AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES

Similar documents
Breathing Air Purifiers. Comply with European Pharmacopoeia and International Breathing Air Standards

Breathing Air Purifiers Comply with European Pharmacopoeia and International Breathing Air Standards ENGINEERING YOUR SUCCESS.

Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards

Breathable Compressed Air

Respiratory Protective Equipment

A. Evaluation of the written program

Niltox Breathing Air Purifier Range

OPERATING INSTRUCTIONS

F4001 & F4001ED SAFE-AIR TESTER OPERATING MANUAL

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL

F4000 & F4000ED SAFE-AIR TESTER OPERATING MANUAL

Respiratory Protection Self-Inspection Checklist

SR307 supplied air regulator Copyright 2013 by The S.E.A. Group 1

OPERATION MANUAL MPV-627 AIR FED HALF MASK

OPERATION MANUAL MPV-623 AIR-FED VIZOR

Respiratory Protection

Aerotest Breathing Air Systems

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

Breathing apparatus. Compulsory Specification for. Published by Government Notice No. R. 370 (Government Gazette 25040) of 20 March 2003

Contaminated Air in Cylinders By Ronny J. Coleman

Respiratory Protection Self Inspection Checklist

SR63 supplied air hood Copyright 2013 by The S.E.A. Group 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

Respiratory Protection in Agriculture

Respiratory Protection Program 29CFR

Working in Gas Hazard Areas

B-Series. breathing air systems flow capacity: scfm

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

East Brunswick Fire District #1

Food additive for stock foods (ALL HOURS)

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

Moisture levels in compressed breathing air. Prepared by QinetiQ Limited for the Health and Safety Executive 2006 RESEARCH REPORT 427

ANSI / ASSE Z88.2 American National Standard Practices for Respiratory Protection (1992 rev. versus 2015 rev.)

Respiratory Protection Programs Policy

SOUTH AFRICAN NATIONAL STANDARD

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

AIRLINE-SERIES HELMET AIR FILTER

Aerotest Breathing Air Systems

F4501 & F4501ED SAFE-AIR TESTER OPERATING MANUAL

F4500 SAFE-AIR TESTER OPERATING MANUAL

SAFETY DATA SHEET PRODUCT NAME Sulfur hexafluoride 1.2 RELEVANT IDENTIFIED USES OF THE SUBSTANCE OR MIXTURE AND USES ADVISED AGAINST :

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

CONTENTS. 9. Opening of gas systems containing H 2 S. 1. Introduction. 8. Protection of Personnel.

Respiratory Protection for Producers

Operate Breathing Apparatus

Toolbox Talk. Carbon Monoxide

Label 2.2: Non-flammable, Non-toxic gas 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

F4504 MULTI-AIR TESTER OPERATING MANUAL

D Lightweight Respiratory Protection

PRODUCT OPERATING MANUAL

Compressed Air - Food/Bev. Presented By: Adam Zimmerman

BREATHE SAFELY: The Proper Use of Respiratory Protection

G9 Arbour Grove Office Park 10 Oppenheimer Road Amanzimtoti, Durban,4120. Hazardous ingredients : PETROLEUM BASED HYDROCARBON OIL >99.

SAFETY DATA SHEET Page 1 of 6 KLINGER K55

PPE: RESPIRATORY PROTECTION EQUIPMENT

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

800.Keen.Gas

Selecting Respirators and Associated Equipment Monthly webinars from AFS- PROPOSED SCHEDULE

Personnel Protective Equipment

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

(MPV-625) 8 AIR SUPPLIED RESPIRATOR

Compressed Airline Breathing Apparatus

MATERIAL SAFETY DATA SHEET. Section 1: Identification. Section 2: Hazard Identification. Section 3: Hazard Identification

DATA SHEET Revised edition no : : Non flammable, non toxic gas. : Listed in Annex IV / V REACH, exempted from registration.

Astro Sandblast Helmet

Material Safety Data Sheet (MSDS)

Material Safety Data Sheet

AIR QUALITY. Safety is in the Air AVOIDING CARBON MONOXIDE POISONING WHILE SCUBA DIVING

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

CertainTeed. Spray Foam Insulation Safety Guidelines

SIG SOUTHERN INDUSTRIAL GAS SDN BHD

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET Page 1 of 7 KLINGERsoft-chem

CleanAIR ARES CA-83. welding leather hood. Contents. 1 General information 2 Use 3 Technical specification 4 Maintenance 5 List of parts 6 Approvals

INSTRUCTION MANUAL & PARTS

SAFETY DATA SHEET (SDS)

F6000 SAFE-AIR TESTER OPERATING MANUAL

Symptoms relating to use: Symptoms of over exposure to vapours are sore throat, cough, shortness of breath, headache.

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

Forced or Mechanical Ventilation - which uses mechanical supply and/or extraction to provide fresh air and is controllable.

Material Safety Data Sheet

PARFIX PVA ADHESIVE (ALL HOURS)

MATERIAL SAFETY DATA SHEET Page 1 of 7 KLINGER Thread Seal Tape

SAFETY DATA SHEET (91/155/EC) IDENTIFICATION OF THE SUBSTANCE /

Material safety data sheet Complying the (CE) 1907/2006 (REACH) regulation

Material safety data sheet Complying the (CE) 1907/2006 (REACH) regulation

Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater

MATERIAL SAFETY DATA SHEET. : Palm Kernel Expeller

SAFETY DATA SHEET GAS MIXTURES ARGON 75% CARBON DIOXIDE 25%

SAFETY DATA SHEET Page 1 of 7 KLINGER Sealex Joint Sealant

SAFETY DATA SHEET EVO-STIK FOAM FILLER

Breathable Compressed Air

SAFETY. Scuba air quality. By Francois Burman. Part 1: What do the limits really mean? 14 Alert DIVER.

Transcription:

AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES 1 of 1

Introduction Supplied air breathing apparatus systems require a breathable compressed air source to feed the equipment. The quality of breathing air supplied by compressors will vary considerably and has the potential to cause anything from minor health symptoms to a fatality, so it is crucial to have an understanding of compressed air systems and the demand for good quality. Growing awareness of the issues have resulted in the introduction of standards to control air quality fed to respiratory equipment users in Europe, USA and Australia. Compressed air supplied equipment is used in a variety of industries such as tank cleaning, shotblasting, paint spraying, mechanical works, nuclear decontamination and diving work. Factors influencing compressed air quality The quality of air generated by a compressor will depend on 2 key factors: The compressor system, including its drying and filtration system The quality of the air that is drawn in by the compressor 1. Compressor system Compressors operating at high temperatures which are too high, can produce Carbon Monoxide/ Dioxide. Inadequate filtration - filtration should be designed and specified for Breathing Air use. Filtration is not properly maintained. Operating temperature of the compressed air - filter efficiency diminishes with increased temperature to the point it may not be effective at all, so air should be cool enough to effectively filter. Improper filter media, which is not designed for breathing purposes, can result in changing the balance of gases in normal air, such as heightened oxygen. Breathing damp air will result in poor health symptoms, such as colds, sore throats or more serious conditions such as pneumonia. Too much water in the compressed air system can cause freezing especially where air passes through the small passages of valves and regulating devices, which can result in their malfunctioning. Exhaust gases generated by the compressor - for diesel or petrol compressors precautions should be taken to ensure that the exhaust gases are not drawn into the air intake. 2. The quality of the air drawn in by the compressor The quality of air drawn in may be affected by the general environmental conditions high humidity, high temperature air will be more of a challenge to air quality. Artificial or local conditions air will be degraded by exhaust fumes and other contaminants which surround the compressor. 1 of 2

Breathing Air Standards Please note: the below is guidance only taken from the full standards the full standards should be referred to if necessary. Region Europe US Australia and New Zealand Relevant BS EN12021 & CGA G-7.1-2011 AS-NZS 1715: 2009* Standard EN12021:2014 Grade D Odour The gas shall be free from unsatisfactory odour or taste None (No pronounced odour) No objectionable or nauseous odour Oxygen (21 ± 1)% 19.5% - 23.5% 19.5% - 22% Carbon 500 PPM 1000 PPM 800 PPM Dioxide Carbon 5 PPM 10 PPM 10 PPM Monoxide Oil 0.5 mg/m 3 5 mg/m 3 1 mg/m 3 Water Airline <40Bar Water High Pressu re Where the apparatus is used and stored at a known temperature the pressure dewpoint shall be at least 5 C below likely lowest temperature. Where the conditions of usage and storage of any compressed air supply is not known, the pressure dewpoint shall not exceed -11 C. 40 to 200 bar 50 mg/m 3 >200 bar 35 mg/m 3 HP Charging Comp 25 mg/m 3 Dewpoint 50 F (67 PPM v/v), for SCBA use in extreme cold a dew point not to exceed -65 F (24 ppm v/v) or the dewpoint must be 10 F lower than the coldest temperature where the respirator is worn. Contain no more than 100 mg/m 3 for cylinders initially filled to pressure of at least 120 bar. Equipment for testing Air Quality There is a variety of equipment available for testing air quality, but it is important to establish that the equipment will cover the tests required by the standard. Some equipment will measure gases but not water vapour or dewpoint. Some equipment is designed to perform a test at a point in time, where other equipment is designed to monitor real time constantly. Equipment may use a variety of technology including thermo desorption tubes (eg Draeger tubes), electrochemical sensors, and infra red sensors. Some laboratories will provide analysis of a collected sample also. 1 of 3

How often should air quality be tested? Compressed air should be tested to ensure it meets the required standards. Mobile breathing air systems according to the COSHH Regulations state that siting a compressor is critical, and air quality is tested where it is sited and whenever it is moved. In the UK the COSHH Regulations state that breathing air should be tested at least once every 3 months or more regularly if the reliability is questionable. With a high pressure system, the air quality is dependent on regular filter changes so many systems will have a mechanism to indicate filter change built in to the compressor. Testing regularity should be performed also according to risk assessment - where reliability of equipment is poor. Records should be kept of each test, these may be hard or soft copy and should be retained for a minimum of 5 years. Limitations of the standards The standards deal with the basic requirements for breathable air quality. However, it is possible that air can be contaminated with a variety of other toxics which may not be detected by the equipment used for testing. For example, the main toxic constituent in diesel fumes is Nitrogen Dioxide, which is not specifically required to be tested under the standards and which is not detected by all test equipment. Plants may have a high risk of other toxics being released to atmosphere which can in turn be drawn in by the compressor s intake. 1 of 4

References EN12021.2014 Respiratory Protective Devices Compressed Air for Breathing Apparatus EN529.2005 Respiratory Protection Devices COSHH Regulations.2002 HSG53: Respiratory Protective Equipment at work: A Practical Guide For further information on breathing air compressors or equipment for testing air quality please contact Breathe Safety Ltd, 0844 915 1111 or sales@breathesafety.com 1 of 5