MV5: Automated concentration system

Similar documents
FAST EVAPORATION AT NORMAL PRESSURE

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Digital Vacuum Regulator

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Objective To identify a pure liquid substance using the physical properties of solubility, density, and boiling point.

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Customer Responsibilities

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

FROG-4000 TM Chemical Analysis System

Procedure of Xenon Transfer

Major Design Features

ProSys Laboratory Analytical Isolators

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Series Environmental Chambers

ARC Unofficial Manual to the Solvent Dispensing System. Designed by J. C. Meyer

Gas Diluter Portable Gas Dilution System User s Manual

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The instrument will process the samples one by one till all the samples have been cleaned up.

Demystifying the Process of Calibrating your Thermal Desorption Gas Chromatography System using Compressed Gas Standards.

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

OPERATION MANUAL NTF-15

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

Standard Operating Procedure Inert Vacuum Line. Ryan Mulvenna, May 2012

UsER manual for Watersens ph -REDOX

Simultaneous Determination of a Panel of 22 Steroids in Urine and Serum by SPE and LC-MS/MS

APPLICATION NOTE. GC Integrated Permeation Device

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

Project Title: Pneumatic Exercise Machine

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

HumiSys HF High Flow RH Generator

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Issue 1-6 October 2008

School of Chemistry SOP For Operation Of Glove Boxes

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

extraction of EG and DEG from the matrix. However, the addition of all diluent at once resulted in poor recoveries.

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Joint industry project on foam

Tradition & Technology

Columbus Instruments

OPERATION MANUAL NTF-60 Plus

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

7.9. Flash Column Chromatography Guide

Recirculating Coolers

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Equipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY

Reverse Osmosis System Installation Guide and Operation Manual.

Chem Bio Liquid Nitrogen Facility

Automated Low Background Solid Phase Extraction of Perfluorinated Compounds in Water. Ruud Addink Fluid Management Systems Watertown MA

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Inprocess Operator Training Programme

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

Air Quality 2b - PFGC/FID Analysis of Benzene and Toluene in Automobile Emissions

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Improvements in the Reliability, Costs and Processing of WLP/RDL Circuits

SOLVENT PURIFICATION SYSTEMS

Digital Vacuum Regulator

User guide for operating the Agilent 6420A QqQ mass spectrometer by direct infusion/injection

Manual for continuous distillation

Digital Vacuum Regulator

MB-SP Series Solvent Purification System

2B Technologies, Inc.

Digester Processes. 1. Raw Sludge Pumping System

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Operating Instructions

Research Teaching Production

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

Quick Start Guide for SA-9600 Series Surface Area Analyzer

The Cyclone Tire Deflation & Inflation Tool

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

COMPRESSED AIR DISTRIBUTION SYSTEMS

GCMSD-Headspace Analysis SOP

TEST SPECIFICATION NYT-909-C

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

THERMODYNAMICS OF A GAS PHASE REACTION: DISSOCIATION OF N 2 O 4

STANDARD OPERATING PROCEDURES

FROG-4000 TM Chemical Analysis System

Setting a New Standard in Flash Chromatography Performance

KRONES filling systems for beer Filling of glass containers and cans

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

The latest automotive systems require innovative leak test methods and fixturing.

krones Sensometic VP and VPL The intelligent probe filler systems

Parallel Reactor Standard Operating Procedure THIS SOP IS NOT MEANT TO REPLACE HANDS-ON TRAINING FROM QUALIFIED PERSONNEL!

System Overview. TCD Detector temperature setpoint Regulator

Geotech 1.66 Reclaimer Installation and Operation Manual

MASS TRANSFER LAB. Make & Model. S. No. Equipment

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

How to use Solvent Purification System A brief manual

Navigator 600 Silica analyzers

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller

Transcription:

MV5: Automated concentration system Abstract LabTech MV5 is the latest automatic nitrogen evaporator developed by our R&D Team able to process up to 54 samples simultaneously. This advanced instrument allows automatic control of both the nitrogen flow rate and the vertical lift of nitrogen needles. These unique features can greatly speed-up the vapour removal and maximize the solution surface area in contact with nitrogen gas, thus significantly saving nitrogen gas consumption and improving evaporation efficiency. Meanwhile, MV5 water bath temperature and N 2 gas flow rate can be adjusted during the evaporation process depending on solvent boiling point and volatility. The experimental results presented in this article show that MV5 is able to simultaneously evaporate most of the extraction solvents in optimal experimental conditions, making it a unique solution for all analytical laboratories. Introduction Solvent evaporation, as an essential step of sample preparation before chromatographic analysis, is commonly used in a broad range of fields, such as pharmaceutical, environmental, petrochemical and other industrial analytical laboratories. The primary purpose of evaporation is to increase the analytes concentration (especially in the range of ppb (µg/l) or below) to improve their detection limit before analysis. Nitrogen stream, rotary vacuum and centrifugal evaporator are the most commonly used techniques in analytical laboratories to evaporate samples. Generally major factors affecting the concentration rate are the heating temperature, the vapour removal and the solvent surface area. 1

Nitrogen stream evaporation is a very common and mature technique, typically used to evaporate solvents by heating stable analytes and using a stream of nitrogen gas which is directly blown in the solution. The critical point using nitrogen stream evaporation is the setting of liquid bath temperature to grant the highest evaporation speed without the risk of analytes evaporation or degradation. Rotary vacuum is an evaporation technique where samples are placed into a round-bottom rotating flask immersed in an heated liquid bath. A vacuum pump is connected to reduce the pressure inside the flask and vacuum is applied to reduce the boiling point of solvents. Main disadvantage of rotary evaporator is the limited number of sample evaporating simultaneously. Centrifugal evaporation systems typically involve a heated centrifuge with a vacuum pump to concentrate the samples; heating and vacuum functions facilitate the solvent evaporation at lower temperature respect the standard boiling point under atmosphere pressure. Main disadvantages of this technique are the temperature stability, the cross contamination and the inability to monitor the sample concentration during the process. LabTech MV5 Overview MV5 is the perfect choice to complete organic sample preparation process after SPE with LabTech Sepaths-UP and Sepline-S systems. MV5 can concentrate up to 54 samples simultaneously from 1,5 ml to 200 ml volume. Sample tube size can be customized according customer requests and nitrogen needle positions can be adjusted automatically or manually according to sample volume reduction during the evaporation process. This unique feature of MV5 reduces the evaporation time and nitrogen gas consumption compared to traditional nitrogen stream evaporators. Once the distance between nitrogen blowing needle and solvent surface is optimized, the vortex solution flow in the sample tube increases the surface area in contact with nitrogen and speed up the evaporation rate. 2

Test tube Nitrogen blowing needles (6 channels and removable) Water bath Front window to monitor concentration process 7 Touch screen color control panel Figure 1. MV5 evaporator Nitrogen blowing needle Sample test tube Vortex solution flow Figure 2. Vortex solution with nitrogen blowing needles Water drain valve Needles manual level controller Water drain tube Figure 3. MV5 evaporator side view 3

To increase safety and facilitate routine maintenance, the liquid inside the bath can be easily removed by the drain valve on the lateral side of the unit (see fig.3). MV5 is specifically designed as a fume hood free system. The exhaust hose on the backside of the instrument can be directly connected to any air vent system or fume hood to remove solvent vapours and grant user s safety (see fig. 4). N 2 inlet Power Exhaust hose connection Figure 4. MV5 evaporator back view 4

Experimental section A series of experiments were conducted with pure solvents to test the evaporation efficiency of MV5 among different sample tubes. N 30 test tubes for each solvents were placed to represent the whole sample tube rack area (26 around the perimeter and 4 in the middle section). 5 ml volume of six commonly used extraction solvents (methanol, dichloromethane, ethyl acetate, cyclohexane, hexane and acetonitrile), 0,5 mm/min nitrogen needle descend speed, nitrogen gas pressure from 2 psi up to 12 psi and different liquid bath temperatures were set to study the main important factors affecting evaporation efficiency. Table 1. Experimental evaporation results Solvent Initial volume (ml) H 2 O Bath temp N 2 pressure (psi) Solution final volume Evaporation time for final volume (min) Time to dryness (min) ( o C) (ml) MeOH 5 44 10 1.1±0.3 25 28 56 10 13 DCM 5 40 3 12 7 11 12 0.8±0.3 10 11 5 35 12 1.0±0.3 10 13 EtAC: Cy (1:1) EtAC: HEX (1:1) 5 76 12 0.8±0.4 6 9 5 65 12 0.9±0.4 6 9 55 12 24 ACN 5 65 3 18 7 16 12 0.8±0.4 11 14 75 12 12 ---MeOH: methanol DCM: dichloromethane EtAC: ethyl acetate Cy: cyclohexane HEX: hexane ACN: acetonitrile 5

Looking at the results in table 1, it is evident that solvents were evaporated completely within 15 min (for 9 test conditions out of 13). N 4 tests requiring more than 15 min of evaporation time (methanol with liquid bath at 44 o C, acetonitrile at 55 o C, and acetonitrile at 65 o C with N 2 pressure set both at 3 and 7 psi) show that liquid bath temperature and N 2 gas pressure have great impact on the evaporation rate. Considering boiling points of methanol and acetonitrile (65 o C and 82 o C respectively), liquid bath temperatures set in MV5 (44 o C and 55 o C respectively) are certainly too low for these two solvents, which manifest their slow evaporation rates under these conditions. Once the water bath temperatures were raised close to the solvent boiling points, the evaporation rates were dramatically increased. Fig. 5 shows the ACN behavior: at increasing water bath temperature by 20 C (from 55 o C to 75 o C), evaporation time decreases dramatically from 24 min to 12 min. Therefore, if the analytes are thermally stable, water bath temperature should be set as close as possible to the solvent boiling point to maximize the evaporation rate. Figure 5. Evaporation time of ACN as function of N 2 gas pressure and water bath temperature The effect of nitrogen gas pressure on evaporation efficiency was further analyzed. Three different N 2 pressure (3, 7 and 12 psi) were applied at both dichloromethane (water bath temperature 40 o C) and acetonitrile (water bath temp 65 o C) systems. For a volatile solvent such as dichloromethane (boiling point 40 o C), gas pressure appears not to greatly affect the 6

evaporation rate, suggesting that water bath temperature is a dominant factor. Therefore, in the lab evaporation practice with volatile solvents, lower N 2 gas flow rate can still enable fast evaporation, with the positive effect of keeping low nitrogen gas consumption. By contrast, for less volatile solvents, as acetonitrile, which has relatively high boiling point (82 o C), higher N 2 gas pressure leads to higher evaporate rate, as shown in fig. 5. Final sample volumes, also listed in table 1, were measured to be ~1 ml for 6 test conditions, indicating that MV5 is able of simultaneously evaporate sample solutions in different positions thanks to the particular design of nitrogen blowing needles (the small diameter of N 2 blowing needle allows N 2 gas to flow equally in all 6 different channels). Conclusions MV5 automated evaporation system can significantly speed up the workflow and reduce the labor time during evaporation. All the features of MV5, such as programmable method setup and automated vertical lift of nitrogen needles, promote the evaporation performance and reduce N 2 gas consumption. Preliminary studies demonstrate both water bath temperature and N 2 flow rate improve evaporation efficiency for different solvents. In the laboratory practice, water bath temperature should be appropriately set close to the solvent boiling points, not underestimating the risk of losing analytes in order to obtain good sample recovery. 7