Research Article Incidence and Outcomes of Anterior Chamber Gas Bubble during Femtosecond Flap Creation for Laser-Assisted In Situ Keratomileusis

Similar documents
EVERY TREATMENT IS A TRUE ORIGINAL

LASIK Wavefront Guided idesign LASIK with IntraLase

SMILE for low Myopia

OPESAVER Super Irrigation System

How images are formed in the eye

LENS EXCHANGE WITH IMPLANTATION OF A BITORIC INTRAOCULAR LENS IN EYES WITH SIGNIFICANT ASTIGMATISM AFTER PREVIOUS CORNEAL SURGERIES

THE TOP 100 KEYWORDS FOR AN

INTRASTROMAL CORRECTION OF PRESBYOPIA AND CLINICAL APPLICATION WITH TECHNOLAS FEMTOSECOND LASER

A life without glasses or contact lenses

Getting Started GUIDE LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. TECNIS TORIC 1-PIECE IOL pg 1

12.15 CORNEAL REFRACTIVE SURGERY (PRK/LASEK/LASIK/SMILE)

Ophthalmology Clinical Pearls A Quick Guide To Crystalens

POLYMACON HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE

Research Article Effects of Walking Direction and Cognitive Challenges on Gait in Persons with Multiple Sclerosis

Investigation of Winning Factors of Miami Heat in NBA Playoff Season

Training Guide STAR S4 IR Excimer Laser

Orthokeratology. What is Orthokeratology? How does it work?

Fitting Guide. Minutes-to-Fit 2.0. by SynergEyes Moving Vision Forward

GROUND REACTION FORCE DOMINANT VERSUS NON-DOMINANT SINGLE LEG STEP OFF

5.1 Introduction. Learning Objectives

Corrective Lens Use and Refractive Error Among United States Air Force Aircrew

Analysis of Variance. Copyright 2014 Pearson Education, Inc.

PENTICTON FIRE DEPARTMENT AUXILIARY FIRE FIGHTER INFORMATION PACKAGE

CLINICAL SCIENCES. Michael Goggin, FRCSI(Ophth), MS; Sacha Moore, FRCOphth; Adrian Esterman, AStat, PhD

LENSTAR LS 900 Setting the standard in optical biometry

Research Article An Investigation of the Basic Physics of Irrigation in Urology and the Role of Automated Pump Irrigation in Cystoscopy

Chapter 5: Methods and Philosophy of Statistical Process Control

APPROACH RUN VELOCITIES OF FEMALE POLE VAULTERS

V E J A R A N O P R O T O C O L FOR T H E M A N A G M E N T O F Q U E R A T O C O N O SURGICAL T I PS

Accommodation responses and refractive error

Pre- and postoperative refraction after cataract extraction with implantation of standard power IOL

Sound scattering by hydrodynamic wakes of sea animals

ITTC Recommended Procedures and Guidelines

b. Provide consultation service to physicians referring patients. c. Participate in weekly wound care clinic and biweekly diving medicine clinic.

Zebrafish Fin Regeneration Virtual Experiment

Impact of Demographic Characteristics on USASF Members' Perceptions on Recent Proposed Rule Changes in All Star Cheerleading

In November 1998, the Staar AA4203 toric intraocular. Early rotational stability of the longer Staar toric intraocular lens. Fifty consecutive cases

OTM Patent Coordinator. Biomedical and Health Information Sciences Lauren Segal Anne Burkhart Architecture, School of Mark Krivchenia Anne Burkhart

DETERMINATION OF THE DEPTH OF CLOSED BLIND CRACKS IN NON-METAL CHECK SAMPLES AND TEST PANELS FOR PENETRANT TESTING

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Prediction of Nearshore Waves and Currents: Model Sensitivity, Confidence and Assimilation

Financial Disclosures Toric IOL Selec-on and Posi-oning

SECTION 2 HYDROLOGY AND FLOW REGIMES

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

Safety Assessment of Installing Traffic Signals at High-Speed Expressway Intersections

Ultrasound Dose Calculations

Dr. Thomas R. Reim President, DreimLens, Inc.

Injector system for implantation of 1stQ foldable intraocular lenses

Standard Recommended Practice. Field Measurement of Surface Profile of Abrasive Blast-Cleaned Steel Surfaces Using a Replica Tape

Directed self-assembly of microcomponents enabled by laser-activated

For decades, surgeons worldwide have worked to improve

1001 West Broadway, Vancouver, BC V6H 4B1. Topical Finasteride

Basic Concept & Techniques of Phaco Prechop

AN EXPERIMENTAL INVESTIGATION OF SPILLING BREAKERS

How Running Barefoot (Xero Shoes) and Running Shod (Montrail Shoes) Effects Percent of Maximum Heart rate - A Case Report

Learn Connect Succeed. JCAHPO Regional Meetings 2017

23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN APRIL 2007

ifs Advanced Femtosecond Laser System

KINEMATIC ANALYSIS OF SHOT PUT IN ELITE ATHLETES A CASE STUDY

Walking with coffee: when and why coffee spills

Figure 2: Principle of GPVS and ILIDS.

Offshore platforms survivability to underwater explosions: part I

SUGGESTED POLICY FOR THE MONITORING OF THE CLEANING EFFICIENCY OF AN ULTRASONIC CLEANERS( SONIC & TOSI) WEEKLY

Test Method of Trap Performance for Induced Siphonage

CALIBRATION OF THE PLATOON DISPERSION MODEL BY CONSIDERING THE IMPACT OF THE PERCENTAGE OF BUSES AT SIGNALIZED INTERSECTIONS

Clinical Study Synopsis

Keywords: dynamic stall, free stream turbulence, pitching airfoil

Use a Controlled Vibration to Mixing and Separation of a Gas Bubbles and a Liquid Under Reduced and Microgravity Conditions

Orthotics, Casts, and Crutches: What is Practical?

Analysis of recent swim performances at the 2013 FINA World Championship: Counsilman Center, Dept. Kinesiology, Indiana University

Wind Flow Validation Summary

Waves. Kevin Small or

AERODYNAMIC CHARACTERISTICS OF SPIN PHENOMENON FOR DELTA WING

Currents measurements in the coast of Montevideo, Uruguay

Scleral Fitting Guide

Cabrillo College Transportation Study

University of Pennsylvania Institutional Review Board. Reliance Agreement Guidance: Post-Approval Submissions

Hyperbaric Oxygen and TBI: What Does Science Tell Us. Kathleen Bell, MD Department of Rehabilitation Medicine

CONTINUING REVIEW CRITERIA FOR RENEWAL

An investigation of the variability of start-up lost times and departure headways at signalized intersections in urban areas

b

AIRMOUNT VIBRATION ISOLATION

International Journal of Innovative Research in Advanced Engineering (IJIRAE) ISSN:

Elements for a Public Summary. Overview of disease epidemiology

LABORATORY EXPERIMENTS FOR WAVE RUN-UP ON THE TETRAPOD ARMOURED RUBBLE MOUND STRUCTURE WITH A STEEP FRONT SLOPE

PROJECT REPORT TITLE OF PROJECT:

How Running Barefoot (Xero Shoes) and Running Shod (Montrail Shoes) Effects Percent of Maximum Heart rate - A Case Report

OPTIMIZATION OF INERT GAS FLOW INSIDE LASER POWDER BED FUSION CHAMBER WITH COMPUTATIONAL FLUID DYNAMICS. Abstract. Introduction

Procedia Engineering Procedia Engineering 2 (2010)

b

Introduction to Analysis of Variance (ANOVA) The Structural Model, The Summary Table, and the One- Way ANOVA

NormalEyes Guidelines For Successful Fitting RIGID GAS PERMEABLE SCLERAL CONTACT LENSES. Manufactured in Paragon HDS 1OO (paflufocon D)

REPORT. A comparative study of the mechanical and biomechanical behaviour of natural turf and hybrid turf for the practise of sports

Alternate Suction to Reduce Prolonged Air Leak

Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge

High Speed Direct SAD Radiosurgery Beam Scanner

Acknowledgments. Paragon Vision Sciences Adoption of CRT certification slide for this generic talk. Material Considerations

PACKAGE INSERT RIGID GAS PERMEABLE CONTACT LENSES FOR ORTHOKERATOLOGY. (hexafocon B)

Understanding How the Appearance of Optical Fiber Splices Relates to Splice Quality

QUARTERLY REPORT NO. 3 DE-FG22-94PC /01/95

Transcription:

Ophthalmology Volume 2015, Article ID 542127, 4 pages http://dx.doi.org/10.1155/2015/542127 Research Article Incidence and Outcomes of Anterior Chamber Gas Bubble during Femtosecond Flap Creation for Laser-Assisted In Situ Keratomileusis Sloan W. Rush, 1,2 Philip Cofoid, 2 and Ryan B. Rush 1,2,3 1 Panhandle Eye Group, 7400 Fleming Avenue, Amarillo, TX 79106, USA 2 Texas Tech University Health Sciences Center, 1400 S. Coulter, Amarillo, TX 79106, USA 3 Southwest Retina Specialists, 7411 Wallace Boulevard, Amarillo, TX 79106, USA Correspondence should be addressed to Ryan B. Rush; ryanbradfordrush21@hotmail.com Received 22 February 2015; Revised 31 March 2015; Accepted 4 April 2015 Academic Editor: Marco Lombardo Copyright 2015 Sloan W. Rush et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Purpose. To report the incidence and outcomes of anterior chamber gas bubble formation during femtosecond laser flap creation for laser-assisted in situ keratomileusis (LASIK). Methods. The charts of 2,886 consecutive eyes that underwent femtosecond LASIK from May 2011 through August 2014 were retrospectively reviewed. The incidence, preoperative characteristics, intraoperative details, and postoperative outcomes were analyzed in subjects developing anterior chamber gas bubble formation during the procedure. Results. A total of 4 cases (0.14%) developed anterior chamber gas bubble formation during femtosecond laser flap creation. In all four cases, the excimer laser was unable to successfully track the pupil immediately following the anterior chamber bubble formation, temporarily postponing the completion of the procedure. There was an ethnicity predilection of anterior chamber gas formation toward Asians (p = 0.0055). An uncorrected visual acuity of 20/20 was ultimately achieved in all four cases without further complications. Conclusions. Anterior chamber gas bubble formation during femtosecond laser flap creation for LASIK is an uncommon event that typically results in a delay in treatment completion; nevertheless, it does influence final positive visual outcome. 1. Introduction Cavitation gas bubbles are an expected phenomenon during femtosecond laser flap creation for laser-assisted in situ keratomileusis (LASIK) [1, 2]. An opaque bubble layer (OBL) is a well-known intraoperative finding on various femtosecond laser platforms [3, 4]. In rare instances, the OBL may temporarily preclude pupillary tracking during the excimer laser portion of the femtosecond LASIK procedure [5]. Bubbles that are confined to the corneal stromal bed may disperse rapidly, and there are manual surgical techniques that may expedite their dissipation [6]. Some femtosecond laser platforms have designed a venting canal incision at the hinge of the flap to facilitate the release of the cavitation bubbles external to the lamellar cutting plane in order to negate the formation of a OBL [7]. In contrast to the OBL in the corneal stroma, there have been only a few case reports in which there was formation of a gas bubble inside the anterior chamber [8, 9]. By comparison, anterior chamber gas bubbles may not absorb as promptly as stromal bed OBL and can potentially inhibit the excimer laser from adequately tracking the pupil [10]. Various mechanisms have been hypothesized to describe the occurrence of anterior chamber gas bubbles [11, 12], but little is known regarding their incidence, risk factors, clinical significance, and intraoperative/postoperative consequences. In this study, we describe the incidence, baseline characteristics, and postoperative outcomes in subjects developing anterior chamber gas bubble formation during femtosecondlaserflapcreationduringlasik. 2. Methods An institutional review board [13] approved this retrospective, consecutive chart review that included all patients from

2 Ophthalmology May 2011 through August 2014 that received femtosecond laser flap creation for LASIK at a single center, Rush Eye Associates, located in Amarillo, TX, USA. All research components adhered to the tenets of the Declaration of Helsinki and were conducted in accordance with human research regulations and standards. 2.1. Inclusion/Exclusion Criteria and Data Collection. The operative eyes of all patients that underwent femtosecond LASIK on the Wavelight FS200 femtosecond laser and the Allegretto Wave Eye-Q 400 Hz excimer laser platforms (Alcon, Fort Worth, TX, USA) by a single surgeon (SWR) during the aforementioned study interval were included. For all cases in which anterior chamber gas bubble formation occurred, the baseline characteristics, intraoperative details, and postoperative outcomes were collected. The baseline characteristics included subject gender, age, ethnicity, preoperative uncorrected visual acuity (UCVA), preoperative best spectacle corrected visual acuity (BSCVA), and preoperative manifest refraction spherical equivalent. The intraoperative details included femtosecond laser settings, pupil tracking ability, anterior chamber gas bubble characteristics and pattern of OBL formation, and the occurrence of any other surgical complications. The postoperative outcomes included UCVA, BSCVA, and manifest refraction spherical equivalent at2weeksand2months,aswellastheoccurrenceofanyother complications during the postoperative period. 2.2. Femtosecond Laser Settings. The following laser settings hadbeenprogrammedfortheflapcreationinallstudy subjects: Bed Cut Energy = 0.8 μj, Bed Cut Spot Separation = 8.0 μm, Bed Cut Line Separation = 8.0 μm, Side Cut Energy = 0.8 μj,sidecutspotseparation=5.0μm, Side Cut Line Separation = 3.0 μm, Vent Canal Power 0.85 μj, and Vent Canal Width = 1.5 mm. All patients had a 9.0 mm flap diameter with a 70 side cut angle. The flap depth ranged from 100 to 110 μm and varied based upon the patient s preoperative corneal thickness measurements. 2.3. Statistical Analysis. TheJMP11mathematicalsoftware package from the SAS Institute (Cary, NC, USA) was used to perform the statistical analysis and calculate means with standard deviations. Since the study population is relatively small compared to the frequency of the event being studied, the two-tailed Fisher s exact test was used when comparing the distributions. Results were considered statistically significant at the alpha < 0.05 level. 3. Results A total of 2,886 subject eyes were included in the analysis. The mean age of the overall study population was 37.4 (±11.9) years with 55% female and 45% male. There were a total of 4eyesoffourdifferentpatientsinwhichanteriorchamber gas bubble formation occurred (incidence = 0.14%). All four cases were females with a mean age of 29.3 (±10.2) years, two of which were Asian and two of which were Caucasian. When comparing Asian eyes (90 total) versus non-asian eyes (2,796 total) there was a statistically significant difference Figure 1: Anterior chamber gas bubble formation during femtosecond laser flap creation for LASIK. Femtosecond laser scout view of the cornea immediately after the femtosecond laser treatment. Note the small anterior chamber bubbles in the upper left-hand corner of the image (black arrow) as well as the 360-degree ring of opaque bubble layer that dissected toward the peripheral cornea until termination at Schwalbe s line (white arrow). (p = 0.0055). All four patients were myopic, and the mean preoperative refractive spherical equivalent in this small subset of patients was 6.1 (±2.4) diopters, but there was no statistical correlation among formation of anterior chamber gas bubble and the preoperative refractive error (p = 0.3063). The mean average keratometry value was 43.8 (±1.7 diopters) for the entire population versus 43.7 (±1.1) diopters for the patients that developed anterior chamber gas bubble, and the mean pachymetry value was 537.9 (±24.6) microns for the entire population versus 539.0 (±16.5) microns for the patients that developed anterior chamber gas bubble formation, neither of which significantly differed (p = 0.9955 and p = 0.9288,resp.). The anterior chamber gas bubble was noted to occur during the lamellar cut in all instances and was immediately preceded by a 360-degree peripheral lamellar ring of deep OBL that dissected near the location of Schwalbe s line (see Figure 1). No cavitation bubbles were noted to evacuate through the venting canal incision in any of these cases. The flap depth treatment was 110 μm inallfourinstances.the Allegretto Wave Eye-Q 400 Hz excimer laser pupil tracking device was unable to adequately track the pupil so that no immediate attempt was made to lift the flap in any of these patients. One case required postponement of the excimer laser portion of the treatment until the following day, while three cases required a delay until later on during the same day (range: 4 6 hours), two of which still had a solitary miniscule bubble (<0.5 mm) remaining during the excimer laser treatment. All four cases were ultimately able to have successful pupil tracking and excimer laser treatment. During the postoperative period, there were 72 cases in which the flap was lifted for retreatment due to over- or undercorrection (incidence of 2.49%), 3 cases of flap striae that required refloating of the flap on the first postoperative day (incidence of 0.10%), 2 cases of central toxic keratopathy (incidence of 0.10%), and 1 case of epithelial in-growth (incidence of 0.03%) in the study population. None of these postoperative complications occurred in the subset

Ophthalmology 3 of patients that experienced anterior chamber gas bubble formation. All eyes that had anterior chamber gas bubble formation during the procedure achieved UCVA of 20/20 postoperatively at 2 weeks and 2 months, and no eyes lost any lines of BSCVA. There were no postoperative infections occurring during the study period. 4. Discussion To our knowledge, this is the first study to evaluate anterior chamber gas bubble formation during femtosecond LASIK. The findings of this study suggest that anterior chamber gas bubble formation may be of little consequence to postoperative refractive outcomes and may not predispose to further complications during or after the completion of the femtosecond LASIK procedure. Nevertheless, formation of anterior chambergasbubblesislikelytocausedelayinthetreatment and can potentially lead to increased patient apprehension, inconvenience, and anxiety. In view of the favorable refractive outcomes ultimately achieved in this study, we recommend surgeon patience and patient reassurance in the event of this rare intraoperative occurrence. Procedural observations during this study lead the investigators to hypothesize that cavitation bubbles dissecting across a lamellar plane in close proximity to Schwalbe s line may, in certain circumstances, gain retrograde access to the anterior chamber through the trabecular meshwork via Schlemm s canal. This hypothesis of trabecular entry has been previously supported with video evidence by Soong and de Melo Franco [12]. Although our overall study population only contained 3.1% Asian eyes, the number of Asian eyes with anterior chamber gas bubble formation during femtosecond laser flap creation was found to be statistically significant (p = 0.0055). The authors recognize that an ethnicity correlation with anterior chamber gas bubble formation during femtosecond laser flap creation has not been reported by previous studies and that this correlation must be evaluated by future studies with even larger numbers, particularly in Asian populations, before a valid conclusion can be made. More research is needed to further elucidate both the mechanism of anterior chamber gas bubble formation during femtosecond laser flap creation and specific patient factors that predispose to this infrequent event. Weaknesses of this study include the retrospective nature of data collection and the limited number of cases for such an evidently rare occurrence. The investigators caution that a different femtosecond laser platform besides the one used in this study, or different laser settings than those used in this study, could have clinically different rates of anterior chamber gas bubble formation as well as postoperative outcomes. Future investigations may validate or refute the findings in this report, further characterize the circumstances in which bubble formation occurs, and investigate various femtosecond laser settings in which the incidence of anterior chamber gas bubble formation during femtosecond laser flap creation is decreased or eliminated altogether in the setting of LASIK. Conflict of Interests The authors declare that they have nil presentations, nil financial support, and nil financial or proprietary interest. Authors Contribution Sloan W. Rush and Ryan B. Rush designed and conducted the study; Sloan W. Rush and Philip Cofoid performed collection, management, analysis, and interpretation of the data; and SloanW.Rush,RyanB.Rush,andPhilipCofoidprepared, reviewed, or approved the paper. References [1] T.Juhasz,G.A.Kastis,C.Suárez,Z.Bor,andW.E.Bron, Timeresolved observations of shock waves and cavitation bubbles generated by femtosecond laser pulses in corneal tissue and water, Lasers in Surgery and Medicine, vol. 19, no. 1, pp. 23 31, 1996. [2]S.R.Aglyamov,A.B.Karpiouk,F.Bourgeois,A.Ben-Yakar, and S. Y. Emelianov, Ultrasound measurements of cavitation bubble radius for femtosecond laser-induced breakdown in water, Optics Letters, vol. 33, no. 12, pp. 1357 1359, 2008. [3] V. Hurmeric, S. H. Yoo, J. Fishler, V. S. Chang, J. Wang, andw.w.culbertson, In vivo structural characteristics of the femtosecond LASIK-induced opaque bubble layers with ultrahigh-resolution SD-OCT, Ophthalmic Surgery, Lasers & Imaging,vol.41,no.6,pp.S109 S113,2010. [4] A.J.KanellopoulosandG.Asimellis, Essentialopaquebubble layer elimination with novel LASIK flap settings in the FS200 Femtosecond Laser, Clinical Ophthalmology, vol. 7, pp. 765 770, 2013. [5] I. Kaiserman, H. S. Maresky, I. Bahar, and D. S. Rootman, Incidence, possible risk factors, and potential effects of an opaque bubble layer created by a femtosecond laser, Cataract and Refractive Surgery,vol.34,no.3,pp.417 423,2008. [6] C.-H. Liu, C.-C. Sun, D. Hui-Kang Ma et al., Opaque bubble layer: incidence, risk factors, and clinical relevance, Cataract and Refractive Surgery, vol.40,no.3,pp.435 440, 2014. [7] A. J. Kanellopoulos and G. Asimellis, Digital analysis of flap parameter accuracy and objective assessment of opaque bubble layer in femtosecond laser-assisted LASIK: a novel technique, Clinical Ophthalmology,vol.7,pp.343 351,2013. [8] T. Lifshitz, J. Levy, I. Klemperer, and S. Levinger, Anterior chambergasbubblesaftercornealflapcreationwithafemtosecond laser, Cataract and Refractive Surgery,vol.31,no. 11, pp. 2227 2229, 2005. [9] S. Srinivasan and D. S. Rootman, Anterior chamber gas bubble formation during femtosecond laser flap creation for LASIK, Refractive Surgery, vol. 23, no. 8, pp. 828 830, 2007. [10] S. Srinivasan and S. Herzig, Management of anterior chamber gas bubbles during IntraLASIK, Ophthalmic Surgery Lasers and Imaging,vol.41,no.4,pp.482 484,2010. [11] C. A. Utine, M. Altunsoy, and D. Basar, Visante anterior segmentoctinapatientwithgasbubblesintheanteriorchamber after femtosecond laser corneal flap formation, International Ophthalmology,vol.30,no.1,pp.81 84,2010.

4 Ophthalmology [12] H. K. Soong and R. de Melo Franco, Anterior chamber gas bubbles during femtosecond laser flap creation in LASIK: video evidence of entry via trabecular meshwork, Cataract &RefractiveSurgery,vol.38,no.12,pp.2184 2185,2012. [13] SRS Institutional Review Board, (IORG0007600/ IRB00009122).

MEDIATORS of INFLAMMATION The Scientific World Journal Gastroenterology Research and Practice Diabetes Research International Endocrinology Immunology Research Disease Markers Submit your manuscripts at BioMed Research International PPAR Research Obesity Ophthalmology Evidence-Based Complementary and Alternative Medicine Stem Cells International Oncology Parkinson s Disease Computational and Mathematical Methods in Medicine AIDS Behavioural Neurology Research and Treatment Oxidative Medicine and Cellular Longevity