Thermocirc Installation and Maintenance Instructions

Similar documents
FT16 Ball Float Steam Trap Installation and Maintenance Instructions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

SCA Series Inverted Bucket Steam Traps

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

DF1 and DF2 Diffusers

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

TSS21 Sealed Thermostatic Steam Tracer Trap

AVC32 Carbon Steel Air Vent for Steam Systems

AVM7 Stainless Steel Thermostatic Air Vent

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

PV4 and PV6 Piston Valves

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

CA44, CA44S, CA46 and CA46S Air and Gas Traps

Airodyn, BRair and BRoil Compressed Air Drain Traps

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

BPT13 Balanced Pressure Thermostatic Steam Traps

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

S and SF Inverted Bucket Steam Traps

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

CA10S, CA14 and CA14S Air and Gas Traps

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

DCV6 Disc Check Valve

CVS10 Sanitary Check Valves

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

CP10 Sensor Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

Dri-Line Mk3 Monnier Compressed Air Drain Trap

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

BDV1 and BDV2 Blowdown / Depressurisation Valves

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

TP1 and TP2 Temporary Cone Shaped Strainers

BCV31 DN40 - Blowdown Control Valve

FV Flash Vessel Installation and Maintenance Instructions

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

MFP14-PPU (Vented) Automatic Packaged Pump Units

PC10HP Pipeline Connector (ASME 600)

SRV66 Sanitary Pressure Reducing Valve

MF2M Monnier Miniature Compressed Air Filter

PC3_ and PC4_ Pipeline Connectors

SRV2S Pressure Reducing Valve

CS10-1 Stainless Steel Clean Steam Separator

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

TW Temperature Control Valve

APT14, APT14HC and APT14SHC Spares 2

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

Manual Actuated Boiler Blowdown Valves

BCV31 DN20 - Blowdown Control Valve

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

CA44 and CA44S Carbon Steel Air and Gas Traps Flanged DN15 to DN25

ML3M Monnier Miniature Compressed Air Lubricator

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

BCVi43 Blowdown Control Valve

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

BRV71 and BRV73 Pressure Reducing Valves

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

Blowdown vessels Meeting the requirements of HSE PM60

BSA and BSAT Bellows Sealed Stop Valves Installation and Maintenance Instructions

Spirax Compact FREME Flash Recovery Energy Management Equipment

QuickHeat TM Packaged Heat Exchanger Solutions

CA14 SG Iron Air and Gas Trap ½" and ¾" (Screwed)

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

DP17, DP17E, DP17G, DP17R, DP17Y and DP27G Pilot Operated Pressure Reducing Valves

Steam / Water Mixing Stations (MkII valves onwards) Safety and Operation Installation and Maintenance Instructions

595-K/L and 596-K/L Series Self Operated Valves Installation and Maintenance Instructions

LP10-4 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance IM-P402-92

Transcription:

1570072/2 IM-P157-36 ST Issue 2 Thermocirc Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operation 6 Maintenance 7 Spare parts Printed IM-P157-36 in the ST UK Issue 2 Copyright 20021

1 General safety information Safe operation of the unit can only be guaranteed if it is properly installed, commissioned and maintained by a qualified person (see Section 11 of the attached Supplementary Safety Information) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. Isolation Consider whether closing isolating valves will put any other part of the system or personnel at risk. Dangers might include; isolation of vents and protective devices or alarms. Ensure isolation valves are turned off in a gradual way to avoid system shocks. Pressure Before attempting any maintenance consider what is or may have been in the pipeline. Ensure that any pressure is isolated and safely vented to atmospheric pressure before attempting to maintain the product, this is easily achieved by fitting Spirax Sarco depressurisation valves type DV (see separate literature for details). Do not assume that the system is depressurised even when a pressure gauge indicates zero. Temperature Allow time for temperature to normalise after isolation to avoid the danger of burns and consider whether protective clothing (including safety glasses) is required. Disposal The product is recyclable. No ecological hazard is anticipated with the disposal of this product providing due care is taken. 2 IM-P157-36 ST Issue 2

2 General product information 2.1 Description The thermocirc utilises liquid expansion technology as a mixing valve. The fixed temperature, liquid expansion, oil filled element is factory set but does allow for minor adjustment. By combining the functions of temperature control and steam injection, the Thermocirc produces hot water by the direct mixing of steam and cold water. Note: For additional information see Technical Information Sheet TI-P157-19. 2.2 Sizes and pipe connections ½" screwed BSP or NPT. 2.3 Limiting conditions Body design conditions PN25 PMA - Maximum allowable pressure 25 bar g (363 psi g) TMA - Maximum allowable temperature 260 C (500 F) PMO - Maximum operating pressure 10.3 bar g (150 psi g) TMO - Maximum operating temperature 260 C (500 F) Temperature range 49 C to 82 C (120 F to 180 F) Designed for a maximum cold hydraulic test pressure of 38 bar g (551 psi g) 2.4 Operating range Temperature C 260 200 150 100 50 Steam saturation curve 0 0 5 10 15 20 25 10.3* Pressure bar g The product must not be used in this region. *PMO Maximum operating pressure recommended for saturated steam is 10.3 bar g (150 psi g). IM-P157-36 ST Issue 2 3

3 Installation Note: Before actioning any installation observe the 'Safety Information' in Section 1. Two typical installations are shown in Figures 1 and 2. For hot water tanks the most efficient operation is obtained by fitting the thermocirc vertically on the side of the tank (see Figure 1). The most rapid response will be obtained if the cold water make-up is discharged close to the recirculation circuit inlet of the thermocirc at the bottom of the tank. The hot water draw-off should be taken from as high up as is practicable. Note: A strainer and check valve should always be fitted in the steam inlet pipework prior to entry into the thermocirc as shown below. The pipeline strainer is fitted to protect the valve from scale, etc. The check valve prevents water draining from the tank or jacket when the steam is off. Caution: The thermocirc is not suitable for controlling at temperatures above 82 C (180 F). Hot water Tank Thermocirc Cold water Check valve Angle strainer Steam supply Fig. 1 Typical installation (Thermocirc fitted directly to a small hot water tank) Steam inlet Hot water jacketed process pan Overflow Thermocirc Strainer Check valve Fig. 2 Spirax Sarco Thermocirc applied to a water-jacketed vessel 4 IM-P157-36 ST Issue 2

4 Commisioning After installation or maintenance ensure that the system is fully functioning. Carry out tests on any alarms or protective devices. 5 Operation The Spirax Sarco thermocirc is a device for obtaining hot water at a higher temperature by the direct mixture of steam and cold water. Steam enters at point (C) and passes through the stainless steel nozzle (3) into the body (the mixing chamber) of the device. The velocity of steam through (3) induces a flow of cool water, from the storage tank or other vessel, into the mixing chamber via the cold water inlet (A). The steam condenses in the water and so warms it, the warm water passes back into the storage vessel. Inside the mixing chamber there is a liquid-filled thermostat (8) which is adjustable by turning the adjustment nut (13) so that it closes the stainless steel valve (2) against the steam inlet nozzle (3) when a predetermined temperature is reached in the mixing chamber. Once set, the, thermostat, without further attention will continue to operate the valve according to the required temperature. Adjustment is between 49 C and 82 C. 13 Hot water outlet B 8 2 3 Cold water inlet A Fig. 3 Steam inlet C IM-P157-36 ST Issue 2 5

6 Maintenance Note: Before actioning any maintenance programme observe the 'Safety Information' in Section 1. Adjustment: - Isolate the thermocirc from the supply, return and steam lines and allow the unit to safely normalise to atmospheric pressure. - The thermocirc should be allowed to cool to ambient temperature before proceeding. - The control is calibrated in the factory, but may require initial adjustments to match it to your conditions. - Loosen the lock-nut (14) 1 /12 of a turn anticlockwise. - Turn the adjustment nut (13) as indicated by the arrow - 'open', in order to increase the temperature. Turn the adjustment nut as indicated by the arrow - 'closed', in order to decrease the temperature. - Hold the adjustment nut (13) with one spanner and tighten the lock-nut (14) with another. Refer to Table 1 for the recommended tightening torques. Note: Adjustment nut (13) should not be moved more than ¼ turn at a time; wait for the effect of each adjustment on the temperature of the stored water before making further adjustments. Replacement of element: - Isolate the thermocirc from the supply, return and steam lines and allow the unit to safely normalise to atmospheric pressure. - The thermocirc should be allowed to cool to ambient temperature before proceeding. - Remove the lock-nuts (10 and 14) at both ends of the unit. - Remove the element (8) and spring (11) and unscrew the stainless steel valve seat ring (3). - Ensure all gasket contact areas are clean. - Reassemble the new valve seat ring (3) and new element (8) ensuring the spring (11) is correctly located. - Replace the lock-nuts/adjustment nuts (10 and 14) and tighten to the recommended torque (see Table 1). Table 1 Recommend tightening torques Item Part or N m (lbf ft) 3 Valve seat ring 30-35 (22-26) 10 Lock-nut 1 15 / 32" A/F 80-85 (59-63) 14 Lock-nut 1 15 / 32" A/F 80-85 (59-63) 6 IM-P157-36 ST Issue 2

13 11 14 Hot water outlet 8 3 Cold water inlet 10 Fig. 4 Steam inlet IM-P157-36 ST Issue 2 7

7 Spare parts The spare parts available are shown in heavy outline. Parts drawn in broken line are not supplied as spares. Available spare Element set 3, 4, 5, 6, 8, 11, 12 How to order spares Always order spares by using the description given in the column headed 'Available spare' and state the size and type of control. Example: 1 - Element set for a ½" Spirax Sarco thermocirc. 11 8, 12 3, 4, 5, 6 Fig. 5 8 IM-P157-36 ST Issue 2