapag Control valve MONOVAR

Glove Box Installation Manual

Spirax Compact FREME Flash Recovery Energy Management Equipment

SEMEM4-40 Carrying out the testing and calibration of instrumentation control equipment and circuits

Transcription:

A TYPICAL AERATION UPGRADE CONSIDERATIONS AND OUTCOMES Paper Presented by: Michael Young Author: Michael Young, Director, Faraga Pty Ltd and Aer-Force Pty Ltd 6 th Annual WIOA NSW Water Industry Engineers & Operators Conference Tamworth Regional Entertainment & Conference Centre, 27 to 29 March, 2012 6 th Annual WIOA NSW Water Industry Engineers & Operators Conference Page No. 38

A TYPICAL AERATION UPGRADE CONSIDERATIONS AND OUTCOMES Michael Young, Director, Faraga Pty Ltd and Aer-Force Pty. Ltd. ABSTRACT Most modern sewage treatment involves aeration in an activated sludge process. A typical activated sludge process plant may consume between 50 and 60% of the total power consumed by the complete treatment process.¹ This paper reviews steps taken, in a typical upgrade of a medium sized plant, to replace diffusers, optimize the aeration controls and to minimise power consumption. 1.0 INTRODUCTION The plant considered in this investigation is Hunter Water Corporation s Edgeworth WWTW at Edgeworth near Newcastle. This plant is a Modified Ludzack- Ettinger (MLE) design of continuous activated sludge process and was designed for an EP of 70,000. It currently treats approximately 14 ML per day². In 1996 the plant was fitted with fine bubble porous diffusers fixed to the floor on a grid of upvc pipework, the diffusers were renewed in 2005. An aeration upgrade was carried out in 2009/10 on which the author has based this paper. 2.0 DISCUSSION 2.1 Aeration Review The 2009 upgrade of the Edgeworth WWTW involved a complete review of the aeration process and included: Replacing the porous diffusers with larger membrane diffusers better able to withstand interruptions to the air supply. Providing additional aeration capacity for future load increases. Providing greater tapered aeration to optimise the anoxic zone effectiveness Upgrading the existing blower system. Providing motorised control valves on the air supply pipework to the tanks. Providing new instrumentation for greater and more reliable control. Modifying the control system to allow multiple modes of aeration control in the event of failures. Providing facilities to monitor and maintain the diffusers. 2.2 Upgrade Requirements At Edgeworth WWTW there are 2 aeration tanks, each of which is 45.1m long by 24.0m wide with a maximum liquid depth of 5.0m. Within the tanks there is an anoxic zone which is separated from the aeration zone by a fully submerged stub wall 2m high with a 4 m wide gap on the side opposite the MLR pipework. The MLR flows from the outlet end to penetrate the stub wall at the anoxic zone and is formed from 1.5m wide upturned culvert sections being laid on the tank floor adjacent to the tank wall after the tank had been constructed. 6 th Annual WIOA NSW Water Industry Engineers & Operators Conference Page No. 39

In the years prior to the latest upgrade the existing aeration diffusers had gradually become fouled due to periodic blower outages and inability to carry out on- line periodic maintenance. The classic increase in backpressure shows on the following trend chart. Refer figure 1 Figure 1: Increase in system backpressure Process requirements were considered and the parameters for the upgrade were determined as shown in Table 1 below. Table 1: Plant design requirements PEAK SOTR Present 750 kgo 2 /hr 2030 Future 1,040 kgo 2 /hr PEAK AIRFLOW Present 11,000 m 3 /hr 2030 Future 12,690 m 3 /hr In order to make the de-nitrification more efficient the existing graded aeration was to be changed as shown below in Table 2. Table 2: Grading of oxygen in the tanks % OF TOTAL OXYGEN / TANK DELIVERED TO EACH ZONE Existing Proposed ZONE 1 40% 50% ZONE 2 32% 33% ZONE 3 28% 17% 2.3 Other issues to be considered The existing blowers were not only aging but of differing types which, when operating together, made controls a problem. Due to the need to replace the fouled and aged diffusers, and in recognition of the power outages encountered at the plant it was decided to change the diffusers from porous discs to membranes with greater surface area, and capable of fitting on to the existing bodies and pipework. 6 th Annual WIOA NSW Water Industry Engineers & Operators Conference Page No. 40

This presented a challenge, as the greater kgo2/hr could be achieved by replacing the existing 210mm diffusers with 300mm diffusers but this would generate too great an oxygen transfer with too little taper. Diffusers were required to be blanked off in zones 2 and 3. The DO levels in each of the tanks varied considerably, in some cases by more than 30%. This was a critical issue as the plant is required to operate at an unusually low level of DO of 0.5mg/ L. Over the past the operators have changed the air flows to each tank by adjusting a manual butterfly valve in the header, effectively using an isolation valve as a flow control valve. 2.4 Solutions Adopted The blowers chosen were the latest generation of centrifugal high speed turbines driven through VF drives at very high motor speeds, and the benefits of small footprint, low noise level and air bearings resulted in high efficiency and low maintenance. Main digital operating functions, such as Ready, Run, Alarm, Fault, and Power were hardwired to the PLC. The analogue set value (current in this case) was also hard wired. The blower local PLC was connected via optic fibre to the main PLC, thus giving total visibility to the plant of all the conditions within the blower. The DO probes chosen were the latest galvanic type oxygen cells with the oxygen analyzer designed for continuous monitoring. The probes were automatically cleaned every 24 hours by water jet. Each tank now has 4 DO probes, one in the anoxic zone and 3 in the aerobic zone, 1 in each of the aerated zones. Flow meters, to check the air flow to each of the tanks, were chosen as thermal mass flow meters. Pressure and temperature measurement are built in to each of the blowers The existing manually actuated full bore isolating valves were maintained and actuators were added. Although being full bore and not ideal for modulating flow control, it was determined that these valves would be suitable for trimming control. Power would be saved by not changing to smaller bore valves with better control characteristics, as this would have involved a greater system back pressure. The actuators were set to trim to an algorithm every 10 minutes with a maximum of 2% change each movement. As tank 2 showed greater DO, tank 1 valve was maintained at 100%. Tank 2 valve modulated in accordance with figure 2 shown below. 6 th Annual WIOA NSW Water Industry Engineers & Operators Conference Page No. 41

Figure 2: Tank 2 control valve position. The diffusers were changed from 215 dia sintered polyethylene porous diffusers to 300 dia EPDM rubber membrane diffusers, from the Nopon range of products. Downtime in the tanks was restricted to 1 week for draining, cleaning, and replacing the diffusers, with work not to be carried out in the peak summer months. Three different control modes were finally adopted for the control of the aeration system. Mode 1. The 6 DO meters from the aerobic zones of the tanks are averaged and the resulting value is used to increase or decrease the blower output accordingly. The average of the 3 DO meters in each tank is also used to adjust the flow and therefore the DO between the 2 tanks by trimming the main header isolating valve. The DO readings are taken every 10 minutes and the valve position changes, operate in 2% increments. Mode 2 This mode is adopted if none of the DO meters are operating or are unavailable. The plant influent data is used to compute the required total airflow required. An algorithm sets the blowers to provide the required airflow. Mode 3. This mode is adopted if none of the DO meters are operating and if one or more of the flow meters is not operating or available. The PLC will review the histogram of tabulated output settings from the previous 24hrs of operation, and set the blowers accordingly. Blowers change over after 7 days. Where one blower operates at 95% then the second blower comes on to assist, they then both ramp up from a 45% speed. Resultant average DO in each tank is shown in figure 3 below. 6 th Annual WIOA NSW Water Industry Engineers & Operators Conference Page No. 42

Figure 3: Average DO in tank 1 Diffusers, being EPDM membrane type, have had their droppers modified to include for in-line monitoring. The sockets added allow for pressure and flow monitoring as well as a dosing point for formic acid. See figure 4 below. Figure 4: Diffuser maintenance fittings The air pipe offtakes shown are the anubar flow meter offtake before the valve, followed by the offtake with valve and plastic tubing for line pressure. This plastic tubing terminates in the gang plate, as shown, where direct dp measurements can be taken for pressure drop across the diffusers. The nozzle furthest out near the dropper bend into the tank is the injection point for formic acid. 6 th Annual WIOA NSW Water Industry Engineers & Operators Conference Page No. 43

3.0 CONCLUSIONS Aeration capacity has been increased by 38%. The aeration control system is more flexible, reliable and has been simplified. The air distribution between the two tanks is now automatically controlled. The diffusers are now more able to withstand air outages without adverse consequences. The diffusers are able to be regularly monitored and maintained without taking offline, thus prolonging their effective service life. The latest generation of blowers are effectively maintenance free. NH3 and BOD7 levels have continued to meet plant requirements. Aeration efficiency has increased by approximately 45%. Before the upgrade peak load involved 2 x 90 kw blowers operating at 90%. After the upgrade one blower is almost coping with 90kW. EDGEWORTH WWTW POWER USE 700 600 kwh/ml flow/month 500 400 300 200 100 0 May-05 Oct-06 Feb-08 Jul-09 Nov-10 Apr-12 Months Figure 5: Plant power consumption 4.0 ACKNOWLEDGEM ENTS Abergeldie Young Process Engineering Pty. Ltd., Aeration Upgrade Contractor Dao Norath, Tom Cordingly Hunter Water Corporation. John Stevens Hunter Water Australia, Tom Lawson Aer-Force diffuser replacement maintenance and supply. 5.0 REFERENCES 1. Wastewater Engineering by Metcalf and Eddy 2003 edition chapter 15 p 1704. 2. Hunter Water Website and existing plant SCADA data. 6 th Annual WIOA NSW Water Industry Engineers & Operators Conference Page No. 44