AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Similar documents
ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

ACV-10 Automatic Control Valve

Cover Page for Lab Report Group Portion. Head Losses in Pipes

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Cover Page for Lab Report Group Portion. Pump Performance

Application Note AN-107

UNIVERSITY OF WATERLOO

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

TR Electronic Pressure Regulator. User s Manual

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Model EXAxt AV550G. Averaging Oxygen Analyzer

EPP4 Pressure Regulator Basic G 1/4"

HumiSys HF High Flow RH Generator

PEAPOD. Pneumatically Energized Auto-throttled Pump Operated for a Developmental Upperstage. Test Readiness Review

Technical Data Sheet MF010-O-LC

Mass Flow Controller (MFC) for Gases

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

780S Ultra High Purity Series

SINGLE VALVE WITH LOW-FLOW BYPASS

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Ocean Observatories Initiative. Coastal & Global Scale Nodes. Hydrogen Safety. OOI Surface Mooring Hydrogen Safety Review

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

BUBBLER CONTROL SYSTEM

Review of the Hall B Gas System Hardware. George Jacobs

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Supplementary Operator s Manual 42/24-14 EN Rev. 3

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

Mass Flowmeters. Mass Flowmeters for Gases

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

The Ins and Outs of I/P Transducers

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

PROCESS MONITORING AND CONTROL

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

analytical bulk flow distance FLOW level pressure temperature industrial communication

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Oxidation Stability of Gasoline and Aviation Fuels

The University of Hong Kong Department of Physics Experimental Physics Laboratory

Design of an Automated Perfusion Pump James J Higham

Steam Turbine Performance Measurement. Pressure Measurement

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Project Number: P14474

The Discussion of this exercise covers the following points:

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

CONTROL VALVE TESTING

8.1 Calibration of gas sensors

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

BUBBLER CONTROL SYSTEM

Marc McMullen. Physics Detector Support Group

Mass Flow Meter (MFM) for Gases

AC : A LABORATORY EXERCISE TO DEMONSTRATE HOW TO EXPERIMENTALLY DETERMINE THE OPERATING POINT FOR A FAN

Features. Description

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

Major Design Features

Series Environmental Chambers

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

A CO 2 Waveform Simulator For Evaluation and Testing of Respiratory Gas Analyzers

UNDERSTANDING, ACCELERATED

THE CANDU 9 DISTRffiUTED CONTROL SYSTEM DESIGN PROCESS

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

Hazards associated with the gas system and how to mitigate them

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Ultra High Purity Model 780S

REASONS FOR THE DEVELOPMENT

The Air Liquide Gas System Equipment Brochure

DataCan. Linewise System. Description. Hardware. Applications

Fail Operational Controls for an Independent Metering Valve

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Lab 1: Pressure and surface tension. Bubblers, gravity and the mighty paper clip.

Mass Flow Controller (MFC) for Gases

Gas density monitor With integrated transmitter Model GDM-100-TI

Pneumatic high-pressure controller Model CPC7000

University of Minnesota Nano Center Standard Operating Procedure

Products for Cryogenic Applications

Bubble Tube Installations

QBS Electronic Pressure Regulator

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Transcription:

AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi Steven Allee, University of Southern Mississippi American Society for Engineering Education, 2010 Page 15.860.1

Measurement of Hydrogen in Helium Flow Abstract The National Aeronautics and Space Administration (NASA) is one of the largest consumers of gaseous helium in the world. Because helium is a nonrenewable resource, it is desirable to conserve the gas whenever possible. This research is a first step toward enabling helium conservation through real-time measurement of H2 concentration in the purge gas. A commercial H2 sensor will be characterized for use as the real-time sensor and H2 concentration as an indicator of the effectiveness of the purging process, thus enabling the minimizing of helium waste. A test apparatus for water and liquid nitrogen flow research was retrofitted to provide for measurement of hydrogen in a helium flow stream. Results are currently being compiled but will be presented in the final paper, as well as the overall process and activities related to student learning. Student Involvement The project was the result of collaboration between the programs of Physics and Electronics Engineering Technology. Students participated in the design, specification, acquisition, and installation of appropriate hardware and software. Faculty and students conducted periodic meetings to develop strategies for accomplishing goals and reporting periodic progress. All students were able to assert their strengths in the project while strengthening their weaknesses in various engineering and scientific areas. Most of the work was completed by graduate students under direct supervision of a faculty. Introduction An existing pipe structure was available for retrofitting, which allowed for a quick turnaround in establishing a working test fixture. The available test fixture was designed to provide a flow of water at 80 gal/min continuously, via a recirculation system. Additionally, the fixture was fabricated with cryogenic rated materials and components and could also accommodate liquid cryogens with up to 8 supply dewars in parallel. Retrofitting included changing the input and output fittings, rewiring and rerouting of input and output devices, and installation of a hydrogen sensor. Hydrogen Test Apparatus The hydrogen test fixture was developed for measuring relevant process variables and enable helium concentrations measurements under fluid flow conditions. The dynamic flow test structure consists of a 7.62 m (25 ft) length of 5.08 cm (2 in) diameter stainless steel pipe with capabilities of accepting gas, water or cryogenic fluids. This test platform monitors pressure, temperature, and flow at various locations along the pipe stream. Output of the hydrogen flow channelled through an exhaust system and vented to the building exterior. Figure 1 shows the general layout of the test fixture hardware. Page 15.860.2

Gas Exhaust Cryo Valve Flow Thermocouple 3 and 4 H 2 HSensor 2 Scan Thermocouple 5 and 6 Thermocouple 7 and 8 Pressure Thermocouple 1 and Pressure Sensor Flow Tube He H 2 Figure 1. Simplified Hydrogen Test Fixture Diagram Sensors and Instrumentation Hydrogen flow is regulated by direct reading flow tubes designed for specialty gases. Pressure and temperature are monitored at the inlet of the supply and at the sensor itself. A turbine flow meter is situated downstream from the sensor for measuring flow rates during testing. An automated 1.5 ball valve at the outlet controls the system flow rate and provides variable back pressure to enable gas conservation. A computer data acquisition system with graphical user interface collects process data as well as controls the outlet valve position, for accurate and automatic data collection during testing. All data collected during testing is automatically saved to a file for future analysis. All sensors were calibrated per manufacturer s specifications. Figure 2 shows the test fixture instrumented with the ball valve in the foreground and other process sensors mounted along the pipe fixture. The hydrogen sensor is designed to detect and/or measure hydrogen as a component of a gas mixture. The solid state Figure 2. Hydrogen Test Fixture sensor has a sensitivity of 0.5% to 100% at 1 atmosphere on a volume basis in a single component gas background. The sensor output is a 0-5V signal with internally activated outputs that are triggered at 2% and 0.8% H 2 concentration. Recommended operating temperature is rated for 20 C to +100 C, but future testing could develop methodologies for extending operation into the realm of cryogenic temperatures. The sensor has an output of 0-5 V DC and an RS232 digital output. The sensor output signal is connected directly to a Peripheral Component Interconnect (PCI) EXtensions for Instrumentation Page 15.860.3

(PXI) computer data acquisition system. The PXI also detects the position of the sensor relay contacts. This is accomplished by sourcing 10V dc from a Signal Conditioning for Instrumentation (SCXI) chassis. The SCXI is connected to the PXI via an SCXI extension chassis. Figure 3. Hydrogen Graphical User Interface Initially, multiple graphical user interfaces (GUI) were developed to accommodate manipulation and display of all input device data, as well as controlling system output devices. The Hydrogen GUI acquires the output from the hydrogen sensor as a 0-5V DC input signal. The relay voltage is sourced from the SCXI 5 V dc output. The initial GUI shown in Figure 3 uses a graph indicator to represent the hydrogen sensor voltage output relevant to hydrogen concentration over time. Two virtual LEDs indicate the state of the hydrogen concentration relays. Two pressure sensors were installed in the test fixture, with one at the inlet and the other near the hydrogen sensor. Each sensor measures from 0-300PSI and has an output of 4-20mA with zero and span adjustments. The sensor has a pre-linearized output and is connected directly to the PXI platform. Redundant type K thermocouples are strategically placed along the test fixture at the inlet, near the hydrogen sensor, and near the outlet of the system. All thermocouples are connected to an FPGA controller. The PXI records data from each of the thermocouples via a TCP/IP connection with the FPGA controller. The 1.5 inch ball valve (Fig. 4) is situated at the output end of the test stand. It has both manual and remote operation modes with a remote position indicator. An analog 4-20mA input signal is required to control the valve position, while a 4-20mA output signal indicates the position of the valve. The valve is connected to the PXI via the SCXI. The position can be read by the PXI and is integrated into the graphical user interface program. The valve is used to control the flow of gas through the system as well as provide control over back pressure. Figure 4. Ball Valve Page 15.860.4

Test Procedure The established test procedure involves mixing hydrogen in helium with pure helium. The gases will be mixed at various ratios to achieve a variety of H2 concentrations. The apparatus will be vented to air, so that H2 concentrations will remain below the lower explosive limit for hydrogen. The hydrogen sensor will be tested to identify its limits of detection for hydrogen in helium, thus verifying that operation in a helium background does not compromise the sensor calibration. Normally, calibration of the hydrogen sensor is conducted in a nitrogen environment. The test procedure will also incorporate various mounting and sampling methodologies in order to establish their respective measuring accuracy and response. Data Collection and Analysis An integrated virtual instrumentation GUI was developed that incorporated all input and output devices within the dynamic flow test fixture. With this program, all data is displayed on a single screen, and available control over the system is coordinated at the desktop. Results Initial tests included a pressurization of the system in a closed state, and a subsequent measuring of pressure over time to provide an indication of the leak rate of the system as shown in Figure 5. A single apparent leak was found, but the leak rate proved to be acceptable and the leak was not in an easily operable location. Therefore, testing proceeded with the system in its current state. Figure 5. Test Fixture Leak Rate The hydrogen sensor has a sensitivity range down to 0.5% for H 2 by volume at one atmosphere. If a threshold for explosive concentration of hydrogen is regarded as 4%, then testing could be performed at defined intervals from 0% to 3.5% without concern for explosion potential. Furthermore, the output of the system will be exhausted directly to air outside the building. Page 15.860.5

Characterization tests of the hydrogen sensor were conducted and results are provided in the following graphs (Fig. 6). The responses are presented without units due to proprietary and intellectual property agreements. However, the overall response can be observed with the understanding that the x-axis is time and the y-axis is sensor output voltage. The graphs show sensor output versus time during changes in composition of the hydrogen in helium concentration flow stream. All changes of input concentration were performed at one minute intervals and 0.5% increments from 0 to 2.5%. The red line indicates the original configuration, with the green line indicating response with the sensor placed at the gas input location. The blue line represents the sensor output when mounted in a 12-inch standoff. Inline vs. Standoff Standoff Figure 6. Measurement Response Relative to specifications published by the manufacturer of the sensor, it was able to detect small changes in hydrogen content within a moving helium mixture stream. However, the output indication was in error when compared with the calibrated gas. The sensor provided an output that was about 1.5% higher than the actual value of concentration. Analysis showed that the sensor output provides an output peak of 4% when reading the calibrated 2.50% gas mixture. Measurements were taken while both incrementing and decrementing concentration, to determine if there were any hysteresis in the measurement process. Observed hysteresis was minimal. The time delay for detecting a change in the stream was minimal. The standoff created an additional time delay, and may be more indicative of what response could be expected on the actual test stand. Page 15.860.6

Conclusions Successful implementation of this project could lead to significant conservation of hydrogen. A key element of this project is that if successful, transferring the technology to a real world application should be fairly straight forward. Results of initial testing of system components were positive, with all components functioning as expected. The sensor was able to detect small changes in hydrogen content within a moving helium mixture stream. The measurement error compared to calibrated gas was consistent and repeatable, but inaccurate. The sensor provided an output that was about 1.5% higher than the actual value of concentration. Upon obtaining repeatability and minimal hysteresis, it is believed that the measurement accuracy can be resolved with additional efforts. Questions as to whether that time delay is acceptable or will be even further increased by implementation will need to be addressed in future investigations. Overall, the project was a good learning experience for all students involved. Students were heavily engaged in the test setup, calibration, and operation, as well as data analysis. The effects on students engaged in this process appear to be very encouraging, as there has been extensive positive interaction among the students and optomistic feedback regarding this project. Page 15.860.7