INSPIRE TM C The integrated closed system oxygenator for gentle perfusion

Similar documents
INSPIRE Min.I. Redefining minimally invasive approach to perfusion. Expand your choices with INSPIRE Min.I.

INSPIRE Oxygenator Family

INSPIRE TM Inspired choice

INSPIRE TM8 PH.I.S.I.O.

INSPIRE 6 PH.I.S.I.O.

A complete family of Pediatric Perfusion Systems

Adult All Integrated Mini Bypass System

1.060 Set-Up and Priming of the Bypass Circuit. Perfusion Technology Department. Perfusionists

Optimized Perfusion Management and Patient Outcome

CAPIOX FX Advance. Oxygenator with Integrated Arterial Filter and Hardshell Reservoir

S5 TM. Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

Patients come in a range of sizes. Now your oxygenator does, too.

Min.I. Mini Maxi Me. The proven safe and reliable, world-leading perfusion system, now optimized for minimally invasive and pediatric surgery

QUADROX-i Neonatal & Pediatric Maximum safety for the smallest patients.

Prescriptive Oxygenation

OxygenatOrs QUaDrOx-i adult QUaDrOx-i small adult

Considerations in Circuit Miniaturization

Clinical Engineering. Equipment (Heart-lung machines)

Emboli Production in Hardshell Venous Reservoirs at Low Reservoir Levels Devin Eilers, BS, Willie Glaze, BS, & David Holt, MA, CCT Clinical Perfusion

CDI Blood Parameter Monitoring System 500 A New Tool for the Clinical Perfusionist

An In-Vitro Study Comparing the GME Handling of Two Contemporary Oxygenators

CAPIOX SX Family of Oxygenators

CAPIOX SX Family of Oxygenators

CAPIOX SX Family of Oxygenators

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

Citation for published version (APA): Somer, F. M. J. J. D. (2003). Strategies for optimisation of paediatric cardiopulmonary bypass s.n.

Heart/Lung Perfusion Packs INSTRUCTIONS FOR USE

Blood Parameter Monitoring System 550

ila ACTIVVE SYSTEM PLATFORM

(12) United States Patent (10) Patent No.: US 6,524,267 B1

Innovative cap to reduce the noise raised by bubbling activity drainage working (vent close)

Limitations Using the Vacuum-Assist Venous Drainage Technique During Cardiopulmonary Bypass Procedures

Making Life Easier Easypump II

Point-of-Care Testing: A Cardiovascular Perfusionist s Perspective

InFlow Modular perfusion bioreactor

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Recommendations for Standards. Monitoring. Cardiopulmonary Bypass

Application of Micropore Filter Technology: Exploring the Blood Flow Path in Arterial-Line Filters and Its Effect on Bubble Trapping Functions

Inspire rpap REVOLUTION FROM THE FIRST BREATH

Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters

CDI System 500. Blood Parameter Monitoring System. Continuous blood parameter monitoring for improved blood gas management

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Equipment and monitoring for cardiopulmonary bypass

Errors in Flow and Pressure Related to the Arterial Filter Purge Line

Lung Volumes and Capacities

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

Contacts. Quick Start Guide

Keep the balance in sight

Thoracic Key Fastest Thoracic Insight Engine

FAST EVAPORATION AT NORMAL PRESSURE

An In Vitro Study of the Effectiveness of Carbon Dioxide Flushing of Arterial Line Filters

ENT 318/3 Artificial Organ. Artificial Lung. Lecturer Ahmad Nasrul bin Norali

Recirculating Coolers

tel: fax: web:

Alfred ECMO Circuit Priming and Storage Guide

PERFUSION SYSTEMS MECC SMART SMART SUCTION SYSTEM

Unity Sleeveless Elevated Vacuum System

Kieron C. Potger, CCP, BSc, Dip Perf, MClinN; Darryl McMillan, CCP, Dip Perf; Mark Ambrose, CCP, BNurs, Dip Perf

Used with Dissolution Tester for Fraction and Flow Measurements

Portable Oxygen Concentrator. Introduction

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

UT 3000 Mercury Ultratracer

GROUTEC SCOTT VICKERS. Grouting Equipment

Collin County Community College. Lung Physiology

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

swimming pool technology

Introduction. Respiration. Chapter 10. Objectives. Objectives. The Respiratory System

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

PART EIGHT HIGH FREQUENCY PERCUSSIVE OSCILLATION (HFPOV )

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

INTERNATIONAL MARKETING. 61, avenue Tony Garnier Lyon France Tel.: 33 (0) Fax: 33 (0)

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes

Tensiometer For the measurement of surface and interfacial tension

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Limb Perfusion Device

Sizes Weight Gripping force Stroke per finger Workpiece weight Pieces : kg N mm kg

APUS Anesthesia Machines

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

Tensiometer For the measurement of surface and interfacial tension

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

MEDAP-MOBILE GAS SUPPLY

Bloodlines, Tubing Systems, Accessories

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

The next generation of Blood and Fluid Warming

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

GENETIC INFLUENCE ON FACTORS OF OXYGEN TRANSPORT

Screw Compressors 11-22kW

Bunnell LifePulse HFV Quick Reference Guide # Bunnell Incorporated

Effect of Normobaric versus Hypobaric Oxygenation on Gaseous Microemboli Removal in a Diffusion Membrane Oxygenator: An In Vitro Comparison

Kieron C. Potger, CCP, BSc, Dip Perf, MClinN ; Darryl McMillan, CCP, Dip Perf ; Mark Ambrose, CCP, BNurs, Dip Perf

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

αo 2 : solubility coefficient of O 2

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Alaris Pump module FAQs

The next generation of Blood and Fluid Warming

Transcription:

INSPIRE TM C The integrated closed system oxygenator for gentle perfusion Expand your choices with INSPIRE C

Optimized air management Precise volume control Integrated and versatile system High biocompatibility 2

GENTLE PERFUSION INSPIRE C is a unique, integrated closed system oxygenator. INSPIRE C helps reduce gaseous micro-emboli (GME). INSPIRE C allows a low hemodilution cardiopulmonary bypass (CPB). INSPIRE C is available in both 6 LPM and 8 LPM sizes with or without integrated arterial filter. INSPIRE C, gentle on blood for a highly physiological perfusion. 3

Precise volume control The unique, transparent parallel plate squeezer and its fine adjustment mechanism allow precise maximum volume control. The INSPIRE C parallel plate squeezer provides a precisely designed environment where the collapsible venous reservoir predictably expands and behaves in respect to volume and air management. Continuous volume scale measurement Unique fine adjustment parallel plate squeezer Blood outlet design Flow-volume handling feature UNIQUE FINE ADJUSTMENT PARALLEL PLATE SQUEEZER CONTINUOUS VOLUME SCALE MEASUREMENT The volume scale measurement provides continuous volume indications. The regulation mechanism allows fine volume adjustment from 35 to 2 ml. The volume in the reservoir may change according to hydrostatic load and temperature. The precisely shaped squeezer of INSPIRE C provides gentle, continuous and uniform volume adjustment. Precise volume control and management is important during the perfusion procedure, especially during the weaning phase when small volume changes need to be correlated to changes in the hemodynamic status of the patient. BLOOD OUTLET DESIGN FLOW-VOLUME HANDLING FEATURE The molded outlet collector and carved outlet area comfortably allow high-flow, low volume operation. Collapsing is safe and predictable, and flow is gently restored, especially when using a centrifugal pump. This includes an area for convenient clamping of the venous flow and the removal of venous collector for residual blood recovery at the end of the procedure. By fully or partly clamping the venous manifold in the designated area, venous blood can be deviated to the cardiotomy reservoir, or its flow can be regulated when the cardiotomy line is clamped. 4

Optimized air management INSPIRE C is designed to optimize macro air removal and gaseous micro-emboli (GME) control through a combination of fluid-dynamics and filtration capabilities. The combined action of the overall geometry and the purge sites efficiently handle air in all working conditions, with or without squeezer. Top and Deep-purge dual air evacuation system Easy to de-bubble EFFICIENT GME CONTROL The INSPIRE C is designed to maximize GME control through a combination of fluid-dynamics (CFD) and filtration capabilities. The INSPIRE C helps reduce gaseous microemboli (GME), commonly indicated as a potential cause of neurological damage. TOP AND DEEP-PURGE DUAL AIR EVACUATION SYSTEM The top-purge efficiently handles air in most working conditions, while the deep-purge efficiently removes air when the squeezer is not in place or the reservoir is partly empty. GME COMPARISON EASY TO DE-BUBBLE Thoroughly designed geometry handles air extremely well for both macro air and micro bubbles. The combined action of the carefully designed body shape and venous inlet, the carved backplate and squeezer, and the single layer filter screen with top bypass efficiently handle air in all flow-volume conditions. TEST CONDITIONS (Gampt BCC2 bubble counter, Bovine blood, Ht=27%±2, Temp.= 3 C ±, Min squeezer volume indication, ml/min continuous air injection into venous line, 3 min data acquisition, Oxygenator purge lines closed, Venous reservoir purge lines open, purge flow 5 ml/min). INSPIRE 6F C v. Small Adult Closed System Oxygenators Post oxygenator average bubble count @ 4LPM blood flow 7. INSPIRE 8F C v. Adult Closed System Oxygenators Post oxygenator average bubble count @ 6LPM blood flow 7. 6. 6. 5. 5. Count/min 4. 3. 25-5 µm 5-25 µm -5 µm Count/min 4. 3. 2. 6- µm 2. 4-6 µm. 2-4 µm. Inspire 6F C Main competitor Main competitor 2-2 µm Inspire 8F C Synthesis C Main competitor Main competitor 2 5

High biocompatibility The PH.I.S.I.O PC coating and DEHP-free plastic materials increase biocompatibility, making INSPIRE C an advanced tool for closed system CPB. These features combine well with the limited surfaces in contact with blood, the intrinsic absence of defoaming agents and the minimal air-to-blood contact. OR OR' DEHP OUTER SURFACE PROTEIN PHOSPHORYLCHOLINE (PC) C6H4[COCH2CH(C2H5)(CH2)3CH3]2 CARBOHYDRATE DEHP-free materials INNER SURFACE PHOSPHORYLSERINE (PS) PHOSPHOLIPID BILAYER PH.I.S.I.O PC coating PH.I.S.I.O PC COATING PH.I.S.I.O PC coating has proven to be extremely effective in reducing platelet activation and white blood cell adhesion to foreign surfaces. Activated suction blood sequestration, combined with PH.I.S.I.O PC coating, offers maximum biocompatible benefits. DEHP-FREE MATERIALS The plastic materials of INSPIRE C are DEHP plasticizer-free and meet the latest recommendations in certain countries and institutions. DEHP plasticizers are known for their effects in pediatric and neonatal patients. REDUCED SURFACE AREA, NO DEFOAMING AGENTS AND MINIMAL AIR-TO-BLOOD INTERFACE INSPIRE C reduces foreign surfaces contact with blood, features NO defoaming agents and provides a CPB with MINIMAL air interface. This reduces the interaction of blood with the CPB environment. No defoaming agents Minimal blood/air contact 6

Integrated and versatile system The INSPIRE C is a truly easy and versatile integrated closed reservoir/oxygenator system. It's the most vertically compact oxygenator system on the market and allows a wide choice of set-up options on the heart-lung machine. INSPIRE C may be used either with or without squeezer according to the CPB technique in use. INSPIRE BKT and INSPIRE BKT FAST INSPIRE BKT COMBO INSPIRE BKT 2 INSPIRE BKT 2S ) SET-UP WITHOUT SQUEEZER Allows free blood volume handling Improves ease of use 2) SET-UP WITH SQUEEZER Allows full blood volume control Maximizes prime recovery prior CPB Precisely manages weaning from CPB Integrated device Separate devices Stand alone SVR Integrated device Separate devices Stand alone SVR 7

Minimized impact on hemodilution Introducing a whole new concept to closed system perfusion in CPB, from oxygenator module to oxygenator system. The INSPIRE C oxygenator system minimizes the impact on hemodilution at a system level by featuring low priming oxygenator modules, the lowest minimum operating level in the closed system reservoir (265 ml) and low venous collector priming volume. These elements determine the oxygenator system DOV in a closed circuit, impacting hemodilution. DYNAMIC OPERATING VOLUME (DOV) Venous collector priming volume Venous filter hold-up volume* From oxygenator module to oxygenator system Minimum operating level Oxygenator module priming volume OXYGENATOR SYSTEM DOV (at maximum blood flow) TEST CONDITIONS (Bovine blood, Hb 2±.2 gr/dl, Temp. 37± C, Min. Operating volume as per IFU or minimum squeezer volume, 6 cm hydrostatic load on Inspire SVR 2) INSPIRE 6F C v. Small Adult Closed System Oxygenators INSPIRE 8F C v. Adult Closed System Oxygenators ml. 9 8 7 6 5 4 6 LPM 5 LPM 8 LPM 7 LPM 937. 32 842 9 2 793 8 33 677 7 637 57 33 2 4 2 6 6 5 265 5 265 5 4 ml 977 32 6 3 3 2 284 44 295 2 35 43 26 335 Inspire 6F C Main competitor Main competitor 2 Inspire 8F C Synthesis C Main competitor Main competitor 2 Venous blood collector volume Mini operating volume Venous filter hold-up volume Oxygenator priming volume *Venous filter hold-up volume in closed circuit oxygenator systems is equivalent to ml. 8

Adult patient population and oxygenator of choice Patient Body Weight & Distribution per INSPIRE Market Assessment Study (MAS) database 5% < 8 Kg Yesterday's choice SMALL ADULT 4% Kg % > Kg 5 LPM 6 LPM FULL ADULT LivaNova's vision INSPIRE 6 LPM SMALL ADULT 6 Today's choice with INSPIRE OPTIMIZED ADULT From 5 to 6 LPM max blood flow rate 8 FULL ADULT Our Inspire 6 LPM oxygenator systems are the only optimized adult oxygenator systems with a low blood contact surface area which can minimize impact on hemodilution and effectively control GME, while offering full performance up to 6 LPM maximum blood flow. This oxygenator module covers the requirements of a wide patient population. INSPIRE 8 LPM This Inspire 8 LPM oxygenator systems provide superior performance up to 8 LPM, allowing clinicians to safely and comfortably treat all adult patients, while reducing hemodilution and effectively controlling gaseous micro-emboli (GME). INSPIRE 8 LPM oxygenator systems offer the ideal solution for powerful perfusion and have been designed to help clinicians standardize perfusion practice at the highest performance levels. INSPIRE TM the most complete family of adult oxygenator systems. BIOCOMPATIBILITY OPEN CIRCUIT RESERVOIR Single Chamber Dual Chamber Collapsible HVR SINGLE HVR DUAL CLOSED CIRCUIT RESERVOIR SVR 2 FLOW OXY MODULES 6 LPM w/o filter INSPIRE TM 6 INSPIRE TM 6 DUAL INSPIRE TM 6 C 6 LPM with filter INSPIRE TM 6F INSPIRE TM 6F DUAL INSPIRE TM 6F C 8 LPM w/o filter INSPIRE TM 8 INSPIRE TM 8 DUAL INSPIRE TM 8 C 8 LPM with filter INSPIRE TM 8F INSPIRE TM 8F DUAL INSPIRE TM 8F C 9

Performance charts INSPIRE 6 C INSPIRE 8 C INSPIRE 6F C INSPIRE 8F C TEST CONDITIONS Bovine blood - Hb 2±.2 gr/dl - B.E. ±2mEq/l - Venous pco2 45±5 mmhg - O2 Venous Sat. 65±5% - Blood Temp. 37± C - QG/QB= - FiO2 % - Qw=±,5 l/min TEST CONDITIONS Bovine blood - Hb 2±.2 gr/dl - B.E. ±2mEq/l - Venous pco2 45±5 mmhg - O2 Venous Sat. 65±5% - Blood Temp. 37± C - QG/QB= - FiO2 % - Qw=±,5 l/min TEST CONDITIONS Bovine blood - Hb 2±.2 gr/dl - B.E. ±2mEq/l - Venous pco2 45±5 mmhg - O2 Venous Sat. 65±5% - Blood Temp. 37± C - QG/QB= - FiO2 % - Qw=±,5 l/min TEST CONDITIONS Bovine blood - Hb 2±.2 gr/dl - B.E. ±2mEq/l - Venous pco2 45±5 mmhg - O2 Venous Sat. 65±5% - Blood Temp. 37± C - QG/QB= - FiO2 % - Qw=±,5 l/min O 2 (ml/min) INSPIRE 6 M Total O2 Transfer (ml/min) 4 35 3 25 2 5 5 2 3 4 5 6 7 O 2 (ml/min) INSPIRE 8 M Total O2 Transfer (ml/min) 5 45 4 35 3 25 2 5 5 2 3 4 5 6 7 8 9 O 2 (ml/min) INSPIRE 6F M Total O2 Transfer (ml/min) 4 35 3 25 2 5 5 2 3 4 5 6 7 O 2 (ml/min) INSPIRE 8F M Total O2 Transfer (ml/min) 5 45 4 35 3 25 2 5 5 2 3 4 5 6 7 8 9 CO 2 (ml/min) INSPIRE 6 M Total CO2 Transfer (ml/min) 35 3 25 2 5 5 2 3 4 5 6 7 CO 2 (ml/min) INSPIRE 8 M Total CO2 Transfer (ml/min) 45 4 35 3 25 2 5 5 2 3 4 5 6 7 8 9 CO 2 (ml/min) INSPIRE 6F M Total CO2 Transfer (ml/min) 35 3 25 2 5 5 2 3 4 5 6 7 CO 2 (ml/min) INSPIRE 8F M Total CO2 Transfer (ml/min) 45 4 35 3 25 2 5 5 2 3 4 5 6 7 8 9 Performance Factor (n) INSPIRE 6 M Heat Exchange Efficiency,,8,6,4,2, 2 3 4 5 6 7 Performance Factor (n) INSPIRE 8 M Heat Exchange Efficiency,,8,6,4,2, 2 3 4 5 6 7 8 9 Performance Factor (n) INSPIRE 6F M Heat Exchange Efficiency,,8,6,4,2, 2 3 4 5 6 7 Performance Factor (n) INSPIRE 8F M Heat Exchange Efficiency,,8,6,4,2, 2 3 4 5 6 7 8 9 3 INSPIRE 6 M Blood Path p (mmhg) 35 INSPIRE 8 M Blood Path p (mmhg) 3 INSPIRE 6F M Blood Path p (mmhg) 35 INSPIRE 8F M Blood Path p (mmhg) p (mmhg) 25 2 5 5 p (mmhg) 3 25 2 5 5 p (mmhg) 25 2 5 5 p (mmhg) 3 25 2 5 5 2 3 4 5 6 7 2 3 4 5 6 7 8 9 2 3 4 5 6 7 2 3 4 5 6 7 8 9 Technical specifications OXYGENATOR SYSTEM INSPIRE 6 C INSPIRE 8 C INSPIRE 6F C INSPIRE 8F C Oxygenator System D.O.V. @ max flow 47 ml 55 ml 57 ml 637 ml Biocompatible Coating Phosphorylcholine (PHISIO) Phosphorylcholine (PHISIO) Phosphorylcholine (PHISIO) Phosphorylcholine (PHISIO) RESERVOIR Max. Volume Capacity (approx. value) 325 ml 325 ml 325 ml 325 ml Min. Operating Volume (approx. value) 265 ml 265 ml 265 ml 265 ml Venous Filter micron size 5 µm polyester screen 5 µm polyester screen 5 µm polyester screen 5 µm polyester screen OXYGENATOR MODULE Maximum Blood Flow Rate 6 l/min 8 l/min 6 l/min 8 l/min Static Priming Volume (oxy module + heat exchanger average value) 84 ml 29 ml 284 ml 35 ml Membrane surface area (approx. value),4 m²,75 m²,4 m²,75 m² Heat Exchanger material Polyurethane Polyurethane Polyurethane Polyurethane Heat Exchanger surface area (approx. value),4 m²,4 m²,4 m²,4 m² Arterial Filter material type Polyester net Polyester net Arterial Filter micron size 38 µm 38 µm Arterial Filter surface area 68 cm² 97 cm²

Order guide ITEM # DEVICE DESCRIPTION UNITS PER CASE IMAGE Available only into PTS INSPIRE 6 C INSPIRE 6 LPM PHISIO OXY MODULE WITH INTEGRATED PHISIO 2 SOFT SHELL VENOUS RESERVOIR N.A. 572 INSPIRE 6F C INSPIRE 6 LPM PHISIO OXY MODULE WITH INTEGRATED ARTERIAL FILTER AND PHISIO 2 SOFT SHELL VENOUS RESERVOIR Available only into PTS INSPIRE 8 C INSPIRE 8 LPM PHISIO OXY MODULE WITH INTEGRATED PHISIO 2 SOFT SHELL VENOUS RESERVOIR N.A. 5722 INSPIRE 8F C INSPIRE 8 LPM PHISIO OXY MODULE WITH INTEGRATED ARTERIAL FILTER AND PHISIO 2 SOFT SHELL VENOUS RESERVOIR 576 INSPIRE SVR 2 INSPIRE PHISIO 2 SOFT SHELL VENOUS RESERVOIR 564 INSPIRE BKT BRACKET FOR INSPIRE OXY MODULES AND INTEGRATED OXYGENATOR SYSTEMS 48-42- IINSPIRE BKT FAST* BRACKET FOR INSPIRE OXY MODULES AND INTEGRATED OXYGENATOR SYSTEMS WITH FAST CLAMP 5642 INSPIRE BKT COMBO BRACKET FOR COMBINED INSPIRE SVR SYSTEMS TO BE USED IN CONJUCTION WITH INSPIRE BKT 2 and 2S BRACKETS 5645 INSPIRE BKT 2 BRACKET FOR INSPIRE SVR 2 5646 INSPIRE BKT2 S SQUEEZER FOR INSPIRE SVR 2 TO BE USED IN CONJUCTION WITH INSPIRE BKT, INSPIRE BKT FAST, INSPIRE BKT 2 AND INSPIRE BKT COMBO BRACKET 42229 TEMPERATURE PROBES TEMPERATURE PROBES 2 *To be ordered as an accessory of LivaNova S5 and C5 HLMs.

HEARTLINK TM SYSTEM INSPIRE C is a key component of the LivaNova HeartLink TM System: the first automatically integrated Perfusion Management System designed for improved patient outcomes, increased clinical efficacy and Goal-Directed Perfusion. HEARTLINK TM CARD GDP TM MONITOR CONNECT TM INSPIRE TM C XTRA S5 TM 9/6 9295-88/A LivaNova s Green Leaf program EN ISO 3485:22/AC 22 Manufactured by: Sorin Group Italia Srl A wholly-owned subsidiary of LivaNova PLC Via Statale 2 Nord, 86 437 Mirandola (MO) Italy Tel. +39 535 298 - Fax +39 535 25229 info.cardiacsurgery@sorin.com Refer to the information for Use provided with each product for detailed information, warnings, precautions and possible adverse side effects. 26 LivaNova all rights reserved.