The effect of inner tube placement on resistance and work of breathing through tracheostomy tubes: a bench test

Similar documents
RESPIRATORY PHYSIOLOGY, PHYSICS AND PATHOLOGY IN RELATION TO ANAESTHESIA AND INTENSIVE CARE

Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 6th Edition by Cairo

RSPT 1060 OBJECTIVES OBJECTIVES OBJECTIVES EQUATION OF MOTION. MODULE C Applied Physics Lesson #1 - Mechanics. Ventilation vs.

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

Instructions/Procedure for Use of the Speaking Valve

Mechanical Ventilation. Which of the following is true regarding ventilation? Basics of Ventilation

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Sign up to receive ATOTW weekly -

Mechanical Ventilation

Basics of Mechanical Ventilation. Dr Shrikanth Srinivasan MD,DNB,FNB,EDIC Consultant, Critical Care Medicine Medanta, The Medicity

Selecting the Ventilator and the Mode. Chapter 6

COMPARISON OF PORTABLE EMERGENCY VENTILATORS USING A LUNG MODEL

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Health Professional Info

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

4/18/12 MECHANISM OF RESPIRATION. Every Breath You Take. Fun Facts

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine

Ventilators. Dr Simon Walton Consultant Anaesthetist Eastbourne DGH KSS Basic Science Course

Lab 3. The Respiratory System (designed by Heather E. M. Liwanag with T.M. Williams)

Organis TestChest. Flight Simulator for Intensive Care Clinicians

PART EIGHT HIGH FREQUENCY PERCUSSIVE OSCILLATION (HFPOV )

Introduction. Respiration. Chapter 10. Objectives. Objectives. The Respiratory System

Spontaneously Breathing Lung Model Comparison of Work of Breathing Between Automatic Tube Compensation and Pressure Support

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

PROBLEM SET 8. SOLUTIONS April 15, 2004

PART SEVEN THE HISTORY AND APPLICATION OF HIGH FREQUENCY OSCILLATORY VENTILATION (HFOV)

Keeping anaesthetic pollution to minimum in theatre environment

Respiratory Physiology Gaseous Exchange

Mechanical Ventilation

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

Solutions. Digital pressure management solutions. Copyright 2013 GaleMed Corporation

Day-to-day management of Tracheostomies & Laryngectomies


Technical Data and Specifications

RESISTANCE TO AIRFLOW IN ANAESTHETIC BREATHING SYSTEMS

TOPO. operating Manual

TESTCHEST RESPIRATORY FLIGHT SIMULATOR SIMULATION CENTER MAINZ

INTELLiVENT -ASV. The world s first Ventilation Autopilot

Medical Ventilators. Ryan Sanford Daniel Tajik

Principles of mechanical ventilation. Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands

The Manley ventilator

Measuring Lung Capacity

Endotracheal Tubes - VentiSeal (High Volume Low Pressure)

Medical Instruments in the Developing World

The comparison of Work Of Breathing methodologies on a patient model

Using Common Ventilator Graphics to Provide Optimal Ventilation

Respiratory Physiology 2

Indications for Mechanical Ventilation. Mechanical Ventilation. Indications for Mechanical Ventilation. Modes. Modes: Volume cycled

ONLINE DATA SUPPLEMENT. First 24 hours: All patients with ARDS criteria were ventilated during 24 hours with low V T (6-8 ml/kg

Collin County Community College. Lung Physiology

Mechanics of proportional-assist ventilation

Inspire rpap REVOLUTION FROM THE FIRST BREATH

EXCESSIVE WORK OF BREATHING DURING INTERMITTENT MANDATORY VENTILATION


Lung recruitment maneuvers

AUTOVENT 4000 VENTILATOR

INTRODUCTION TO BI-VENT (APRV) INTRODUCTION TO BI-VENT (APRV) PROGRAM OBJECTIVES

ASV. Adaptive Support Ventilation

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

VENTILATION STRATEGIES FOR THE CRITICALLY UNWELL

Peter Kremeier, Christian Woll. 2nd. Understanding and comparing modes of ventilation. The Kronberg List of Ventilation Modes

Clinical Skills. Administering Oxygen

THE MECHANICS of RESPIRATION. Introduction

April KHALED MOUSA BACHA. Physiology #2. Dr. Nayef AL-Gharaibeh. Pulmonary volumes & capacities

Operation and Maintenance of the EPV200 Portable Ventilator

Initiation and Management of Airway Pressure Release Ventilation (APRV)

Unit 15 Manual Resuscitators

APRV: Moving beyond ARDSnet

Section 2.9 Decannulation

Automatic Transport Ventilator

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Principles of Mechanical Ventilation: A Graphics-Based Approach

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

VT PLUS HF performance verification of Bunnell Life-Pulse HFJV (High Frequency Jet Ventilator)

Panther 5 Acute Care Ventilator

3100A Competency Exam

Respiratory Pulmonary Ventilation

VENTILATORS PURPOSE OBJECTIVES

Ventrain starts a new era in ventilation

Accumulation of EEV Barotrauma Affect hemodynamic Hypoxemia Hypercapnia Increase WOB Unable to trigger MV

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Selecting and Connecting Breathing Systems

Hospital and Transport for Controlled Breathing

SLE5000 Infant Ventilator with HFO

Inspiration 7i Ventilator

Endotracheal Suctioning: In Line ETT

Chapter 9 Airway Respirations Metabolism Oxygen Requirements Respiratory Anatomy Respiratory Anatomy Respiratory Anatomy Diaphragm

Stephanie. Pediatrics. The ventilation system for neonatology

mechanical ventilation Arjun Srinivasan

Intelligent Ventilation solution from ICU to MRI

Presentation Overview. Monitoring Strategies for the Mechanically Ventilated Patient. Early Monitoring Strategies. Early Attempts To Monitor WOB

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Blease900 Ventilator PATIENT CENTERED VENTILATION

Please, after a carefully reading of given references, answer the following questions:

Initiating In-Line Ventilator Speaking Valve Protocols: Why & How? Kristin C. Dolan; CCC-SLP Kindred Hospital Melbourne, FL

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

NOTE: If not used, provider must document reason(s) for deferring mechanical ventilation in a patient with an advanced airway

Transcription:

Anaesthesia 3, 68, 76 8 Original Article doi:./anae.94 The effect of inner tube placement on resistance and work of breathing through tracheostomy tubes: a bench test A. Carter, S. J. Fletcher and R. Tuffin 3 Consultant in Anaesthesia and Intensive Care Medicine, Mid Yorkshire Hospitals, Wakefield, UK Director of Intensive Care, 3 Advanced Trainee in Intensive Care Medicine, Bradford Teaching Hospitals NHS Foundation Trust, Bradford, UK Summary To reduce the risk of tracheostomy tube blockage, a removable inner tube can be used. However, this will reduce the size of the lumen and will increase airflow resistance and work of breathing. The magnitude of this increase in workload is unknown. We undertook a bench test to measure the effect. A lung model was developed to breathe through the tracheostomy tube. We created pressure volume curves from which we calculated work of breathing with and without an inner tube using 6 mm tracheostomy tubes over a range of respiratory rates and tidal volumes. The inner tube increased the resistive work of breathing by an average factor of.. The extra work of breathing imposed easily exceeded the normal total work of breathing. Our results will aid a risk benefit analysis when deciding whether to use inner tubes. Selecting a larger tracheostomy tube is likely to aid weaning from mechanical ventilation.... Correspondence to: S. Fletcher Email: stephen.fletcher@bthft.nhs.uk Accepted: 8 October Failure to wean critically ill patients from mechanical ventilation is largely due to an imbalance between the required work of breathing and weakness of the patient s respiratory pump (due to muscle wasting and critical illness neuromyopathy). Work of breathing is increased due to a combination of poor respiratory system compliance and the imposed resistive work of breathing due to the artificial airway and breathing system. In these patients, a tracheostomy may be formed with the aim of facilitating weaning mainly by reducing the need for sedation but also by reducing airway resistance when compared with trans-laryngeal tracheal tubes [, ]. Blockage of the tracheostomy tube with accumulated secretions may be life-threatening and the use of a replaceable inner tube is suggested as a way of reducing this risk [3]. However, inserting the inner tube decreases the internal diameter of the tracheostomy lumen and therefore will increase the resistance and resistive component of the work of breathing. According to the Hagen Poiseuille law, assuming laminar flow, resistance is inversely proportional to the fourth power of the radius. Thus, a small change in radius may have a significant effect on work of breathing and may adversely affect weaning. If flow is turbulent then the effect of a change in radius is even more marked. We theorised that there was likely to be a mixture of laminar and turbulent flow in the native and artificial airways; furthermore, the proportion of turbulent flow would increase as the peak flow rates increased. For these reasons, the effect of an inner tube on resistance and work of breathing is not amenable to calculation. Therefore, we undertook a 76 Anaesthesia The Association of Anaesthetists of Great Britain and Ireland

Carter et al. The work of breathing through tracheostomy inner tubes Anaesthesia 3, 68, 76 8 Table Internal diameters of Portex Blueline Ultra tracheostomy tubes. Tracheostomy tube size External diameter of tracheostomy tube; mm Internal diameter of tracheostomy tube without inner tube; mm 6. 9. 6. 5. 7..5 7. 5.5 8..9 8. 6.5 9. 3.3 9. 7.5. 4.. 8.5 Internal diameter of inner tube; mm bench study to assess that effect of the introduction of the inner tube using one of the more commonly used tracheostomy tubes in the UK (Table ). Methods In the first test (steady-state), we looked at resistance to flow through the tracheostomy tube under conditions of constant flow. In the dynamic tests, we measured work of breathing using a lung model. Portex Ò Blueline Ultra Ò tracheostomy tubes of sizes 6 were studied (Smiths Medical International Ltd, Hythe, UK). Measurements were made using a pneumotachograph (VT Plus HF; Fluke Biomedical, Everett, WA, USA). As expiration is normally passive, we only considered inspiratory work of breathing. Five tracheostomy tubes of each size were tested and data were expressed as the mean driving pressure. For the steady-state test, we attached a gas source capable of delivering variable flows to the upstream side of the pneumotachograph via -mm tubing. The tracheostomy tube to be tested was inserted via its 5-mm connector to the downstream side of the pneumotachograph. The driving pressure needed to create flows from to l.min was then recorded at -l.min steps for each size of tracheostomy tube, with and without the inner tube in place. For the dynamic test, we used a model of spontaneous respiration as described previously (Fig. ) [4, 5]. It comprises two mechanically linked bellows: the master bellows are driven by a Siemens Servo 3A ventilator (Siemens Healthcare, Surrey, UK) using a volume control mode, and with an inspiratory to expiratory (I:E) ratio of :. The slave bellows, which represent the lung, were connected via the pneumotachograph to the lower end of an anatomically accurate model trachea (taken from an Figure Diagram of the lung model used for the bench tests. intubation manikin), into which we inserted the test tracheostomy tube [, 6]. The proximal end of the tracheostomy tube was open to atmosphere. The tracheostomy tube was inserted into the model trachea through an incision at a level approximating the space between the second and third tracheal rings. The cuff was inflated and the correct orientation of the tip of the tube parallel to the tracheal wall was confirmed visually. Synchronous pressure and flow data were sampled at 5 Hz throughout the respiratory cycle at different respiratory rates (,, 3, 4 min ) and different tidal volumes (3, 5, 7, 9 ml). The data were then uploaded to Microsoft Excel allowing us to calculate the area of the inspiratory portion of the pressure volume loops to obtain the resistive work of breathing, measured in Joules [7]. To enable comparison, these values were then indexed by tidal volume to Joules per litre (resistive work of breathing (J.l ) = work for one breath (J)/tidal volume (l)). In a bench test not involving biological material, the only sources of measurement variability and error reside in the test subject (in this case, tracheostomy tubes) and in the measuring equipment. The manufacturing tolerances of the Portex Blueline Ultra tracheostomy tubes are.5 mm on the diameter and. mm on the Anaesthesia The Association of Anaesthetists of Great Britain and Ireland 77

Anaesthesia 3, 68, 76 8 Carter et al. The work of breathing through tracheostomy inner tubes length (information supplied by Portex). The flow measurement error of the pneumotachograph is %. Therefore, the results derived from one exemplar tracheostomy tube should be valid. However, to confirm this, we ran the steady-state tests with five tracheostomy tubes of each size and calculated the mean and standard deviations for the driving pressure. The variability in the measurements was very small as predicted and the dynamic tests were therefore performed using one representative tube of each size. Pressure (cmho) 8 7 6 5 4 3 Results Steady-state test In the steady-state tests, the driving pressures required to produce a given flow increases in a curvilinear fashion confirming turbulent flow in the tracheostomy tubes (Fig. ). Table shows the mean (SD) driving pressures at each flow rate. Dynamic test Figure 3a d show the measured imposed work of breathing in the tracheostomy tubes with and without 4 6 8 Flow (l.min ) Figure Pressure-flow characteristics of differing tracheostomy tubes with and without inner tubes: ( ) 6 inner, ( ) 6 no inner, ( ) 7 inner, ( ) 7 no inner, ( ) 8 inner, ( ) 8 no inner, ( ) 9 inner, ( )9no inner, ( ) inner, ( ) no inner. Table Results of the steady-state tests. Figures are mean (SD) driving pressures in cmh O. Tube size inner cannula l.min 4 l.min 6 l.min 8 l.min l.min 6 inner 4.8 (.8) 4.8 (.) 3.78 (.4) 5.94 (.6) 77.78 (.95) 6 no inner.96 (.6) 7.6 (.9) 5.4 (.3) 5. (.36) 37.38 (.55) 7 inner 3. (.3).3 (.4). (.5) 36.7 (.9) 54.8 (.8) 7 no inner. (.4) 3.66 (.6) 7.6 (.6).8 (.) 9. (.54) 8 inner.7 (.5) 5.56 (.9).68 (.) 9.84 (.5) 9.84 (.45) 8 no inner.6 (.4).8 (.) 4.64 (.5) 7.94 (.9).9 (.46) 9 inner. (.4) 3.8 (.4) 6.9 (.7).4 (.6) 6.94 (.9) 9 no inner.4 (.4).5 () 3.6 (.5) 5.8 (.4) 7.6 (.8) inner.6 (). (.4) 4.8 (.4) 7. (.7).56 (.6) no inner.3 ().6 (.5).4 (.5) 3.78 (.4) 5.5 (.4) their inner cannula at respiratory rates 4 min. The normal total work of breathing in healthy subjects (thought to be the optimal work of breathing) of.5 J.l is also shown [7]. As the tidal volume and the respiratory rate rises, there is an increase in resistive work of breathing. This increase is more marked in the smaller tracheostomy tubes. Figure 4a d show the additional imposed work of breathing due to insertion of the inner cannula. This was calculated by subtracting the resistive work of breathing of each tracheostomy tube without its inner cannula from the value with its inner cannula for each respiratory rate/tidal volume combination. It can be seen from these graphs that at low respiratory rates the imposed resistive work of breathing added by the inner cannula is modest. However, as the respiratory rates and tidal volumes increase, the added work by placing the inner cannula rapidly exceeds the optimal total work of breathing in the size 6 and 7 tubes. In an attempt to summarise these data, we calculated the average ratio of the work of breathing with and without inner tube for each size of tracheostomy, 78 Anaesthesia The Association of Anaesthetists of Great Britain and Ireland

Carter et al. The work of breathing through tracheostomy inner tubes Anaesthesia 3, 68, 76 8 (a) (b).5.5.5.5 3 5 7 9 3 5 7 9 (c) (d).5.5.5.5 3 5 7 9 3 5 7 9 Figure 3 (a d) Imposed resistive work of breathing for differing tracheostomy tubes (with and without inner cannula) at increasing respiratory rates (a, min ; b, min ; c, 3 min ; d, 4 min ). Key for tube sizes inner cannula: ( ) 6 inner, ( ) 6 no inner, ( ) 7 inner, ( ) 7 no inner, ( ) 8 inner, ( ) 8 no inner, ( ) 9 inner, ( ) 9 no inner, ( ) inner, ( ) no inner. ( ) Normal total work of breathing. for each of the test conditions. For the size 6, the work of breathing on average increased by a factor of.; for size 7, a factor of.8; for size 8, a factor of.3; for size 9, a factor of.9; and for size, a factor of.6. Discussion The results from the steady-state test show that flow in the tracheostomy tubes is turbulent, and therefore resistance is inversely proportional to the fifth power of the radius. The driving pressures from the static tests are equivalent to the negative inspiratory pressure a spontaneously breathing patient would have to generate in the trachea to produce an equivalent gas flow. The pressure required to produce greater gas flows increases rapidly in a non-linear fashion, and the effect is amplified with smaller internal diameters. Inspiratory pressures of greater than cmh O are required to produce flows of 6 l.min or more in tubes with an internal diameter of 6 mm or less. Flow rates of more than l.min are often seen in respiratory failure [5]. These data suggest inter alia that it would be almost impossible to sustain these flow rates when a size 6 or 7 tracheostomy of this type is used with its inner cannula. The results from the dynamic tests show that placement of the inner cannula in Portex Blueline Anaesthesia The Association of Anaesthetists of Great Britain and Ireland 79

Anaesthesia 3, 68, 76 8 Carter et al. The work of breathing through tracheostomy inner tubes.6 (a).4..8.6.4. 3 5 7 9.6.4..8.6.4. (b) 3 5 7 9.6.4..8.6.4. (c) 3 5 7 9.6.4..8.6.4. (d) 3 5 7 9 Figure 4 (a d) Additional work of breathing due to inner tube for differing tracheostomy tubes at increasing respiratory rates (a, min ; b, min ; c, 3 min ; d, 4 min ). ( ) Normal total work of breathing. Key for tube sizes: ( ) Size 6, ( ) Size 7, ( ) Size 9, ( ) Size. Ultra tracheostomy tubes significantly increases imposed inspiratory resistive work of breathing. The effect was greatest with the size 7. tube, with an increase in resistive work of breathing by a factor of.8 at clinically relevant respiratory rates and tidal volumes. This is because the inner cannula in the 6. tube only reduces the internal diameter by mm compared with a.5 mm decrease in internal diameter in all other tubes tested (see Table ). The 7. tube therefore has the greatest proportional change in internal diameter when the inner tube is inserted. Total work of breathing in normal subjects is in the range of.3.6 J.l [7]. The optimal work of breathing whilst weaning from a ventilator is difficult to assess; if too low, respiratory muscle wasting can develop; if too high, muscle fatigue and respiratory failure may be induced. The total work of breathing in the normal healthy range would seem to correspond to a reasonable muscle and energy load in both weaning and respiratory failure [7]. Our experiment only considers inspiratory imposed resistive work of breathing. Even so, the results show that in the smaller tubes with the inner cannula in place, the resistive work of breathing starts to exceed normal total work of breathing at fairly low tidal volumes and respiratory rates. Increased imposed work of breathing has been shown to cause failure to wean from mechanical ventilation [8]. In vivo, the imposed work of breathing will be cumulative with the resistive work of breathing of the rest of the bronchial tree and the elastic and viscous work of breathing used to expand the lungs. If the total work is already high due to poor lung compliance or airway narrowing, then even small increases in imposed work are highly likely to cause respiratory decompensation and failure to wean. The increased imposed resistive work of breathing caused by use of the inner cannula does, however, need to be weighed against the important benefits that the inner tube provides. It can be removed readily and cleaned or replaced to remove secretions. Encrusted secretions can be difficult or impossible to remove with suctioning alone. It has been shown that organised secretions in tracheal tubes can reduce the effective internal tube diameter causing a significantly increased resistance and imposed resistive work of breathing [9]. Perhaps the major benefit of the inner cannula is the ability to remove it should the inner lumen become completely blocked. This makes treatment of a potentially life-threatening emergency situation much quicker and easier without the need for an emergency removal and/or replacement of a new tracheostomy tube. 8 Anaesthesia The Association of Anaesthetists of Great Britain and Ireland

Carter et al. The work of breathing through tracheostomy inner tubes Anaesthesia 3, 68, 76 8 In 8, the UK Intensive Care Society published Standards for the care of adult patients with a temporary tracheostomy in which they state Tracheostomy tubes with an inner cannula are inherently safer and are normally preferred [3]. The document also states: As a general rule, most adult females can accommodate a tube with an outside diameter of mm, whilst a tube with an outside diameter of mm is suitable for most adult males. Using Portex Blueline Ultra tracheostomy tubes, this gives a maximum size of 7 in males and size 6 in females. With the inner cannula in situ, the internal diameter is 5.5 and 5 mm, respectively. Our results show that these tube sizes produce a marked restriction to flow and increased work of breathing and thus the guidelines may not be appropriate. Whilst a larger diameter lumen would appear beneficial, we are limited by the resulting outside diameter that the trachea is able to accommodate. Reducing the difference between the internal and external diameter would seem to be advantageous, but would require a thinner tube wall, whilst retaining wall strength. Portex Blueline Ultra tubes are made from thermosensitive PVC, which is designed to be rigid enough for percutaneous insertion and then soften once in situ to accommodate individual anatomy. Whilst thinner tubes are available, they tend to be rigid, for example, the Shiley and Trachoe. A more rigid tube will transmit more of the weight of the breathing system onto the tracheal wall, arguably increasing the risk of mucosal ischaemia and resultant fibrosis. Imposed work of breathing during spontaneous respiration can be offset to a certain degree by using inspiratory assist. Our results suggest, however, that conventional pressure support ventilation may not fully overcome the resistive work imposed by smaller diameter tracheostomy tubes. Automated tube compensation employs a mathematical model to calculate the tube resistance for specific tube sizes at differing flow rates. The delivered pressure support can then be adjusted to offset the resistance. Automated tube compensation has been shown to be more effective at reducing imposed work of breathing compared with simple pressure support ventilation alone, whilst improving patient comfort, and maintaining cardiovascular stability [ ]. The use of such ventilatory modes may improve weaning success, particularly when smaller tracheostomy tubes are employed. However, it is important to remember to set the actual internal diameter of the tube when an inner cannula is used, rather than the size written on the box or cuff e.g. a size 8. Portex Blueline Ultra with an inner cannula in situ has an inner diameter of 6.5 mm not 8 mm. It is likely that the values for work of breathing for any given lumen size that we measured will be similar for the same sizes but different makes of tracheostomy tube. Differences may occur due to differing design (for example different radii, different lengths). Our study has some limitations. At higher inspiratory pressures (> 3 cmh O), the slave bellows tended to collapse; therefore, we could not generate data for the smaller tubes at the extremes of the test protocol. However, it is equally likely that a human would be unable to generate such negative pressures. Thus, loss of these data does not alter our conclusions. Another potential criticism is that we did not look at the expiratory work of breathing. Whilst expiration is normally passive, at expiratory pressures greater than cmh O, expiration becomes active [3]. Expiratory pressure will correlate with inspiratory pressure and thus we are likely to have underestimated total resistive work of breathing with smaller tubes and higher respiratory settings. However, this makes our findings more, not less, significant. Our results will not guide decisions whether to use fenestrated tubes or deflate the tracheostomy cuff as part of the weaning process. However, if the tracheostomy tube is capped off, forcing the patient to breathe either through the fenestration and/or around the tube, then thought needs to be given to the size of the fenestration and the cross-sectional area of trachea between the tube and the tracheal wall. As we have demonstrated, small changes in airway dimensions can impose significant increases in respiratory workload. In conclusion, although the decision of whether to use an inner cannula is complex in patients with weaning difficulty, our data provide an estimate of the increase in imposed work of breathing when they are used and thus should inform this decision making. We would suggest the following: Select the largest possible tracheostomy tube. Anaesthesia The Association of Anaesthetists of Great Britain and Ireland 8

Anaesthesia 3, 68, 76 8 Carter et al. The work of breathing through tracheostomy inner tubes When a patient is failing to wean, consideration should be given to the possibility that the artificial airway is imposing excessive respiratory work. 3 Do not routinely use inner tubes where there is adequate nursing and suitable medical supervision, but check regularly for accumulation of secretions. 4 When a patient is to be discharged to a non-critical care environment with a tracheostomy in situ, then an inner tube should be inserted. A 4-h trial to demonstrate that the patient can cope with the extra work of breathing due to the inner tube should be performed before discharge. 5 During weaning, automated tube compensation may help to offset the imposed work of breathing due to presence of an inner tube. Competing interests No external funding and no competing interests declared. References. Yung MW, Snowdon SL. Respiratory resistance of tracheostomy tubes. Archives of Otolaryngology 984; : 59 5.. Epstein SK. Anatomy and physiology of tracheostomy. Respiratory Care 5; 5: 476 8. 3. Intensive Care Society (UK). Standards for the care of adult patients with a temporary tracheostomy, London: Intensive Care Society, 8. 4. Lyle DJR, Nunn JF, Hawes DWC, Dickins J, Tate M, Baker JA. A model lung with the capacity for simulated spontaneous breathing. British Journal of Anaesthesia 984; 56: 645 9. 5. Glover GW, Fletcher SJ. Assessing the performance of the Whisperflow continuous positive airway pressure generator: a bench study. British Journal of Anaesthesia 9; : 875 8. 6. Mehta S, Myat HM. The cross-sectional shape and circumference of the human trachea. Annals of the Royal College of Surgeons of England 984; 66: 356 8. 7. van Heerde M, Roubik K, Kopelent V, Pl otz FB, Markhorst DG. Unloading work of breathing during high-frequency oscillatory ventilation: a bench study. Critical Care 6; : R3. 8. Kirton OC, DeHaven CB, Morgan JP, Windsor J, Civetta JM. Elevated imposed work of breathing masquerading as ventilator weaning intolerance. Chest 995; 8: 5. 9. Wilson AM, Gray DM, Thomas JG. Increases in endotracheal tube resistance are unpredictable relative to duration of intubation. Chest 9; 36: 6 3.. Haberth ur C, Fabry B, Stocker R, Ritz R, Guttmann J. Additional inspiratory work of breathing imposed by tracheostomy tubes and non-ideal ventilator properties in critically ill patients. Intensive Care Medicine 999; 5: 54 9.. Guttmann J, Bernhard H, Mols G, et al. Respiratory comfort of automatic tube compensation and inspiratory pressure support in conscious humans. Intensive Care Medicine 997; 3: 9 4.. Guttmann J, Haberth ur C, Mols G, Lichtwarck-Aschoff M. Automatic tube compensation (ATC). Minerva Anestesiologica ; 68: 369 77. 3. Nunn J. Nunns Applied Respiratory Physiology. 4th edn. Cambridge: Butterworth Heinemann, 993 8 Anaesthesia The Association of Anaesthetists of Great Britain and Ireland