Lubricated TC Models

Similar documents
AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

SILENTAIRE TECHNOLOGY

SILENTAIRE TECHNOLOGY

AMS SUPER SILENT COMPRESSOR USER & MAINTENANCE GUIDE

Budget Range Operators Handbook

COMPRESSOR MANUAL. (888)

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

444C DUAL PERFORMANCE VALUE PACK

MD R a n g e O p e r a t o r s H a n d b o o k

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

100C Air Compressor Kit

200 PSI COMPRESSORS - MODEL NUMBERS

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Model PSI Compressor with 3-Gallon Air Tank 12VDC

400C & 450C DUAL PERFORMANCE VALUE PACKS

Code AWC20HP Air Compressor

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

IMPORTANT SAFETY INSTRUCTIONS

200 PSI FAST-FILL AIR SOURCE KIT

R E D I C O N T R O L S

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

8-gallon Air Compressor. Owner s Manual

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

200 PSI HIGH-FLOW AIR SOURCE KIT

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Portable Oil Lube Air Compressors

OPERATOR S MANUAL 1.5 HP/6-GALLON 6 GAL AIR COMPRESSOR IMPORTANT: READ OPERATOR S MANUAL BEFORE USING. Toll Free Helpline:

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

PC1131 Electric Air Compressor

IMPORTANT SAFETY INSTRUCTIONS

Freedom8 ShoeBox Compressor Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

DeVILBISS AIR POWER COMPANY. OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR (For Home Use Only) MODEL NO. DFAC153 SPECIFICATION CHART

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

accidents which arise due to non-observance of these instructions and the safety information herein.

User Instruction Manual

480C DUAL PERFORMANCE VALUE PACK

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

DUAL 444C ONBOARD AIR SYSTEM

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

MODEL NUMBER: P PORTABLE COMPRESSOR

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

FACTORY SERVICED 8 Gallon Air Compressor. Model: Important Safety Instructions RISK OF EXPLOSION OR FIRE:

1 HP / 1.6 GALLON AIR COMPRESSOR OPERATING MANUAL

MODEL NUMBER: P PORTABLE COMPRESSOR

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

2 Gallon Air Compressor

VERTICAL AIR COMPRESSORS

Air Compressor Electric Handheld

SC6H OIL-LESS AIR COMPRESSOR

200L BELT DRIVEN AIR COMPRESSOR

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

D Series Air and Water Kit Part# 02550

AIR COMPRESSOR INSTRUCTION MANUAL. model no

ULTRA QUIET & OIL FREE

General Safety. All electrical work

VERTICAL AIR COMPRESSORS

Universal Valve Company Inc

20 Gallon Air Compressor

Universal Valve Company Inc

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

2 HP / 4 GALLON AIR COMPRESSOR OPERATING MANUAL

50L BELT DRIVEN AIR COMPRESSOR

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

24 Litre Air Compressor

Dual 280C Onboard Air System (Black on Silver) Dual 380C Onboard Air System (Chrome) Dual 380C Onboard Air System (Stealth Black)

6 GAL PORTABLE OIL FREE AIR COMPRESSOR

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Instruction manual. Pancake Compressor ESPAÑOL: PÁGINA 19 FRANÇAISE: PAGE 37 MODEL CPF23400P

Vessel Installation and Operating Manual

20 GAL OIL FREE AIR COMPRESSOR

REDUCER REDUCER REDUCER

ULTRA-QUIET 4 GALLON PORTABLE AIR COMPRESSOR

Marschalk Model # 94000

INSTRUCTION MANUAL 8 U.S. GALLON (30.3 L) AIR COMPRESSOR

21 Gallon. Model Visit our website at:

J Air and Water Kit Instructions Part# 02584

PC 1010 Electric Air Compressor

AC558RB AC7011RB. operation manual

EGL-12 OIL-LESS COMPRESSOR

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

AIR COMPRESSOR INSTRUCTION MANUAL. model no

Installation and Operating Manual

RG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free

Transcription:

Lubricated TC Models P 15 TC P 30 TC P 50 TC+AL General User and Maintenance Instructions Werther International, Inc 8614 Veterans Memorial Houston, TX 77088 832-327-9378 Fax 832-327-0669

Thank you and congratulations on the purchase of your PANTHER, the leader in the industry of portable air compressors. The PANTHER is built to the highest quality standards which produces excellent efficiency. If you use it properly and maintain it according to this manual, it will perform to your fullest satisfaction for many years to come. Please read this manual carefully and follow the instructions, it will guarantee you a troublefree operation. A. Installation 1. After taking your lubricated PANTHER Model out of its packaging, please check it carefully for any damages due to shipping. 2. Install the compressor on a flat surface in a suitably sized, dry room with good ventilation, where the temperature is not likely to rise above 94 Degrees Fahrenheit (35 Centigrades). 4. Dispose of the Packing Material in compliance with the regulations in the country or state where the compressor is installed. B. Safety 1. Do not use the lubricated PANTHER Models for purposes other than those for which they have been designed. 2. Do not modify or repair the compressor while it is connected to the electric current or while the tank is still pressurized. This "bolt of lightning" indicates uninsulated material within your unit may cause an electrical shock. For the safety of everyone please do not remove product covering. The "exclamation point" calls attention to features for which you should read the enclosed literature closely to prevent operatiing and maintenance problems. WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE..

- 2 - C. Operating Instructions Fig. 1 Fig. 2 Fig. 3 1. Check that the automatic ON/OFF-Pressure Switch is in the OFF-position (or turned fully counter-clockwise, Fig. 1). 2. The lubricated PANTHER Compressors are available in the following different Models: P 15 TC, P 30 TC, P 50 TC+AL. All these models are available in the 115V/60Hz-version. On special request most of these models can also be delivered in the 230V/60Hz version. Note: Check to see if the outlet of your electric supply corresponds to your compressor version. 3. Remove and store the plastic cap from the suction tube (P 15 TC, P 30 TC) according to Fig. 2, or from the hole for the air-filter in the cover of the compressor pump (P 50 TC+AL) according to Fig. 3. 4. Fill oil from the supplied bottle containing a special oil for the lubricated PANTHER compressors. To the Models P 15 TC and P 30 TC fill the oil through the suction tube (Fig. 2), to the P 50 TC+AL fill it into the hole of the compressor cover (Fig. 3) until the filled-in oil reaches the mid-point level of the oil sight glass in the housing of the compressor pump. Store the rest of the oil for the next oil change. Note: Never use oil different from the recommended oil by the manufacturer, as this will void all warranties. Overfilling with oil and turning the compressor upside down will cause the oil to spill out of the compressor. 5. Remove the Air-Intake Filter (Fig. 4) from the supplied plastic bag and insert it into the suction tube (P 15 TC and P 30 TC, Fig. 2) or into the hole of the compressor cover (Fig. 3, P 50 TC+AL) using normal hand pressure. 6. Connect the equipment for your application to the outgoing 1/4" male fitting on the Filter/Regulator (Fig. 5). To keep the connecting fitting from leaking air you should always apply Teflon Tape to the thread of the fitting.

- 3-7. Plug the cord into a properly installed and grounded outlet of electric supply corresponding to the electric version of your purchased PANTHER compressor (for your own safety the unit should be grounded; in the event of a short this reduces the risk of an electric shock). If you need an extension cord to operate the unit, only use a heavy duty extension cord, no longer than 20 feet or 6,0 m (no household cord; it might cause a loss of power and the damage of electrical components). Note: Tampering with the Power Cord or Grounding Terminal will void all warranties. 8. Turn the knob on the automatic ON/OFF-Pressure Switch to the On-position (clockwise) until it stops (Fig. 1). The Pressure Switch has been set to automatically start and stop the compressor at the preset pressure level. Leave it in the ON-position until you want to turn off your compressor. Note: Never remove or repair the ON/OFF switch while the compressor is connected to the electric outlet! 9. After the compressor has run for a complete cycle to pressurize the tank and then shut off, you set the desired pressure with the Filter/Regulator (Fig. 5). Simply lift the knob on it until it unlocks, then turn it clockwise to increase the pressure.until the Pressure Gauge on the Filter/Regulator shows the desired pressure. To reduce the pressure also lift the knob on the Filter/ Regulator and turn it counterclockwise. Note: Never open the Filter/Regulator completely, it would ruin your compressor in a short period of time. If you notice that your compressor is running with a cycle of more than 50 % of the time, this indicates that you might have an air-leak in your system or that your compressor is too small for your application. 10. To turn off your compressor, simply turn the knob on the Pressure Switch (Fig. 1) to the OFF-position (counterclockwise). If the electrical power is interrupted while the compressor is in operation and it fails to restart after the power comes back on, turn the knob on the Pressure Switch to the OFFposition; this will release any pressure in the line and enable the compressor to restart again.

- 4 - Fig. 4 Fig. 5 Note: The Safety Relief Valve is a standard feature on your compressor. This valve opens automatically if the tank pressure goes beyond a safe level. Do not attempt to adjust or remove this device! D. Maintenance On your PANTHER there are a few parts that need your attention for proper maintenance: 1. Air Intake Filter: 1. Unplug Power Cord. (Fig. 4) 2. Pull Air Intake Filter out of the suction tube (Fig. 2) or the hole in the cover of the pump (Fig. 3) and remove the insert from the inside of the filter. 3. If the insert is dirty, wash it properly with soapy water or replace it. 4. Reinstall the Air Intake Filter at its place. 2. Moisture Trap: If you use your compressor properly, the Moisture Trap (built into the Filter/Regulator, Fig. 5) will trap the moisture and dirt particles before releasing air into the line. Periodic checks for moisture should be done on a routine basis by looking at the clear bowl at the bottom side of the Filter/Regulator. Moisture can be removed by pressing up the valve core at the bottom of the bowl. If it should be necessary to remove the clear bowl for cleaning, you should be careful that the clear bowl doesn t contain any air under pressure at the moment you unscrew the clear bowl.

- 5-3. Pressure Tank: 1. Check the Pressure Tank daily for water inside. 2. Unplug the compressor and release all compressed air from the tank by opening the Drain Plug. 3. Tilt the unit towards the plug to allow the water to drain. 4. Air Hose and other accessories should also be drained on a regular basis 4. Oil Change: 1. Unplug Power Cord 2. Drain Tank by slowly opening drain valve (located at different places on the tank, according to the model of compressor). 3. Remove Air Intake Filter (on the P 15 TC and P 30 TC also the plastic hose). 4. Tilt compressor and drain all oil into a container. 5. Return the compressor into the normal upright position. 6. Refill new oil through suction tube (P 15 TC and P 30 TC, Fig. 2) or through hole in cover of the pump (P 50 TC+AL, Fig. 3). 7. Verify that the oil level is at mid level mark in the oil sight glass. 8. Reinstall the Air Intake Filter and the the plastic hose (only P 15 TC and P 30 TC, Fig. 2). 9. Plug Power Cord in again and continue using the Compressor.

- 6 - E. Troubleshooting For any kind of repair or replacement only use original PANTHER spare parts! They are available at every authorized service center. Imitation spare parts may irreparably damage your compressor. When asking for information or service please always quote the Model, Type and Serial-Number of your compressor. This information is on a label of your compressor. Symptom: Cause: Remedy: Compressor will not run No electric power supply, bad cord connection or incorrect extension cord Check outlet voltage, fuse and circuit breaker. Check cord connection for visible damage. If using an extension cord, check that it is for Heavy duty, grounded and UL-approved. Compressor runs but will not supply air Rattling noise during operation Milky oil in compressor Tank is fully pressurized Thermal Overload Pro- Tector Relay has tripped Pressure on the Filter/ Regulator not set properly Air Intake Filter clogged or not installed Air leaks Compressor Motor inside touching housing Oil has been contaminated with moisture or other foreign matter Use your equipment to lower pressure in tank. Wait 15 minutes and try starting again. If this solved the problem, make sure the compressor is in well ventilated area. Check for air leaks in your system. Set the pressure on the Filter/Regulator to the minimum pressure required for your equipment Reset Filter/Regulator to pressure required for your equipment. Clean Air Intake Filter or replace it. Check all the fittings, connectors and equipment for air leaks and repair. Close the pressure to your equipment by turning the knob on the Filter/Regulator all the way counterclockwise - if the tank holds the pressure, the leak is in your equipment, if the pressure on the Pressure Gauge at the Pressure Switch drops, the leak is somewhere on the compressor. Surface under compressor not leveled. Check oil level of pump and adjust if it s Necessary. Change oil oil needs to be replaced every 150 hours of use. Use only the special oil from Werther International.

- 7 - Air Tank not holding pressure when compressor is not running No pressure shows up on the Pressure Gauge of the Filter/Regulator Compressor operates very hot Check-Valve defective No equipment connected to compressor Filter/Regulator has not been adjusted Oil level is incorrect Too small non ventilated Area Undersized Model Leaks in installation Disconnect pressure hose at pump and check For leaking back into pump clean or replace The Check-Valve. Spray all connections and manifold with soap solution, reseal connections or replace defective parts. Connect equipment. Lift knob on the Filter/Regulator and turn it clockwise until the pressure on the Pressure Gauge shows the required pressure for your equipment (pressure should be set at the minimum pressure required). Fill compressor pump with oil until mid level on the oil sight glass. Install the compressor in a bigger area with better ventilation. Duty cycle of compressor should not exceed 50 % - if pump is running for 1 minute, it should stay off at least 1 minute before restarting. Check for air leaks in your installation. Check if the setting of the pressure on the Filter/Regulator corresponds to the minimum requirement of your equipment. If your PANTHER has a different symptom of a fault from the above troubleshooting chart-list, please contact a specialized technician.

- 8 - F. Limited Warranty The warranty is for the original purchaser. We will repair or replace, without charge, any part of a compressor we find to be defective in factory material or workmanship within one year of purchase. Warranty services are provided at our service facility located in Houston at the address shown below. You must pay all shipping and handling charges for your compressor. Any material that is shipped to Werther International Inc. without prior approval will not be accepted. This warranty does not cover your compressor if the Serial Number or Model Number is removed or illegible. Or, if your compressor is (a) damaged in transport, by fire, corrosion, moisture or any occurences beyond our control, (b) subjected to negligence or misuse, or (c) operated or maintained contrary to our instructions. We will not be liable for damage to persons or property, commercial loss or incidental or consequential damage due to a defective compressor. All implied warranties, including warranty of merchantability or fitness, are limited to the duration of this written warranty. However, some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitation may not apply to you. If you wish to obtain warranty service or further information concerning this warranty, contact: Werther International Inc. 8614 Veterans Memorial. Houston, Texas 77088 Phone: (832) 327-9378 FAX: (832) 327-0669 This warranty will be void unless the attached warranty registration card is completed and received by us within 30 days of the date of the original purchase.

Parts List PANTHER TC-Models B0420 Nut M6 UNI 5588 ZB C0001 Gasket Intake-Valve E59 C0002 Valve Plate cpl. E59 C0003 Gasket Exhaust-Valve E59 C0004 Clip for Terminal Bloc C0007 Cover to Terminal Bloc E59 + E88 C0008 Overload Protector E59 230V C0009 Relay Starting 230V E59 C0011 Filter Air-Intake C0013XX Pump Compressor E59 230V C0024 Plug for Oilfill C0025 Gasket Housing C0026 Gauge Pressure M1/8 -side 10 Bar d=40mm C0030 Closing Band E59 and E88 C0034 Strain Relief C0037 Bolt M6x20mm UNI 5931 C0047 Fitting M5 d=6mm C0048 Switch Pressure 4-P 230V MDR 2/11 C0048-1 Switch Pressure for P 15TC C0049 Plug ¼ C0051 Hose Nylon 6/4mm C0052 Gasket Intake-Valve E88 C0053 Valve Plate cpl. E88 C0054 Gasket Exhaust-Valve E88 C0055 Relay Starting 230V E88 C0056 Overload Protector 230V E88 C0059 Fitting Extension M1/4 -F1/4 C0065 Fitting L Rotating M1/4-6,3mm C0067 Bolt TE M8x35mm UNI 5739 C0068 Power Cord 230V Euro-Plug C0077 Fitting Swivel Connector M1/4

Parts List PANTHER TC-Models C0080XX Pump Compressor 230V E88 C0091 Cable Electric 230V 500mm C0093 Cover for Terminal Bloc T2134 A+AL C0100 Washer 8,4x16x1,5mm UNI 6592 ZB C0102 Cap Plastic Transparent C0105 Bolt M8x30mm C0106 Spacer T2134 C0108 Terminal Bloc C0109 Bracket for Capacitor C0110 Capacitor 230V 53-64 MFD T2134 C0111 Overload Protector 230V T2134 C0112 Relay Starting 230V T2134 C0113 Bolt for Bracket Capacitor C0114 Nut M8 UNI 5589 C0115 Gasket Intake-Valve T2134 C0116 Valve Plate cpl. T2134 C0117 Gasket Exhaust-Valve C0120 Washer flat d=8-24mm UNI 6593 C0126 Rubber Grommet C0134 Cable Electric 230V 500mm C0147 Rubber Foot C0148 Plug for Frame C0149XX Frame / Chassis Tubular C0154 Washer Alum. D=6mm, 2x10mm C0171 Kit for Grounding C0180 Power Cord 115V Am.-Plug 2000mm C0202 Valve Head-Pressure Release C0214 Kit Terminal Bloc E88 230V C0215 Kit Terminal Bloc E88 115V C0216 Overload Protector 115V E88 C0218XX Pump Compressor 115V E88

Parts List PANTHER TC-Models C0222XX Pump Compressor 230V T2134 C0246 Overload Protector 230V C0250 Pump Compressor 115V E59 C0302 Head Cover with Cooling Ribs C0303 O-Ring 4675 C0304 Nut M6 Special C0305 Kit Terminal-Bloc T2134 230V C0306 Kit for Spring-Clamp C0308 Kit Motor-Parts cpl. T2134 230V w/o Housing C0309 Bolt for Cover C0310 Pressure-Pipe C0311 Gasket Pressure-Pipe C0312 Bolt for Top-Bearing C0313 Bearing Top C0314 Spring for Suspension C0315 Cover C0316 Gasket for Cover C0317 Overload Protector 115V T2134 C0319 Bolt for Cylinder-Head C0320 Bolt to mount Stator T2134 C0321 Stator 230V T2134 C0322 Kit Motor-Parts cpl. 230V T2134 without Housing C0323 Valve Intake T2134 C0324 Valve Exhaust T2134 C0325 Relay Starting 115V T2134 C0329 Fitting M-M-F-F1/4 cross C0331 Kit Motor-Parts cpl. 115V T2134 without Housing C0332 Stator 115V T2134 C0333 Kit Terminal Bloc 115V T2134 C0334 Fitting L M1/8 -F1/8

Parts List PANTHER TC-Models C0335 Hose Air F1/8 -F1/8 140mm C0338 Capacitor 115V T2134 C0339 Tube Nylon 8/6mm C0340 Switch Press. 4-P 115V MDR 21-EA/11 UL-Approved C0346 Fitting Reduction F1/4 -M1/8 C0349 Spring for Overload C0351 Valve Check M1/4 -M1/8 C0352 Fitting T M-F-F1/8 C0353 Valve Inline M1/4 -F1/4 C0354 Drain-Cock tanktop C0356 Tube Plastic 6/4mm blue C0358 Oil-Level Indicator ½ Metal Frame C0364 Bolt and Nut for Closing Band C0365 Kit Terminal Bloc E59 230V C0373 Relay Starting 115V E59 C0374 Overload Protector 115V E59 C0375 Kit Terminal Bloc 115V E59 C0392 Plug M1/8 C0416 Cable Electric 115V 600mm C0458XX Pump Compressor 115V T2134 A+AL C0481XX Head Cover with Cooling Ribs C0509 Fitting L M1/4 -F1/4 C0523 Kit Plug 1 C1109XX Tank 3,5lt. d=130mm C1205 O-Ring 4700 C1235 Kit Valve Plate T2134 cpl. with Gaskets C1236 Kit Valve Plate E88 cpl. with Gaskets C1237 Kit Valve Plate E59 cpl. with Gaskets C1393 Valve Safety M1/4 10 Bar C1478 Filter Regulator EAW 111 R0153 Bolt M8x25mm UNI 5739

EXPLODED VIEW