KDV HIGH ACCURACY GLASS TUBE ROTAMETER

VA40 - VA45 Technical Datasheet

GA24 Technical Datasheet

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

RCD - Ultra-Rugged Differential Pressure Flowmeter

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Liquid level switch BM 34

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

KOBOLD KSM FLOWMETER. User Instructions

Measurement of Low GAS & Liquid Flows

Glass tube flowmeters Series 2000

Level transmitter LT 100

RCD. Differential Pressure Flowmeters. for Liquids or Gases

Variable Area Flow Meters

Flow Measurement Equipment Armored Purge Meters

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

GA24. GA24 Handbook. Variable-area flowmeter. KROHNE 02/ MA GA24 R01 en

Tank Blanketing Pressure Regulators RHPS Series

Liquid level instruments BM 24 /BM 51

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Variable Area Flow Meters

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Variable Area Flowmeter Rotameter The Original

Ultrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63

Porter Analytical & Industrial Products

Laboratory Flowmeters

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

9700 Transmitter Submersible hydrostatic level transmitter

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Operating instructions for variable area flow meter with needle valve. Model: UVR/UTR

ED 701 Hygenic Pressure Transmitter

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

GILMONT ACCUCAL FLOWMETERS

High-performance submersible pressure transmitter For level measurement Model LH-10

Variable Area Flow Meters. VS Series

Mass Flow Controllers

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

Expansion Thermometers Stainless Steel Series, Model 70

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Sanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Technical Information. Overview Rotameter. TI 1R1A0-E-H 4th edition

SITRANS P measuring instruments for pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Manual retractable fitting with safe-to-operate rotary drive

FVA Tubux M30 Variable Area Flowmeter. Operating Instructions. MECON GmbH 07/2013 OI_FVA_Tubux_M30_EN

Pneumatic retractable fitting for simple commercially available control units or process applications

Porter Lab & Analytical Products

ZUERCHER MRCib Series

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications

PTFE-SINGLE GLASS FLOW METERS

Model 2851 CONSTANT FLOW REGULATOR

Differential pressure

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Flow metering in gases Introduction to COMBIMASS family

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

Tank Blanketing Regulators

Mechanical Pressure Measurement

OPTIBAR P 1010 C Technical Datasheet

For Multi-Parameter Meters see mvx

Pressure Equalising Valves Model , for Differential Pressure Gauges

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

780S Ultra High Purity Series

Tank Blanketing Regulators

C-Flow Coriolis Mass Flow Meters

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

Ultrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Mark 958 Series Sanitary Gas Back Pressure Regulators

Electronic relative and differential pressure switch type 616

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

DK32 - DK34 - DK37 Technical Datasheet

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

INDUSTRIAL EXCESS ESS FLOW VALVES

Level switches Series LD Vibrating fork level switch for liquids and solids

Installation and Operating Instructions Bypass Flow Meter DST

Level switches Series LD Vibrating fork level switch for liquids and solids

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S

Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Mass Flow Controller (MFC) for Gases

Technical Data for Alicat MS Series Mass Flow Meters

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Torque Tube TB300 Digital Transmitters

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Armatures for analytical probes

FVA Trogflux variable area flowmeter. Operating Instructions. MECON GmbH 05/2013 OI_FVA_Trogflux_EN

Pressure Transmitters 36 F-27839

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Transcription:

KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design Flanged, Threaded or Tri-Clamp Fittings ±1.0% of Full Scale Accuracy Optional Surface Finishes for Food and Pharmaceutical Applications Optional Switches Special Calibrations for Compressed Gases and Viscous Media USA KOBOLD Instruments Inc. 1801 Parkway View Drive USA- Pittsburgh, PA 15205 +1 412-788- 2830 Fax +1 412-788- 4890 E-mail: info@koboldusa.com CANADA KOBOLD Instruments Canada Inc. 9A Aviation Pointe-Claire, QC H9R 4Z2 +1 514-428-8090 Fax +1 514-428-8899 E-mail: kobold@kobold.ca Visit KOBOLD Online at www.kobold.com Model: KDV Rev. 12/13

Features Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design Flanged, Threaded or Tri-Clamp Fittings ±1.0% of Full Scale Accuracy Optional Surface Finishes for Food and Pharmaceutical Applications Optional Switches Special Calibrations for Compressed Gases and Viscous Media The KDV series are high quality glass tube variable-area flowmeters (rotameters). This classic design is still the most widely used flowmeter style in the world today. The simple variable-area design makes the flowmeter a perfect choice when ease of installation and operation is a must. The KDV features a tempered glass measuring tube which is inert to most chemicals. This tube is suitable for measurement of both liquids and gases. Liquid flow ranges are available from 0.01 to 0.1 GPH through 265 to 2645 GPH water. Gas flow ranges are available from 0.025 to 0.25 SCFH through 670 to 6700 SCFH air. Custom Calibrations are Standard Each KDV series is built specifically for the application. The KDV will arrive with a direct reading scale which is calibrated for your operating conditions. The KDV can be calibrated for viscous media, chemicals, and various compressed gases. The scale will be provided in any measuring units the user specifies when ordering. The application datasheet provided with the operating conditions will provide all the data required to properly factory calibrate the flowmeter. A KDV for Every Application The KDV is ideal for industrial and sanitary applications. The standard model is available with NPT threaded or flanged connections. Polished finishes and Triclamp fittings for food and pharmaceutical applications are available. Specifications Flow Ranges Water: 0.01 to 0.1 through 265 to 2645 GPH Air: 0.025 to 0.25 through 670 to 6700 SCFH Body Size: 1/2, 1, 1-1/2 and 2 Maximum Operating Pressure: 1/2" through 1 : 145 PSIG 1-1/2": 131 PSIG 2": 102 PSIG Process Temperature Range: Fittings: Float Stops: KDV Series Glass Tube Rotameter w/o Switch Contact: -4 F to 212 F Ambient Temp. Range: Reed Contact: With Proximity Switch: -13 F to 212 F With Reed Switch: -4 F to 185 F Wetted Materials Measuring Tube: Borosilicate Glass Float: 316 SS, Hastelloy, Proximity Sensor: aluminum, PTFE or PP, based on model code Seals: NBR, FKM, EPDM or FFKM 316 SS or PVDF based on model code PVDF Body Materials (Non-Wetted) Tube Housing: 316L SS Union Nut: Painted aluminum or 316 SS based on model code Note: Electropolished finish for food and pharmaceutical applications available for all stainless steel surfaces. Switch Specifications The KDV can be fitted with up to two adjustable switches. Switch types available are bistable reed contacts and NAMUR proximity sensors. Bistable reed contact Max. 12 VA, 30 VDC, 0.5 Amp NEMA 3R/IP44 Intrinsically safe output, NAMUR per DIN 19234 (use the REL-6003, -6004 or -6005 as a proximity sensor isolation relay/intrinsic safety barrrier) NEMA 6/IP67 Electical Connection: Terminal box

Ordering Information KDV series model code key (use tables 1 through 6 on the following pages to completely specify your model) Example KDV Part Number KDV - V -1-05 - 13-2 - 1 Model Float Material Range Code Fitting Style Oring material Options Table 1: Base Model KDV-V = Flowmeter with threaded connection KDV-F = Flowmeter with 150 LB ANSI flange KDV-A = Tri-clamp fitting, wetted surfaces electropolished to <Ra 32 µ In. (0.8 µ M) Table 2: Float Materials 1 = 316 Stainless Steel 6 = Hastelloy B2 2 = PTFE Clad 7 = Hastelloy C4 3 = PTFE 8 = Polypropylene 4 = Aluminum S2 Table 3: Meter Size/Range Code Flow Range (GPH Water) Flow Range (SCFH Air) Max. Pressure Meter Range Cone Float Material (reference Table 2 for material codes) drop (PSI) Size Code Shape 1,6 or 7 2 3 1,6 or 7 3 4 8 01 G13.11 0.01-0.10 - - 0.06-0.56 0.025-0.25 0.025-0.25-0.03 02 G14.06 0.017-0.17 - - 0.09-0.9 0.042-0.42 0.042-0.42-0.04 03 G14.08 0.026-0.26 - - 0.14-1.4 0.07-0.7 0.07-0.7-0.06 04 G15.07 0.040-0.40 - - 0.21-2.1 0.1-1.0 0.1-1.0-0.06 1/2 05 G15.09 0.066-0.66 - - 0.31-3.1 0.14-1.4 0.14-1.4-0.07 06 G15.12 0.1-1.0 - - 0.49-4.9 0.2-2 0.2-2 - 0.09 07 G16.08 0.16-1.6 - - 0.7-7 0.35-3.5 0.35-3.5-0.09 08 G16.12 0.26-2.6 - - 1.5-10 0.6-5.6 0.6-5.6-0.10 09 G17.08 0.42-4.2 - - 1.7-17 0.88-8.8 0.88-8.8-0.10 10 G17.12 0.66-6.6 - - 2.8-28 1.0-10 1.0-10 - 0.12 11 N18.07 1-10 0.66-6.6 0.34-3.4 5.3-53 2.1-21 2.8-28 1.7-17 0.13 12 N18.09 1.6-16 1-10 0.6-5.8 7.7-77 3.3-33 4.2-42 2.4-24 0.13 13 N18.13 2.6-26 1.6-16 0.92-9.2 11-105 5.3-53 6.3-63 4.2-42 0.13 1/2 14 N19.09 4.2-42 2.6-26 1.4-14 17-175 7.7-77 9-90 6.3-95 0.19 15 N19.13 6.6-66 4.2-42 2.2-22 28-280 11.5-115 15-155 9-95 0.23 16 N19.19 11-105 6.6-66 3.7-37 - - - - 0.30 17 N19.26 17-165 11-105 6-60 - - - - 0.40 18 N21.09 17-165 11-105 6-60 63-630 31-310 39-390 25-245 0.32 1 19 N21.13 26-260 17-165 9.3-93 99-990 49-490 63-630 42-420 0.33 20 N21.18 45-420 26-260 16-150 - - - - 0.38 21 N21.25 66-660 45-420 25-250 - - - - 0.48 22 N41.09 45-420 26-260 16-150 160-1590 77-770 100-980 63-630 0.46 1-1/2 23 N41.13 66-660 45-420 24-240 250-2470 130-1270 160-1590 100-980 0.55 24 N41.19 105-1050 66-660 40-400 - - - - 0.55 25 N51.10 105-1050 66-660 40-400 425-4230 200-1975 250-2470 160-1590 0.62 2 26 N51.15 160-1585 105-1050 63-630 670-6700 320-3175 380-3880 250-2470 0.68 27 N51.21 265-2645 160-1585 93-930 - - - - 0.80

Table 4: Fittings 13 = Female NPT thread 316 stainless steel 33 = Female NPT thread, PVDF AB = 150 LB ANSI flange, 316 stainless steel LL = Tri-clamp connection, 316 stainless steel (N/A for ranges 1-10) Table 5: O-ring Materials 1=NBR 2 = FKM 4 = FFKM (N/A for ranges 1-10) A = EPDM (std on Tri-Clamp ver.) Table 6: Options 0 = None 1 = 5 point calibration report 2 = 10 point calibration report H = Cleaned and tagged for oxygen service S = 316 Stainless steel union nut in place of painted aluminum (standard on Tri-Clamp version) Accessories (order as separate line items) Part Number KDV-TG21 KDV-MS141 Description Adjustable NAMUR Proximity Switch (2 Max. for range codes 18 through 27 only) Adjustable Bistable Reed contact (2 Max. for range codes 11 through 27 only) KDV Series Floats and Measuring Tubes The KDV Series measuring tubes are manufactured from heat tempered borosilicate glass to resist cracking and failure in rough environments The KDV measuring tubes are available with scales delivered with any measuring units desired. Calibration for compressed gas and viscous liquids is standard. This allows the user to take accurate measurements with no field correction of readings. Complete the KDV series application datasheet in order to completely specify your flowmeter. Floats are available in several materials including stainless steel, Hastelloy and PTFE to suit nearly any application. All floats are notched on the upper guide rim to provide a stable reading.

Dimensions S2 14.75 16.73 14.75" Approximate Weights Meter Size Threaded/ ANSI Flange Tri-Clamp 1/2 1.0 LB/0.5 KG 4.0 LB/1.8 KG 1 2.9 LB/1.3 KG 8.4 LB/3.8 KG 1-1/2 5.0 LB/2.3 KG 15.0 LB/6.8 KG 2 8.0 LB/3.6 KG 20.2 LB/9.2 KG

KDV - Series Flowmeters Application Guide KDV Series Flowmeters Customer Name: Application Guide Form # KDV-001 Company Name: Rev. 3/12 FAX to: Phone: KOBOLD Instruments Inc. 412-788-4890 (USA) 514-428-8899 (Canada) Fax: Quote #: Date: Price: Each Part Number: Calibrated Measuring Range: * To ensure fast order processing, please retain the completed quote form and send it along with your purchase order. Design Conditions Accurate design pressure and temperature are essential to ensure the flowmeter will be built to operate without damage. Please fill out accurately and completely. List Design Conditions 1. Pressure: Maximum PSIG 2. Temperature: Maximum F Calibration Conditions: Accurate calibration conditions are required to ensure that the flowmeter will be factory calibrated to give accurate readings at the user s normal operating conditions. Please fill out accurately and completely. Calibration Conditions for Liquid Flow Applications 1. Type of Liquid: 2. Normal Operating Temperature: F 3. Viscosity at Normal Operating Temp: 4. Specific Gravity at Normal Operating Temp: 5. Desired Measuring Range and Units: Note: Items 3 & 4 not required for water flow Calibration Conditions for Gas Flow Applications 1. Type of Gas: 2. Normal Operating Temperature: F 3. Normal Pressure at Outlet Fitting: PSIG 4. Specific Gravity (required for gas mixes only): 5. Desired Measuring Range and Units: Note: The calibration pressure required is the pressure that the meter sees at its outlet fitting. Version: KDV-V (NPT Threaded) KDV-F (Flanged) KDV-A (Tri-Clamp) Float Materials: 316 SS Polypropylene PTFE Clad Hastelloy B2 PTFE Hastelloy C4 O-ring Material: NBR FKM FFKM EPDM Body Size: 1/2 1 NPT 1-1/2 2 Fittings: Thread 316 SS 150 LB ANSI 316 SS 5 NPT Thread PVDF Tri-Clamp Options: Point Cal. Cert. O2 Cleaning 10 Point Cal. Cert. 316 SS Union Nuts Switches: None 1 2 Reed Switch NAMUR Switch