Dual 280C Onboard Air System (Black on Silver) Dual 380C Onboard Air System (Chrome) Dual 380C Onboard Air System (Stealth Black)

Similar documents
ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

400C & 450C DUAL PERFORMANCE VALUE PACKS

444C DUAL PERFORMANCE VALUE PACK

200 PSI COMPRESSORS - MODEL NUMBERS

DUAL 444C ONBOARD AIR SYSTEM

IMPORTANT SAFETY INSTRUCTIONS

100C Air Compressor Kit

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

480C DUAL PERFORMANCE VALUE PACK

200 PSI FAST-FILL AIR SOURCE KIT

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

200 PSI HIGH-FLOW AIR SOURCE KIT

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

IMPORTANT SAFETY INSTRUCTIONS

Model PSI Compressor with 3-Gallon Air Tank 12VDC

REDUCER REDUCER REDUCER

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: P PORTABLE COMPRESSOR

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

HORNBARGAINS. Bandit 400 Instruction Manual

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

OPERATOR S MANUAL 1.5 HP/6-GALLON 6 GAL AIR COMPRESSOR IMPORTANT: READ OPERATOR S MANUAL BEFORE USING. Toll Free Helpline:

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Marschalk Model # 94000

Installation Instructions Air Compressor Part # 2780, 2781

accidents which arise due to non-observance of these instructions and the safety information herein.

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Budget Range Operators Handbook

Freedom8 ShoeBox Compressor Manual

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

Kit Details Air Lift Performance HARDWARE LIST STOP!

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

2 Gallon Air Compressor

Pressure Dump Valve Service Kit for Series 3000 Units

Lubricated TC Models

G7S Hand Pump Owner s Manual

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

General Safety. All electrical work

AMS SUPER SILENT COMPRESSOR USER & MAINTENANCE GUIDE

AIR INLINE METAL SHEAR

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Portable Oil Lube Air Compressors

SILENTAIRE TECHNOLOGY

2 Gallon, 100 PSI Oilless

DeVILBISS AIR POWER COMPANY. OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR (For Home Use Only) MODEL NO. DFAC153 SPECIFICATION CHART

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

PC1131 Electric Air Compressor

Universal Valve Company Inc

COMPRESSOR MANUAL. (888)

R E D I C O N T R O L S

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Universal Valve Company Inc

FACTORY SERVICED 8 Gallon Air Compressor. Model: Important Safety Instructions RISK OF EXPLOSION OR FIRE:

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Pressure Dump Valve Service Kit for Series 2300 Units

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

User Instruction Manual

INTENDED USE TECHNICAL SPECIFICATIONS

8-gallon Air Compressor. Owner s Manual

Code AWC20HP Air Compressor

AA-75CF Portable Air Compressor NSN:

CSA Sample Draw Aspirator Adapter Operator s Manual

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

Instruction manual. Pancake Compressor ESPAÑOL: PÁGINA 19 FRANÇAISE: PAGE 37 MODEL CPF23400P

HEAVY-DUTY AIR RATCHET WRENCH OWNER S MANUAL

Note: You will need a full tank of CO2 for connection and leak testing! Kit Number

4WD ACCESSORIES BONUS CARRY BAG 100L AIR COMPRESSOR INSTRUCTION MANUAL

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

2 Gallon Oil Free Air Compressor

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

CUT OFF TOOL MODEL: CAT113

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

VERTICAL AIR COMPRESSORS

Operator: Save these instructions for future use!

1 DRIVE INDUSTRIAL IMPACT WRENCH

PC 1010 Electric Air Compressor

Transcription:

20011 - Dual 280C Onboard Air System (Black on Silver) 20013 Dual 380C Onboard Air System (Chrome) 20014 Dual 380C Onboard Air System (Stealth Black) 20015 Dual 400C Onboard Air System (Chrome) 20016 Dual 400C Onboard Air System (Stealth Black) 20017 Dual 450C Onboard Air System (Chrome) 20019 Dual 444C Onboard Air System (Chrome) 20020 Dual 444C Onboard Air System (Stealth Black) *PARTS INCLUDED IN THE PRODUCT PHOTO MAY VARY. IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL FOR FUTURE REFERENCE

REDUCER Thank you for purchasing this complete, self-contained onboard air system. Contained in one package, you ll find everything you ll need to install a high performance, onboard air source for your vehicle. Please follow these instructions to install your new system. OBA Components: DUAL ONBOARD AIR SYSTEM (P/N 20011) 1-2.5 Gallon, 6 port VIAIR Air Tank (Max. 150 PSI), 2-280C Black on Silver VIAIR compressors (P/N 20013) 1-2.5 Gallon, 6 port VIAIR Air Tank (Max. 200 PSI), 2-380C Pewter VIAIR compressors (P/N 20014) 1-2.5 Gallon, 6 port VIAIR Air Tank (Max. 200 PSI), 2-380C Stealth Black VIAIR compressors (P/N 20015) 1-2.0 Gallon, 6 port VIAIR Air Tank (Max. 150 PSI), 2-400C Chrome VIAIR compressors (P/N 20016) 1-2.0 Gallon, 6 port VIAIR Air Tank (Max. 150 PSI), 2-400C Stealth Black VIAIR compressors (P/N 20017) 1-2.5 Gallon, 6 port VIAIR Air Tank (Max. 150 PSI), 2-450C Silver VIAIR compressors (P/N 20019) 1-2.5 Gallon, 6 port VIAIR Air Tank (Max. 200 PSI), 2-444C Chrome VIAIR compressors (P/N 20020) 1-2.5 Gallon, 6 port VIAIR Air Tank (Max. 200 PSI), 2-444C Stealth Black VIAIR compressors Air Tank Installation: PARTS PACKAGES Compressor Installation: A B C D E F M N O P Q R1 R2 G H I J REDUCER S T U1, U2 K L A. Mounting Bolts (4pcs) B. Flat Washers (4pcs) C. Locking Washers (4pcs) D. Nuts (4pcs) E. Rubber Tank Mount Bushings (6pcs) F. 1/4 NPT Drain Cock (1pc) G. 1/4 NPT 175 PSI Safety Valve (1pc) * P/N 20011, 20015, 20016 & 20017 only 1/4 NPT 250 PSI Safety Valve (1pc) * P/N 20013, 20014, 20019 & 20020 only H. 1/4 NPT Compression Fittings (4pcs) I. 1/4 NPT M Quick Connect Coupler (1pc) J. 6-Port Manifold & Bracket (1pc) K. 1/4 M x 1/8 F Reducer (1pc) * P/N 20013 & 20019 only L. 1/4 NPT M Plugs (5pcs) Gauge Panel Installation: REDUCER DD EE FF GG HH II REDUCER X W M. Mounting Bolts (8pcs) N. Flat Washers (16pcs) O. Locking Washers (8pcs) P. Nuts (8pcs) Q. Remote Mount Air Filter Assemblies (2pcs) R1. 1/4 NPT F x 3/8 Barbed Fitting (2pcs) R2. 1/4 NPT M x 3/8 Barbed Fitting (2pcs) S. 2-pack of Replacement Air Filters (2pcs) T. Leader Hose Bracket Clips (2pcs) U1. 3/8 O.D. Air lines (2pcs) U2. 1/4 O.D. Air lines (2pcs) V. 60-amp Tube Style Fuse Holder (1pc) * Fuse not included. W. Screws (6pcs) X. Air Line Clips (6pcs) V JJ KK LL DD. Dash Panel Gauge with ON/OFF Switch (1pc) EE. Mounting Bolts (2pcs) FF. Flat Washers (4pcs) GG. Locking Washers (2pcs) HH. Nuts (2pcs) II. Push-on Female Terminals (2pcs) JJ. 12-gauge Ring Terminal (1pc) KK. 12-gauge Butt Connector (1pc) LL. Self-tapping Screw (1pc)

REDUCER Coil Hose with Couplers: AA REDUCER Coil Hose PARTS PACKAGES (CONT D) AA. 30-ft. Coil Hose with close ended Quick Connect Coupler Accessories: BB CC DD EE Compression Fitting BB. 1/8 BSP F to 1/4 NPT M Adaptors (for air locker use) (2pcs) CC. T-Fitting (1/4 M x 1/4 F x 1/4 F NPT (1pc) DD. 1/4 M NPT Plug (for regulator port block-off) (1pc) EE. 1/4 NPT M Compressor Fitting for 1/4 Air Line (1pc) FF. 0-220 PSI Air Pressure Regulator (1pc) FF BSP Adaptors To Air Lockers 2.0 allon ank DUAL ONBOARD AIR SYSTEM Drain Cock Leader Hose From Compressor #2 Pressure Switch & Relays: Y 30 Pressure Z Switch Y. Sealed Pressure Switch (110 PSI on, 145 PSI off) (1pc) * for P/Ns 20011, 20015, 20016 & 20017 only Sealed Pressure Switch (165 PSI on, 200 PSI off) (1pc) Leader Hose From Compressor #1 * for P/Ns 20013, 20014, 20019 & 20020 only Z. 40-amp Relays (2pcs) Air Tools / Carry Bag: GG 86 85 87 To Ground GG. Inflation Gun with 0-200 PSI Pressure Gauge with 1/4 NPT Quick Connect Stud (1pc) P/N 10008, 10009 PLUMBING DIAGRAM m Configuration, May Vary Depending on Installation

10 5 0 15 0 1 20 2 25 30 35 DUAL ONBOARD AIR SYSTEM AIR TANK & PLUMBING The tank comes with six 1/4 NPT port openings to allow installation in many configurations on your vehicle. To ensure safe and trouble-free use of your air tank, we strongly recommend that you install the supplied drain cock and a safety pressure relief valve. (See Figure 1) Plumbing Diagram: (Figure 1) Pressure Switch Safety Valve Leader Hose From Compressor #1 Tank Leader Hose From Compressor #2 Drain Cock Open Ports Quick Connect Coupler Coil Hose Compression Fitting **Wiring Harness NOT included Tank Fittings: Install the supplied fittings for the air tank in areas where they are most appropriate for your installation using thread sealant. (Not all installations will be plumbed exactly as shown in schematic.) Make sure that the safety valve is installed in the top most position on the tank, and that the drain cock is installed in the lowest position on the tank if the tank is to be installed in any other position than upright on the tank s mounting legs. Be sure that all fittings are accessible later in the installation process since you will have to plumb air lines to each fitting as needed to utilize the air tank.

AIR TANK & PLUMBING (CONT D) Mounting the Tank: We have included 6 pieces of rubber bushings in your tank mounting hardware. You have the option of using two layers of rubber bushings on one of your tank legs to slightly tilt tank toward the drain cock port to improve drainage properties. Use the provided longer bolts, and corresponding washers, lock washers and nuts to mount the tank to a suitable chassis or other place on your vehicle. IMPORTANT: - Tank is rated for 150 PSI maximum working pressure. (for P/Ns 20011, 20015, 20016 & 20017 only) - Tank is rated for 200 PSI maximum working pressure. (for P/Ns 20013, 20014, 20019 & 20020 only) - Tank is NOT to be used as a breathing device. - Use only attachments or tools rated for 150 PSI working pressure or less. (for P/Ns 20011, 20014, 20015, 20016 & 20017 only) - Use only attachments or tools rated for 200 PSI working pressure or less. (for P/Ns 20013, 20014, 20019 & 20020 only) CAUTION! DO NOT PRESSURIZE YOUR TANK UNTIL YOU HAVE INSTALLED ALL NECESSARY PORT FITTINGS AND ACCESSORIES. - Apply sealant to threads of fittings prior to assembly and tighten each part with a wrench. - Do not over tighten if your port fittings are made from brass, since brass threads can be stripped. - Bleed pressure from tank before servicing or adding attachments. WARNING: FAILURE TO DRAIN TANK AND REMOVE CONDENSATION WILL CAUSE TANK TO RUST PREMATURELY. - To remove accumulated condensation inside the tank, bleed pressure from tank until pressure is approximately 5-20 PSI using drain cock. - Drain tank by opening the drain cock drain valve and close after draining tank. - If drain cock valve is plugged, release all air pressure from tank, remove drain valve and clean, then reinstall. IMPORTANT: Please observe air tank s Date of Manufacture (stamped on tank leg). Replace air tank 2 to 5 years from date air tank was first used, or use the date of manufacture as reference. Adhering to air tank draining guidelines will prolong the life of your air tank. PLEASE NOTE: RUSTED TANKS CAN FAIL CAUSING EXPLOSIONS OR FATAL INJURIES. Discard tank immediately if tank is rusted. SAFETY VALVE: When using a safety pressure relief valve, point the safety pressure relief valve away from your body when releasing air. Use the pull ring on the safety relief valve to vent pressure from the tank before servicing. DUAL AIR COMPRESSOR INSTALLATION Please follow these installation instructions to enjoy the best use of your onboard air system. CAUTION - To reduce risk of electrical shock or electrocution: - Do not disassemble the compressor. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs. - Do not use this product in an area where it can fall or be pulled into water or liquids. - Do not reach for this product if it has fallen into liquid. - Use this compressor with 12-volt DC systems only. - This product should never be left unattended during use.

DUAL AIR COMPRESSOR INSTALLATION (CONT D) Guidelines for Selecting Mounting Location: The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service life. Please pay close attention to the following: - Select a FLAT, UPRIGHT & SECURE LOCATION where the compressor can be mounted. - To maximize air compressor performance, locate compressor as CLOSE TO THE BATTERY as possible so that length of positive lead wire required is at a minimum. - Choose mounting location that is as cool as possible and away from heat sources. - This compressor is moisture & dust resistant, but NOT WATERPROOF or DUSTPROOF. Do not mount compressor in locations where the unit is likely to come in contact with water or excessive dirt. - For compressor with remote filter mounting, select compressor s mounting location where air line can be routed from compressor air inlet to remote inlet air filter. Make sure that the remote inlet air filter is located in a dry location, away from water. - You will also want to select a compressor mounting location where the leader hose bracket can be mounted to secure the leader hose. - If it is necessary to mount the air compressors further from the battery, such as inside your vehicle or in the bed of your pickup, use a minimum 8 AWG positive lead wire for remote installation for each compressor. - Do not mount compressor near areas where flammable liquids are stored. - Use thread sealant for proper fitting installation. Thread tape is not recommended. Properly sealed, recommended torque for 1/4 and 3/8 is 12~15 ft. lbs. Compressor Wiring: (See Figure 3 on back of manual) 1. Disconnect ground cable from vehicle s battery. 2. Temporarily position the air compressor in the location where it will be mounted. 3. Route ground wire to the negative post of the battery or to an appropriate grounding point and cut ground wire to length as needed. 4. Mount the air compressors with the eight sets of 13/64 (5 mm) bolts, nuts, washers, and locking washers provided. Use of thread locker is recommended. 5. NOTE: For Remote Inlet Air Filter Installation, refer to Remote Inlet Air Filter Installation Instructions included in the Remote Inlet Air Filter Pack. 6. This air compressor comes with a heavy duty heat resistant stainless steel braided leader hose with 1/4 NPT fittings. This leader hose is designed to prolong the life of your air line. Do not remove this leader hose from air compressor. 7. IMPORTANT: Please note; the leader hose that came with your compressor has a built-in inline check valve pre-installed. Do not remove inline check valve from leader hose. 8. Select a proper location to mount leader hoses with hose brackets provided. Avoid locations where leader hose may become tangled with wires and other hoses. 9. To mount hose bracket, drill holes with 3/16 drill bit and push self anchoring hose bracket pin into hole. Route leader hose through hose bracket and secure hose by pressing bracket clamp into locked position. 10. To remove hose from the hose bracket, simply press down on the hose clamp release tab to release bracket clamp. 11. Follow wiring diagram on the back of manual (Fig. 3) 12. Make sure that your compressor setup is properly fused. (Fuse not included). Dual 280C compressors pull approximately 33 maximum amps of power. Dual 380C & Dual 450C compressors pull approximately 44 maximum amps of power. Dual 400C compressors pull approximately 60 maximum amps of power. Dual 444C compressors pull approximately 40 maximum amps of power. 13. Always locate fuse as close as possible to power source. 14. Before connecting to power source, check to make sure that all connections are made properly. 15. Connect and test compressor system by running the compressor for a short time to build up pressure in your air tank. 16. Once air pressure reaches preset cut out pressure of your pressure switch, the compressor will shut off. Inspect all air line connections for leaks with soap and water solution. If a leak is detected, the air line may not be cut squarely or pushed all the way in. Tighten connections if needed.

OPERATING INSTRUCTIONS DUAL ONBOARD AIR SYSTEM IMPORTANT: The compressors have a maximum working pressure of 150 PSI (P/Ns 20011, 20015, 20016 & 20017) or 200 PSI (P/Ns 20013, 20014, 20019 & 20020). Always operate the compressor at or below the MAXIMUM PRESSURE RATING of the compressor. Operation exceeding maximum pressure ratings and or duty cycle will result in damage to air compressor. 1. Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR. This feature will protect the air compressor from overheating and causing permanent damage to your air compressor. The thermal overload protector will automatically cut off power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use. 2. Should your air compressor automatically shut off during use, turn power to the system off. The automatic thermal overload protector will automatically reset when internal temperature of the air compressor drops below safe levels. After allowing air compressor to cool off, you can safely resume use of the air compressor by turning on the system. 3. To prevent discharge of your battery and to provide peak performance, it is recommended that you keep the engine running while the air compressor is in use. 4. ONLY OPERATE THE AIR COMPRESSOR IN WELL-VENTILATED AREAS. Dual Compressor Maintenance & Repairs: 1. Periodically check all electrical and fitting connections. Clean and tighten as needed. 2. Periodically check all mounting screws. Tighten as needed. 3. Replace air filter element periodically. Replacement frequency depends on operating frequency and operating environment. For frequent use in dusty environment, you should replace air filter element more often. 4. Regularly clean dust and dirt from compressor. 5. Your air compressor is equipped with permanently lubricated, maintenance-free motor. Never lubricate compressor. 6. Repairs should be performed by Manufacturer or Manufacturer s Authorized Service Agencies only. CAUTION: Never touch the air compressor or fittings connected to the air compressor with bare hands during or immediately after use. Leader hose and fittings will become very HOT during and after use. Dual Compressor Installation Tips: 1. Always use the remote intake filter option when possible. This will extend the service life of your compressor. 2. If noise reduction from vibration is desired, using the remote mount option for the inlet filter can reduce operation noise by up to 25%. 3. Always mount the compressor at a point higher than the inlet port of the tank. This will keep moisture from being able to seep back to the compressor. 4. When mounting the compressor, use a paint pen on the rubber isolators and cover the side to go against the chassis or mounting location. Then, simply stamp the compressor against the chassis to make an imprint of exactly where to drill the mounting holes for the compressor. PRESSURE SWITCH INSTALLATION Your VIAIR Onboard Air System comes complete with a heavy duty sealed pressure switch that will turn on the compressor at 110 PSI, and off at 145 PSI (P/Ns 20011, 20015, 20016 & 20017) or 165 PSI on, and 200 PSI off (P/Ns 20013, 20014, 20019 & 20020). The pressure switch has a 1/8 NPT (P/Ns 20013, 20014, 20019 & 20020) or 1/4 NPT (P/Ns 20011, 20015, 20016 & 20017) inlet and pre-applied thread sealant. Pressure Switch with Relay Installation Tips: 1. Both terminals of the pressure switch are positive (+) leads. (The use of a relay is always recommended). 2. Never use a pressure switch that is rated beyond your compressor s rated Maximum Working Pressure. 3. Replace the Pressure Switch with P/N 90221 (for Dual 380C and Dual 444C), or with P/N 90227 (for Dual 280C, 400C and Dual 450C) if the pressure switch becomes faulty or fails in the future. 4. See Fig. 3 for relay and pressure switch installation tips.

DASH PANEL GAUGE INSTALLATION DUAL ONBOARD AIR SYSTEM Your VIAIR Onboard Air System comes complete with a Dash Panel Gauge to monitor the pressure of your VIAIR air tank. Additionally, the Dash Panel Gauge has an ON/OFF switch preinstalled that will allow you to turn the system off by cutting power to the pressure switch with relay that you have already installed. We recommend that you install a master ON/OFF switch to allow the system to be turned off any time you anticipate leaving the vehicle parked for any length of time, and to avoid draining the vehicle s battery unnecessarily due to a slow air leak in your system. (See Figure 3 on back of manual) IMPORTANT: Each Dash Panel Gauge has been tested and calibrated. The air inlet on this gauge has a factory installed compression fitting. DO NOT attempt to tighten or loosen the body of this compression fitting. Any adjustments will cause the gauge to malfunction and void warranty. The Dash Panel Gauge included in this kit is rated for 150 PSI (PN 20011, 20015, 20016 & 20017) or 200 PSI (PN 20013, 20014, 20019 & 20020). Always operate the gauge at or below the MAXIMUM PRESSURE RATING of the gauge. 1. Select Mounting Location for Dash Panel Gauge: Select a mounting location with a rigid mounting surface such as the bottom edge of the dashboard. Use the gauge mounting panel as a template; mark off two mounting points to be drilled. Carefully drill two 13/64 diameter holes as marked. Do not mount Dash Panel Gauge at this time. 2. Air Line Connection to Dash Panel Gauge: Remove only the collar of the compression fitting from the back of the Dash Panel Gauge. Do not loosen or tighten the body of the compression fitting, which is permanently affixed to the air inlet of the gauge. Insert air line tubing through this collar, and then push air line tubing onto the barb of the compression fitting until the air line completely covers the barb. Tighten collar onto the body of the compression fitting with a wrench. 3. Routing Air Line to Air Source: Route the air line tubing on the Dash Panel Gauge to the air source. Do not cut air line yet. In some cases a hole may need to be drilled to enable the air line to pass through to the air source. Make sure that the air line tubing is protected from any sharp edges of the drilled hole using grommet strip supplied. Connect to the tank using the 1/4 compression fitting supplied. Installation Tips: - When cutting air line tubing, always cut as squarely as possible. Use a hose cutter or razor blade. - When routing air line tubing, always remember to avoid sharp edges, heat sources and tight bends. (Air line must be routed at least 12 inches from exhaust systems & other heat sources.) IMPORTANT - Drilling through firewall: Always be sure of what is on the other side of the firewall before drilling. Take care not to damage your vehicle s electronic systems or components. 4. Wiring the ON/OFF Switch: Attach one of the two remaining female terminal connectors to the wire that was routed from the pressure switch trigger wire (Small Red Wire on pressure switch with relay) There are two male spade connectors on the back of the ON/OFF switch. Connect this female terminal connector to one of the male spade connector on the ON/OFF switch. Next, attach appropriate size ring terminal provided in the kit to the end of the wire with the Inline Fuse. (The ring terminal should be about 12 from the inline fuse.) This wire is referred to as the power wire. Temporarily position the ring terminal at the power source and route power wire to the dash panel gauge, measure and cut to appropriate length. (If additional wire is necessary, use 16 AWG wire.) Attach the remaining female terminal connector to end of power wire, and connect to male spade connector on the ON/OFF switch. (Note: Do not connect gauge to power source at this time.) 5. Wiring the Dash Panel Gauge for Illumination: There are two wires, one red and one black connected to the light bulb of the gauge. Connect the red wire to a suitable fused dash panel circuit. Use the quick splice connector included in the kit for wire connections. The black wire is to be connected to a suitable ground source. 6. Mounting the Dash Panel Gauge: With all electrical and air line tubing routed and connected properly, mount the dash panel gauge using the two 13/64 nuts, bolts, and washers included with the Dash Panel Gauge. Make sure that no electrical wires or air line can be contacted by vehicle pedal operation, or by use of any safety equipment. Use provided zip ties to secure air line and electrical wiring.

DASH PANEL GAUGE INSTALLATION (CONT D) 7. Connect to Power Source: Before connecting the power wire to a power source, check to make sure that the ON/OFF switch on the dash panel gauge is in the OFF position. Connect the ring terminal of the power wire to power source. (This is the wire described in Step 4, which is connected to the ON/OFF switch of the dash panel gauge.) 8. Testing Your Onboard Air System: Your Onboard Air System installation is now complete. Run the compressor to build pressure in the air tank. When air pressure reaches the pressure switch cut out pressure, the compressor will shut off. Inspect all air line connections for leaks with soap and water solution and spray with a spray bottle onto connections to check for leaks. If leaks are detected, air line may not be cut squarely or pushed all the way in. Fix connections as needed. Periodically check your system s fitting in this manner should your compressor turn on more often than normal without frequent air use. INLINE PRESSURE REGULATOR INSTALLATION Your Onboard Air System comes complete with an adjustable inline air pressure regulator that may be used to regulate the pressure in your air tank down to desired pressure. This is especially useful for installations that will supply air to a locking differential, or may be used to operate air tools. Never attempt to use the regulator to adjust any tank pressure over Maximum Pressure Rating of the compressor and other components. 1. Mounting the Inline Pressure Regulator: Select a mounting location with a rigid mounting surface such as the bottom edge of a chassis. Use the inline pressure regulator mounting bracket as a template to mark the two mounting points to be drilled. Carefully drill the two holes as marked, and mount the Pressure Regulator at this time. 2. Air Line Connections to Inline Pressure Regulator: Use a 1/4 NPT compression fitting on the IN side of the regulator receiving air from the air tank. On the OUT side of the regulator, you may install a 1/4 NPT quick connect coupler, or use another 1/4 NPT compression fitting to route the air line to the source of the item that pressure is being regulated to. If you are plumbing to air locking differentials, we have included two 1/8 BSP Female to 1/4 NPT Male Adapters for this use. You may require a T-fitting (included in the package), depending on your application. 3. Adjusting pressure: The pressure regulator knob locks when pushed towards the unit. To adjust pressure, simply pull knob away from the regulator body and adjust as needed. Always lock the adjustment knob in place before using pressure-adjusted air supply to keep pressure regulated at a fixed pressure. (See Figure 2) Pressure Regulator Diagram: (Figure 2)

TIRE INFLATION GUN OPERATING INSTRUCTIONS Your Onboard Air System also comes with a Tire Inflation Gun for airing up tires and adding compressed air to any inflatable items with a valve stem. 1. Using the Tire Inflation Gun: Use a 1/4 Quick Connect Coupler, connect the Tire Inflation Gun to an air hose and connect to a tire valve stem or similar inflation collar by securing the folding lever on the Inflation Gun air chuck. 2. Filling Tires and other Inflatable Items: Squeeze the Inflation Trigger on the Inflation Gun by pressing it towards the handle of the gun. This will allow stored air from the air tank to flow through the gun and through the chuck into your tire or other inflatable items. 3. Checking Tire Pressure: To check tire pressure, release Inflation Trigger on Inflation Gun and allow the needle of the 0-200 PSI gauge to settle. Tire pressure will be able to be read only when the inflation trigger is released. WARNING: - Never operate the Inflation Gun at any pressure exceeding 200 PSI. - Use caution when attaching or removing air chuck from valve stems. - Always ensure that tire valve stems are tight before inflating tires. - Be careful to never inflate any tire or other inflatable items past its rated pressure to avoid explosion, possible injury, or death. Please Note: Not intended for use with regular portable compressors or units meant to be operated with an open ended air chuck. The Tire Inflation Gun is equipped with a close ended chuck and will hold pressure back, which could cause the hose to burst.

TROUBLESHOOTING GUIDE: PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION Tank pressure drops when compressor(s) shut off 1. Loose drain cock 2. Check valve leaking 3. Loose connections 1. Tighten drain cock 2. Replace check valve or compressor(s) 3. Check all connections with soap and water solution and tighten Compressor runs continuously and air flow lower than normal 1. Excessive air usage 2. Loose connections 3. Worn piston ring or inlet valve. 4. Clogged air filter element 1. Decrease air usage 2. Check all connections with soap and water solution and tighten. 3. Repair or replace compressor 4. Replace air filter element Compressor runs continuously causing safety valve (if equipped) to open 1. Bad pressure switch 2. Defective safety valve 1. Replace pressure switch 2. Replace safety valve Excessive moisture in discharge Compressor will not run Thermal overload protector cuts out repeatedly Excessive knocking or rattling 1. Excessive water in air tank 2. High humidity 1. No power, or power switch in OFF position 2. Blown fuse 3. Motor overheats 4. Faulty pressure switch. 1. Lack of proper ventilation or ambient temperature too high 2. Compressor valves failed 1. Loose mounting bolts 2. Worn bearing on eccentric or motor shaft 3. Cylinder or piston ring is worn 1. Drain tank, tilt tank to drain. Drain tank more frequently 2. Move compressor to area with less humidity, or use air line filter. 1. Make sure compressor switch is ON 2. Disconnect compressors from power source, replace fuse. (Refer to Specifications section for correct fuse amperage.) 3. Let compressors cool off for about 30 Minutes to allow thermal overload switch reset. 4. Replace pressure switch 1. Move compressor to well ventilated area, or area with lower ambient temperature 2. Repair or replace compressor 1. Tighten mounting bolts 2. Repair or replace compressor 3. Repair or replace compressor CAUTION: NEVER DISASSEMBLE COMPRESSOR WHILE COMPRESSOR IS PRESSURIZED.

COMPRESSOR APPLICATION GUIDE DUAL ONBOARD AIR SYSTEM To ensure that you get the highest level of satisfaction from your compressor performance, refer to information below: VIAIR COMPRESSOR REFERENCE CHART COMPRESSOR SERIES DUTY CYCLE MAX. WORKING PRESSURE (100 PSI @ 72 F) 090 SERIES 9% 120 PSI 092 SERIES 9% 120 PSI 095 SERIES 9% 120 PSI 097 SERIES 10% 130 PSI 098 SERIES 10% 130 PSI 100 SERIES 15% 130 PSI 250 IG SERIES 100% 150 PSI 275 SERIES 25% 150 PSI 280 SERIES 30% 150 PSI 325 SERIES 33% 150 PSI 330 IG SERIES 100% 150 PSI 350 SERIES 100% 150 PSI 380 SERIES 100% 200 PSI *55% 400 SERIES 33% 150 PSI 420 SERIES 33% 150 PSI 444 SERIES 100% 200 PSI *50% 450 SERIES 100% 150 PSI 450 IG SERIES 100% 150 PSI 460 SERIES 100% 150 PSI 480 SERIES 100% 200 PSI *50% *Duty Cycle at 200 PSI and 72 F. ABOUT COMPRESSOR DUTY CYCLE: Duty cycle refers to the amount of time a compressor can be operated in a given time period at 100 PSI, and a standard ambient temperature of 72 F. It is commonly expressed in percentage format: Compressor on time (on time + off time) = Duty Cycle %. ONE-HOUR DUTY CYCLE MINUTES ON / (100 PSI @ 72 F) MINUTES OFF 9% 5 Min. On / 55 Min. Off 10% 6 Min. On / 54 Min. Off 15% 9 Min. On / 51 Min. Off 20% 12 Min. On / 48 Min. Off 25% 15 Min. On / 45 Min. Off 30% 18 Min. On / 42 Min. Off 33% 20 Min. On / 40 Min. Off 50% 30 Min. On / 30 Min. Off 100% 1 Hour Run Time ABOUT RATED WORKING PRESSURE: To ensure trouble free service life of your compressor, always operate compressor within rated working pressure of the compressor. Never use a pressure switch with a higher cut-off pressure than compressor s rated working pressure.

AMERICAN WIRE GAUGE GUIDE 12-VOLT: Amp Draw Length of wire from battery to compressor (in feet) 5 10 15 20 5 16 16 16 14 10 16 14 12 10 15 16 12 10 10 20 14 10 10 8 25 14 10 8 6 30 12 10 8 6 40 12 8 6 6 50 10 6 6 4 60 10 6 4 4 Wiring Diagram - Figure 3: (Fuse not included) COMPRESSOR WIRING DIAGRAM To Lamp Circuit 12V 40A Relay Dash Panel To Keyed Power Source 87 30 85 86 12V 40A Relay Pressure Switch Fuse + - Battery 87 30 85 86 **Wiring Harness NOT included Rev.1

SPECIFICATIONS Part No. 20011 / 280C Dual OBA System Motor Voltage: 12 Volts Combined Max. Current Consumption: 33 Amps Motor Type: Permanent Magnetic Horsepower: 1/4 Max. Working Pressure: 150 PSI Max. Duty Cycle (@ 72 F & 100 PSI): 30% Minutes On/Off (@ 72 F & 100 PSI): 18 min ON/42 min OFF Max. Restart Pressure: 150 PSI Max. Ambient Temperature: 158 F Min. Ambient Temperature: -40 F Auto. Reset Thermal Protection: Yes Part No. 20013 / 380C Dual OBA System - Chrome Part No. 20014 / 380C Dual OBA System - Stealth Black Motor Voltage: 12 Volts Combined Max. Current Consumption: 44 Amps Motor Type: Permanent Magnetic Horsepower: 1/4 Max. Working Pressure: 200 PSI Max. Duty Cycle (@ 72 F & 100 PSI): 100% Minutes On/Off (@ 72 F & 100 PSI): 1 Hour Run Time Max. Restart Pressure: 200 PSI Max. Ambient Temperature: 158 F Min. Ambient Temperature: -40 F Auto. Reset Thermal Protection: Yes Part No. 20015 / 400C Dual OBA System Part No. 20016 / 400C Dual OBA System - Stealth Black Motor Voltage: 12 Volts Combined Max. Current Consumption: 59 Amps Motor Type: Permanent Magnetic Horsepower: 1/4 Max. Working Pressure: 150 PSI Max. Duty Cycle (@ 72 F & 100 PSI): 33% Minutes On/Off (@ 72 F & 100 PSI): 20 min ON/40 min OFF Max. Restart Pressure: 150 PSI Max. Ambient Temperature: 158 F Min. Ambient Temperature: -40 F Auto. Reset Thermal Protection: Yes Part No. 20017 / 450C Dual OBA System Motor Voltage: 12 Volts Combined Max. Current Consumption: 44 Amps Motor Type: Permanent Magnetic Horsepower: 1/4 Max. Working Pressure: 150 PSI Max. Duty Cycle (@ 72 F & 100 PSI): 100% Minutes On/Off (@ 72 F & 100 PSI): 1 Hour Run Time Max. Restart Pressure: 150 PSI Max. Ambient Temperature: 158 F Min. Ambient Temperature: -40 F Auto. Reset Thermal Protection: Yes

SPECIFICATIONS Part No. 20019 / 444C Dual OBA System Part No. 20020 / 444C Dual OBA System - Stealth Black Motor Voltage: 12 Volts Combined Max. Current Consumption: 40 Amps Motor Type: Permanent Magnetic Horsepower: 1/4 Max. Working Pressure: 200 PSI Max. Duty Cycle (@ 72 F & 100 PSI): 100% Minutes On/Off (@ 72 F & 100 PSI): 1 Hour Run Time Max. Restart Pressure: 200 PSI Max. Ambient Temperature: 158 F Min. Ambient Temperature: -40 F Auto. Reset Thermal Protection: Yes

LIMITED WARRANTY: VIAIR Corporation warrants this product, when properly installed and under normal conditions of use, to be free from defects in workmanship and materials for a period of one year from its original date of purchase. To receive warranty service or repair, please contact VIAIR Corporation. Returns should be made within one year of the date of purchase, after a Return Goods Authorization (RGA) number has been assigned by VIAIR Corporation. To obtain RGA, fax a copy of your receipt to (949) 585-0188. For complete warranty details, please visit: www.viaircorp.com/ warranty PLEASE NOTE: THIS WARRANTY COVERS PRODUCT DEFECTS ONLY; IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE. This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred. No part of the Manual shall be used, reproduced, translated, converted, adapted, stored in a retrieval system, communicated or transmitted by any means, for any commercial purpose, including without limitation, sale, resale, license, rental or lease, without the prior express written consent of VIAIR. VIAIR does not make any representations, warranties or guarantees, express or implied, as to the accuracy or completeness of the Manual. Users must be aware that updates and amendments will be made from time to time to the Manual. It is the user s responsibility to determine whether there have been any such updates or amendments. Neither VIAIR nor any of its directors, officers, employees or agents shall be liable in contract, tort or in any other manner whatsoever to any person for any loss, damage, injury, liability, cost or expense of any nature, including without limitation incidental, special, direct or consequential damages arising out of or in connection with the use of the Manual. 15 EDELMAN IRVINE, CA 92618 TEL: (949) 585-0011 FAX: (949) 585-0188 www.viaircorp.com