Type Y692 Gas Blanketing Regulator System

Similar documents
Type 1190 Low-Pressure Gas Blanketing Regulator

Y692VB Series Vacuum Breaker

T208VR Series Tank Blanketing Vacuum Regulator

Type ACE95jr Tank Blanketing Valve

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves

Type R622 Pressure Reducing Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

1805 Series Relief Valves

Type EZH Relief or Backpressure Regulator

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

1301 Series High-Pressure Regulators

66 Series Direct-Operated Regulators and Vacuum Service Equipment

Type 63EG Relief Valve or Backpressure Regulator

1805 Series Relief Valves

Type 99 Pressure Reducing Regulators

1301 Series High-Pressure Regulators

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type 92S Pilot-Operated Steam Regulator

971 Series Pressure Reducing Regulators

1305 Series Pressure Reducing Regulators

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

627 Series Pressure Reducing Regulators

Type Cronos Pressure Reducing Regulator

Type 299 Pressure Reducing Regulators

299H Series Pressure Reducing Regulators

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

64 Series Pressure Reducing Regulators

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

630 Series Regulators and Relief Valves

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

T208 Series Tank Blanketing Vapor Recovery Regulators

PRESSURE REGULATORS. Type B/240. Process Management TM

Type CT88 Backpressure Regulator

PRESSURE REGULATORS. Type A/140. Process Management TM

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

S300 Series. Valve Link. Features. Fisher Controls

Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

Noth American 7347 High Pressure Gas Regulators

RB Series Regulating System

299H Series. 1% Accuracy for Fixed Factor Billing (PFM) I nlet Pressure up to 175 psig / 12.1 bar. Rugged Construction. Compact.

RELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

299H Series Pressure Reducing Regulators

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Type FEQ Slam-Shut Valve

North American 7339 High Pressure Gas Regulators

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Bulletin 71.6:OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction

Types S100K and S102K Pressure Regulators

PRO-50 Instrument Supply Regulator

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Tank Blanketing Pressure Regulators RHPS Series

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

EZH and EZHSO Series Pressure Reducing Regulators

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

RELIEF VALVES. Type VS- FL. Process Management TM

SLAM-SHUT VALVES. Type BM5. Process Management TM

V DGX Series. Direct-Operated Regulators Manual D103834X012

627 Series Pressure Reducing Regulators

VS100 Series Slam-Shut Device

Model 1800 PFM Series Regulator. Technical Bulletin

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

Petro-Chemical & Analyzer Sampling Systems

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

Petro-Chemical & Analyzer Sampling Systems

EZR Series Pressure Reducing Regulator

MEGR-1627 Instruction Manual

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Type OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction. Bulletin 71.6 D102356X012. April 2018

North American 7337A/B/C-4 High Pressure Gas Regulators

299H Series Pressure Reducing Regulators

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Type 4660 High-Low Pressure Pilot

Series 100 Slam Shut Valve. Technical Bulletin

SLAM-SHUT VALVES. Type BM6X. Process Management TM

Fisher L2sj Low Emission Liquid Level Controller

Type ACE95jr Tank Blanketing Valve

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

Types 95L and 95H Pressure Regulators

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

299H Series Pressure Reducing Regulators

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Air Eliminators and Combination Air Eliminators Strainers

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Mark 958 Series Sanitary Gas Back Pressure Regulators

CS200 Series Commercial / Industrial Pressure Reducing Regulators

Transcription:

Bulletin 7:Y69 Type Y69 Gas Blanketing Regulator System November 14 W930-1 Figure 1. Type Y69 Low-Pressure Gas Blanketing Regulator Introduction An Accu-Pressure Gas Blanketing Regulator System reduces a high-pressure gas, such as Nitrogen, to maintain a protective environment above any liquid stored in a tank or vessel when the liquid is being pumped out. Also when the vessel is suddenly cooled, causing vapors inside the vessel to contract, the regulator system replaces the volume of contracting vapors with a volume of blanketing gas to prevent the internal vessel pressure from decreasing. In both cases, a slight positive vessel pressure prevents outside air, moisture and other contaminants from entering the vessel and the possible collapse of the vessel walls. The Type Y69 (Figure 1) is a direct-operated regulator used for accurate pressure control on very low-pressure blanketing systems. Downstream pressure is sensed through a pitot tube installed in the lower casing of the regulator for units with internal pressure registration or through a downstream control line for units with external pressure registration. The Type Y69 is available in NPS 1-1/ and / DN and 0 body sizes. Features Ease of Inspection and Maintenance The union nut connection between the body and actuator permits access to the disk and orifice by only removing the diaphragm casing assembly without removing the body from the line. Accuracy of Control Large diaphragm areas provide more precise control even at low-pressure settings and the pitot tube also creates a dynamic boost that helps provide greater capacity. Speed of Response The downstream pressure is sensed directly by the diaphragm through the pitot tube providing quick response. Ease of Installation The Type Y69 is easy to install in the pipeline because no additional connections are required. D3X01 www.fisherregulators.com

Bulletin 7:Y69 Specifications This section lists the specifications of thetype Y69 Gas Blanketing Regulator System. Factory specification, such as spring range and orifice size are stamped on the nameplate fastened on the regulator at the factory. Available Configurations Direct-operated pressure reducing regulator with external or internal pressure registration with seven outlet (control) pressure ranges from 1 in. w.c. to 7 psig / mbar to 0.48 bar. Available in NPS 1-1/ and / DN and 0 body sizes. Body Sizes and End Connection Styles (1) Cast Iron: NPS 1-1/ / DN, NPT, NPS / DN 0, NPT or CL FF Steel: NPS 1-1/ or / DN or 0, NPT, SWE, CL RF, CL300 RF or PN 16// Stainless steel: NPS 1-1/ or / DN or 0, NPT, CL RF, CL300 RF or PN 16// Maximum Inlet Pressure () psig / bar Maximum Outlet (Casing) Pressure () psig / bar Maximum Operating Outlet (Control) Pressure to Avoid Internal Part Damage () 3 psig / 0.1 bar above outlet (control) pressure setting Control Pressure Ranges () See Table 1 Flow Capacities See Table Relief Sizing Coefficients See Table 6 Orifice Size See Table 6 Pressure Registration Internal (standard) or External Spring Case Connection 1/4 NPT Temperature Capabilities () Nitrile (NBR): - to 180 F / -9 to 8 C Fluorocarbon (FKM): 0 to 300 F / -18 to 149 C Perfluoroelastomer (FFKM): - to 300 F / -9 to 149 C EthylenePropylene (EPDM): - to F / -9 to 13 C IEC Sizing Coefficients X T : 0.7 F D : 0.0 F L : 0.89 Approximate Weights Cast Iron Body: 4 lbs / kg Steel/Stainless steel Body: 7 lbs / 6 kg Canadian Registration Number (CRN) Approved PED (Pressure Equipment Directive) Category The Type Y69 may be used as a safety accessory with pressure equipment in the PED 97/3/EC Category I. Construction Materials Body, Union Nut, Spring Case and Lower Casing Assembly: Cast iron, WCC steel, CF8M Stainless steel Control Spring, Control Spring Seat, Split Ring and Diaphragm Plate: Plated steel Diaphragm: Nitrile (NBR) (standard), Fluorocarbon (FKM), Ethylenepropylene (EPDM), Silicone (VMQ) O-rings: Nitrile (NBR), Fluorocarbon (FKM), Perfluoroelastomer (FFKM), Ethylenepropylene (EPDM) Orifice, Pusher Post, Pusher Post Connector, Lever Assembly, Stem and Pitot Tube: Stainless steel Gasket: Composition Disk Assembly: Nitrile (NBR) and Stainless steel, Fluorocarbon (FKM) and Stainless steel, Polytetrafluoroethylene (PTFE) and Stainless steel or Ethylenepropylene (EPDM) and Stainless steel 1. Fabricated by using slip-on flanges and socket welding nipples into body.. The pressure/temperature limits in this Bulletin and any applicable standard limitation should not be exceeded.

Bulletin 7:Y69 Table 1. Control Pressure Ranges Light Spring Assembly Heavy spring Assembly CONTROL PRESSURE RANGE WITH CASE BARREL POINTED DOWN 1 to 3 in. w.c. / to 7 mbar ()(3) 3 to 11 in. w.c. / 7 to 7 mbar ()(4) 6. in. w.c. to 1. psig / 16 mbar to 83 mbar () 0.7 to psig / 48 mbar to bar 1 to 3. psig / 69 mbar to 0. bar to. psig / to 0.38 bar 4 to psig / 0.8 to bar CONTROL SPRING COLOR CODE Brown Iridite Green Blue Orange Silver with green stripe Silver CONTROL SPRING PART NUMBER 1D8970 0B019770 0B019470 0B0196703 0A081 0Y066470 1H804703 1. Install with spring case pointing down to achieve low setpoints in these spring ranges.. Do not use Fluorocarbon (FKM) diaphragm with these springs at diaphragm temperature lower than F / 16 C. 3. Installation with spring case pointing up will change outlet (control) pressure range to 3 to in. w.c. / 7 to 1 mbar. 4. Installation with spring case pointing up will change outlet (control) pressure range to. to 14 in. w.c. / 14 to 3 mbar.. Installation with spring case pointing up will change outlet (control) pressure range to 7. in. w.c. to 1.3 psig / 19 to 90 mbar. SPRING WIRE DIAMETER SPRING FREE LENGTH In. mm In. mm 0.9 8 0.187 0. 0.0 0.363 0.6.77 3.76 4..71 6.3 9. 6.1 6.00 6.00 6.00 6.00 6.00 6.00 Table. Flow Rate Conversion (1) MULTIPLY MAXIMUM PUMP RATE OUT BY TO OBTAIN U.S. GPM U.S. GPH m 3 /hr Barrels/hr Barrels/day 1. Gas flow of blanketing gas to replace liquid pumped out. 8.01 0.1337 1.6 0.3 SCFH SCFH Nm 3 /H SCFH SCFH Table 3. Conversion Factors (for converting Nitrogen flow rates to other gas flow rates) BLANKET GAS SPECIFIC GRAVITY CORRECTION FACTOR Natural Gas 0. 1.70 Air 0 0.98 Dry CO 1. 0.797 Correction Factor = 0.98 SG Table 4. Gas Flow Required for Thermal Heating (Outbreathing) or Cooling (Inbreathing) per API 00 (Interpolate for Intermediate size) VESSEL CAPACITY AIR FLOW RATE REQUIRED Barrel Gallon Liter SCFH Nm 3 /h 00 0 00 00 1,000 4,000 84,000 0 16,000 79,00 9,000 318,000 00 0 00 1.6.7 1.3 6.8 3.6 3000 00 000,000,000 16,000 168,000,000 4,000 630,000 477,000 636,000 79,000 1,90,000,38,000 3000 00 000,000,000 80.4 7 134 68,000,000 30,000 3,000,000 8,000 1,00,000 1,,000 1,470,000 1,680,000 3,180,000 3,9,000 4,769,000,64,000 6,39,000,000 4,000 8,000 31,000 34,000 36 643 0 831 911 4,000 0,000,000 70,000 80,000 1,890,000,,000,,000,9,000 3,3,000 7,4,000 7,949,000 9,39,000 11,19,000 1,718,000 37,000,000 44,000 48,000,000 99 7 1179 186 1394 90,000,000 1,000 1,000 1,000 3,780,000 4,0,000,0,000,880,000 6,7,000 14,308,000,898,000 19,078,000,437,000,437,000 6,000,000 68,000,000 8,000 1 18 18 198 180,000 7,,000 8,616,000 90,000 41 3

Bulletin 7:Y69 Type Y69 Type Y69 BLOCK VENT SUPPLY PRESSURE BLOCK VENT VENT POINTED DOWNWARD GAS BLANKETING PRESSURE INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE LIQUID TYPE Y69 WITH INTERNAL REGISTRATION Type Y69 BLOCK VENT INLET PRESSURE CONTROL PRESSURE SUPPLY (OUTLET PRESSURE) ATMOSPHERIC PRESSURE PRESSURE VENT VENT POINTED DOWNWARD BLOCK GAS BLANKETING PRESSURE LIQUID TYPE Y69 WITH EXTERNAL REGISTRATION A63 INLET PRESSURE CONTROL PRESSURE (OUTLET PRESSURE) ATMOSPHERIC PRESSURE ET PRESSURE Figure. Type Y69 Operational Schematics NTROL PRESSURE (OUTLET PRESSURE) MOSPHERIC PRESSURE 4

Bulletin 7:Y69 Principle of Operation The Type Y69 Gas Blanketing Regulator reduces a high-pressure gas to maintain a positive low-pressure of blanket gas over a stored liquid when the liquid is being pumped out of the vessel (see Figure ). Also when the vessel (or tank) is suddenly cooled, causing vapors to contract, the regulator replaces the volume of contracting vapors with a volume of blanketing gas to prevent the internal vessel pressure from decreasing. In both cases, a positive vessel pressure prevents outside air from entering the vessel and reduces the possibility of atmospheric pressure collapsing the vessel. Gas blanketing regulators respond to a slight decrease in internal vessel pressure by throttling open to increase the flow rate of gas into the vessel. When the vessel s liquid level has been lowered to the desired point and the vapor pressure re-established, the regulator throttles closed. When the liquid level drops and vessel pressure decreases below the setting of the control spring, the spring force on the diaphragm opens the disk assembly to supply the required flow of gas to the vessel. When vessel pressure has been satisfied, control pressure tends to increase slightly, acting on the diaphragm. When the control (vessel) pressure exceeds the control spring setting, the diaphragm moves to close the disk assembly. The Type Y69 Gas Blanketing Regulator provides a constant set pressure for accurate gas blanketing. When vessel pressure decreases below the control spring setpoint, the force of the spring moves the disk away from the orifice allowing gas to flow into the vessel. As the vessel pressure increases, the increase is sensed by the diaphragm through the pitot tube or control line. This movement of the diaphragm causes the disk to move toward the orifice, decreasing the flow of blanketing gas. When the vessel pressure reaches the system setpoint, the disk will seat against the orifice shutting off the flow of gas. Installation Install the Type Y69 regulator with the spring case barrel pointed down. This will assure that the lowest set pressure shown in Table 1 is achieved. Flow through the regulator body is indicated by the flow arrow cast on the body. If a block valve is required, install a full flow valve between the regulator and the blanketed vessel. Sizing Tank Blanketing Systems When sizing a gas blanketing regulator system for a low pressure blanketing application, you must consider the replacement of blanketing gas required for the liquid loss during pump out of the vessel and also the condensation/contraction of vessel vapors during atmospheric thermal cooling. Direct Displacement The direct displacement method should be used with extreme caution. The direct displacement method determines the amount of blanketing gas required to replace liquid pumped out of the tank. Direct displacement does not allow for fluctuating temperature or other factors that may affect pressure in the vapor space. This method is typically applied to tanks operating at constant temperature and containing non-flammable, non-volatile products. where, Q total = Q pump Q total = Required Flow Rate Q pump = Required Flow Rate to replace pumped out liquid from Table 1

Bulletin 7:Y69 API 00 The American Petroleum Institute Standard 00 (API 00) sizing method accounts for liquid pump-out as well as contraction of tank vapors due to cooling. When using API methods: where, Q total Q total = Q pump + Q thermal = Required Flow Rate Q pump = Required Flow Rate to replace pumped out liquid from Table 1 Q thermal = Required Flow Rate due to thermal cooling. See Thermal Equations 1 to 4 below or Table. Thermal Equations For tanks up to 8,000 gallons / 3179 m 3 capacity, use one of the following equations: Equation 1: Equation : Q thermal [SCFH Air] = V tank x 0.038 Q thermal [SCFH Nitrogen] = V tank x 0.038 x Equation 3: Equation 1: Q therma l [Nm3 /h Air] = V tank x 0. Q thermal [Nm 3 /h Nitrogen] = V tank x 0. x where, For Equations 1 and : V tank = tank volume, gallons For Equations 3 and 4: V tank = tank volume, m 3 For tanks greater than 8,000 gallons / 3179 m 3 capacity: See Table. Depending on the method, there can be a significant difference in the calculated required capacity. No matter which method is used, the tank must be equipped with supplemental venting to protect the tank, product and personnel in cases of equipment failure, fire exposure or other conditions that could cause the tank pressure or vacuum to exceed operating limits. Sizing can be done by following these steps: 1. Determine the gas flow rate required to replace the liquid being pumped out (see Table ).. Using the established procedures from the American Petroleum Institute Standard 00 (API 00), determine the gas flow rate due to inbreathing caused by atmospheric thermal cooling (see Table 4). 3. Add the requirements of 1 and and select the regulator size, based on total capacity required from Table 6. Sample sizing problem for blanketing applications: Service Conditions: Vessel Capacity......... 4,000 gallons / 9,000 L Pump In/Out Capacity.. gallons/minute / 70 L/m Inlet Pressure Source..... psig / bar Nitrogen Desired Blanket Setpoint........ 1 in. w.c. / mbar Sizing and Selection Methodology: 1. From Table the desired air flow rate due to pump out equals GPM x 8.01 = 13 SCFH / 3. Nm 3 /h air.. From Table 4, the required air flow due to thermal cooling = 0 SCFH / 6.8 Nm 3 /h air. 3. Total flow required for pump out and thermal cooling is 13 + 0 = 3 SCFH / Nm 3 /h air. 4. Convert to nitrogen by dividing the total air flow by the square root of the specific gravity of nitrogen: 3 0.97 = 48 SCFH /. Nm 3 /h nitrogen (See Table 3 for the conversion).. From Table, a Type Y69 in either an NPS 1-1/ and / DN and 0 body sizes and a 3/8 in. / 9. mm orifice will flow 36 SCFH / Nm 3 /h nitrogen at psig / bar inlet pressure. This satisfies the required flow of 48 SCFH /. Nm 3 /h nitrogen. 6

Bulletin 7:Y69 Capacity Information Table gives the typical regulating capacities at selected inlet pressures and outlet (control) pressure settings. Flows are in SCFH ( F and 14.7 psia) of 0.97 specific gravity nitrogen. For gases of other specific gravities, multiply the given capacity of nitrogen by 0.98 and divide the given capacity by the square root of the appropriate specific gravity of the gas required. Then, if capacity is desired in normal cubic meters per hour at 0 C and 13 bar, multiply SCFH by 0.068. To determine wide-open flow capacities for relief sizing, use the following formula: where, 3417 P Q = C g P 1 SIN DEG GT C 1 P 1 C g = gas sizing coefficient from Table 6 C 1 = C g /C v or 3 from Table 6 G = gas specific gravity (air = ) P 1abs = inlet pressure, psia (add 14.7 psi to gauge inlet pressure to obtain absolute inlet pressure) Q = flow rate, SCFH T = absolute temperature in Rankine of gas at inlet Ordering Information When ordering, specify: 1. Type of gas being controlled (nitrogen fuel gas, etc.); list any factors such as impurities in the gas that may affect compatibility of the gas with the regulator trim parts.. Specific gravity of the gas 3. Temperature of the gas 4. Range of flowing inlet pressures to regulator. Flow rates a) Minimum controlled flow b) Normal flow c) Maximum flow 6. Line size and end connection size of adjacent piping. Adjacent downstream piping must be the same size as the regulator body or longer. 7. Vessel size 7

Bulletin 7:Y69 Table. Blanketing Regulating Capacities in SCFH / Nm 3 /h of 0.97 Specific Gravity Nitrogen BODY SIZE NPS 1-1/ / DN OUTLET PRESSURE RANGE (1), ACCURACY AND SPRING COLOR 1 to 3 in. w.c. / to 7 mbar -1 to in. w.c. / - to mbar Brown 3 to 11 in. w.c. / 7 to 7 mbar -1 to in. w.c. / - to mbar Iridite 6. in. w.c to 1. psig / 16 to 83 mbar, Green or 0.7 to psig / 48 mbar to bar, Blue 0. psig / 14 mbar 1 to 3. psig / 69 mbar to 0. bar 0.6 psig / 41 mbar Orange to. psig / to 0.38 bar 0. psig / 34 mbar Silver with green stripe to. psig / to 0.38 bar 1 psig / 69 mbar Silver with green stripe 4 to psig / 0.8 to bar 1 psig / 69 mbar Silver 4 to psig / 0.8 to bar psig / bar Silver OUTLET PRESSURE SETTING 1 in. w.c. / mbar 3 in. w.c. / 7 mbar 7 in. w.c. / 17 mbar 1. psig / 0. bar 3 psig / 0.1 bar psig / 0.34 bar psig / 0.34 bar psig / bar psig / bar INLET PRESSURE ORIFICE SIZE, IN. / mm 1/4 / 6.4 3/8 / 9. 1/ / 13 3/4 / 19 1 / 1-3/16 / 30 psig bar SCFH Nm 3 /h SCFH Nm 3 /h SCFH Nm 3 /h SCFH Nm 3 /h SCFH Nm 3 /h SCFH Nm 3 /h 80 80 0. 1 13 0 6 14 30 0 3 7 14 30 0 3 3 0.34.8. 8.6 0.34.8. 8.6 0.03 0.07 0.34 0.9 1.7 3.4 0.41 0.97.1 3.4 0.1 0.48 0.97.1 3.4.4..4. 1.7.8. 1.7.8. 3 680 30 00 34 43 4 4 4 3 680 30 00 34 43 4 4 4 330 470 770 0 180 30 370 6 90 789 14 7 30 1180 1380 1970 31 4 708 944 1 18 361 4 341 3 9 74 8 990 13 1 9.7 18. 7.6 4.3 67.0 9 116 11 11 11 9.7 18. 7.6 4.3 67.0 9 116 11 11 11 8.8 1.6.6 34.0 49.6 81. 144.8 1.1 38.1 9. 74.0 9.1 31.6 37.0.8 84.7 1 19.0.3 9. 63.3 73.8 94.9 7.4 33.7 4. 61. 80.1 8 970 30 36 36 36 970 30 36 36 36 630 90 4 6 6 789 17 36 4890 71 18,030 0 370 400 70 17,0 30 1380 1970 9 3470 0 1890 0 33 90 6390 8680 3 7 16 3 3148 341 193 1731 6 3934 31 631 866 1. Spring ranges based on regulator installation with the spring case pointed down. - Light shaded areas show where indicated droop would be exceeded regardless of capacity. - Dark shaded areas show where maximum operating inlet pressure for a given orifice size is exceeded. 6.0 41.8 63.0 6.0 41.8 63.0 1 4.3 69.4 1 1.1 46.6 84.6 191 483 41. 63. 11 188 46 7.6.8 93.0. 0.7 88.7 14 171 33 7.4 3 44.3 84.4 94.9 139 46.4 7.0 71.7 143 1 3 800 4 4900 4900 800 4 4900 4900 870 1300 4900 6 6 1 7 00 800 11,990 370 3700 7380,0 1180 0 9 4730 680 0 7 3790, 1338 1967 3 91 4643 666 18 3384 3777 7 866,30 4.0 113 4.0 113 3.3 34.8 67. 33.8 74.0 11 16 31 63. 99. 198 88 31.6 4.3 4.9 74.0 3.9.7 78.0 14 67. 90.7 1 141 3 74 380 3880 3880 3700 380 3880 3880 3700 13 70 6 6 0 4730 9470 13,3 3 70 11,680 18 370 9 330 4 7730 18 97 3148 47 36 1 643 866 87.9 4 4 99. 87.9 4 4 99. 3.9.6 4.9 4 38 6 188 313 63. 8 86.6 1 7 69.9 84.4 173 3 1180 18 31 6 6 6 9790 1,00 40 7470 0 8 33 4 63 18 3148 13 471 69 708 31.6 84.7 71.3 18 33 64.7 0 76.1 88.7 1 148 67. 84.4 8 190 8 8 1330 90 4730 6 3 30 8 631 370 33 480 63 990 464 69 7869 76.1 76.1 3.6 6 86.3 76.1 63. 88.7 13 80.1 1 - continued - 8

Bulletin 7:Y69 Table. Blanketing Regulating Capacities in SCFH / Nm 3 /h of 0.97 Specific Gravity Nitrogen (continued) BODY SIZE NPS / DN 0 OUTLET PRESSURE RANGE (1), ACCURACY AND SPRING COLOR 1 to 3 in. w.c. / to 7 mbar -1 to in. w.c. / - to mbar Brown 3 to 11 in. w.c. / 7 to 7 mbar -1 to in. w.c. / - to mbar Iridite 6. in. w.c to 1. psig / 16 to 83 mbar, Green or 0.7 to psig / 48 mbar to bar, Blue 0. psig / 14 mbar 1 to 3. psig / 69 mbar to 0. bar 0.6 psig / 41 mbar Orange to. psig / to 0.38 bar 0. psig / 34 mbar Silver with green stripe to. psig / to 0.38 bar 1 psig / 69 mbar Silver with green stripe 4 to psig / 0.8 to bar 1 psig / 69 mbar Silver 4 to psig / 0.8 to bar psig / bar Silver OUTLET PRESSURE SETTING 1 in. w.c. / mbar 3 in. w.c. / 7 mbar 7 in. w.c. / 17 mbar 1 psig / 69 mbar 3 psig / 0.1 bar psig / 0.34 bar psig / 0.34 bar psig / bar psig / bar INLET PRESSURE ORIFICE SIZE, IN. / mm 1/4 / 6.4 3/8 / 9. 1/ / 13 3/4 / 19 1 / 1-3/16 / 30 psig bar SCFH Nm 3 /h SCFH Nm 3 /h SCFH Nm 3 /h SCFH Nm 3 /h SCFH Nm 3 /h SCFH Nm 3 /h 80 80 0. 1 13 0 6 14 30 0 3 7 14 30 0 3 3 0.34.8. 8.6 0.34.8. 8.6 0.03 0.07 0.34 0.90 1.7 3.4 0.41 0.97.1 3.4 0.1 0.48 0.97.1 3.4.4..4. 1.7.8. 1.7.8. 3 680 30 00 34 3 680 30 00 34 330 470 770 0 180 30 370 90 789 14 7 30 1180 1380 1970 31 4 708 944 1 18 361 4 341 3 9 74 8 990 13 1 8.6 18. 7.6 4.3 67.0 9 8.6 18. 7.6 4.3 67.0 9 8.8 1.6.6 34.0 49.6 81. 144.8 1.1 38.1 9. 74.0 9.1 31.6 37.0.8 84.7 1 19.0.3 9. 63.3 73.8 94.9 7.4 33.7 4. 61. 80.1 8 930 30 36 44 44 930 30 36 44 44 630 90 4 6700 30 1970 3390 71 17 33 00 19,8 30 1380 1970 9 3470 0 1890 0 0 90 6390 8680 3 7 16 3 3148 341 193 1731 6 3934 31 631 866 1. Spring ranges based on regulator installation with the spring case pointed down. - Light shaded areas show where indicated droop would be exceeded regardless of capacity. - Dark shaded areas show where maximum operating inlet pressure for a given orifice size is exceeded. 4.9 41.8 63.0 118 118 4.9 41.8 63.0 118 118 1 4.3 69.4 1 180 7.6.8 90.9 191 46.6 88.7 1 31 7.6 37.0.8 93.0. 0.7 4.9 14 171 33 7.4 3 44.3 84.4 94.9 139 46.4 7.0 71.7 143 1 3 800 4 340 340 800 4 340 340 870 1300 4900 7180 13 8 8130 11,990 4180 7930 11,0 1180 0 9 4730 680 0 7 3790, 1338 1967 3 91 4643 666 18 3384 3777 7 866,30 4.0 113 9. 9. 4.0 113 9. 9. 3.3 34.8 67. 19 3.9 76.1 18 31 69.7 11 13 306 31.6 4.3 4.9 74.0 7 3.9.7 78.0 14 67. 90.7 1 141 3 74 00 0 00 0 13 80 40 680,60 16,730 4730 770 14,480 18 370 9 4 63 18 3148 13 471 69 708 7 16 7 16 3.9.6 6.7 8 448 6 388 63. 8 1 148 67. 84.4 8 190 0 4630 0 4630 1180 18 31 330 7730 13,490 0 880,40 0 8 9 4 63 18 3148 13 471 69 708 134 14 9 134 14 9 31.6 84.7 86.6 7 36 68.3 8 80 76.1 1 148 67. 84.4 8 190 930 4 930 4 1330 90 4730 3390 87 300 71 370 33 480 63 990 464 69 7869 9 114 9 114 36. 6 90.9 3 81.7 191 63. 88.7 13 80.1 1 9

Bulletin 7:Y69 8.94 / 7 1/4 NPT DOWNSTREAM CONTROL LINE CONNECTION 8 / 64.94 /.88 / 149 17.44 / 443 NPT DIMENSIONS 8.94 / 7 A 8 / 64 17.44 / 443 IN. / mm A - CAST IRON FLANGES ARE IN. / 4 mm FACE-TO-FACE; STEEL, STAINLESS STEEL AND HASTELLOY C FLANGES ARE 14 IN. / 36 mm FACE-TO-FACE. Figure 3. Dimensions FLANGED DIMENSIONS Table 6. Orifice Sizes and Coefficients for Relief Valve Sizing BODY SIZE ORIFICE SIZE NPS DN In. mm 1-1/ and and 0 1/4 3/8 1/ 3/4 1 1-3/16 6.4 9. 13 19 30 WIDE-OPEN Cv WIDE-OPEN Cg C1 1.1 3.14.43 11.9 6 3.0 111 190 4 700 9 3 Hastelloy C is a mark owned by Haynes International, Inc.

Bulletin 7:Y69 Ordering Information Carefully review the Specifications section, then specify the desired selection on the Ordering Guide. If a pilot Ordering Guide Body Size (Select One) NPS 1-1/ / DN NPS / DN 0 Body Material and End Connection Style (Select One) Cast Iron NPT*** CL FF (NPS / DN 0 body only)* WCC Steel NPT*** SWE** CL RF** CL300 RF** PN 16//* Spring Case Material (Select One) Cast iron*** WCC steel*** CF8M Stainless steel** CF8M Stainless Steel NPT*** CL RF** CL300 RF** PN 16// RF* Diaphragm Case Material (Select One) Cast iron*** WCC steel*** CF8M Stainless steel** Trim Material (Select One) 304 Stainless steel*** 316 Stainless steel** Diaphragm Material (Select One) Nitrile (NBR) (standard)*** Fluorocarbon (FKM)*** Ethylenepropylene (EPDM)*** Silicone (VMQ)*** Disk Material (Select One) Nitrile (NBR) (standard)*** Fluorocarbon (FKM)*** Polytetrafluoroethylene (PTFE)*** Ethylenepropylene (EPDM)*** setpoint is not requested, the regulator will be factory set at the approximate midrange. Orifice Size (Select One) 1/4 in. / 6.4 mm*** 3/4 in. / 19 mm*** 3/8 in. / 9. mm*** 1 in. / mm*** 1/ in. / 13 mm*** 1-3/16 in. / 30 mm*** Outlet Pressure Range (Select One) 1 to 3 in. w.c. / to 7 mbar, Brown*** 3 to 11 in. w.c. / 7 to 7 mbar, Iridite*** 6. in. w.c. to 1. psig / 16 to 83 mbar, Green*** 0.7 to psig / 48 mbar to bar, Blue*** 1 to 3. psig / 69 mbar to 0. bar, Orange*** to. psig / to 0.38 bar, Silver with Green stripe*** 4 to psig / 0.8 to bar, Silver*** Pressure Registration (Select One) Internal*** External** PTFE Diaphragm Protector (Optional) Yes CRN (Canadian Registration Number) Required (Optional) Yes PED (Pressure Equipment Directive) Conformity (Optional) Yes Replacement Parts Kit (Optional) Yes, send one replacement parts kit to match this order. 11

Bulletin 74:1:Y69 Ordering Guide (continued) Regulators Quick Order Guide * * * Readily Available for Shipment * * Allow Additional Time for Shipment * Special Order, Constructed from Non-Stocked Parts. Consult your local Sales Office for Availability. Availability of the product being ordered is determined by the component with the longest shipping time for the requested construction. Tank Blanketing Specification Worksheet Application Specifications: Tank Size Pump In Rate Pump Out Rate Blanketing Gas (Type and Specific Gravity) Pressure Requirements: Maximum Inlet Pressure (P 1max ) Minimum Inlet Pressure (P 1min ) Control Pressure Setting (P ) Maximum Flow (Q max ) Accuracy Requirements: 0. in. w.c. / 0.6 mbar 0. in. w.c. / 1 mbar 1 in. w.c. / mbar in. w.c. / mbar Other Other Specifications: Is a vapor recovery regulator required? Yes No Special Material Requirements: Ductile Iron Steel Stainless steel Other Other Requirements: Industrial Regulators Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 070 USA Tel: +1 800 8 83 Outside U.S. +1 97 48 374 Asia-Pacific Shanghai 16, China Tel: +86 1 89 9000 Europe Bologna 013, Italy Tel: +39 01 419 0611 Middle East and Africa Dubai, United Arab Emirates Tel: +971 4811 8 Natural Gas Technologies Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 070 USA Tel: +1 800 8 83 Outside U.S. +1 97 48 374 Asia-Pacific Singapore 18461, Singapore Tel: +6 6770 8337 Europe Bologna 013, Italy Tel: +39 01 419 0611 Chartres 8008, France Tel: +33 37 33 47 00 Middle East and Africa Dubai, United Arab Emirates Tel: +971 4811 8 TESCOM Emerson Process Management Tescom Corporation USA - Headquarters Elk River, Minnesota 330-44, USA Tels: +1 763 41 338 +1 800 447 0 Europe Selmsdorf 393, Germany Tel: +49 3883 31 87 Asia-Pacific Shanghai 16, China Tel: +86 1 89 9499 For further information visit www.fisherregulators.com The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser. Emerson Process Management Regulator Technologies, Inc., 1994, 14; All Rights Reserved