MIXER - GRANULATOR - BLENDER

Similar documents
Pneumatic blending in a bin or silo that is, aerating. Saving time, labor, and money with pneumatic batch blending

METHOD OF TEST FOR THEORETICAL MAXIMUM RELATIVE DENSITY OF BITUMINOUS PAVING MIXTURES LS-264 R27 ASTM D2041/D2041M

Pneumatic blending in a bin or silo that is, aerating. Saving time, labor, and money with pneumatic batch blending. Copyright CSC Publishing

Tensiometer For the measurement of surface and interfacial tension

CIA-EA Technical Data Sheet

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

HEALTH & SAFETY DATA SHEET according 1907/2006/CE, Article 31

SPECIFYING MOTIONLESS MIXERS

Tensiometer For the measurement of surface and interfacial tension

Rheological properties. Rheological instruments backed with rheological experience. Malvern. detailed specification sheets from

Corning Step-R. Repeating Pipettor. Instruction Manual

ELASTOMER PROCESSING

ROTARY VISCOMETER. Rotary Viscometers MYR V0/V1/V2 acc. to ISO 2555/ASTM (Brookfield method) SERIE VR 3000

HEALTH & SAFETY PRODUCT DATA SHEET

Laser Cutting. Nitrogen Solutions for

Gas mixtures. Individual solutions specifically for your application

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF SLURRY RHEOLOGY METHOD: T WP

ASPHALT PLANT LEVEL 1

ON WATER DISPERSIBLE GRANULES (WG)

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Improve Process Reliability

Matrix Blend Series. Technical Information. Properties. Description. Advantages

Determination of density by volumetric displacement Skeleton density by gas pycnometry

Reinforce design of experiments theory Make individual factorial designs and conduct analysis on responses

Assembly drawing and the names of features

VOLUMETRIC TECHNIQUES

CubeSat Balloon Drag Devices: Meeting the 25-Year De-Orbit Requirement

7.9. Flash Column Chromatography Guide

BRINGING A NEW DIMENSION TO PIPELINE PIGGING. By: David Aitken, Aubin Group, UK

Drilling Efficiency Utilizing Coriolis Flow Technology

Part No , Electrode filling solution 3M KCl Revision date: 29/07/2014

Gas Laws. Introduction

INTERNATIONAL STANDARD

SAFETY DATA SHEET GREEN HMP

Measurement & Analytics Wet gas monitoring

Structure of Mechanically Agitated Gas-Liquid Contactors

Micro Motion 3098 Gas Specific Gravity Meter

JetVent SAFE, AUTOMATIC PRESSURIZED CONTAINMENT.

and T urnkey P rojects

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

All hoses are not the same. ERIKS Hose Technology

IN-PLACE DENSITY OF BITUMINOUS MIXES USING THE NUCLEAR MOISTURE-DENSITY GAUGE FOP FOR WAQTC TM 8

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Aug 17, 2001 LAB MANUAL MAXIMUM SPECIFIC GRAVITY (RICE VOIDS TEST) OF PAVING MIXTURES AASHTO Designation T 209 (Mn/DOT Modified))

CFD for Ballast Water & Bio-fouling Management

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

CHANGE RECORDS TABLE OF CONTENTS

CoriolisMaster mass flowmeter Diagnostics, verification and proof test

Basic Flows in a Microfluidic Device

Inspection and Approval of Asphalt Mix Design Laboratories

SOLAR ENERGY. solutions. adhesives, sealants, and Potting encapsulants For solar energy applications

Pipette apparatus. Meet the difference. Manual. T E I

BUZWAIR CARBON DIOXIDE

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

v /07/17 Page 1 of 18

THE NATURAL CHOICE. High end valves for the natural gas value chain. Inspired By Challenge

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

DETERMINING OPTIMUM RESIDUAL ASPHALT CONTENT (RAC) FOR POLYMER-MODIFIED SLURRY SEAL (MICROSURFACING) MIXTURES

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

IN-PLACE DENSITY AND MOISTURE CONTENT OF SOIL AND SOIL- AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) FOP FOR AASHTO T 310

BULK SOLIDS HANDLING Valve Solutions Unlock the Potential

1. If grams of the vapor of a volatile liquid can fill a 498 ml flask at o C and 775 mm Hg, what is the molecular mass of the gas?

APPLICATION NOTE. GC Integrated Permeation Device

Mix and Flow of Matter Grade 8 Unit 1 Test

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

VISIMIX LAMINAR. BLENDING OF NON-NEWTONIAN LIQUID. POWER. CIRCULATION. MIXING TIME.

Rotary Viscometers Rotary viscosimeters ST-2020

Non-Lethal Blunt Trauma Grenade Performance Improvement

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

ASPHALT PLANT LEVEL 1

Real World Metric System

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

RayPette Plus Autoclavable Pipette. User Manual

Tissue-Tek Prisma Plus & Tissue-Tek Glas TM g2

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Inspection and Acceptance of Asphalt Mix Design Laboratories

Science 8 B Topic 4-6 Flow Rate and Viscosity fluids resistance to flow viscosity viscous higher viscosity it has liquids and gases

Soil water retention determination using the Wetlab facility at CSIRO, Davies Laboratory

TEMPLE UNIVERSITY A Commonwealth University Environmental Health & Radiation Safety (EHRS)

Density, Pressure Learning Outcomes

Tex-206-F, Compacting Specimens Using the Texas Gyratory Compactor (TGC)

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

Safety Data Sheet. acc. to OSHA HCS. 2: Hazard(s) identification. Page 1/6 Printing date 10/26/2015 Reviewed on 10/26/2015. * 1: Identification

Operating Instructions

Setting a New Standard in Flash Chromatography Performance

v1.4 RS - Safety data sheet according to 1907/2006/EC, Article 31 Version number 3

Pipettor. User Manual

CHM Introductory Laboratory Experiment (r17sd) 1/13

CHM250 Calibration and Measurement Lab. Balance Calibration

The pipettes cover a volume range from 0.1µl to 10ml.

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION

OPERATOR, PRODUCT AND ENVIRONMENTAL PROTECTION

Standard Flexel 3D bioprocessing bags for Palletank

Density, Pressure Learning Outcomes

cobi Collaborative seating

ISO 9597 INTERNATIONAL STANDARD. Cement Test methods Determination of setting time and soundness

Transcription:

OPTIONS LABORATORY CALEVA MIXER - GRANULATOR - BLENDER Effectively mix, blend or granulate small batches of your powders, wet masses, gels, waxes, slurries and pastes and other similar materials on your bench top OPTIONS AND COMPANION EQUIPMENT One unit, many uses 1

IF YOU WANT TO... THEN YOU SHOULD... DE-LUMPING AND DE-AGGLOMERATION OF COMPACTED PRODUCTS De-lump or de-aggregate compacted product before use. Consider the standard high shear bowl and blades running at high speed as this will often completely separate compacted powders. Allow us to try it with your troublesome products. BLENDING MIXTURES OF VISCOUS LIQUIDS Blend viscous liquids in various proportions without incorporating excess air bubbles. The standard high shear bowl and blades running at low speed will efficiently blend viscous liquids. Mixing slowly will gently blend the liquids together without dragging excessive air into the mix. If the liquids are very viscous then consider the sigma blades as an option. BLEND POWDER MIXERS OR BLEND SMALL QUANTITIES LIQUIDS THROUGHOUT A SOLID MATRIX Blend and mix two dry powders in Powders can be mixed very quickly with the high shear proportions ranging from 1:1 to about 100:1. blades running a high speed. About 1 minute of mixing is often sufficient to give a homogeneous mix. Disperse small quantity of a liquid evenly through a powder matrix. Disperse small quantity of a waxy solid evenly through a dry powder matrix. Use the standard bowl and blade set choosing the size to suit your batch size. Mix the powder at high speed and slowly add the right amount of liquid with a 1ml (or less) syringe. Mix at the highest speed with the standard bowl and blade set whist adding the warmed (and liquid) wax. GRANULATION OF SMALL BATCHES Examine the effect of adding different This will give you a qualitative indication but this will amounts of liquid binder or mixing a set not be as accurate or as useful as using the Caleva amount of binder for different times. Mixer Torque Rheometer that is designed specifically for this use. ADD OR REMOVE HEAT FROM THE MIXING CHAMBER Add or remove heat from the mixing process. Consider the use of mixing bowls with optional water jackets. These can be used to add or move heat to or from the mixing bowl to give the results that you need. THE MOST FLEXIBLE AND ADAPTABLE SMALL MIXER FOR YOUR LABORATORY 2

OPTIONS The base unit is supplied as a stand alone unit. At least one mixing bowl and blade set must be selected for the system to operate. There is a range of optional bowls and blades. The most appropriate for your needs will depend on the characteristics of your products and what is that you want to achieve with them. In some cases more than one bowl may be recommended to enhance the process options that are available to you. The range of options is given below. BOWL CONFIGURATIONS Full size bowl Mixing chamber open volume with blades inserted: 275 cc without insert, 241 cc with insert. This is not the operating volume (batch size) as this will depend on the characteristics of the material being mixed and it will be less than this. Main uses: Mixing of suitable materials where high shear and maximum mixing activity is required in larger batches. Examples would be granulation to develop wet masses, high efficiency mixing of powders of similar or very different batch sizes, high shear mixing of powders with waxy solids that require melting before mixing. Any other mixing that required high efficiency and rapid action Our recommendation: This is the standard and most versatile set-up.if you are unclear and wish to have the widest range of operating options available. Other comments: Can be used with or without the insert depending on batch sizes. Batch sizes can generally be from approximately 30 to 140 grams. These figures cannot be exact for all materials of varying bulk density and are given as a guide only. A typical mix application where a mix of two dissimilar powder components are mixed with a 4% liquid binder (with food colour added to check liquid dispersion). Used without the insert. Full size bowl with water jacket Used as above but in situations where heat has to be added to, or removed from the mixing system. Reduced size bowl Mixing chamber open volume with blades inserted: 71 cc without Full size and reduced size bowls insert and 52 ml with insert. Used as above but when working with smaller batch sizes (from about 10 g). 3

Reduced size bowl with water jacket and insert Mixing chamber open volumewith blades and insert inserted: 52 cc Used as above but when working with smaller batch sizes (from about 10 g) and where it is required to remove, or add heat to the mixing system Full sized bowl with Sigma blades Mixing chamber open volume with blades inserted: 113 cc without insert, 74 cc with insert. Main uses: The sigma blade system is designed for mixing and granulation of materials that are highly viscous. Many petrochemical and catalyst products are highly viscous and this efficient low shear mixer system works better with this type of material. Mixing in thorough but sometimes a little more time is required for he mixing to complete. Our recommendation: If you have materials that might become quite stiff with a very low viscosity then the sigma bowl and blade set is likely to be your preferred choice. Reduced size standard bowl and blade set with water jacket and insert. Full size sigma blade and bowl set bowl and blade set without jacket Full size bowl with sigma blades with water jacket Open volume with blades inserted:113 cc without insert, 74 cc with insert. Used as above but in situations where heat has to be added to, or removed from the mixing system. Sigma blades Reduced height standard blades An additional advantage of the smaller sized bowls: For some applications where an increase in mixing power is needed (for example in the case of very stiff materials) then a smaller bowl might provide a solution. Using the smallest bowl and using smaller blades relatively provides more power to be applied to a smaller mixing surface. Mixing bowls can be used with or without inserts as required. In the case of very scarce or expensive materials then a small bowl will help to run trials with smaller amounts of material. 4

ADDITIONAL ATTACHMENTS AVAILABLE FOR THE BASE UNIT. EXTRUDER ATTACHMENT An extruder attachment is available to enhance and widen the range of applications that are possible for the Caleva Mixer - Blender - Granulator A small extruder with options for dies with holes of different depths, diameters and hole types is available to enhance the utility of the base unit. This extruder will work effectively with batches from about 5 grams. Contact us for additional details or if you want discover if this is suitable for your product and what you are trying to achieve or if you want to try your product and application in our laboratory. SPHERONIZER ATTACHMENT A spheronizer attachment is available for use with the same base unit. Spheronization (sometimes call Marumerization or Spheroidization) is the process widely used to produce small round pellets of many materials in many industries such as cosmetics, pharmaceutical, catalyst, industrial chemistry, foods etc. If you think this process might be suitable for your needs contact us without any obligation for a discussion and our best advice. 5

COMPANION EQUIPMENT CALEVA MINI COATER DRIER Coating small batches of pellets If you are producing small quantities of pellets with the Caleva Multi Lab and these require drying or coating then the only drying and spraying equipment that can operate with such small sample sizes is the Caleva Mini Coater Drier. Small quantities of spheroids (from a few grams) can be coated and dried in minutes. Other pellet coaters might require a minimum batch of between 300 g and 500 g to work effectively, but this robust, simple-to-operate, bench-top unit provides a cost-effective solution for drying and coating particles. The practical unit, which is fully compliant with principles of GLP, can satisfy other applications such as the experimental coating of granules with catalytic material, food material and fluid-filled gelatine capsules. Please talk to us for more information. CALEVA MIXER TORQUE RHEOMETER The Caleva MTR is well established as a valuable formulation development, formulation research and production quality control tool It provides a quantitative and reproducible measurement of the wet mass in terms of the torque produced when shearing the granulation within the pivoted mixing bowl. This ability allows formulations to be optimised and product and excipient quality issues to be identified. A valuable tool for formulation development. Please talk to us about the Mixer Torque Rheometer and ask us about available case studies. 6

VALIDATION AND TRAINING INSTALLATION AND TRAINING AT THE CUSTOMER SITE Training can be arranged within the UK, any other European country or outside Europe Including one day installation and training and up to four days travelling depending on the location. Includes installation, commissioning and training at customer site of up to one day, but does not include IQ/OQ which is separately chargeable. The customer will assist with local transport for the Caleva technician if required (generally not required). The customer will supply the consumable products as required. FACTORY ACCEPTANCE TEST AT THE CALEVA SITE We make our own quality check before the equipment is shipped (a copy is supplied to the customer) and thus a separate FAT is not normally necessary but can be completed with the customer if required. CUSTOMER TRAINING AT THE CALEVA SITE (OVERSEAS CUSTOMERS) Training is recommended if extrusion and spheronization is a relatively new technique to the company or if new staff would benefit from it. Customers from outside the UK can be collected at any London main airport, accommodation and all meals for one trainee whilst with Caleva. Transport to and from the Caleva site is included. Any extras (such as phone calls etc.) at hotel are for guest s account. One night bed & breakfast in London hotel before return flight to home country can be included if requested. Up to two days training (as required) at the Caleva site on customer s own equipment prior to shipment. If more than one item is purchased then training can be done together with considerable savings in cost. Contact us for details. VALIDATION AND IQ/OQ DOCUMENTATION PACKAGE Recommended if required for regulatory purposes. At Caleva site The IQ/OQ package can be completed at the Caleva site by us in so far as this is practically possible. The customer can attend if he or she wishes to do so at their own cost. An additional set of blank documents will be provided to allow the customer to re-do the IQ/OQ in their own facility. At customer site IQ/OQ and installation completed at the customer site at the same time as installation and training (training will be charged separately). The cost shown is an additional cost for the IQ/OQ in addition to the costs for installation and training. 7

MATERIAL CERTIFICATES (INCLUDED IN IQ/OQ) In line with current standards Caleva does not automatically supply copies of material certificates for product contact parts. Caleva can provide free of charge a certificate naming the product contact parts and confirming that we or our suppliers can provide full traceability to original certificates if this is requested. If certified copies of material certificates are required then these can be provided at an additional cost. TALK TO US Please call us without obligation +44 (0) 1258 471122 info@caleva.com Cert No. 1503 ISO 9001 8 Ver 70427