AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

Similar documents
CLEARWATER SERIES REVERSE OSMOSIS DESALINATOR INSTALLATION & OPERATION MANUAL

Installation and Service Manual

MP15 Jockey Pump Controller

FAULT CODE TROUBLESHOOTING INDEX

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Touch Screen Guide. OG-1500 and OG Part # T011

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Reverse Osmosis System Installation Guide and Operation Manual.

LENNOX SLP98UHV DIAGNOSTIC CODES

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

Burner Management System DEMO Operating instructions

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

RAM 4021-DPX Operation Manual

RAM 4021 Operation Manual

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

A4s Operation Manual

User s Information Manual

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

6800 Maintenance Instruction System Flush Procedure

OPERATION AND MAINTENANCE MANUAL

Portable Oil Lube Air Compressors

Instructions for Use

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

User Manual for the Mars Calibration Bench

444C DUAL PERFORMANCE VALUE PACK

BUBBLER CONTROL SYSTEM

MODEL NUMBER: P PORTABLE COMPRESSOR

RAM Operation Manual

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

400C & 450C DUAL PERFORMANCE VALUE PACKS

WATER CONTROL SYSTEM QUICK START

Roller AC Servo System

NIV EAU MATIC ST User Manual Made in Canada

OPERATION AND MAINTENANCE MANUAL

200 PSI FAST-FILL AIR SOURCE KIT

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

200 PSI HIGH-FLOW AIR SOURCE KIT

ACV-10 Automatic Control Valve

OPERATION AND MAINTENANCE MANUAL

Swimming Pool IAQUALINK WEB CONNECT

LSX Low Smoke Convertor Operations Manual

MODEL NUMBER: P PORTABLE COMPRESSOR

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Associated Hazard (outcome) Control Measures. Reduction of water supply

1020 Industrial Drive, Orlinda, TN fax

R E D I C O N T R O L S

Technical Service Bulletin March 2015 TSB142.01

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

accidents which arise due to non-observance of these instructions and the safety information herein.

SP-110 Autopilot OPERATION

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

SAFETY PRECAUTIONS FOR THE BLACK BEARD S BEACH WATER PARK

Quick Start Setup Instructions for Raven LRC & AgXcel Harness for NH3 Profile plus GX40 Synergist

OPERATION AND MAINTENANCE MANUAL

NGP-250/500 Nitrogen Generator Quick Start Guide

H. Control of Hazardous Energy: Lockout/Tag Out

Copeland Discus with CoreSense Diagnostics January 2011

200 PSI COMPRESSORS - MODEL NUMBERS

RH800 & 2000 BASIC OPERATIONS

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

100C Air Compressor Kit

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

955108_2. AirForce Operator s Guide

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

WARNING OLED & BASIC MENU QUICK START

Universal Valve Company Inc

Universal Valve Company Inc

CPF 270, CPF 340. Instruction book

THE UNIVENTOR 400 ANAESTHESIA UNIT

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

SAPCON. User Manual. Capacitance Continuous Level Indicator. . Introduction. . General Description. . Principle of Operation. .

KELCO F60 DIGITAL PUMP CONTROLLER

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

Remote Control Bait Boat

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

MPC-3000 INSTALLATION MANUAL

Portable Electric Desalinator Operation Manual Rainman Desalination

OPERATION MANUAL BFX-2

Using the UltraRAE. Firmware 2.35

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

Vessel Installation and Operating Manual

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS

AHE58/59 AC Servo System

MoveRoll Conveyor Operating and Maintenance Manual

Commandant United States Coast Guard

OPERATION AND MAINTENANCE MANUAL

Municipal Boost w/pre-treatment Monitoring System K-A-MCB-PRE

IMPORTANT SAFETY INSTRUCTIONS

553 Series.

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Saline C 6.0 Junction Box

Transcription:

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker. E & O E

Danger High Voltage AFDXXX(X) Series water makers operate on a 240vAC electricity supply and must not be opened, disassembled or repaired by unauthorised or unqualified service people. Improper operation or repair of your water maker could result in serious injury or death 2

Danger Safety Information The water maker is a high pressure device operating at up to 1000psi and must not be disassembled or repaired by unauthorised or unqualified service people. Improper operation or repair of your water maker could result in serious injury or death Before attempting to operate your water maker ensure that seawater intake is fully open and that all pre-filters are clean and unblocked. Visually check the unit before running for leaks, loose fittings and corrosion. (Do Not Operate Water Maker If You Are Unsure) Always ensure the water maker is running at the desired pressure for your area of operation and seawater temperatures (refer to full manual). If unsure please set running pressure to 825 psi. The adjustment is made on the water maker, not at the control panel. Never Attempt To Run The Water Maker Above 950psi. AFD Series water makers are not designed for and will be permanently damaged if operated in brackish or freshwater areas. 3

Index 1. Screen Operation 2. Function Page Layout 3. Starting 4. Stopping 5. Semi Auto Freshwater Flushing (option) 6. Setting Up Freshwater Auto Flush (option) 7. Winterising 8. De-Winterising 9. Errors, Faults and Messages 4

1. Screen Operation Aquafresh Touchscreen: Touchscreen Area Membrane Panel Screen Operation: Navigating your Aquafresh Touchscreen is very simple. To move between pages simply use the and arrows To enter times and/or operate functions associated with each function page use the touchscreen. To STOP the unit at any time press on the Membrane Panel or touchscreen. NOTE: The screen has a sleep/timeout facility after 10 minutes, you must wake the screen by a single touch to any part of the touchscreen before it will respond to commands. 5

2. Function Page Layout Function Page Order Initialisation Screen Ready Screen Fresh Water Flush Maintenance Screen Settings Engineering Screen Password Protected, NOT FOT CUSTOMER USE 6

3 Starting Start-up screen. during power up Initialisation Screen Unit Stopped Press START ICON to start water maker The following screens will then appear SAFI Valve position check This screen is only visible if the flush option is installed Low Pressure Pump Started 3 minutes delay before High Pressure pump starts High Pressure Pump Started Short delay before Salinity Module Initialises 7

Starting (Continued) Salinity Module Initialisation Short delay while salinity module is calibrated Unit running but not making water Short delay while membranes initialise Unit running and producing water Animated screen indicates water production CAUTION Always ensure the watermaker is running at the desired pressure for your area of operation and seawater temperatures (refer to full manual). If unsure please set running pressure to 825 psi. The adjustment is made on the watermaker, not at the control panel 8

4. Stopping Unit Running Screen Displayed: Unit running and producing water Animated screen indicates water production Press STOP ICON (or button) to stop watermaker The unit will stop immediately The following screens will then appear Unit Stopped, Restart Inhibited Short delay while internal pressures equalise. Unit Stopped, Ready, Press To Start 9

5. Manual Freshwater Flushing (option) SPECIAL NOTES: This systems requires that the vessels pressurised fresh water supply is switched on and that there is plenty of freshwater available to complete the flushing cycle for however long it may be required. This system will use freshwater from your vessels water tanks and will use approximately 3-7 litres of water per minute. At no time should chlorinated water be allowed to enter the watermaker via the vessels freshwater system and it is essential that the carbon filter is replaced regularly. If your watermaker is fitted with the optional freshwater flush system it is possible to initiate a timed freshwater flush from the touchscreen With the machine in the stopped mode: Unit Stopped Press the ARROW Membrane button Fresh Water Flush Set Time Enter desired flush time between 2 and 9 minutes Touch the Set Time area on the screen and enter the flush time required using the ESC, SHIFT, UP, DOWN and ENTER buttons on the touch screen Note: The system will not accept less than 2 minutes as a flush time. Start Flush Press START FLUSH ICON to initiate the timed flush. Flush Time Remaining Once the flushing is complete the unit will return to the normal Stopped screen Note: The unit flushing can be stopped at any time by pressing STOP 10

Manual Freshwater Flushing (continued) Unit Stopped, Restart Inhibited Short Delay while internal pressures equalise. Unit Stopped 11

6. Setting Up Freshwater Auto Flush (option) SPECIAL NOTE: This systems requires that the vessels pressurised fresh water supply is switched on and that there is plenty of freshwater available to complete the flushing cycle for however long it may be required. This system will use freshwater from your vessels water tanks and will use approximately 3-7 litres of water per minute At no time should chlorinated water be allowed to enter the water maker via the vessels freshwater system and it is essential that the inline carbon filter is replaced regularly. If your water maker is fitted with the optional freshwater flush system it is possible to initiate an automatic freshwater flush from the touchscreen With the machine in the stopped mode: Unit Stopped Press the ARROW Membrane button twice Maintenance Screen Auto Flush OFF Press OFF ICON Maintenance Screen Auto Flush ENABLED With Auto Flush enabled the unit will automatically flush the water maker upon stopping in normal mode and every 7 days for 4 minutes each time. CAUTION!: This feature is designed to be used while the boat is occupied but the water maker is not in regularly use i.e when living aboard in harbour Any unattended automated operation of complex machinery carries a risk. Reliable operation of this feature is dependent on other vessels systems being available and fault free. Aquafresh Watermakers does not recommend the use of this feature when the boat is left unattended for extended periods 12

Setting Up Freshwater Auto Flush (continued) Should power to the water maker be interrupted at any time Auto Flush Enable feature will be cancelled. Press the ARROW Membrane button twice to return to the normal screen Unit Stopped 13

7. Winterising For winterising options please see full service manual for details. 14

8. De-winterising CAUTION: Observe all precautions for handling the chemical cleaning or preservatives that may have been used in your system. Ensure the watermakers flushing lever controls are set to normal positions for seawater intake and overboard discharge and that any chemical cartridges are removed and replaced with standard filters. With the machine in the stopped mode: Unit Stopped Press the Membrane button twice Maintenance Screen Press DE-WINTERISE ICON Maintenance Screen 20 minute De-Winterise cycle will start Note: The unit de-winterising can be stopped at any time by pressing STOP Unit Stopped NOTE: In this mode the watermaker will run for 20 minutes. This cycle ensures any preservative or cleaning chemicals present are flushed overboard. It is effectively a high pressure flush overboard but it will not allow the vessels to become pressurised thus no fresh water will be produced. After the full cycle the vessels will be clean and free from chemicals used in preservation. Following the De-winterising process watermaker is now ready to use as normal. 15

16

9. Errors, Faults and Messages Your watermaker can display various message that can help diagnose maintenance issues including operational errors and faults Tank Full (Optional): Tank Full Shutdown Press ACCEPT to clear If you watermaker is fitted with the optional tank full switch the unit will automatically stop once your tanks are full. The above message will be displayed. Press the ACCEPT ICON to clear the message Change PLC Battery Change PLC Battery System warning message, it is very important the PLC internal battery is changed Please refer to service manual SAFI Valve Failure SAFI Valve Failure Investigate cause of alarm Press RESET ALARM to clear If your watermaker has the optional flush system installed this error will be displayed if a problem occurs with the SAFI valve. Inspect. Clean. Repair or Replace SAFI valve. 17

Errors, Faults and Messages (continued) Salinity Probe Error Salinity Probe/Module Fault Investigate cause of alarm Press RESET ALARM to clear This error indicates a problem with the salinity probe or module. Check probe, clean or replace probe and/or module. Low Pressure Alarm Low Pressure Alarm Investigate cause of alarm Press RESET ALARM to clear This is a common alarm and indicates a loss of pressure in the low pressure circuit of the watermaker. Common causes: Blocked or closed seawater intakes. Blocked pre-filters Air lock in the low pressure circuit Failure of the low pressure pump Failure of low pressure sensor Incorrect installation Shipside watersystem pressure too low (only in flush mode, optional) Incorrect installation: Your watermaker will not function properly and may shut down and show this fault if it is supplied by an incorrect power source. An example of this may be if an Inverter is being used to power the system. See section 4. High Pressure Alarm High Pressure Alarm (Optional) Investigate cause of alarm Press RESET ALARM to clear Indicates over pressure in the high pressure circuit of the watermaker Common causes: Blockage in the high pressure circuit Blockage in the overboard discharge Operating pressure adjusted to high Failure of high pressure sensor 18

Errors, Faults and Messages (continued) No Fresh Water No Fresh Water Investigate cause of alarm Press RESET ALARM to clear Indicates no freshwater was produced for 1 hour Common causes Salinity probe failure or dirty One or more membranes has failed 19

Page Intentionally Left Blank 20