Process gas requirements (Core, VWI, and OptiMix gas connect consoles)

Similar documents
Optimizing Gas Supply for Industrial Lasers

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Visit our Web site: http: //

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

PRESSURE CONTROL REGULATORS

Safe Work Instructions For Oxygen Acetylene Equipment

V-24 OXYGEN LANCE VALVE

Gas Welding Hoses and connections, the weak link

HyDefinition HD4070. Plasma Arc Cutting / Marking System. Product Configuration Manual Revision

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Compressed Gases Storage and Handling Safety Policy. Individual Unit Function: Safety Procedure No.: SOP-0103 Page: 1 of 6

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

Working Environment Safety Assessment

OXYGEN & ACETYLENE: Safety & Handling for these Highly Combustible Gases

PERMA-CYL 230/450/1000/1500/2000. Installation Manual Manual # Revision B

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT

Safety, Set-Up, and Operating Instructions

A guide to Part 10 of the

INSTRUCTIONS FOR SCORPION TORCHES

OPERATION MANUAL NTF-60 Plus

SAFETY DIRECTIVE 3.0 REFERENCES. 3.1 See Appendix B

oxyacetylene welding/cutting torch set

This training does not attempt to cover all safety regulations or precautions.

Laboratory Safety Committee

MEDICAL EQUIPMENT CATALOG

SAFETY AND OPERATION MANUAL

Chiyoda's High-Pressure Gas Control System and Equipment

CUTTING TORCH SAFETY. The Safe Use and Handling of OXY Fuel Cutting, Welding, and Heating Equipment

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

OPERATION MANUAL NTF-15

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

Wilkins Safety Group

BRITISH COMPRESSED GASES ASSOCIATION Registered office: 4a Mallard Way, Pride Park, Derby, UK. DE24 8GX Company Number: 71798, England

BCGA GUIDANCE NOTE GN 23

BRAZING & CUTTING. Kits Easy To Use

THE DELIVERY OF GAS SUPPLY

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Compressed Gas Cylinder Safety

Pressure Regulators. Operating Instructions. Instrumentation

Bauman Machine Inc. COMPRESSED GAS CYLINDER SAFETY

Cutting and shaping materials using thermal cutting equipment

HIND MEDICO PRODUCT (AN ISO 9001:2008 CERTIFIED COMPANY)

CHAPTER 26 WELDING AND CUTTING

Oxy-Fuel Safety Training. Participant s Guide

Build Your Own Flamethrower Step-by-step Manual

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

CNC Communication Protocol

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

NITROGEN GENERATOR Tradition Trail Plano, Texas 75093

Operating Instructions Plasma 60/100P

How Flashback Arrestors Work

NGN Series nitrogen generator

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

BUBBLE MUFFLER SYSTEM

HT4400 Plasma Arc Cutting System Gas Panel

Purge Star & Ring Purge Systems

SAFETY BULLETIN 01/05

plasmarc air curtain For use with m3 Plasma System and PT-36 Plasma Torch ESAB Assembly Number: Instruction Manual gas the bottom of the plate.

PARTS, SERVICE & REPAIR BULLETIN

Genuine. Kit includes: This kit contains CIGWELD s Genuine COMET 700 Oxygen and Acetylene Regulators, Blowpipe and Cutting Attachment.

CUT OFF TOOL MODEL: CAT113

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

Jerry Martin s Co 2 Snow Apparatus

Customer Responsibilities

APPS-160 Gen 2 User Manual

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

632 Series Gas Distribution System

COMPANY HEALTH & SAFETY PROGRAM. Title: Welding & Cutting Section No: 45

HiQ laboratory gas generators.

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

WHAT IS GAS TANK/CYLINDER?

SEMFWE3-33 SQA Unit Code HF2X 04 Cutting and shaping materials using portable thermal cutting equipment

Doc No: WELDHOT Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Typical Single Stage Design SR 450 Series Shown. Two stage regulators add the following in addition to the features listed above:

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Compressed Gas Cylinders - Guideline

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

INSTRUCTION MANUAL. Models: OX2550KC WK5500OX DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

ASSEMBLY & OPERATIONS MANUAL. Straight & Clean Torch Cuts. Every Time.

HEAVY-DUTY AIR RATCHET WRENCH OWNER S MANUAL

Welding, Cutting, and Brazing

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

WELDING AND CUTTING GUIDELINES

Foundations of Agriculture

NEW Edge Series Products: OUTFITS and REGULATORS

M3060 Handling Compressed Gas Cylinders Safely. Leader s Guide

MODULE 2 BRAZING CYLINDER TRANSPORT, STORAGE AND EQUIPMENT

KENNECOTT UTAH COPPER CORPORATION SAFETY AND HEALTH STANDARDS COMPRESSED GAS

// ADapters GUIDelines

CUTTING AND WELDING TORCHES HANDLES

fig.1 Instructions for: Gas welding/cutting kit

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

ACCU-PULSE Installation and Operation Instructions

WELDING & CUTTING FIRE PROTECTION SAFETY 1 NAVFAC

Transcription:

Process gas requirements (Core, VWI, and OptiMix gas connect consoles) You must supply the process gases and supply gas plumbing for your cutting system. See Table 7 on page 46 for supply gas quality, pressure, and flow requirements. Gas leaks or pressure and flow rates that are outside of recommended ranges can: Cause problems with system performance Result in bad cut quality Shorten the life of consumables If the quality of the gas is bad, it can decrease: Cut quality Cut speed Cut thickness capabilities See Table 7 on page 46 for the recommended pressures and flow rates. Table 7 Gas quality, pressure, and flow requirements Gas* Quality Pressure Maximum flow rate O 2 (oxygen) 99.5% pure, clean, dry, oil-free** 70.83 slpm 150 scfh N 2 (nitrogen)*** 99.99% pure, clean, dry, oil-free 180.83 slpm 380 scfh Air**, Clean, dry, oil free consistent with 8573-1:2010 Class 1.4.2 118 slpm 250 scfh H 2 (hydrogen) 99.995% pure 50 slpm 105 scfh Ar (argon) 99.99% pure; clean, dry, oil-free 118 slpm 250 scfh F5 (95% nitrogen, 5% hydrogen) 99.98% pure 40 slpm 85 scfh * Water can be used as a shield fluid for XPR300 plasma power supplies that have a VWI or OptiMix gas connect console. See Shield water requirements (VWI and OptiMix) on page 49 for the specifications and requirements for water that is used for shield purposes. ** Air compressors must provide air that meets the ISO air specification. Important: Any air compressors that provide air to the cutting system must extract oil prior to air delivery. *** Nitrogen is required for all mild steel processes. Air is required for H 2 mix processes. 46 809480 Instruction Manual XPR300

2 Code conformity All customer-supplied equipment must meet applicable national and local codes for supply gas and supply gas plumbing. Contact a licensed plumber for more information about the codes in your location. Any installation, modification, or repair of supply gas equipment or plumbing systems must be done by a licensed plumber. Plumbing for supply gases WARNING If you use oxygen as the plasma gas for cutting, it can cause a potential fire hazard due to the oxygen-enriched atmosphere that collects. Hypertherm recommends that you install an exhaust ventilation system to remove the oxygen-enriched atmosphere that can collect when oxygen is used as the plasma gas for cutting. Flashback arrestors are required to stop the spread of fire to the supply gases (unless a flashback arrestor is not available for a specific gas or pressure). You must supply the flashback arrestors for your cutting system or you can get them from your cutting machine supplier. Hydrogen is a flammable gas that presents an explosion hazard. Keep flames away from cylinders and hoses that contain hydrogen. Keep flames and sparks away from the torch when using hydrogen as a plasma gas. Consult your local safety, fire, and building code requirements for the storage and use of hydrogen. Hypertherm recommends that you install an exhaust ventilation system to remove the hydrogen-enriched atmosphere that can collect when hydrogen is used as the plasma gas for cutting. Flashback arrestors are required to stop the spread of fire to the supply gases (unless a flashback arrestor is not available for a specific gas or pressure). You must supply the flashback arrestors for your cutting system. You can get them from your cutting machine supplier. You must install the supply gases and supply gas plumbing for your cutting system. You can use flexible hoses that are designed to carry the appropriate gas and are rated for the correct pressure. Other hoses can crack and leak. You can use rigid copper pipes. Do not use steel or aluminum. XPR300 Instruction Manual 809480 47

Supply-gas hoses are available from Hypertherm. (See Supply hoses on page 342.) All customer-supplied equipment must meet applicable national and local codes for supply gas and supply gas plumbing. Contact a licensed plumber for more information about the codes in your location. Hypertherm recommends an internal diameter of 10 mm (0.375 inch) for supply-gas hoses that are 76 m (250 feet) or less. Table 8 on page 48 describes the recommended sizes for gas fittings. Table 8 Recommended gas fitting sizes Fitting type N 2 / Ar Size 5/8 inch 18 RH, internal (inert gas) B Air 9/16 inch 19, JIC, #6 F5 / H 2 O 2 9/16 inch 18, LH (fuel gas) B 9/16 inch RH (oxygen) The location of regulators and the number of elbow fittings can have an effect on inlet pressure. If the inlet pressure for your cutting system is not within recommended specifications, contact your cutting machine supplier or regional Hypertherm Technical Service team. Never use PTFE tape on any joint preparation. All hoses, hose connections, and hose fittings used for supply gas plumbing must be designed for use with the appropriate gas and pressure rating. Other hoses, hose connections, or hose fittings can crack or leak. Some air compressors use synthetic lubricants that contain esters. Esters will damage the polycarbonates in the air filter bowl. 48 809480 Instruction Manual XPR300

2 Regulators for supply gases Do not use low-quality gas regulators. They do not provide consistent supply gas pressure. Low-quality gas regulators can also cause problems with system performance and decrease cut quality. Synthetic lubricants that contain esters (which are used in some air compressors) will damage polycarbonates used in the air filter bowl. You must supply the gas regulator for your cutting system. Choose a high-quality gas regulator that has the following characteristics: A 2-stage gas regulator that maintains consistent gas pressure with high-pressure gas cylinders or A 1-stage gas regulator that maintains consistent gas supply pressure with liquid cryogenic or bulk gas storage. For best results, position the gas regulator (or regulators) within 3 m (10 feet) of the gas connect console. Shield water requirements (VWI and OptiMix) Use of water as a shield fluid is optional. If you use water as a shield fluid, always use water that meets the specifications in Table 9 and Table 10. Table 9 Quality, pressure, and flow requirements for shield water (use is optional) Water type Quality* Minimum and maximum pressure Maximum flow rate required H 2 O Deionized water is not recommended to use as shield water. Hypertherm recommends a water softener if the water has a high mineral content. (See Table 10.) Water with high levels of particulates must be filtered. 2.76 bar (40 psi) minimum 7.92 bar (115 psi) maximum 35 L/h (9.4 US gal/h) * Water that does not meet minimum purity specifications can cause excessive deposits on the torch nozzle and shield. These deposits can alter the water flow and produce an unstable arc. XPR300 Instruction Manual 809480 49

Table 10 Purity measurement methods for shield water Methods to measure water purity Water purity level Conductivity μs/cm at 25 C (77 F) Resistivity mω cm at 25 C (77 F) Dissolved solids or hardness (ppm of NaCl) Grains per gallon (gpg of CaCO 2 ) Pure water (For reference only. Do not use.) 0.055 18.3 0 0 Maximum purity 0.5 2 0.206 0.010 Minimum purity 18 0.054 8.5 0.43 Maximum potable water (For reference only. Do not use.) 1000 0.001 495 25 Plumbing and hose requirements for optional shield water You must supply the plumbing and hoses for the shield water. You can use flexible hoses that are designed to carry water. You can use rigid copper pipes. Do not use steel or aluminum pipes. Install the plumbing and hoses consistent with all local and national codes. After installation, pressurize the entire system and test it for leaks. To decrease the risk of leaks in the cutting system, make sure to tighten all connections to the recommended torque specifications in Table 16 on page 108. Hoses are available from Hypertherm. (See Water (optional shield fluid) (blue) on page 344 of the Parts List.) Regulator requirement for optional shield water Internal water pressure regulators are built into the VWI and OptiMix gas connect consoles. External water pressure regulators are only required with the water pressure is above 7.92 bar (115 psi). 50 809480 Instruction Manual XPR300