Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater

Similar documents
AirSep PSA Nitrogen Systems

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

Medical Oxygen Concentrator Systems. Generate gases on site generate savings

Breathing Air Purifiers. Comply with European Pharmacopoeia and International Breathing Air Standards

ON-SITE INDUSTRIAL GASES. Nitrogen & Oxygen Generators

Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

Niltox Breathing Air Purifier Range

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators


Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-60 Plus

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

Air Amplifiers & SYSTEMS

Breathing Air Purifiers Comply with European Pharmacopoeia and International Breathing Air Standards ENGINEERING YOUR SUCCESS.

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

Unique solutions for medical oxygen

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Breathable Compressed Air

/ /

Compressed Air - Food/Bev. Presented By: Adam Zimmerman

- Cost for regular gas filling. - Additinal costs, i.e. tank rent, delivery. - Cost for regular liquid nitrogen filling

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Trifecta High-Pressure Systems

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Mobile Breathing Air Systems

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Type 3 - PSA Nitrogen Generation System

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

RAM 4021-DPX Operation Manual

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

MEDICAL EQUIPMENT CATALOG

NGN Series nitrogen generator

TECHNICAL INFORMATION

Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Unique solutions for Oxygen and Nitrogen supply

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Balston Nitrogen Generation Systems

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Medical Oxygen Concentrator Systems. Generate gases on site generate savings

Workhorse-15 Oxygen Generator

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

OX SCFH Oxygen Concentrator. Installation and Operation Manual

Inert Air (N2) Systems Manual

Optimizing Gas Supply for Industrial Lasers

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

Nitrogen generation for modified atmospheric packaging

THE DELIVERY OF GAS SUPPLY

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

On site Nitrogen Generating system

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

Air Operated Hydraulic Pumping Systems to 50,000 psi

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

CompAir provide high quality and reliable Nitrogen solutions

Potter Nitrogen Generators

TECHNICAL SPECIFICATION. StirLIN-1 Extendible Liquid Nitrogen System

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Technical Information

RAM Operation Manual

Air Eliminators and Combination Air Eliminators Strainers

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Model OG-15 & OG-15 Compressorless Oxygen Generator Installation, Operation & Maintenance Manual

Your local gas generation partner. Precision series Modular gas generation solution for GC.

TECHNICAL INFORMATION

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

RAM 4021 Operation Manual

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

B-Series. breathing air systems flow capacity: scfm

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

Flow meter. bellow vaporizer. APL valve. Scavenging system

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

JORDAIR/BAUER Service Manual

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

MOGS 100 Installation, Operation and Maintenance Manual

OPERATING INSTRUCTIONS

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Operation Instruction Manual

nert Gas: Inert gas systems on ships

INSPECTION OF MEDICINAL GASES

Installation restrictions for length of sections should also be noted.

CO 2 and O 2 scrubbers

BACK PRESSURE / SUSTAINING

AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

Unit 24: Applications of Pneumatics and Hydraulics

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

NITROGEN GENERATOR Tradition Trail Plano, Texas 75093

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Squire-Cogswell

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

BACK PRESSURE / SUSTAINING

Transcription:

Oxygen Generating Systems General Information Extract oxygen directly from the atmosphere and deliver it to any medical or industrial application with an OGSI oxygen generator. Our standard line of Pressure Swing Adsorption generators can delivered a constant flow of up to 95% oxygen purity at 45-60 PSI. Higher oxygen purity and pressure is optionally available. Dependable Every PLC-controlled generator is assembled and tested in our North Tonawands, NY production facility. The zeolite sieve is factory sealed in solid steel tanks, and rarely needs replacement. With very few moving parts, our generators are built to provide thousands of hours of continuous, reliable service. Routine maintenance is as simple as changing an air filter. Durable From their precision-welded tank assemblies, to their oxygen-clean brass tubing and valves, our generators operate in the harsh environments of Africa, Asia, South America and the Yukon. Model OG-25 and OG-75 Oxygen Generators Economical Eliminate the unnecessary costs of transportation, storage and cylinder rental. Our standard product line has 18 models from 25 to 5,000 standard cubic feet / hour (0.66 to 131 Nm3/hour) you ll never pay for capacity you don t need. Non standard generators are available on request. Unfamiliar with PSA oxygen systems? Call, fax or email for a personalized quotation. OGSI can provide the proper air compressor, dryer and storage tank combination to optimize your oxygen system. We can assemble the system and test it in our factory before shipment. All components can be mounted to a metal skid and pre-wired for easy transportation and setup. Visit www.ogsi.com for further specifications, drawings, manuals and photos of our full line of oxygen generators. 1.800.661.9983 Model OG-1000 Undergoing factory inspection www.magtool.com www.magtool.com 1-800-661-9983

O2 Outputs Average Inlet Dimensions (inches) Standard Model (SCF/HR) (Nm 3 /Hr) Liters/Min (LPM) Air Required (CFM@90 psig) Width Depth Height Weight (LBS) Tank Size (Gallons) OG-25 25 0.7 12 6 16 13 51 190 60 OG-50 50 1.4 24 12 20 14 63 275 60 OG-75 75 2.1 35 17 22 21 69 310 60 OG-100 100 2.8 47 22 24 24 69 600 60 OG-175 175 5.0 83 32 26 25 72 775 80 OG-250 250 7.1 118 45 30 25 81 1,100 120 OG-375 375 10.6 177 68 36 30 84 1,350 120 OG-500 500 14.2 236 88 46 36 89 1,800 120 OG-650 650 18.4 307 118 55 44 84 3,600 200 OG-750 750 21.2 354 133 55 48 91 4,000 400 OG-1000 1,000 28.3 472 175 55 48 121 4,250 400 OG-1250 1,250 35.4 590 225 60 50 126 4,500 400 OG-1500 1,500 42.5 708 280 75 57 102 9,500 660 OG-2000 2,000 56.6 944 425 75 57 125 10,000 660 OG-2500 2,500 70.8 1,180 575 88 66 150 11,300 660 OG-3000 3,000 85.0 1,416 625 88 66 150 12,750 1060 OG-4000 4,000 113.3 1,888 800 95 77 169 14,750 1550 OG-5000 5,000 141.6 2,360 1000 95 77 169 16,750 1550 Specification Notes All pressure vessels are designed to meet ASME code (Section VIII, Div. 1) Cold cut without thermal alterations Easy execution of the cutting Execution of the cutting in a few seconds with one single rotation around the pipe Simultaneous pipe cutting and bevelling with special cutters Cutting speed regulation Typical System Configuration 7 Bar 100 PSIG 3 Bar 45 PSIG Oxygen Regulator Particulate Filter Coalescing Filter Oxygen Hose to Customer Application Air Compressor Air Dryer Refrigerated Air Surge Tank (AST) Oxygen Generator Oxygen Surge Tank (OST) * Also Available From OGSI [ OG-15 self-contained generator ] [ Cylinder Filling Plants ]

What is Pressure Swing Absorption (PSA) Technology? PSA is one of several technologies currently in use for separating oxygen from air. How does PSA work? PSA incorporates a material called molecular sieve for gas separation. This zeolite based sieve has a preferential adsorption for nitrogen. Clean dry air is passed through the sieve beds on the oxygen generator, producing an oxygen enriched gas. Does an oxygen generator have to be indoors? Standard OGSI oxygen generators are designed for use indoors. Does the equipment room have to be air conditioned? PSA oxygen generators provide the best performance in temperatures between 40 degrees F (4 degrees C) and 80 degrees F (27 degrees C). Does the equipment room require humidity control? PSA oxygen generators provide the best performance when the feed air has a dew point of 40 degrees F (4 degrees C) or less. Depending on the model selected and or the feed air equipment (air compressor, dryer, air surge tank and feed air filters) supplied, humidity control may or may not be required for the room. Consult factory for recommendations on a specific applications. Can the air preparation equipment be located in a separate area from the oxygen generator? The air preparation or feed air equipment can be located in a different room than the oxygen generator. What are the maintenance requirements of PSA oxygen generators? PSA oxygen generators have internal filters that have recommended element replacement about every 6 months under 24/7 operation. Additionally, valves will have to be rebuilt every few years. The majority of the maintenance will involve the service of the air compressor recommended by the air compressor manufacturer. How long does the molecular sieve last? The molecular sieve life is based on the feed air quality. If the feed air quality always meets recommended standards, the sieve can last indefinitely (20 years or more!) If the molecular sieve ever became contaminated by oil, dirt or water can it be cleaned or can it be replaced? If the molecular sieve is contaminated by oil it will have to be replaced. Water contamination, based on degree, does not necessary mean the sieve will to be replaced. Dirt is rare cause of sieve replacement, but other contaminates like ammonia can cause sieve failure. Consult factory for specific air contamination that may be present at the generator site. Can the oxygen generator be operated with contaminated sieve, and what are the consequences? A PSA oxygen generator may still operate after it has been contaminated, but a reduction in oxygen purity and flow should be expected. This may be critical in many applications, such as hospitals where the oxygen is being breathed. Is it easy to replace the molecular sieve and how much does it cost? All OGSI oxygen generators are designed so that the sieve can be changed in the field. The cost of the sieve change depends on the generator model and size. Is molecular sieve readily available, or is it hard to get in many localities? There are several suppliers of sieve worldwide. Only sieve supplied through OGSI is recommended in OGSI oxygen generators. Is all zeolite molecular sieve the same? Not all zeolite based sieves are the same, and can vary even by brands made in different locations (USA vs. foreign made). Can I use a regular air compressor, or do I need an oil free compressor? An oil free compressor is not required for PSA oxygen generation as long as the feed air quality is maintained. Why does OGSI use Atlas Copco Full Feature air compressors when other air compressors are sometimes cheaper? OGSI specifies Atlas Copco air compressors because of their overall value, dependability and the fact that they have the best international service network in the business.

Do oil free compressors cost more than regular compressors? Oil-free air compressors generally cost significantly more than oil lubricated versions. What happens if the air compressor malfunctions and oil is introduced into the air line? Excessive oil discharge from an air compressor can damage a PSA oxygen generator by contaminating the molecular sieve. Do I need a dryer for the air preparation? The feed air quality specification for OGSI PSA oxygen generators requires a dew point value of 40 degrees F (4 degrees C) or less. If the local ambient air conditions are above this value, an air dryer will be required. Do you need a desiccant dryer for the air prep or can I use a standard refrigeration dryer? A desiccant dryer is not required for air preparation, in most cases a refrigerated dryer is sufficient. Can I use a desiccant dryer if I want, and are there any advantages or disadvantages? A desiccant dryer can be used in place of a refrigerated dryer, and slightly better performance from the oxygen generator can be expected. However, this increase in performance may not offset energy and cost penalties. What happens if the air compressor malfunctions or stops working? If a required air dryer fails, damage to the PSA oxygen generator can occur due to moisture contamination of the sieve. Do you size systems differently for different altitudes? The size of the air compressor for a PSA oxygen generator has to be factored for site elevation. Higher elevations will require a larger air compressor. What is the purity of oxygen produced by PSA? The oxygen purity from OGSI generators can range from 93 to 95%, with 99% being optionally available. What is the dewpoint of the oxygen produced by PSA? The dewpoint of the produced oxygen from a PSA oxygen generator will be -60 degrees F (-51 degrees C) to -100 degrees F (-73 degrees C) depending on the generator size. What is the standard pressure of oxygen pressure produced by PSA? The output pressure from most OGSI oxygen (Model OG- 25 and up) generators is 45 psig (3 bar gage) to 60 psig (4 bar gage), with higher pressures optionally available by means of an oxygen booster. Do different models of oxygen generators produce oxygen at different pressure levels? The Models OG-15 & 20 produce oxygen at pressure of 9 psig (.62 bar gage) & 15 psig (1.03 bar gage) respectively. Can you increase the pressure to a higher level? The delivery pressure of oxygen from a PSA oxygen generator can usually be increased to the high end of the scale by decreasing the flow from the plant. Higher pressures would require an oxygen booster or compressor. Can you provide 7 or 8 Bar pressure? With an oxygen booster, pressures of 8 bar and above are possible. Liquid oxygen has a purity of 99%... is that better than 93 % oxygen? Liquid oxygen (LOX) at 99% oxygen purity may have some advantages for metal cutting, but not necessarily for medical applications. If the standard purity of PSA oxygen is 93% +-3%, can I take steps to produce oxygen at the higher end of range, for instance 95%? If a PSA oxygen generator is run at 80% or less of its rated output, continuous oxygen purity up to 95.3% is possible. Are there different pharmacopeia standards for 99% and 93% oxygen? The US Pharmacopoeia Standard, which is used by the US FDA and many other medical authorities, has oxygen specifications of 93% & 99%.

Why do some countries specify 99%? Some local authorities require 99% purity oxygen due to old regulations and ordinances. However, with the acceptance of international specifications from CSA (Canada) and ISO 10083 (European) these older specifications are being revised to 93%. What is the difference between an oxygen concentrator and an oxygen generator? These terms have been used interchangeably, with oxygen concentrator being the most technically accurate. Generically, oxygen concentrators describe smaller home medical systems, and oxygen generators describe all other size plants. If millions of people, world-wide, use oxygen concentrators that produce 93% oxygen on an everyday basis, why do some countries still specify 99% oxygen hospital supply systems? There have been powerful competitive interests that have lobbied local authorities to maintain a 99% medical oxygen purity standard to prevent the introduction of less expensive alternatives like PSA oxygen generators. Liquid Oxygen has losses where a certain amount of oxygen is lost to evaporation. Does PSI gaseous oxygen have the same problem? It is normal for a LOX storage tank to bleed off 1 to 4% of the tank volume to prevent pressure built-up. This is not a factor with PSA oxygen generators, all the oxygen that is produced can be used, there is no bleed off. Are there recommendations for a typical hospital oxygen supply system? There are CSA and ISO specifications that contain information on hospital oxygen systems. Can I monitor my oxygen generator system from a remote location? OGSI provides a Telemetric Communication Option for remote monitoring of the oxygen generator on Models OG-250 and larger. How do I size a hospital PSA oxygen system? Ideally, the hospital would design specifications or historical data to determine the plant size required. If this information is not available a formula can be used to estimate the peak oxygen required. Refer to the OGSI Hospital Application Note for details. What are some of the benefits of a PSA oxygen system compared to using cylinders or liquid oxygen? With a PSA oxygen system you eliminate all the cost and problems of delivered oxygen (higher prices, delivery costs, supply problems to name a few.) Are there concerns about carbon monoxide and carbon dioxide when producing gaseous oxygen using PSA technology? Most specifications for medical or breathable oxygen have maximum levels of carbon monoxide and carbon dioxide. It is important that the oxygen system has access to clean fresh air, and that a carbon monoxide and carbon dioxide monitor be used for medical or breathable applications. Is there equipment available that would allow OGSI to diagnose an oxygen generator problem from New York without having to travel to the job site? OGSI provides a Telemetric Communication Option for remote monitoring of the oxygen generator on Models OG-250 and larger. Can the system be set to automatically turn off if there are problems? Depending on what sensors are used (dewpoint, oxygen purity carbon monoxide and carbon dioxide levels, flow etc.) the plant can be configured to shut down based on any number of parameters. Can an oxygen cylinder get contaminated? It is possible that an oxygen (or any other type of gas cylinder) can become contaminated due to misuse. For this reason OGSI offers vacuum pumps on most CFP Models so that cylinders can be evacuated before they are filled. How long does an oxygen cylinder last and does it have to be re-certified on a periodic basis? The oxygen in a cylinder can last indefinitely. In the US, the DOT requires that aluminum cylinders be hydro-tested every (5) years, and steel cylinders every (10) years.

Do I need to use a vacuum pump to empty a cylinder before re-filling? It is never a bad idea to use a vacuum pump to empty a cylinder before it is refilled, especially if the cylinder is out of the control of the filler. This vacuum procedure can be eliminated if the cylinder is always in control of the filler. Do I need a carbon filter to produce medical grade oxygen? Carbon filters can provide an extra measure of filtration on medical or breathable oxygen systems, and additionally eliminate system odors. What is the most cost-effective oxygen cylinder filling plant? The OGSI Model CFP-500 and CFP-1000 provide two of our best values, due to optimal sizing of the oxygen compressor. Why do several models of cylinder plants cost almost the same, but produce very different amounts of oxygen? On smaller CFP s, the price does not change proportionately with plant size because of the standard equipment and instrumentation included with each skid. Also, there are only three standard sizes of oxygen compressors. Can I reduce the cost of my system and just use an oxygen monitor? If the application is not for medical or breathable use, costs can be reduced by eliminating the carbon monoxide and carbon dioxide monitor. How do carbon monoxide, carbon dioxide, and oxygen monitors work? Do they wear out? There are various different types of sensor technology available for gas monitoring. OGSI uses chemical depleting sensors, which have to be replaced over time. If I sell or rent cylinders of oxygen, how many cylinders do I need? It is generally accepted that a 10 to 1 ratio of cylinders is required based on the output of the plant. For example, if a CFP-500 produces (50) cylinders per day, then (500) cylinders may be required to service the market. This ratio may change if the customer supplies the cylinder. Are there different valves used on cylinders? For steel oxygen cylinders there are (2) major types of valves used worldwide, the US based type CGA 540, and the British based type BS # 3. What equipment do I need to transfill a small cylinder from a large cylinder? A high pressure flexible hose with an on/off valve and the corresponding cylinder valve connections at each end would be required. For safety, a containment vessel or chamber for the cylinder being filled is also recommended. How much does it cost to fill a cylinder of oxygen using PSA oxygen? For PSA oxygen generators, the cost for oxygen production, or cylinder filling is normally stated in kilowatt hours (KWH). The reason being that the air is free, but there is a cost of electricity to operate the air compressor. At a sea level site elevation, it will cost about 10 KWH to fill a 6m3 size oxygen cylinder, or 1.5 KWH per M3. How much energy does it take to run a PSA oxygen generator? The amount of power required to operate just the PSI oxygen generator is negligible, about 50 watts, for control circuits. How big is a PSA oxygen generator system? Most OGSI oxygen systems will fit into a 20 or 40-foot ocean shipping container. Can I mount a PSA oxygen generator system on a skid? Yes, you can mount a PSA oxygen generator on a skid, but it must be in the vertical position to operate properly. Does OGSI test every oxygen generator before shipping to the job site? Every OGSI oxygen system is tested at the factory. Distributed By: