Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

Similar documents
Installation, Operating, Maintenance and Safety Instructions for MAXI-SYSTEM Pressurised water systems for boats

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

OWNER S TECHNICAL MANUAL

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

Code AWC20HP Air Compressor

System Pressure Manager Standard & System Pressure Manager Plus

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Mainsboost Installation, Operation & Maintenance Instructions

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Electronic Control Pump Instruction Manual

Unit 24: Applications of Pneumatics and Hydraulics

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

200 PSI FAST-FILL AIR SOURCE KIT

Electronic Control Pump Instruction Manual

200 PSI HIGH-FLOW AIR SOURCE KIT

12V MINI AIR COMPRESSOR

Electronic Control Pump Instruction Manual

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

KJ4000 Operating Instructions & Parts Manual NSN

Hydraulic Reliability & Preventive Maintenance Report

12V Mini Air Compressor

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

Installation, Operation & Maintenance Instructions

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

Bar valve with fixed shower head Installation guide

100C Air Compressor Kit

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Budget Range Operators Handbook

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Model PSI Compressor with 3-Gallon Air Tank 12VDC

36H SERIES Combination Gas Valve

IMPORTANT SAFETY INSTRUCTIONS

R E D I C O N T R O L S

12 Volt Inflator. Operator s Manual. Model: ICC12F, ICC12FC, ICC12FCN, ICC12FCM, ICC12N

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Model 420-HY Pressure Regulating Hydrant Valve

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

444C DUAL PERFORMANCE VALUE PACK

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Operating Instructions Model and Hydrostatic Test Pump

400C & 450C DUAL PERFORMANCE VALUE PACKS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Replacement of Interchangeable Membrane

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

PRESSURISED PAINT CONTAINER

200 PSI COMPRESSORS - MODEL NUMBERS

SCA Series Inverted Bucket Steam Traps

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

NGP-250/500 Nitrogen Generator Quick Start Guide

MODEL NUMBER: P PORTABLE COMPRESSOR

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

553 Series.

Installation Instructions Air Compressor Part # 2780, 2781

Operator: Save these instructions for future use!

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

AIR COMPRESSOR MANUAL INSTALLATION, OPERATION AND MAINTENANCE GUIDE

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Compact Transfer Pump

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

COMPRESSOR REPLACEMENT PROCEDURE (R-134A)

24L AIR COMPRESSOR MODEL NO: TIGER 8/260 PART NO:

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Dual Solenoid Gas Valve Installation

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Warning: NEVER ALTER TEST EQUIPMENT

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

ENERGY BLADE 3K4. Energy Blade Installation Instructions

COUNTER CURRENT UNIT. Instruction Manual

KIT. Small Automatic Water Boosters KIT MODELS

TECHNICAL DATA. Trimpac 244a. September 16, 2013

AutoChanger Installation & User Guide Issue 2

Installation of Your SprayMaster System

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

New AQF Filter Polymer Filtration System

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Marschalk Model # 94000

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

SIMPLAIR PIPING TOOL. JXT Company

SPIROVENT VACUUM DEGASSERS

Transcription:

FLOMAX-SYSTEM DOC532/11 Installation, Operating, Maintenance and Safety Instructions for FLOMAX-SYSTEM Pressurised water systems for boats CW343A FloMax System 12 volt d.c. CW344A FloMax System 24 volt d.c. To obtain the best performance from your FloMax pressurised water system please read these instructions carefully. Failure to observe the recommended procedures may result in early and severe damage, and may invalidate the supplier s guarantee. Xylem Water Solutions UK Ltd Bingley Road Hoddesdon Hertfordshire EN11 0BU UK Telephone: +44 (0)1462 480380 Fax: +44 (0)1462 482422 mail@cleghorn.co.uk www.jabscoshop.com

APPLICATION The FloMax System has been designed to simplify the installation of pressurised fresh water systems in small vessels. It is supplied complete and ready for installation. It incorporates all the components necessary for a reliable supply of hot and cold running water on board your vessel - at the turn of a tap. INSTALLING YOUR FLOMAX-SYSTEM 1. Install the unit in a dry and accessible location in the engine compartment or elsewhere. 2. Keep the inlet pipe from the water supply tank as short as possible (2 metres maximum). The pump is self-priming, and may be mounted above the level of the water supply. Maximum vertical suction lift is 1 metre. A Jabsco strainer is fitted in the inlet pipework. 3. Fix the base plate firmly to a rigid horizontal surface. 4. The inlet pipe bore should be at least ½. Use Hep2o or reinforced hose that will not deform or collapse under suction conditions. The special Hep2o CW193W (straight) and CW194W (90º) connectors are designed to fit direct onto the inlet strainer threaded port. They are available from Cleghorn Waring and their stockists. 5. We recommend the use of Hep 2 O fittings to connect the inlet and outlet pipework into your system. Hep2o fittings HX31/15 and HX29/15W can be fitted to the FLOMAX discharge. HEP 2 O PUSH-FIT PIPEWORK IS STRONGLY RECOMMENDED light-proof to discourage growth of algae tough, flexible, ultra-simple to install joints remain fully watertight, even when rotated under pressure suitable for hot and cold water frost protected to 10ºC quiet, non-reverberating low heat loss 6. Discharge pipe of at least ½ bore is recommended: a smaller bore will reduce the flow rate obtained at the outlets. 7. Make sure that the motor voltage corresponds to your supply voltage. Use cable of the recommended size: Cable length, Metres 0-6 6-11 11-17 Conductor cross-section area 12 VOLT 2.5mm 2 4mm 2 6mm 2 24 VOLT 1.5mm 2 2.5mm 2 4mm 2 Note: Cable length is for line and return i.e. twice the run distance. If in doubt use the next largest wire size. 1

OPERATION 1. Check that the water supply tank is filled, and that the inlet pipe to the FLOMAX-SYSTEM is connected and airtight. The pressure in the accumulator tank has been pre-set and does not require adjustment. 2. Open all the taps and other outlets in the system. This allows the pump to self-prime easily. Follow the same procedure whenever the pump is restarted after running out of water. 3. Switch on the power at the master switch. The pump should start and prime itself, and water should flow from the open outlets within a short time. 4. Allow air to clear itself from each open outlet, then close it. The pump should run for a short period then stop automatically. The system is now operational. ALTERING PUMP PRESSURE SETTINGS If you need to change pressure settings, proceed as follows: NEVER try to alter settings without a pressure gauge (see below). 1. Switch on system and allow PUMP to start by opening an outlet. Close all outlets. The pressure showing on the gauge is the cut-out pressure of the unit. THE ACCUMULATOR TANK 2 2. Open one outlet slightly, allowing water to escape gradually. The pump will run once the pressure has dropped to the cut-in pressure. If the pump does not cut out again reduce the flow of water from the outlet until it does. 3. Using adjusting screw D on the pressure switch, raise or lower the cut out pressure of as required. If in doubt or difficulty, consult your pump supplier. Adjust screw R to alter the cut-in pressure. 4. Switch off the system and open a tap to release the water pressure. Adjust the accumulator tank pressure to approximately 0.2 bar below the cut-in pressure of the pump. Switch FLOMAX back on and allow air to clear itself from each open outlet, then close it. The pump should run for a short period then stop automatically. The system is now operational. FLOMAX is equipped with a 8 litre accumulator tank, pressurised with dry non-toxic nitrogen gas. It contains an internal membrane: a rubber bag that holds water. The tank acts as a pressure buffer, absorbing the flow from the pump when demand is low and smoothing outlet pressure. By removing the need for the pump to run immediately an outlet is opened, it extends pump life and reduces battery drain. The pressure in the tank has been pre-set by the manufacturer to approx. 3psi (0.2bar) below the cut-in pressure of the pump. It should not need to be adjusted prior to first use of FLOMAX. If the pumps start and stop instantly on opening or closing an outlet, or if it starts and stops rapidly and repeatedly, the accumulator tank is not working efficiently. Check the internal pressure and adjust it if necessary.

If adjustment of the accumulator tank pressure should become necessary (e.g. when altering working pressure settings on the pressure switches or when fitting a replacement tank) follow this procedure: Switch off the power supply to the pressure system and open a tap, allowing water to flow until it stops. Remove the valve cover to expose the valve. Using a tyre pressure gauge, release nitrogen from the tank until the pressure is approximately 3psi below the cut-in pressure of the pump. This operation should be carried out in a well-ventilated space. If the tank has been de-pressurised, or if too much nitrogen has been released from it, pump in air with a car or cycle tyre pump until the correct pressure has been achieved. Once the correct pressure is established, replace the valve cover and restart the pressure system by the method advised earlier in these instructions. If the internal tank membrane has ruptured, the accumulator tank will become inefficient. A ruptured membrane will also release water into the dry volume of the tank. Water or bubbles emerging from the tank valve are signs of a ruptured membrane. Traces of rust may eventually appear in the water coming out of the tap. The accumulator tank will need to be replaced. MAINTENANCE Your FLOMAX-SYSTEM is designed to operate without frequent maintenance, but the following procedures will help to ensure that the system gives you lengthy and trouble free service. 1. Check the inlet strainer periodically, and clean if necessary. 2. Every 6 months, check the pressure in the accumulator tank. Disconnect the electrical supply, open a tap until flow ceases and unscrew the end cap from the accumulator tank to expose the air valve. Use a car tyre pressure gauge to check the pressure in the tank. The accumulator tank pressure to be approximately 0.2 bar (3 psi) below the cut-in pressure of the pump. Air may be pumped in to raise the pressure if necessary, using a suitable foot or hand pump. TROUBLE SHOOTING Problem Pump does not prime: motor runs but no discharge Motor fails to start when switched on Pump fails to turn off with all outlets closed Possible cause Restricted or blocked inlet or discharge pipe. Air leak in inlet pipe Dirt under pump valves. Pump diaphragm leaking Supply tank empty Loose wiring connection No power in pump circuit Blown fuse Failed pressure switch Supply tank empty Inlet or discharge pipe leak Insufficient voltage at pump Failed pressure switch 3 Action Check pipes & strainer Check for leaks Check valves Check diaphragm Fill tank Check wiring Check power source Check cause and replace Replace pressure switch Fill tank Check for leaks and repair Check supply voltage & cable Replace pressure switch

Pump runs intermittently with all outlets closed Dirt under valves allowing leakage to suction side of pump Leaking pipework on discharge side of pump FLOMAX SYSTEM PARTS REFERENCE Check valves Check strainer Check pipework KEY DESCRIPTION QTY PART NUMBER 1 ACCUMULATOR TANK 1 CW288 2 PAR-MAX 3 PUMP 1 31600-0292 12 VOLT 31600-0294 24 VOLT 3 PRESSURE GAUGE 1 CW218 4 PRESSURE SWITCH 1 CW4-A 5 Hep 2 O ELBOW 2 HD5/15A 6 Hep 2 O MALE ADAPTOR 1 HX31/15 7 BASE 1 Z/CW402 8 STRAINER 1 46400-9500 PRESSURE SWITCH SETTINGS CUT-IN PRESSURE CUT-OUT PRESSURE 0.7 bar ( 10 psi ) 1.4 bar ( 20 psi ) INLET CONNECTION ½ BSP MALE DISCHARGE ½ BSP FEMALE 4