What I ve Learned About Dam Safety Good, Bad and Ugly

Similar documents
ANNUAL INSPECTION BY A QUALIFIED PROFESSIONAL ENGINEER ALL CCR IMPOUNDMENTS CCR Rule Section (b)

STRUCTURAL STABILITY ASSESSMENT

USING A LABYRINTH WEIR TO INCREASE HYDRAULIC CAPACITY. Dustin Mortensen, P.E. 1 Jake Eckersley, P.E. 1

D.B. Wilson Station CCR Landfill

ANNUAL INSPECTION BY A QUALIFIED PROFESSIONAL ENGINEER ALL CCR IMPOUNDMENTS CCR Rule Section (b)

APPENDIX C VEGETATED EMERGENCY SPILLWAY. VERSION 1.0 March 1, 2011

Northern Indiana Public Service Company Michigan City Generating Station Primary Settling Pond Number Annual RCRA CCR Unit Inspection Report

Whitewater Valley Station Surface Impoundment Coal Combustion Residual Annual Report

Emergency Action Plans for Dam Safety

Huntington District. For More Information Contact (304)

Hard Hat Services ph: hardhatinc.com 932 N. Wright St., Suite 160 Naperville, IL 60563

La Crescent Township Zoning Ordinance

Plan B Dam Breach Assessment

COAL COMBUSTION RESIDUAL (CCR) FUGITIVE DUST CONTROL PLAN

Green CCR Surface Impoundment

HISTORY OF CONSTRUCTION

CLOSURE PLAN. CFR (b) GERS Bottom Ash Pond. Northeastern 3&4 Power Station Oologah, Oklahoma. October, 2016

INFILTRATION PRACTICE MAINTENANCE INSPECTION FORM

BSR GPTC Z TR GM References and Reporting Page 1 of 8

VIRGINIA SOIL AND WATER CONSERVATION BOARD GUIDANCE DOCUMENT ON DAM BREAK INUNDATION ZONE AND INCREMENTAL DAMAGE ANALYSIS AND MAPPING PROCEDURES

In this presentation we will talk about Florida Administrative Code, 64E-9 and how it regulates swimming pools and pool operator s responsibilities.

Earthen Embankments. turning into larger, more costly repairs. The following. The State Dam Safety Program has inspection

GSA POLICY ON LOCAL EXHAUST AND OTHER VENTILATION (FUME CUPBOARDS)

COAL COMBUSTION RESIDUAL (CCR) FUGITIVE DUST CONTROL PLAN

Information Bulletin No. IB February 22, 2018 TYPE: INTERPRETATION

DAM SAFETY GUIDELINES 2007

Water Discharge Best Management Practices [G-0613] Pool & Hot Tub Council of Canada May 2013

Hard Hat Services ph: hardhatinc.com 932 N. Wright St., Suite 160 Naperville, IL 60563

Flood Preparedness and Response

Emergency Action Plan

Attached as Exhibit B-2 is BC Hydro's presentation from the Stave Falls Spillway Gates Project Workshop held on January 18, 2010.

Suitable Applications Check dams may be appropriate in the following situations: To promote sedimentation behind the dam.

CCR Certification: Fugitive Dust Control Plan (b) for the. West Ash Pond. at the. F. B. Culley Generating Station.

Dam Breach Inundation Analysis

Annex E Bridge Pier Protection Plan

UNDERWATER BRIDGE INSPECTION REPORT DISTRICT 8 - LAC QUI PARLE COUNTY

Distribution Restriction Statement Approved for public release; distribution is unlimited.

Initial Annual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1

Annual CCR Landfill Inspection. Lansing Landfill. Interstate Power and Light Company. Prepared for:

HERBERT HOOVER DIKE REHABILITATION PROJECT

REVISION RECORD. Revision Number. Date Sections Affected/Reason 0 04/17/2017 Creation of Initial EAP

USACE Participation in High Hazard Dam Evaluations in Hawaii Following the 2006 Kaloko Dam Failure

Hard Hat Services ph: hardhatinc.com 932 N. Wright St., Suite 160 Naperville, IL 60563

UNDERWATER BRIDGE INSPECTION REPORT DISTRICT 8 - LAC QUI PARLE COUNTY

Coal Combustion Residuals Closure Plan

REVISION RECORD. Revision Number. Date Sections Affected/Reason 0 04/17/2017 Creation of Initial EAP

New Castle County Guidelines for the Certified Construction Reviewer, Owner/Developer, Site Contractor and Professional Engineer

2016 Annual Inspection Report

CCR Closure Plan. CCR Certification: Written Closure Plan (b) & (c) for the. Landfill Sedimentation Pond. A. B. Brown Generating Station

October 16, GRDA CCR Landfill Compliance Report Grand River Dam Energy Center 8142 Hwy 412B PO Box 609 Chouteau, OK Dear Mr.

Notice of Intent to Close Inactive CCR Surface Impoundments

CCR Landfill 2017 Annual Inspection Report NC1 Ash Disposal Area

Sediment Basin 7E-12. Design Manual Chapter 7 - Erosion and Sediment Control 7E - Design Information for ESC Measures BENEFITS.

Chadbourne Dam Repair and Fish Barrier

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine

RIIWMG203D Drain and Dewater Civil Construction Site Learner Guide

PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO LOW LEVEL LIGHT UNITS

PIQCS HACCP Minimum Certification Standards

ROAD SLOPE MANAGEMENT IN MALAYSIA

O&M MANUAL HIGHLIGHTS

Emergency Preparedness and Response plan

Interim Guidance Fish Presence Absence

Water Storage for Agriculture

E-3: Jurisdictional Determination Supplement Report

Installation of Traffic Signals and Pedestrian Crossings

Permit-Required Confined Space Entry Program

PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO HIGH LEVEL LIGHT UNITS

OPERATION OF SPILLWAY GATES HOW TO AVOID THE PROBLEMS AND PITFALLS. Peter Allen. DERM Qld

then extrapolated to larger area just based on the length of bank [that actually falls in this category].

FAIRWAY PALMS II CONDOMINIUM PROPERTY

The Best Use of Lockout/Tagout and Control Reliable Circuits

Annual Inspection Report of CCR Impoundment and CCR Landfill Wenck Project # B

CLOSURE PLAN. CFR (b) Bottom Ash Pond Complex Cardinal Plant Brilliant, Ohio. September, 2016

TABLE OF CONTENTS 1.0 INTRODUCTION PLAN CERTIFICATION (B)(4) 1

COAL COMBUSTION RESIDUALS FUGITIVE DUST CONTROL PLAN

FISH PASSAGE IMPROVEMENT in California s Watersheds. Assessments & Recommendations by the Fish Passage Forum

DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management

2016 Annual Inspection Report

Evaluation of June 9, 2014 Federal Emergency Management Agency Flood Insurance Study for Town of Weymouth, Norfolk, Co, MA

Kootenai River Habitat Restoration Program. Kootenai Tribe of Idaho - January 27, 2014 Presentation for Kootenai Valley Resource Initiative

Technical Report Culvert A Hydraulic Analysis

Title: Degreasing-Aqueous

U.S. ARMY CORPS OF ENGINEERS INSTITUTE FOR WATER RESOURCES RISK MANAGEMENT CENTER PRELIMINARY LESSONS LEARNED FROM OROVILLE INCIDENT

The University of Georgia Automated External Defibrillator (AED) Program Guidelines

Annual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1

CONTROL OF HAZARDOUS ENERGY IN THE WORKPLACE

2018 Annual Inspection Report

Ways to Meet OSHA Requirements for Safety Signage

General Inspection Guidance for Waste Management Units Requiring Air Emission Controls Under RCRA Air Standard Subpart CC

PROCESS HAZARD ANALYSIS FOR THE SEPTIC TANKS AND SYSTEMS REMOVALS AT BUILDING 4005, 4009 AND 4100.

SOP 407: PROTOCOL DEVIATIONS AND UNANTICIPATED PROBLEMS

Guidance Note. Hydropower Guidance Note: HGN 8 Fish Passage. When do you need to install a fish pass?

MAINTENANCE AND SAFETY OF CNG REFUELLING STATIONS

Understanding safety life cycles

Standbys. (Owner: Risk Management Section Supervisor)

Designing Labyrinth Spillways for Less than Ideal Conditions Real World Application of Laboratory Design Methods

PRESSURE SYSTEMS POLICY

UNDERWATER BRIDGE INSPECTION REPORT DISTRICT 1 PINE COUNTY

INTERIM ADVICE NOTE 171/12. Risk Based Principal Inspection Intervals

Significant Change to Dairy Heat Treatment Equipment and Systems

Transcription:

What I ve Learned About Dam Safety Good, Bad and Ugly Ron Gruzesky Dam Safety and Floodplain Compliance Kentucky Division of Water Department for Environmental Protection August 26, 2015

What is a Dam?

What is a Dam?

What is a Dam? Minimum of 25 feet in height measured from the downstream toe to the top of the dam - or - Impounds 50 acre-feet of water, measured at the top of dam - or - Small but poses a hazard to life or property.

Kentucky Dam Safety Law and Regulation KRS 151.100, Definitions KRS 151.125, Authority and Powers of Secretary KRS 151.250, Permits KRS 151.280, KRS 151.310, Violations KRS 151.292, State-owned Dams KRS 151.293, Certificate of Inspection KAR 401 (4:030), Design Criteria KAR 401 (4:060), Stream Construction Criteria

Kentucky Dam Safety Guidance The following are guidance documents and may be found at: www.water.ky.gov. Engineering Memorandum No. 5- summarizes design criteria Rainfall Frequency Values-required values for hydraulic evaluation Geotechnical Guidelines for Earthen Dams General Discussion of Dam Breach Analysis

Hazard Classification Classifications are Low, Moderate and High. Based on the potential consequences of failure. Independent of condition and quality of the dam. Hazard Classification can change as the consequences of failure change. (Downstream land use changes)

Low Hazard Dam Potential damage limited to: Loss of dam Loss of livestock, farm out-buildings, Ag land Little used roads Loss of life unlikely 629 of these in Kentucky

Moderate Hazard Dam Potential damage limited to: Industry or commercial buildings Moderately traveled roads or railroads Interruption to utilities or public water supplies Loss of life unlikely 153 of these in Kentucky

High Hazard Dam Failure may cause a threat to, or loss of, human life. Failure may result in serious damage to: Residential, industrial or commercial areas Public utilities or buildings; major transportation facilities 181 of these in Kentucky

Hazard Classification Change When downstream conditions change, hazard classification can change. DOW cannot control downstream development. Dam breach flood often exceeds the 100-year flood. Local ordinances can prevent some development.

Hazard Class Change Due to Development

Hazard Classification Change Dam Safety may require upgrades or removal if the dam does not meet requirements for the current hazard classification. Upgrades may include lowering the normal pool elevation, raising the dam, or enlarging the spillway. Dam removal may be the cheapest alternative and must be done in a controlled manner.

Emergency Action Plans Emergency Action Plans can save lives if the unthinkable happens to a dam. 2:00 AM in the middle of a raging thunderstorm isn t the time to discover that you don t know what to do or who to call.

Emergency Action Plans Identify failure modes. Include inundation maps, warnings and evacuation plans. List critical personnel and phone numbers. Requires training and exercise to be successful.

Emergency Action Plans Get the location of high and moderate hazard dams in your area. Become familiar with the structures and their history of problems. Check the area below the dam for low-lying buildings and roads. Be prepared to act quickly. If something doesn t look right it probably isn t.

Permits for new dams Required when: Height of dam > 25 feet from downstream toe to top of dam Top of dam storage > 50 acre-feet Dam will pose a potential for loss of human life Dam is built across stream as defined by KRS 151

Permits for existing dams Required when: Modification or alteration is beyond the scope of routine maintenance. Change in operating procedures. Change in spillway height or dimensions. Conditions of permit may require meeting all current criteria for existing dams.

Dam Inspections Dam Safety Inspects: High Hazard and Moderate Hazard dams every 2 years. Low Hazard Dams every 5 years. Summary report, letter sent to owner, filed.

Dam Inspections Generally take from 45 minutes to an hour. Inspectors look for: Embankment items: stability, vegetation, rodent burrows, erosion, seepage. Principle spillway: debris, seepage, corrosion, cracking. Emergency spillway: vegetation, erosion, debris. Ability to operate drains. Downstream development.

Action for Unsafe Dams Dam Safety may issue a Notice of Violation requiring the owner to repair, upgrade, or remove the dam. The EEPPC Secretary may issue an Emergency Order to drain the lake and breach the impoundment at the owner s expense. These are not popular or common actions.

Inspection Modernization Migrating to a geo-referenced database. Streamlines data entry through the use of tablets. Increases data consistency by using dropdown menus. Automated upload of data improves data integrity.

Coal Combustion Residuals New rule was published in the Federal Register. We are writing a regulation to implement in conjunction with the Solid Waste Branch. Won t require many changes to dams, but many of these surface impoundments will have to close or retrofit.

The L Word Levee No federal program No state program Many were designed for one purpose, but now being used for another

Exhaustive List of Levee Law and Regulation in Kentucky KRS 151.250, Permits

Questions?