INDEPENDENT TESTS SHOW THAT THE TX100 REGULATOR, EASILY EXCEEDS THE REQUIREMENTS OF THE EUROPEAN REGULATOR PERFORMANCE STANDARD EN250.

Similar documents
Flathead VI Owner s Manual

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

X-Tech CLV User Manual. English

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

RG3100 and RG3100Ice Regulator System

RG1200 Regulator System

Service and Repair Manual

R0001. Northern Diver. HYDRA Regulator Manual

RG1200 Service and Repair Manual

Gemini Owner s Manual

Toll Free: (888) M A D E I N T H E U. S. A.

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

SCUBATECH. Instructions for use. Demand regulators. Series models R1, R2, R3,R5, V2 (ICE, PRO, TEC, SPECIAL, OCTO, MONO)

SHERWOOD OWNER S MANUAL

Regulator Owner s Manual. Regulator Owner s Manual

RG2200 BC Integrated Octopus

12S 1st Stage. -Maintenance Procedure-

SHERWOOD PRO OWNER S MANUAL

REGULATORS OWNER S MANUAL

SCUBAPRO Repair Guide. S600-S550 Second Stages

Training. Testor Training Manual

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

REGULATOR OWNER S GUIDE

G250/G250 HP Compatibility of Upgrade Kit

STATEMENTS OF FACT BENCH BG-4 CONTEST. 1. A positive pressure leak could be caused by a leakage in or at device components.

Apeks T20 First St age Service & Repair Manual. for Authorized Sea Quest Service Centers Sea Quest, Inc.

Regulator Owner s Manual...

O2 TECH REG O24/Alpha 7 Regulator owner's guide

In this manual; Warnings, Cautions and Notes calls your attention to information provided to help ensure your safety. Always dive safely.

Regulator Owner's Manual

DS, US, TEK3 & Extrair FIRST STAGE REGULATOR

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG

AIR2-5 th Generation Octopus / BC inflator

DS, US, TEK3 & Extrair FIRST STAGE REGULATOR

Regulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1

SuperFlow Scuba Regulator Assembly

DIVATOR RS4 USER MANUAL

FSR & FST FIRST STAGE REGULATOR

AIR SOURCE. Owner's Manual

NEPTUNE SPACE IRON MASK OWNER S MANUAL

TECHNICAL TRAINING SS1

APEKS TX 50 TECHNICAL MANUAL. Regulator REV 05/13

STOP. Chapter 1 General Information KMDSI Products. 1.1 Introduction. EXO Full-Face Mask Manual

98695A01 - THE CONCEPT OF THE DIVATOR FAMILY

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

B.C.D. Buoyancy Compensator Device User Manual

CS150 CAP STAPLER OWNER S MANUAL

AP100 AUTO AIR. User Instruction Manual

Regulators Atemregler Détendeurs Erogatori Reguladores Ademautomat Reguladores Регуляторы Reduktorok Automaty oddechowe Regulátory Regulatori

THERE WHEN YOU NEED IT

The Envoy. Regulator Service Manual. For Zeagle Envoy 1st and 2nd Stage Scuba Regulators

4 ANGLE GRINDER MODEL NO: CAT 52 PART

TX SECOND STAGE REGULATOR

Where Depth of Experience Produces the Height of Innovation. OWNER S MANUAL BRUT SRB

Chapter 1 General Information KMDSI Products

Regulator Owner Manual

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

2017 APEKS BUYER S GUIDE

Universal Charging and Testing Unit FPU-1

Installation, Operation, and Maintenance Manual

Chapter 1 General Information KMDSI Products

Deep Six Signature Regulator Technician Service Manual

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS


MEDICAL CYLINDER VALVES

Manuale d uso Direction for use Manuel d instructions Bedienungsanleitung Manual de istrucciones Pуководство 潜水呼吸调节器使用手册

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

EQUIPMENT. All scuba cylinders have markings stamped at the neck. These will include, regardless of the country of manufacture, the following:

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

SECTION FIVE: OP-1B (XLDS) HIGH PRESSURE AIR STORAGE SYSTEM (HPASS) 02/17/2012

Oxygen Demand Valve. Instructions for Use

R5 Tec Black DIN / Yoke 1 st Stage Service and Repair Manual

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS


Apollo A-320 NITROX and A-320 CMF First Stage Regulators

ZEOS 28 ZEOS 38 HYDROS 40 HYDROS 50 READ CAREFULLY. YOUR COMFORT AND SAFETY IS WORTH MORE THAN 15 MINUTES.

SCUBATECH. User Instruction Manual. Buoyancy compensators. Range of models

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

NEPTUNE SPACE PREDATOR FULL FACE MASK OWNER S MANUAL

SERVICE MANUAL LEGEND FIRST STAGE

MAINTENANCE PROCEDURE FOR X 650

ZEOS 28 ZEOS 38 HYDROS 40 HYDROS 50. User manual English

Hydraulic Punch Drivers

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Operating Instructions Model and Hydrostatic Test Pump

Balanced SCUBA Regulator User Guide

CSA Sample Draw Aspirator Adapter Operator s Manual

INSTRUCTION MANUAL IT IS EXTREMELY IMPORTANT THAT YOU READ THIS MANUAL AND MAKE THE APPROPRIATE ADJUSTMENTS TO THE AUTO AIR BEFORE USE

fenzy x4 technical manual PN (orange) PN (black)

AIR STAPLER MODEL: CSG1C Part No

Dräger Secor 7000 Diving Equipment and Systems

TECHNICAL DATASHEET ELSA MUSTER ESCAPE BREATHING APPARATUS DESCRIPTION APPLICATIONS

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

CUT OFF TOOL MODEL: CAT113

erogatori regulators detendeur atemregler regulador

J800 HOPE BUOYANCY COMPENSATOR OWNER S MANUAL

Buoyancy Control Device

ADMINISTRATION GENERAL INFORMATION OCEANIC ADMINISTRATION FOR PRODUCT SERVICE PROCEDURES

Transcription:

BREATHING PERFORMANCE INDEPENDENT TESTS SHOW THAT THE TX100 REGULATOR, EASILY EXCEEDS THE REQUIREMENTS OF THE EUROPEAN REGULATOR PERFORMANCE STANDARD EN250. I.E. TOTAL WORK OF BREATHING NOT TO EXCEED 3.0 JOULES PER LITRE AT 50 METRES. TEST RESULTS PRESSURE - VOLUME DIAGRAM AT DEPTH OF 51.0 msw (167 fsw) INHALE PRESSURE = 3.67 mbar (LIMIT 25 mbar) EXHALE PRESSURE = 12.52 mbar (LIMIT 25mbar) EXT WORK OF BREATHING = 0.97 J/l (LIMIT 3.0 Joules/litre)

As Britain's leading manufacturer of SCUBA diving equipment, we pride ourselves on the quality and reliability of our products. All of which are manufactured under the BS EN ISO 9002 approved quality control system. READ THIS INSTRUCTION BOOKLET CAREFULLY BEFORE USING YOUR REGULATOR. As the owner of an Apeks regulator, you have every right to expect that it will perform perfectly. Following the care and maintenance guide near the end of this booklet will ensure reliable service. LIFETIME GUARANTEE TO THE FIRST OWNER Your regulator is guaranteed against any defects in materials and workmanship. This guarantee does not cover damages from accident abuse, neglect, alterations or improper usage, or failure to follow the care and maintenance guide. CAUTION Diving is a potentially hazardous sport. Before using any diving equipment you should be properly instructed and trained in the use of the equipment by a recognised club or organisation.

COLD WATER DIVING The C.E.N. standard defines cold water as 10 degrees C or less, in such conditions, particularly in fresh water, due to its higher freezing point. There is risk of first or second stage freeze up, normally resulting in free flowing from the second stage and consequent rapid loss of air. (The lower the temperature, the greater the risk). Equipment should be suitable for such use, particularly the first stage which must be environmentally sealed to prevent freezing. Your TX100 regulator has been specially designed to incorporate a heat exchanger into the 2nd stage, which effectively combats the problems of 2nd stage freezing. In our opinion, it is not possible to completely eliminate second stage freezing in all conditions. In order to reduce the possibility you should: 1. Ensure the cracking resistance control is screwed at least two turns in. 2. Avoid discharges of air on the surface. 3. Enter the water and submerge without delay. 4. Avoid high rates of breathing, the deeper the dive the greater the risk. 5. Do not practice buddy breathing etc. Keep YOUR regulator in YOUR mouth. In an emergency, OFFER or TAKE the spare regulator. USE OF EQUIPMENT The TX100 is CE approved, which means it meets all the relevant requirements of EN250:1993 for Demand Regulators. The TX100 should be used with breathing air that conforms to EN132, Annex A. Diving Deeper than 50 metres exceeds the limitations of the EN250 approval.

NITROX USE The TX100 regulator is suitable for use with oxygen enriched gases (i.e. Nitrox etc.) providing the oxygen content does not exceed 40%. WARNING This equipment must not be used with mixtures containing more than 40% oxygen, unless professionally converted to oxygen service. FAILURE TO HEED THIS WARNING MAY RESULT IN SERIOUS MALFUNCTION, CAUSING INJURY OR DEATH. Oxygen compatability kits are available AP0228 and instructions for 0 2 use. FIRST STAGE - Type FDS Part No. AP0535 & AP0535-1 (DIN) The TX100 first stage is a balanced diaphragm design with a unique 'DRY' environmental sealing system, that completely eliminates the need for messy silicone oil or grease filling. It is designed for use in any type of water condition and is ideal for professional and training organisations or if diving in cold or contaminated water. Incorporated in the dry system is a means of personal identification, a decal is provided on which the owner can write name, address etc. and is visible through the transparent sealing diaphragm. If the sealing diaphragm is removed to personalised the decal, it should be replaced while the first stage is pressurised. The unique layout of the first stage allows for ideal hose positioning, with upswept medium pressure ports and a compact overall design.

TX100 FIRST STAGE TYPE FDS AP0535 & AP0535-1 (DIN) ITEM PART NO. DESCRIPTION 1. AP1484/S ENVIRONMENTAL END CAP (2) AP1482 HYDROSTATIC DIAPHRAGM 3. AP1477 DECAL 4. AP1483 HYDROSTATIC TRANSMITTER 5. AP1474 SPRING ADJUSTER 6. AP1473 DIAPHRAGM CLAMP 7. AP1475 SPRING 8. AP1476 SPRING CARRIER (9) AP1478 DIAPHRAGM 10. AP1479 VALVE LIFTER 11. AP5300/S VALVE BODY (12) AP1419 H.P. VALVE 13. AP1415 SPRING (14) AP1299 'O' RING (15) AP1410 'O' RING (16) AP1300 'O' RING 17. AP5301 H.P. BALANCE PLUG (18) AP1445 'O' RING 19. AP1413 7/16" UNF BLANKING PLUG (20) AP1410 'O' RING 21. AP1487 1/2" UNF BLANKING PLUG (22) AP1409 'O' RING 23. AP1408 3/8" UNF BLANKING PLUG 24. AP1403/S YOKE CLAMP 25. AP1404 PROTECTIVE CAP (26) VR1166 'O' RING 27. AP1400 YOKE CLAMP SCREW 28. AP5015 DECAL (29) AP1409 'O' RING 30. AP1407/S YOKE CLAMP CONNECTOR (31) AP1406 DISC FILTER 32. AP1264 PROTECTIVE CAP DIN (33) AP1166 'O' RING 34. AP1471/S HANDWHEEL CONNECTOR 35. AP5306 HANDWHEEL 300BAR (36) AP1472 CONICAL FILTER (37) AP1409 'O' RING 38. AP5014 DECAL All items in brackets are to be replaced when servicing.

FIRST STAGE SPECIFICATION TYPE FDS AP0535 & AP0535-1 (DIN) TYPE MAXIMUM WORKING PRESSURE MEDIUM PRESSURE OUTPUT MEDIUM PRESSURE PORTS HIGH PRESSURE PORTS ENVIRONMENTAL PROTECTION BODY SPRINGS DIAPHRAGM OPERATED BALANCED VALVE YOKE CLAMP - 240 BAR DIN 477 TYPE 50 SCREW CONNECTOR - 300 BAR 9.2 BAR - 9.6 BAR ADJUSTABLE 3 x 3 / 8 " UNF 1 x 1 / 2 " UNF 2 x 7 / 16 " UNF WITH INTEGRAL FLOW RESTRICTORS DRY SEALED SYSTEM WITH INTERNAL PERSONAL IDENTIFICATION DECAL. SOLID BRASS FORGING WITH SATIN CHROME FINISH. STAINLESS STEEL 'O' RINGS NITRILE (VITON FOR O 2 ) DIAPHRAGM REINFORCED NEOPRENE SECOND STAGE SPECIFICATION AP0537 TYPE ENVIRONMENTAL PROTECTION BREATHING CONTROLS MOUTHPIECE PNEUMATICALLY BALANCED POPPET VALVE HEAT EXCHANGER SYSTEM FULL VENTURI CONTROL - LEVER CRACKING RESISTANCE CONTROL - KNOB 'COMFOBITE' - SILICONE

TX100 SECOND STAGE AP0537 The TX100 second stage is a pneumatically balanced valve system and is the most advanced diver adjustable breathing system available. Independent performance tests have established that this regulator can supply air, within the recommended limits of breathing resistance to a depth in excess of 70metres. The TX100 has ergonomically designed, diver adjustable controls for cracking resistance and venturi assistance I.V.S. (Intergrated Venturi Control) allowing the diver to tune the breathing characteristics of the regulator to give virtually ideal breathing. No fixed or pre-set system can acheive an ideal level of breathing performance under all conditions. The TX100 second stage is suitable for use in all diving conditions, because of it's high efficency heat exchanger system, it can cope with even the iciest conditions without freezing, making the TX100 the perfect all round regulator.

TX100 2nd STAGE AP0537 ITEM PART NO. DESCRIPTION 1. AP2037 DEFLECTOR 2. AP2031/S NUT 3. AP5013/S HEAT EXCHANGER (4) AP1267 'O' RING 5. AP5015 DECAL 6. AP2053 PURGE BUTTON 7. AP2020 SPRING 8. AP5326 CASE COVER 9. AP2025 DIAPHRAGM COVER 10. AP2023 DIAPHRAGM 11. AP5001 CASE 12. AP1429 EXHAUST VALVE (13) AP1438 'O' RING 14. AP5324 'COMFOBITE' MOUTHPIECE 15. AP1677 MOUTHPIECE CLIP 16. AP2040 EXHAUST TEE 17. AP5339 VENTURI LEVER 18. AP1151 SPRING PIN 19. AP2033 SEAT (20) AP1154 'O' RING 21. AP2028/S VALVE SPINDLE 22. AP2035 LEVER (23) AP1267 'O' RING 24. AP2030 PLUG 25. AP2029/2S ADJUSTING SCREW (26) AP1409 'O' RING 27. AP2038 COUNTER BALANCE CYLINDER 28. AP2021 VALVE SPRING (29) AP2041 'O' RING 30. AP2036 SHUTTLE VALVE (31) AP2034 RUBBER SEATING All items in brackets are to be replaced when servicing.

CORRECT USE OF BREATHING CONTROL SYSTEMS THE CRACKING RESISTANCE CONTROL The knurled knob adjusts the spring load on the second stage and so varies the initial cracking resistance. When the control knob is screwed completely out, a slight freeflow of air may occur. In use the knob should be screwed in, just sufficient to eliminate this effect. The setting may vary with the diver's position in the water. The resistance control may also be used to vary the breathing resistance to suit the divers individual preference or to tune the second stage to any other first stage, with an intermediate pressure up to approximately 11.5 bar/ 165 psi, for instance if used as an octopus or back up second stage. Longer hoses are available for octopus use. THE INTEGRATED VENTURI SYSTEM (I.V.S.) The venturi lever controls the continuous breathing resistance and sensitivity of the regulator, with the lever set in the plus (+) position, maximum venturi assistance is obtained and once the initial breathing effort has been made, little or no further effort is required to maintain the flow of air. If the regulator is not in the diver's mouth, when the second stage contacts the water, for instance when entering or leaving the water or on the surface, then a strong freeflow may occur. Pushing the venturi lever to the minus (-) position completely inhibits this effect. The diver can choose any position between + and - to obtain just the right level of venturi assistance.

PRE-DIVE CHECK Prior to diving always check to make certain your regulator has no water leaks by inhaling on the regulator with the air turned off, you shouldn't be able to draw in any air. If you can draw in any quantity this indicates the exhaust valve is failing to seat properly or possible damage to the mouthpiece or second stage diaphragm has occurred. Next, with the air turned on, check for air leaks and proper breathing function of the regulator. Any leaks or malfunctions indicate the need for service prior to diving. CARE AND MAINTENANCE The reliability and correct functioning of your equipment depends on the care it receives. Handle your regulator carefully, do not subject it to unnecessary shocks or impacts, particularly the second stage. To avoid build up of deposits, which may cause malfunction, it is necessary, after each dive, to rinse the regulator thoroughly in fresh water. To do this, first prevent water entering the first stage by fitting the rubber dust cap. Rinse the second stage thoroughly inside and out, DO NOT press the purge button during rinsing, as this may allow water to enter the hose and first stage. After rinsing, re-connect the regulator to an air supply and thoroughly shake and blow out all water from the system. Occasionally, lightly lubricate the yoke clamp screw. For reasons of hygiene, equipment subjected to frequent use in training organisations etc., should be finally rinsed in water containing a suitable sterilising agent. DO NOT USE SOLVENT CHEMICALS TO CLEAN THE REGULATOR! STORAGE Allow the regulator to dry thoroughly before storing in a cool dark place. SERVICING It is essential that your regulator is checked at least annually by your dealer or other competent technician. The first stage should have it's intermediate pressure checked and filter changed annually, and be fully serviced every two years. The second stage including octopus, should be fully serviced annually.

AP0203/S - 1/2" UNF REGULATOR HOSE /S The 300 bar DIN connector AP0211/S may be purchased seperately and used to convert a yoke clamp type First Stage to be suitable for use on a 300 bar system.

ASK YOUR DEALER ABOUT OTHER APEKS PRODUCTS The Extrair is an integrated regulator and cylinder valve in a compact design. It features miniature pressure gauge and can be fitted to a 0.4 litre or 3 litre pony cylinder. BUOYANCY JACKETS NX2000 wings style buoyancy jacket, with dual ripcord integrated weight release system. SB2000 conventional style "stab jacket" OCTO + Combined breathing and inflation system designed for use on buoyancy jackets. DRY SUIT BUOYANCY CONTROL VALVES. Semi -Automatic dump valves, suit inflation valves & Q.D. hoses and cuff dump valves. VIP SAFETY LIGHT Multifunction safety device, with flash mode steady / on proximity mode and unique SOS visual signal mode. AUXILIARY EQUIPT. Masks, snorkels. Instrument combos. Divers watches. Knives. Tote bag, goody bag, regulator bag. Freeflow Control Devices. DIN to yoke clamp adaptors. Oxygen compatibility kits.