GE Measurement & Control

Similar documents
Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

Owner s Manual Humiport 10/20

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

SPECIFICATIONS APCEPH1

Advanced Test Equipment Rentals ATEC (2832)

RAM 4021 Operation Manual

LM6 LEATHER MOISTURE METER

PM105 PRESSURE METER USER S MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL

RAM 4021-DPX Operation Manual

Getting to know your Sureshotgps micro V3

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

OPERATING INSTRUCTIONS V 5.3

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

SMART Oxygen Analyzer. User Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Digital Vacuum Regulator

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Handi+ OPERATING MANUAL & INSTRUCTIONS FOR USE. R218P15 Industrial. R218M15 Rev. D

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Table of Content 1 Introduction... 1

92831 TEL: (714) FAX:

RAM Operation Manual

Controller for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW User guide

QUICK START GUIDE Kestrel 5500 Weather Meter

Ambient Weather WS-03 Thermo-Hygrometer

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Heavy Duty Dissolved Oxygen Meter

M104 Series: Digital Manometer: 0.1 % of Full Scale

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

Arena by Oregon Scientific

Lifeloc FC10. Operations Manual. Unlock the Power of Alcohol Testing

User s Guide Temperature Sensor Converter TSC-599

HI 2314 HI 2315 HI 23151

HiVolCal User Manual High Volume Field Calibrator Model HVC1 (7 to 54 CFM) NIST Traceable ISO 9001:2008

AED Trainer NF1200-T. Operator s Manual

High Performance Electronic Components 1411 S. Roselle Rd Schaumburg, IL Fax

GasLab SAN-102 Micro Oxygen Monitor User Manual

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Instruction Manual. Model DSP-Ex Portable Dewpoint Meter. Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL EM Washington Street Melrose, MA Phone Toll Free

Fingertip Pulse Oximeter

The Univentor 1250 Anaesthesia Unit

6 digital caliper with case

Dual-gas Oxygen and Carbon Monoxide SMART Analyzer User Manual

USER GUIDE 1000, 2000, 2500 & 2500NV, 3000, 3500 & 3500NV, 3500DT.

SPS-5. Rate Computing Scale. Operation Manual

NKhome.com

GasLab SAN-102 Micro Oxygen Monitor User Manual

USER'S GUIDE. Vaisala Structural Humidity Measurement Kit SHM40 M211423EN-C

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

EM151/EM201. Electronic Manometer - + INSTRUCTION MANUAL. EM201 PSI

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

OWNER S MANUAL. AXD 530 MicroManometer

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

Manufactured by: AAA

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

COMBAT SWIM BOARD. RJE International, Inc. TAC-300 Revision C. RJE International August 3, TAC-300 Revision C

PTG100 Precision Test Gauge

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Relative Humidity Calibration Kit

DTG - LCD Digital Temperature Gauge USER MANUAL

Model Series 63DL Differential Type Flow Controller

Golf Performance Monitors. PureContact Operating Guide. Version of 9

AA100 Acoustic Actuator

Pocket Air FlowTracker

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

4000 Series Pocket Weather Trackers Instruction Manual

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

SDM-2012 Docking Station Standalone Configuration Operator s Manual

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

ENVIRONMENTAL INSTRUMENTS, LLC

INSTALLATION MANUAL Residential and Small Commercial Applications

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

SMART Carbon Monoxide Analyzer. User Manual

Model 4140/4143 General Purpose Thermal Mass Flowmeter

WELCOME TO THE REVOLUTION

-VERITAS- High Volume Field Audit Calibrator Dual Range Model HVC2 1.4 to 7 and 7 to 54 CFM. NIST Traceable ISO 9001:2008

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Using the UltraRAE. Firmware 2.35

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Operating Instructions Part No

PPS PORTABLE POWER SUPPLY

ATEX ATEX

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Rev. 1. Cryogenics Thermoflasks. 2122, 2123, 2124, 2129, and 2130

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

Robic M-477 Instructions and Operating Guide

Norrsken Family Booklet

ANALOX ATA - Trimix Analyser. Technical Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Transcription:

GE Measurement & Control Psyclone Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. C August 2013 Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses under a new name GE Measurement & Control. Psyclone is a registered trademark of GE Measurement & Control.

Introduction The GE Protimeter Psyclone thermohygrometer measures relative humidity with psychometric measurements, along with temperature. One button enables Start, Hold and OFF operation, and four arrow keys allow you to set up and change the measurements shown on the LCD screen. An optional surface temperature probe enables users to determine if condensation is present. Figure 1 below shows the Psyclone control buttons, while Table 1 on the next page lists the available parameters. On/Hold/Off Hold for 2 sec to enter Setup Figure 1: The Psyclone (#BLD7800) Control Buttons Protimeter Psyclone Page 1

Table 1: Psyclone Measurement Parameters Parameter Symbol % Relative Humidity % RH 1 Grains per pound GPP 2 Grams per kilo Gram Dewpoint Temperature Wet Bulb Temperature 2 Kilo Calorie per Kilogram g/kg DEW POINT WET BULB kcal/kg 1 British Thermal BTU/lb Units per Pound Ambient Temperature AMBIENT Surface Temperature SURFACE Proximity to Dew TEMP DIFF Point at the Surface 1 Displayed if F units chosen in Setup 2 Displayed if C units chosen in Setup Page 2 Protimeter Psyclone

Starting the Psyclone for the First Time The Psyclone comes with two AA, 1.5V batteries already installed. To begin using the meter, extend the retractable probe and press the (ON) button. The LCD screen briefly flashes, similar to Figure 2 below. After a few seconds, the meter changes to measurement mode and displays only the currently selected parameters, as shown in Figure 3 on the next page. Moisture readings appear at the top, with temperature measurements below. Figure 2: Full Screen Display Protimeter Psyclone Page 3

Starting the Psyclone for the First Time (cont.) Figure 3: Typical Screen Display During Operation To freeze the Psyclone at a particular reading, press the button briefly. The Hold message appears to the left of the temperature reading, as shown in Figure 2 on the previous page. To shut off the Psyclone, press the button for 3 seconds, until the message OFF appears before the LCD goes blank. Page 4 Protimeter Psyclone

Selecting Parameters and Calculations Use the four arrow keys to select the parameters and calculations you want to display. Press any of the arrow keys to scroll to the parameter row (shown in Figure 2 on page 3); then press the RIGHT arrow key to scroll to the parameter or calculation. The reading changes immediately, and the parameter is set once the flashing stops. Pressing instantly selects the parameter. To select the humidity parameter (%RH, GPP, g/kg, or Dew Point): Scroll to the top row, and then to the desired parameter. Note: If you have selected the Psychometric Calculation On option, your options include the available calculations. Protimeter Psyclone Page 5

Selecting Parameters and Calculation (cont.) To select a calculation (Minimum, Maximum or Average): Scroll to the middle row, and then press the RIGHT or LEFT arrow key to select the desired calculation. The min/max/ave calculations are made from the last time the meter was powered up. If no parameter is selected, all the parameters in that row remain solid (not blinking), and the Psyclone displays the current reading. Min/ Max/Ave will continue to calculate while in these modes. Push the UP arrow to return to free measurement mode. Page 6 Protimeter Psyclone

Setting User Options To set up the user options to your particular requirements, firmly press and hold the SETUP key (the DOWN arrow key) for 2 seconds. The lower part of the screen appears similar to Figure 4 below. Figure 4: Setup Menu The factory default settings are: Temp - Off Psy. Cal. Options - Off Device auto off - 3 mins Back Light - 0 mins (off) Use the LEFT and RIGHT arrow keys to scroll to the desired option, and the UP and DOWN arrow keys to set the desired selection. Once selected, wait for the meter to return to measurement mode or push the button to save the change. Four options are available: Protimeter Psyclone Page 7

Setting User Options (cont.) Units F/ C You can display all temperature measurements in either F or C. (Setting C also results in displaying other parameters in metric units, such as g/kg. Setting F prompts the meter to display other parameters in nonmetric units, such as GPP or grains per pound.) Press the UP or DOWN arrow key to toggle between F and C units. Psychometric Calculations You can extend the available humidity measurements to include psychometric calculations (Wet Bulb Temperature, kcal/kg and BTU/lb, shown in Figure 2 on page 3). Press the DOWN or UP arrow key to turn ON (or OFF) the Psychometric Calculation options. When the screen refreshes, you can then select the desired calculation (see the next page). Page 8 Protimeter Psyclone

Setting User Options (cont.) Backlight You can set the backlight for the LCD display to remain on from 1 to 9 minutes at a time. (If you set the time to 0, the backlight is turned off.) Use the UP and DOWN arrow keys to scroll to the desired number of minutes after the last button push. Device Auto OFF You can set the Psyclone to shut off automatically after from 1 to 9 minutes. (If you set the time to 0, the automatic shutoff is turned off.) Use the UP and DOWN arrow keys to scroll to the desired number of minutes to stay on after the last button push. Protimeter Psyclone Page 9

Using the Optional Surface Temperature Probe (#BLD5808) Note: The Surface Temperature (Surface) and Temperature Difference (Temp Diff) appear only if you are using the surface temperature probe option. To obtain surface temperatures via the optional probe: 1. Plug in the surface temperature probe on the right side of the Psyclone. 2. Scroll to the bottom row using the UP or DOWN arrow keys, and then select Surface or Temp Diff on the screen. Selecting Ambient uses the Psyclone s internal sensors. 3. Remove the black cap, exposing the metal sensing strip on the sensor. 4. Apply the metal strip on the probe to the surface you wish to measure. Page 10 Protimeter Psyclone

Using the Optional Surface Temperature Probe (cont.) In Surface mode, the reading shown will be the surface temperature. (Allow time for the reading to settle.) In Temp Diff mode, the temperature shown will be the proximity to Dew Point (when condensation will occur). For example, a reading of 5 degrees would indicate that the surface temperature is 5 degrees above the Dew Point. A reading of -5 degrees would indicate that the surface temperature is 5 degrees below the Dew Point and condensation is present. Figure 5: Optional Surface Temperature Probe with Cap Removed Protimeter Psyclone Page 11

Caring for Your Psyclone When you have finished using the Psyclone, retract the probe back into the meter. Use the carrying case to protect the Psyclone when not in use. Keep the Psyclone out of water, and away from dirt and dust. If the Psyclone has been stored in excessive heat or cold (i.e., a vehicle), allow for increased acclimation time. A low battery warning appears when the battery has only 20% of its charge. To replace the batteries, remove the panel on the rear of the Psyclone and insert two 1.5V, AA batteries. Do not use rechargeable batteries. Error Codes E-1: Sensor probe not responding E-2: CRC checksum error If either of these codes appears, contact GE Sensing. Page 12 Protimeter Psyclone

Replacement Parts To order the parts listed below, or for additional service, contact GE Measurement & Control at 800-833- 9438 (North America) or +353 61 470200 (Europe and Asia) or www.ge-mcs.com. Battery Cover (BAT7800) Pouch (POU8512) Belt Clip (BLD7810) Specifications Power 2 x AA 1.5v Enclosure Material Dimensions PC with silicone rubber boot ~165 mm x ~65 mm x ~30 mm (~6.5 in. x ~2.5 in. x ~1.2 in.) ~ 200 g Weight Front Panel Keys Rubber function keys Probe Humidity Measurement Range Humidity Precision 1.0-99.0% (non condensing) ± 2% (10% to 90% @ 25 C/77 F) Protimeter Psyclone Page 13

Specifications (cont.) Operating Temperature Range Probe Measurement Temperature Range in Duct Temperature Accuracy Certifications 0 to 50 C (32 to 122 F) -20 to 85 C (-4 to 185 F) ± 0.5 C (0 to 50 C/ 32 to 122 F) CE Approval, RoHS Compliance & WEEE Emissions: Class A Immunity - Annex C. Performance Criteria - Non Continuous Operation. Page 14 Protimeter Psyclone

Glossary Symbol Definition % RH The ratio of the amount of water vapor in the air at a specific temperature to the maximum amount that the air could hold at that temperature, expressed as a percentage Specific Humidity (GPP, g/kg and PPMw) DEW POINT ( C/ F) The ratio of the mass of water vapor to the mass of dry air. For very low levels, the Specific Humidity is also expressed as parts per million by weight (PPMw). The temperature at which the air you are measuring would be saturated. Condensation would begin to appear on surfaces that are colder that the dew point temperature. Protimeter Psyclone Page 15

Glossary (cont.) Symbol WET BULB ( C/ F) Enthalpy (kcal/kg) Enthalpy (BTU/lb) Definition The temperature of a wetted thermometer in moving air. The wet bulb temperature is a measure of the rate of evaporation, which is influenced by the amount of water vapor in the air. The amount of thermal energy required to remove all the water from 1 kg of air and cool it to 0 C. The amount of thermal energy required to remove all the water from 1 lb of air and cool it to 32 F. Page 16 Protimeter Psyclone

Limited Warranty GE Sensing (GE) warrants the Psyclone thermo-hygrometer (Psyclone) against defects in material and workmanship for 24 months from the date of shipment. Materials or workmanship faults in the humidity and temperature probe assembly are covered for 12 months from the date of shipment. Products not subjected to misuse will be repaired or replaced. GE reserves the right to make changes without further notice to any products herein. GE makes no warranty, representation or guarantee regarding the suitability of its products for any particular application nor does GE assume any liability arising out of the application or use of any product or circuit and specifically disclaims all liability without limitation for consequential or incidental damages. The foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. GE Sensing standard terms and conditions apply. Protimeter Psyclone Page 17

Return Policy If a GE Sensing, Inc. instrument malfunctions within the warranty period, the following procedure must be completed: 1. Notify GE Sensing, Inc., giving full details of the problem, and provide the model number and serial number of the instrument. If the nature of the problem indicates the need for factory service, GE Sensing, Inc. will issue a RETURN AUTHORIZATION NUMBER (RAN), and shipping instructions for the return of the instrument to a service center will be provided. 2. If GE Sensing, Inc. instructs you to send your instrument to a service center, it must be shipped prepaid to the authorized repair station indicated in the shipping instructions. 3. Upon receipt, GE Sensing, Inc. will evaluate the instrument to determine the cause of the malfunction. Page 18 Protimeter Psyclone

Return Policy (cont.) Then, one of the following courses of action will then be taken: If the damage is covered under the terms of the warranty, the instrument will be repaired at no cost to the owner and returned. If GE Sensing, Inc. determines that the damage is not covered under the terms of the warranty, or if the warranty has expired, an estimate for the cost of the repairs at standard rates will be provided. Upon receipt of the owner s approval to proceed, the instrument will be repaired and returned. Protimeter Psyclone Page 19

USA 1100 Technology Park Drive Billerica, MA 01821-4111 Tel: 1-800-833-9438 Web: www.ge-mcs.com/en/moistureand-humidity/moisture-meters/ psyclone.html Ireland Sensing House Shannon Free Zone East Shannon, Co. Clare Tel: +353 61 470200