PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

Similar documents
Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

Measuring Carbon Dioxide in Breath

Before you start sampling, be sure to read

Gas Laws. 2 HCl(aq) + CaCO 3 (s) H 2 O(l) + CO 2 (g) + CaCl 2 (aq) HCl(aq) + NaHCO 3 (s) H 2 O(l) + CO 2 (g) + NaCl(aq)

Experiment 18 Properties of Gases

Properties of Gases Observing Atom Pressure of a Gas Measuring Gas Products of Chemical Inferring Molecule Reactions

PREPARATION AND PROPERTIES OF ATMOSPHERIC GASES I: Carbon Dioxide and Oxygen

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

ExamLearn.ie. The Air & Oxygen

VOLUMETRIC TECHNIQUES

General Chemistry I Percent Yield of Hydrogen Gas From Magnesium and HCl

Please do not write on this test. Please use the answer sheet. 1) Please choose all conditions that would allow a gas sample to behave ideally.

CO 2 and Mass Chemistry

Gas Laws. Figure 1: Experimental Set-up with Leveling Bulb. GCC CHM 151LL: Gas Laws GCC, 2019 page 1 of 8

D. De La Matter 2004 Swimming Pool Chemistry STUDENT ACTIVITIES:

MassWWP Standard Operating Procedure R-2 Dissolved Oxygen Rev.0 Page 1 of 10

Name Gas Law Date. Version 3

The Ideal Gas Constant

Figure. Experimental set up of catalyst, reactants and product syringes.

The Determination of the Value for Molar Volume

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

Unblocking the MicroSprayer Aerosolizer Model IA-1B With the High Pressure Reverse Cleaning Adapter. Instructions for Use

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

Additional Reading General, Organic and Biological Chemistry, by Timberlake, chapter 8.

R: The Ideal Gas Constant Pre-Lab Assignment

CHM250 Calibration and Measurement Lab. Balance Calibration

TEV-TROPIN [somatropin (rdna origin) for injection] 5 mg & 10 mg

Determination of the Percentage Oxygen in Air

Name:. Correct Questions = Wrong Questions =.. Unattempt Questions = Marks =

Lab Equipment ANALYTICAL BALANCE

Name:. Correct Questions = Wrong Questions =.. Unattempt Questions = Marks =

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point.

The Decomposition of Potassium Chlorate

EXPERIMENT. Identification of Gases

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

1. Determining Solution Concentration

CHEM 321 Experiment 1

The Decomposition of Hydrogen Peroxide

Any laboratory is equipped with specific tools, equipment,

Table Animation 17 Observe the behavior of a mixture of nonreacting gases. Section Resources

LABORATORY TECHNIQUES. Pouring Liquids

Pipetting Small Volumes

CH2250: Techniques in Laboratory Chemistry. Outline Measuring Mass Measuring Volume Significant figures. Mass Measurement

MOLEBIO LAB #1: Microquantity Measurement

Intermolecular Forces

Determination of the Gas-Law Constant (R) using CO2

1. Quantity of a gas (moles) 2. Temperature of the gas. 3. Volume occupied by the gas. 4. Pressure exerted by the gas. PV = nrt

PARTICLE SPACING PART 1

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Blue Thumb Test Procedures

CHM 317H1S Winter Section P Procedures and Tables

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

The Determination of the Value for Molar Volume

BASIC LABORATORY TECHNIQUES (Revised )

GAS LAW WORKSHEET 1 KEY

Please do not write on this test. Please use the answer sheet.

Patients Guide for Self Administering Intravenous Antibiotics General points

Accelerated Chemistry Study Guide Chapter 13: Gases

BOYLE S / CHARLES LAW APPARATUS - 1m long

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

Gas Laws Chapter 14. Complete the following pressure conversion. Be sure to show how units cancel.

Multiple Choice (40%)

Script. for Chemsations Demonstration Show

Part II. Under Construction Station Instructions. Lab Station A - Blue Print: There is O 2 Here!

Aerobic Respiration. Evaluation copy

Unit 11 Gas Laws Chapters 13 of your textbook

Experiment 12: MOLAR VOLUME OF AN IDEAL GAS

Students measure the change in pressure by varying the volume of trapped air in a syringe while:

Setting up and running a column

Dr. Rogers Chapter 5 Homework Chem 111 Fall 2003

DURING the course of certain investigations it became

THE DECOMPOSITION OF POTASSIUM CHLORATE This lab is derived almost entirely from a lab used at the United States Naval Academy

Calibration of Volumetric Glassware

CHM Introductory Laboratory Experiment (r17sd) 1/13

Studying Carbon Dioxide

General Safety Rules

Measuring Mass and Volume

BASIC LABORATORY TECHNIQUES (Revised )

Fish Farming Water Quality Test Kit

Gas Laws. Introduction

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

In case of emergency or accident: 1. Call the instructor immediately. Describe the nature of the accident or injury.

RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

The use of the analytical balance, and the buret.

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

Analysis of Deuterium Enrichment by Fourier Transform Infrared Spectrometry (FTIR): Practice. Christine Slater PhD

Check-In, Lab Safety, Balance and Volumetric Glassware Use, Introduction to Statistics, and MSDS Familiarization

EXPERIMENT 1 TOOLS FOR LAB MEASUREMENT

Ch. 2: Tools of the Trade

Dissolved Oxygen Study Manual

Chemistry Safety Packet

Vapor Pressure of Liquids

Read ENTIRE lab up to Disposal Section. MAKE NOTES!!! **For Procedures, Highlight equipment used and circle quantities measured out.

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

1. PRODUCT IDENTIFICATION 2. COMPOSITION / INFORMATION ON HAZARDOUS INGREDIENTS

Cooling Gases Phase Changes and Phase Diagrams

SodaStream is the modern way to enjoy delicious bubbles. without the bottles. No more lugging or storing heavy

LAB 06 Organismal Respiration

To derive from experiment the relationships between Pressure (P), Volume (V), Temperature (T), and Water Solubility of gases.

Transcription:

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES A wide variety of gases can be prepared safely inside a 60 ml plastic syringe. Here you will practice making carbon dioxide, so that you know the technique when you make more difficult gases. The general strategy of the method is to react two substances in a 60-mL syringe. The limiting reagent is always used in solid form and is placed in a small vial cap. The second reagent is prepared as an aqueous solution. For example, one could generate CO 2 (g) from excess aqueous acetic acid and solid NaHCO 3, as the limiting reagent. When you take the written portion of the lab final, you will be allowed to use your lab notebook pages. Take good notes and make careful observations! Making Carbon dioxide. 1. The solid reagent. Measure out 0.21 g NaHCO 3 directly into the vial cap. Hint: Cut the top off of a plastic pipet at an angle to make an inexpensive spatula. Fill the syringe barrel with water. Place your finger over the hole to form a seal. Fill completely to the top. Float the vial cap containing the solid reagent on the water surface. This is easiest if the syringe barrel is filled completely to the top with water. Lower the cap by flotation. Release the seal made by finger to lower the cap into the syringe barrel without spilling its contents. Allow the syringe to drain into a wide mouth beverage container. When successfully completed, the cap should rest upright on the bottom of a syringe with all reagent still in the cap. The syringe should always be held in a vertical position during these first steps. Install the plunger while maintaining the syringe in a vertical position. The plunger should fit snugly against the rim of the vial cap. 1

The aqueous reagent. The liquid reagent is drawn into the syringe as described below. We will use 5 ml vinegar, HC 2 H 3 O 2, to make carbon dioxide. The liquid reagent is always the reagent in excess. Draw aqueous reagent into syringe. The aqueous reagent, measured into a small weighing boat, is drawn into the syringe while maintaining the vertical position of the syringe. The vial cap with the solid reagent should float on the solution. Push the syringe cap over the syringe fitting. It simply pushes on! Generating the Gas. The fun part is generating the gas and you are ready to do that now! Shake the device up and down in order to mix the reagents. As the liquid reagent splashes into the vial cap, gas generation will commence and the syringe plunger should rise. It is sometimes necessary to gently help the plunger move up the barrel. Remove cap to stop the reaction. After the plunger has reached the desired mark (usually 50-mL), tip the syringe so that it is positioned with plunger downward and syringe cap upward. Carefully remove the syringe cap assuming that the syringe may be under positive pressure. Discharge reagents. Turn the syringe 180 o and discharge the liquid reagent into the plastic cup. Caution: Never remove the syringe cap with the cap end of the syringe directed downward: Reagents will spray out of the syringe. Immediately cap the syringe with the syringe cap to prevent loss of gas by effusion or reaction with air. Prepare CO 2 and show TA for approval (Required before NO Prep) 2

Other useful gas syringe techniques. There are a several other techniques that come in handy when working with gases in syringes. Here are the ones you will find useful in the lab practical final. Practice these techniques today. A. Syringe-to-syringe Transfer procedure. It is often useful to transfer a gas from the syringe in which it was prepared to another clean, dry syringe. In the third step shown below, note that the clean, dry syringe is on top. 1. Connect a short piece of tubing to a clean syringe. 2. Connect gas-filled syringe to tubing: 3. Transfer the gas with clean, dry syringe on top: B. Controlled discharge of gas from a syringe. Plungers do not always move smoothly in their syringe barrels. As a result, gases may be discharged in large unintended portions (such as 40-mL all at once). This is more likely to occur if the method shown in the left diagram below is used. Instead, grasp the syringe by its plunger (right figure) and pull the barrel towards your hand. This simple technique will give you excellent control of gas delivery. INCORRECT WAY CORRECT WAY 3

C. Preventing unwanted discharges of noxious gas. Some of the gases that can be generated by the in-syringe method are noxious and should not be discharged into breathable air. These include nitrogen monoxide, NO, nitrogen dioxide, NO 2, both prepared in the lab practical final next week. The use of syringes to generate such gas samples works exceptionally well and far better than any other method in preventing undesired discharges. There are two simple considerations to keep in mind whenever handling noxious gases: (1) Whenever opening the syringe (by removing the syringe cap), do so with the plunger slightly withdrawn so the contents are under a slight negative pressure. Use your thumb to maintain the plunger in this position as shown in the drawing. This will allow a bit of air to enter the syringe but no gas will escape out; and (2) After the gas sample has been generated, discharge the used reagents into a large cup of water to dilute them and prevent further reaction. D. Safety First. Cap Up and Off! The solid reagent is the limiting reagent. If you use too much of the solid, there is a chance that you will generate more than 60 ml gas. This should not happen if you measured your mass of reagent carefully. However, If it seems that more than 60 ml gas is going to be generated, follow these steps. 1. Hold the syringe so the cap is directed upward. 2. Remove the cap by twisting. 3. Discharge the solution to prevent further gas collection. 4. Recap syringe. E. Clean-up and Storage At the end of the experiments, clean the syringe parts, caps and tubing with water. Rinse all parts with distilled water. Be careful with the small parts because they can easily be lost down the drain. Important: Store plunger out of barrel unless both are completely dry. 4

Preparation of nitrogen monoxide and its reaction chemistry. In this experiment, you will prepare nitrogen monoxide gas in a syringe and perform a series of reactions. The common name for nitrogen monoxide is nitric oxide. Take thorough notes in your laboratory notebook and make sure you understand everything as you go. Record all masses, volumes, and observations! When you are finished, you will take a quiz over the experiment. You will be allowed to use your laboratory notebook. A periodic table will be provided. You will not be allowed to use these instructions or any other materials. You will need a calculator. The preparation of nitrogen monoxide utilizes the following reaction. Using the quantities stated below, sodium nitrite is the limiting reagent. 2 NaNO 2 (s) + 2 FeSO 4 (aq) + 3 H 2 SO 4 (aq) à 2 NO(g) + Fe 2 (SO 4 ) 3 (aq) + 2 NaHSO 4 (aq) + 2 H 2 O(l) Part A. Preparation of nitrogen monoxide Each NO(g) preparation uses 0.25 g solid NaNO 2 and about of 5 ml of the acidic ferrous sulfate solution. You will not be given this solution until you have successfully prepared CO 2 and have instructor s initials. 1. Wear your safety glasses! 2. Measure out approximately 0.25 g solid NaNO 2 using the analytical balance. Place the solid directly into the vial cap to prevent loss. 3. Fill the syringe barrel with water. Place your finger over the hole to form a seal. 4. Float the vial cap containing the solid reagent on the water surface. 5. Lower the cap by flotation. Release the seal made by finger to lower the cap into the syringe barrel without spilling its contents. 6. Install the plunger while maintaining the syringe in a vertical position, supported by the wide-mouth beverage bottle or flask. 5

7. Fill the weighing dish with the Acidic Ferrous Sulfate Solution. Draw 5 ml of this solution into the syringe. 8. Push the syringe fitting into the syringe cap. 9. Shake the device up and down in order to mix the reagents. Gently help the plunger move up the barrel. Upon mixing the reagents in the syringe with vigorous shaking, gaseous NO is quickly produced. Pure nitrogen monoxide is colorless. A trace of reddish NO 2 is observed at first but soon disappears. The aqueous solution turns black in color. 10. Fill your plastic cup 1/4 full with tap water. With the plunger slightly withdrawn (about 2 ml past from where it stopped) to assure reduced pressure inside the syringe, and with the syringe held cap-up, remove the syringe cap. 11. Discharge the liquid reagent into a cup of water. Immediately cap the syringe to prevent loss of gas. Transfer the liquid into the recovered acids container. 12. With the aid of a short length of Latex tubing, transfer the nitric oxide to a clean, dry syringe. Remember: Clean, dry syringe is on top! 13. (5 pts) Show the gas to your instructor who will evaluate your gas sample. [ ] Gas is colorless [ ] At least 40 ml produced Points: [ ] Syringe clean, dry [ ] Passes NO test Initials: Part B. Preparation of nitrogen dioxide Do not start this section until you have completed Step 13 above with a score of 4 or better. Nitrogen dioxide is prepared by reacting nitrogen monoxide with oxygen gas: 2 NO(g) + O 2 (g) à 2 NO 2 (g) 1. Your nitrogen monoxide sample must be in a clean, dry syringe. Nitrogen monoxide is not water soluble, but nitrogen dioxide is very soluble in water. 2. Clean and dry the syringe used to prepare NO(g). Bring it to your instructor who will fill it with oxygen. 6

3. Connect the oxygen syringe to the nitrogen monoxide-filled syringe. 4. Hold the plunger of the nitrogen monoxide syringe firmly in place (so it cannot easily move in the barrel), and gently push the plunger of the oxygen syringe inward. Sometimes the oxygen syringe plunger will move inward by itself. Eventually the oxygen syringe plunger will not easily move any further. The pressure inside the two syringes is about the same as the external pressure. 5. When the reaction is complete, pull the plunger of the syringe now containing nitrogen dioxide outward about 3 ml and then remove the connector tube and immediately cap the NO 2 (g) syringe. 6. (3 pts) Show the gas to your instructor who will evaluate your gas sample. [ ] Gas passes inspection [ ] At least 40 ml produced Points: [ ] Syringe clean, dry Initials: Part C. Preparation of nitric acid Nitric acid is prepared by reacting nitrogen dioxide with water: 3 NO 2 (g) + H 2 O(g) à 2 HNO 3 (aq) + NO(g) 1. Draw 5 ml distilled water into your syringe filled with nitrogen dioxide. Shake the mixture. How do you know a reaction occurred? How do you know it is over? 2. Draw some air (10 ml) into the syringe. Are these results expected? 3. Discharge the solution into a cup containing 20 ml distilled water. Add a drop of phenolphthalein and titrate to a pink endpoint by adding drops of 1 M NaOH. Count the drops. You can assume there are about 20 drops per ml. 4. Dispose of contents down the drain. 7