BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

Similar documents
TSS21 Sealed Thermostatic Steam Tracer Trap

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

DF1 and DF2 Diffusers

AVM7 Stainless Steel Thermostatic Air Vent

CVS10 Sanitary Check Valves

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

TP1 and TP2 Temporary Cone Shaped Strainers

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

PV4 and PV6 Piston Valves

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

AVC32 Carbon Steel Air Vent for Steam Systems

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

Dri-Line Mk3 Monnier Compressed Air Drain Trap

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

DCV6 Disc Check Valve

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

CS10-1 Stainless Steel Clean Steam Separator

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

CP10 Sensor Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

BPT13 Balanced Pressure Thermostatic Steam Traps

S and SF Inverted Bucket Steam Traps

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

CA44, CA44S, CA46 and CA46S Air and Gas Traps

SRV66 Sanitary Pressure Reducing Valve

MF2M Monnier Miniature Compressed Air Filter

Airodyn, BRair and BRoil Compressed Air Drain Traps

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

PC10HP Pipeline Connector (ASME 600)

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

Spirax Compact FREME Flash Recovery Energy Management Equipment

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

MFP14-PPU (Vented) Automatic Packaged Pump Units

Manual Actuated Boiler Blowdown Valves

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

APT14, APT14HC and APT14SHC Spares 2

ML3M Monnier Miniature Compressed Air Lubricator

CA10S, CA14 and CA14S Air and Gas Traps

SRV2S Pressure Reducing Valve

SCA Series Inverted Bucket Steam Traps

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

BDV1 and BDV2 Blowdown / Depressurisation Valves

Thermocirc Installation and Maintenance Instructions

TW Temperature Control Valve

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

BCV31 DN40 - Blowdown Control Valve

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

Vane Flow Switches Colima FLU Series

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

BCV31 DN20 - Blowdown Control Valve

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

QuickHeat TM Packaged Heat Exchanger Solutions

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

BRV71 and BRV73 Pressure Reducing Valves

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

M111 Spiraflo Transducer

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

BCVi43 Blowdown Control Valve

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

BDV60 Blowdown Vessel Installation and Maintenance Instructions

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

595-K/L and 596-K/L Series Self Operated Valves Installation and Maintenance Instructions

Colima TOR Magnetic Level Switches

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

BSA and BSAT Bellows Sealed Stop Valves Installation and Maintenance Instructions

STD Spray Type Desuperheater

Transcription:

1800350/6 IM-P180-12 ST Issue 6 BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Operation 6. Spare parts and Maintenance Copyright 2013 IM-P180-12 ST Issue 6 1 Printed in GB

1. Safety information Safe operation of this product can only be guaranteed if it is properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.1 Intended use Referring to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended use / application. This product complies with the requirements of the European Pressure Equipment Directive 97 / 23 / EC and carries the mark when so required. The product falls within the following Pressure Equipment Directive categories: Product Group 2 Group 2 Gases Liquids BT6HC SEP SEP i) This product has been specifically designed for use on steam, air or condensate / water, which is in Group 2 of the above mentioned Pressure Equipment Directive. The products use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v) Remove protection covers from all connections and protective film from all nameplates, where appropriate, before installation on steam or other high temperature applications. 1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 2 IM-P180-12 ST Issue 6

1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are turned on and off in a gradual way to avoid system shocks. 1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and / or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and / or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high / low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. 1.12 Handling Manual handling of large and / or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. IM-P180-12 ST Issue 6 3

1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature of some products may reach temperatures of 300 C (572 F). Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to 'Maintenance instructions'). 1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. 4 IM-P180-12 ST Issue 6

2. General product information 2.1 General description The Spirax Sarco BT6HC is a high capacity thermostatic steam trap designed to remove condensate from hygienic and sanitary steam systems with minimal backing up. Applications include sterile steam barriers, process vessels and CIP/SIP sytsems. Manufactured in 316L stainless steel with a crevis free body, it is self-draining and operates close to steam temperature. Traps are individually packaged with protective end caps and sealed in a polythene bag. Surface finish All internal wetted surfaces have a finish of 0.8 µm (32 micro-inch Ra). External surfaces (excluding the clamp) have a surface finish of 1.2 µm (47 micro inch Ra). Surface finish of 0.4 µm (16 micro-inch Ra) can be supplied on request by electro-polishing. Options Electro-polishing of internal surfaces to 0.4 mm (16 micro-inch RA). Special connections to suit most piping systems. Standards The BT6HC fully complies with the ASME BPE, where applicable. It also complies with the requirements of the European Pressure Equipment Directive 97/23/EC. All wetted parts of this trap are manufactured from FDA/3-A approved materials. Certification The product is available with material certification to EN 10204 3.1 for the body if requested at the time of order placement. Note: For further information see the following Technical Information Sheet, TI-P180-13. 2.2 Sizes and pipe connections Suitable for installation using a 1" or 1½" sanitary clamp compatible hygienic connections. Fig. 1 BT6HC IM-P180-12 ST Issue 6 5

2.3 Pressure / temperature limits Temperature C Pressure psi g 0 20 40 60 80 100 120 177 150 100 50 Steam saturation curve 300 200 100 Temperature F 0 0 2 4 6 8 10 Pressure bar g The product must not be used in this region. The product should not be used in this region as damage to the internals may occur. Note: For hygienic / sanitary clamp ends the maximum pressure / temperature may be restricted by the gasket or sanitary clamp used. Please consult Spirax Sarco. Body design conditions PN10 PMA Maximum allowable pressure 10 bar g @ 140 C (145 psi g @284 F) TMA Maximum allowable temperature 177 C @ 9.2 bar g (350 F @ 133 psi g) Minimum allowable temperature -254 C (-425 F) PMO for Maximum saturated operating steam pressure service 6 bar g (87 psi g) TMO Maximum operating temperature 165 C @ 6 bar g (329 F @ 87 psi g) Minimum operating temperature 0 C (32 F) Designed for a maximum cold hydraulic test pressure of: 15 bar g (218 psi g) 6 IM-P180-12 ST Issue 6

3. Installation Note: Before actioning any installation observe the 'Safety information' in Section 1. Refering to the Installation and Maintenance Instructions, name-plate and Technical Information Sheet, check that the product is suitable for the intended installation: 3.1 Check materials, pressure and temperature and their maximum values. If the maximum operating limit of the product is lower than that of the system in which it is being fitted, ensure that a safety device is included in the system to prevent overpressurisation. 3.2 Determine the correct installation situation and the direction of fluid flow. 3.3 All packaging and protective covers are to be removed from the trap and its connections, including the internal element support prior to installation. 3.4 The trap is designed to be installed in vertical lines with the flow downwards so that it can be completely self-draining. Check the flow direction arrow on the body for the correct orientation. Sanitary clamp fittings and gaskets are to be supplied by the installer. Do not expose the element to superheat conditions as over expansion may result. This may occur if the trap is removed before it is cool or if fast acting isolation valves depressurise the pipework. Note: The BT6HC must be allowed to cool to ambient temperature, prior to CIP operation. 3.5 Installation in horizontal pipes will not allow self-draining and may cause wear on the seat / valve. 3.6 General considerations: The body and element must be handled carefully to ensure that the machined surfaces are not damaged. Care must be taken not to puncture the element or expose it to temperatures in excess of 177 C (350 F). Dispose of the sealed element in a safe manner. Note: If the trap is to discharge to atmosphere ensure it is to a safe place, the discharging fluid may be at a temperature of 100 C (212 F). 4. Commissioning After installation or maintenance ensure that the system is fully functioning. Carry out tests on any alarms or protective devices. IM-P180-12 ST Issue 6 7

5. Operation The operating element is a capsule containing a small quantity of a special liquid with a boiling point below that of water. In the cold conditions that exist at start-up, the capsule is relaxed. The valve is off its seat and is wide open, allowing unrestricted removal of air. This is a feature of all balanced pressure traps and explains why they are well suited to air venting. As condensate passes through the balanced pressure steam trap, heat is transferred to the liquid in the capsule. The fill liquid boils before steam reaches the trap. The vapour pressure within the capsule causes it to expand and the trap shuts. Heat loss from the trap then cools the water surrounding the capsule, the fill condenses and the capsule contracts, opening the valve and releasing condensate until steam temperature approaches again at which the cycle is repeated. During CIP operations the trap will be fully open to allow maximum flow of the cleaning fluid. On steam start-up the trap will remain open until all air and incondensibles are purged from the system. Under normal operating conditions the operation of the trap will depend on the steam pressure, capacity and location. Typically the trap will begin to open at approximately 3 C (5.4 F) below steam saturation temperature at the trap inlet. 6. Spare parts and Maintenance Note: Before actioning any maintenance observe the 'Safety information' in Section 1. 6.1 Spare parts The available spare parts are detailed below: Available spare Element assembly 2 How to order spares Always order spares by using the description given in the column headed 'Available spare' and state the size, model number and pressure rating of the trap. Example: 1 - Element assembly for a Spirax Sarco 1" BT6HC balanced pressure steam trap. 6.2 How to replace the element assembly: - Before undertaking any maintenance on the trap it must be isolated from both supply line and return line and any pressure allowed to safely normalise to atmosphere. The trap should then be allowed to cool. - Undo the sanitary clamp fittings and remove the trap from the pipeline. - Remove the element assembly and replace with a new one. - Replace the trap in the pipeline together with the required gaskets and retighten the sanitary clamp fittings to the manufacturers' specified torque. Fig. 2 2 8 IM-P180-12 ST Issue 6