OPERATING INSTRUCTIONS

Similar documents
tel: fax: web:

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES

OPERATING INSTRUCTIONS

HCMTCB ASPHALT CERTIFICATION KEY ELEMENTS LIST

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

Standard Test Method for Capillary-Moisture Relationships for Fine-Textured Soils by Pressure-Membrane Apparatus 1

Tex-227-F, Theoretical Maximum Specific Gravity of Bituminous Mixtures

Aug 17, 2001 LAB MANUAL MAXIMUM SPECIFIC GRAVITY (RICE VOIDS TEST) OF PAVING MIXTURES AASHTO Designation T 209 (Mn/DOT Modified))

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR SAND EQUIVALENT

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

Durham Geo-Slope Indicator S-510 Triaxial Cell

Pipette apparatus. Meet the difference. Manual. T E I

ASPHALT PLANT LEVEL 1

RESISTANCE OF COMPACTED ASPHALT MIXTURE TO MOISTURE INDUCED DAMAGE (Kansas Test Method KT-56)

Operating Instructions

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Operating Instructions

OP CHECKLIST FOR 1D CONSOLIDATION LABORATORY TEST

OPERATING INSTRUCTIONS

BULK SPECIFIC GRAVITY AND UNIT WEIGHT OF COMPACTED HOT MIX ASPHALT (HMA) (Kansas Test Method KT-15)

Method of Making and Curing Concrete Specimens in the Field for Compression and Flexural Tests

Standard Test Procedures Manual

Appendix A Preliminary SEMs

PANACEA P200 STAINLESS STEEL USER MANUAL

08.60 Pycnometer. operating instructions. All it takes for environmental research. Contents

SPECIFIC GRAVITY AND ABSORPTION OF AGGREGATE BY VOLUMETRIC IMMERSION METHOD

Soil water retention determination using the Wetlab facility at CSIRO, Davies Laboratory

7.9. Flash Column Chromatography Guide

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

Freeze-Thaw Effects and Gas Permeability of Utility Line Backfill

Vacuum Pycnometer BM705. Impact Test Equipment Ltd & User Guide. User Guide

. In an elevator accelerating upward (A) both the elevator accelerating upward (B) the first is equations are valid

In situ permeability measurement with the BAT Permeameter. Quick Manual Ou low test. Warranty details

FINAL REPORT INVESTIGATION OF TEST METHODS, PAVEMENTS, AND LABORATORY DESIGN RELATED TO ASPHALT PERMEABILITY

In situ permeability measurement with the BAT Permeameter. Quick Manual Inflow test. Warranty details

IN-PLACE DENSITY WAQTC FOP AASHTO T 209 (16)

Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA , United States.

Disassembling and assembling APP and APP 16-22

POWER FLUSH KIT INSTRUCTIONS

Commonwealth of Pennsylvania PA Test Method No. 742 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

PANACEA P125 USER MANUAL

MS.RAJA ELGADY/PRESSURE PAPER 3

VACUUM & AIRLESS. Select from Kimble vacuum traps, manifolds, Schlenk tubes, adapters, and bubblers for your vacuum and airless glassware needs.

ASPHALT WAQTC FOP AASHTO T 209 (12)

HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual

The SPI Sputter Coater Handbook

Owners Manual. Durham Geo-Enterprises,Inc. Triaxial Panel Phone: Fax: Web site:

Alan Davis Field Trip Activities

Geotechnical Engineering Laboratory CIVIL ENGINEERING VIRTUAL LABORATORY Experiment no 8 Standard Penetration Test

Soils for civil engineering purposes

Operating Instructions

METHOD OF TEST FOR THEORETICAL MAXIMUM RELATIVE DENSITY OF BITUMINOUS PAVING MIXTURES LS-264 R27 ASTM D2041/D2041M

PANACEA P100 LOW PRESSURE USER MANUAL

Density of Soils and/or Granular Material In-place by the Sand-Cone Method

AP Biology 12 Cellular Respiration Lab

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

Measuring Carbon Dioxide in Breath

SPECIFICATION FOR REPEATED LOAD TRIAXIAL (RLT) TESTING FOR PAVEMENT MATERIALS

OPERATING INSTRUCTIONS

Apr 16, 2010 LAB MANUAL 1810

Permeability. Darcy's Law

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8.

PLASTIC FINES IN GRADED AGGREGATES AND SOILS BY THE USE OF THE SAND EQUIVALENT TEST FOP FOR AASHTO T 176

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl

Oct 1, 2002 LAB MANUAL SPECIFIC GRAVITY & ABSORPTION of FINE AGGREGATE AASHTO Designation T 84 (Mn/DOT Modified)

Jan 10, 2002 LAB MANUAL

APP pumps APP and APP Disassembling and assembling

Thermochemistry/Calorimetry. Adiabatic coefficient of gases Flammersfeld oscillator LEC 02. What you need: What you can learn about

Density of Granular Material by Modified Sand-Cone Method for Thin Layers

Reinforce design of experiments theory Make individual factorial designs and conduct analysis on responses

Tex-416-A, Air Content of Freshly-Mixed Concrete by the Pressure Method

Tex-616-J, Construction Fabrics

Instruction Manual Updated 5/26/2009 Ver. 2.0

K-STATE GRAIN QUALITY RESEARCH PROGRAM STANDARD OPERATING PROCEDURES

IN-PLACE DENSITY AND MOISTURE CONTENT OF SOIL AND SOIL- AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) FOP FOR AASHTO T 310

Application and Sizing

ABRASIVE REGULATOR II

Experiment 18 Properties of Gases

AIR CONTENT OF FRESHLY MIXED CONCRETE BY THE PRESSURE METHOD (Kansas Test Method KT-18)

TECHNICAL BENEFITS OF CJS / RAISE HSP. Technical Advantages

DBML-60/80 Squeeze Tool

ABRASIVE REGULATOR II

EAS Basic Soil Gas Sampler

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

Soil Aggregate *Nominal Maximum Minimum Weight No. of Splits to Obtain Designation Sieve Size of Particle of Sample, Ibs Portion for Test


Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

PLASTIC FINES IN GRADED AGGREGATES AND SOILS BY THE USE OF THE SAND EQUIVALENT TEST FOP FOR AASHTO T 176 (11)

COLD WELD COPPER TUBE SAMPLING EQUIPMENT AND PROCEDURES

COMPACTING SPECIMENS USING THE TEXAS GYRATORY COMPACTOR (TGC) PART I COMPACTING SPECIMENS USING THE TGC. Test Procedure for

ASPHALT PLANT LEVEL 1

TAO Safety Policy No. HS-5.1 Page 1 of 15 Revision No. 2 Revision Date: July 19, 2005

QUIK-jet Micro-Injection System

Bottle Rocket Launcher P4-2000

Air Pycnometer. Operating Manual. Umwelt-Geräte-Technik GmbH

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

Determination of R: The Gas-Law Constant

Lab Session #4 AN Physical Properties

Transcription:

OPERATING INSTRUCTIONS Combination Permeameter ELE International Chartmoor Road, Chartwell Business Park Leighton Buzzard, Bedfordshire, LU7 4WG England phone: +44 (0) 1525 249200 fax: +44 (0) 1525 249249 email: ele@eleint.co.uk http://www.ele.com ELE International, a division of Hach Lange Ltd. Distributor: ELE International Soiltest Product Division PO Box 389, Loveland, CO 80539 USA phone: +1 (800) 323 1242 fax: +1 (970) 663 9781 email: soiltest@eleusa.com http://www.eleusa.com In the interests of improving and updating its equipment, ELE reserves the right to alter specifications to equipment at any time ELE International 2012 1 9907X0056 Issue 2

Contents Section Page 1 General Description 3 2 Preparation of Specimen and Test Procedure 3 2.1 Constant Head Test 3 2.2 Falling Head Test 5 2 9907X0056 Issue 2

1 General Description The Combination Permeameter is designed for the laboratory determination of permeability of either fine grained or coarse-grained soils. Generally soils containing 10% or more particles passing a No. 200 (75 micron) sieve are tested using the falling head assembly. More granular soils, containing 90% or more particles retained on a No. 200 (75 micron) sieve, are tested using the constant head assembly. The permeability chamber disassembles into two sections. The bottom section only is normally used for falling head tests. It will accommodate a sample up to 2½ inches (63.5 mm) in length. When greater flow is expected, as with the constant head test, the lower chamber disassembles from the base to allow for easy placement of undisturbed or remolded samples. Chamber diameter is 2½ inches (63.5 mm) (31.65 sq.cm. area). The unit is easily converted from falling head assembly and back in seconds. It is assumed that the Combination Permeameter will be used in a laboratory at controlled temperature conditions of 20ºC (68ºF). Temperature corrections for viscosity of water need not be considered unless temperature deviates by more than +/- 5ºC. 2 Preparation of Specimen and Test Procedure 2.1 Constant Head Test 3 9907X0056 Issue 2

2.1.1 Select a representative sample of air dried soil containing less than 10% of particles passing the No. 200 (75 micron) sieve and equal in amount to twice that required for filling the permeameter chamber (approximately 800 grams). 2.1.2 Mix sufficient moisture into the soil to prevent segregation of particles during placing into the permeameter. The water content should be such that the mixture just flows freely to form layers. 2.1.3 Remove the chamber cap and upper chamber from the unit by unscrewing the three knurled cap nuts and lifting the units off the tie rods. Position one porous stone on the support ring in the base of the chamber. 2.1.4 Using a scoop or funnel pour the prepared specimen in a circular manner into the lower chamber to a depth of 1.5cm so that a uniform layer is formed. Compact the layer of soil to the desired density, repeating the procedure until the sample is within 2cm (0.8 inch) of the top of the lower chamber section. 2.1.5 Replace the upper chamber section, being careful not to disturb the test specimen. Be sure to place the rubber gasket between chamber sections. Continue the sample placement operations until the level of compacted material is approximately 2cm (0.8 inch) below the top of the upper chamber. Carefully level the surface of the specimen and place the upper porous stone on the specimen. Place the compression spring on the porous stone, and replace the chamber cap and sealing gasket, securing it firmly with the cap nuts. The spring prevents change in sample length, measure and record the sample length. 2.1.6 Connect a vacuum pump or suitable aspirator to the outflow line at the top of the chamber. Assemble the constant head funnel and meter stick to the funnel rod using the special clamp provided. Adjust the constant head funnel to the desired height above the outflow port to create the desired head. Record the distance between funnel overflow port (the upper serrated fitting on the funnel) and the chamber outflow port. 2.1.7 Using a pinch clamp, seal the inflow tube at the bottom of the unit. Fill the constant head funnel with water from the source to be used while testing. (A constant flow of water into the funnel will be required.) Connect the water to lower serrated fitting. 2.1.8 Apply a vacuum of approximately 20 inches Hg (33.5 kpa) for fifteen minutes to remove trapped air in the specimen and from the voids. After evacuation, gradually open the pinch clamp and slowly allow the sample to saturate under full vacuum. Disconnect the vacuum pump when the chamber is filled with water. 2.1.9 Place a graduated cylinder to receive outflow from the chamber. Fully open and remove the pinch clamp from the inflow line and regulate the flow of water into the constant head funnel so that a stable condition with flow from both the funnel overflow port and chamber overflow line is achieved. 2.1.10 After equilibrium flow conditions are established, measure and record the time required for a given quantity of water to flow from the chamber. Record the water quantity. 4 9907X0056 Issue 2

2.1.11 Calculate the coefficient of permeability (K) using the following equation. K= QL or K= QL 31.65 th Ath K = Coefficient of permeability (cm per second) Q = Quantity of water discharge in ml L = Length of sample in cm t = Total time for discharge in seconds h = Vertical distance between funnel overflow and chamber outflow port in cm A = Area of cross section of specimen = 31.65cm 2 2.2 Falling Head Test 2.2.1 Select a representative sample of the material to be tested and compact it in the lower chamber section in layers to approximately 2cm (0.8 inch) below the chamber rim. 5 9907X0056 Issue 2

2.2.2 Remove the upper section of the chamber tie rods, place the upper porous stone on the specimen and secure the chamber head with spring to the unit. Measure and record the specimen length. 2.2.3 Attach the falling head burette to the support rod using the clamp. Position the burette as high as practical. Position the meter stick directly behind the burette, such that the height of water in the burette above the chamber overflow port may be read. Connect the bottom of the burette to inflow tube at bottom of chamber. 2.2.4 Using a pinch clamp, seal the chamber inflow tube near the inflow port and fill the burette with water. 2.2.5 Connect a vacuum pump or aspirator to the outflow line of the chamber. Evacuate the chamber and sample with a full vacuum for approximately 30 minutes. After evacuation, gradually open the pinch clamp and allow the sample to saturate, still under full vacuum. Disconnect the vacuum pump when the chamber is full of water. NOTE: During sample saturation be sure to keep the falling head burette filled with water above the plastic tubing. 2.2.6 Allow water to flow through the specimen until a constant flow condition is observed. Fill the burette to it s top graduation and record the height of water above the chamber outflow port and the date and time. Place a moist cotton stopper in the top of the burette to prevent evaporation. 2.2.7 Allow water to permeate through the sample until a minimum of 20 ml of flow has occurred. Record the flow in the height of the water column above the chamber outflow port, and the date and time. 2.2.8 Calculate the permeability (K) using the following equation K= al x Loge h0 a= Q At h1 h0 h1 Or K= 2.3aL x Log 10 h0_ At h1 K= 2.3QL x Log 10 h0_ 31.65t (h0 h1) h1 Or K= QL x Log 10 h0_ 13.76t (h0 h1) h1 K = Coefficient of permeability (cm per second) Q = Flow in ml L = Length of sample in cm T = Total time of flow in seconds h0 = Initial height of water column above chamber outflow port in cm h1 = Final height of water column above chamber outflow port in cm A = Area of cross section of specimen = 31.65cm 2 6 9907X0056 Issue 2