Residential and Small Commercial

Similar documents
Service Regulator Requirements

R600 and HSRL Series Instruction Manual

R122H, R222, R232A, and R232E Series Instruction Manual

Types 749B and R130 Changeover Manifolds

New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

G IG-2. INSTALLATION AND INSPECTION OF GAS SERVICE REGULATOR VENT LINE PROTECTORS (VLPs) [Interim Guideline]

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

R600 and HSRL Series Instruction Manual

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

September 2018 Pressure Test

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

GAS DELIVERY PRESSURE AND MEASUREMENT

Types S100K and S102K Pressure Regulators

GAS SUPPLY APPLICATION GUIDE

Inspecting LP-Gas Regulators

Operating and Maintenance Instructions

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

G96 Series BASOTROL Dual Operator Valve

TECHNICAL DATA Q= C. Table 1 - Specifications

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

TECHNICAL DATA. Table 1 - Specifications

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

S300 Series. Valve Link. Features. Fisher Controls

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

G REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED SYSTEM PROTECTIVE DEVICES

GAS SUPPLY DESIGN GUIDE

Inert Air (N2) Systems Manual

Vision Painting Inc Safety Management System

SIZING AND CAPACITIES OF GAS PIPING

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

First Stage Regulators

Tri-Tech Medical Inc.

G92 Series BASOTROL Automatic Pilot Gas Valve

Committee Input No. 59-NFPA [ Section No. 5.9 ]

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

/2004 US/CA

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

29 SERIES - SAFETY VALVE

Operator: Save these instructions for future use!

KC Series Gas Components and Supply Design Guide

Certified LP/Propane Line Pressure Regulator Guidebook

1800C and 1800C-HC Service Regulators

Type R622 Pressure Reducing Regulator

ECS Protector Nitrogen Inerting Vent (PAV-WN)

Installation Instructions

Installation, Operation, and Maintenance Manual

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Installation of Your SprayMaster System

627 Series Pressure Reducing Regulators

TECHNICAL DATA. Q= Cv S

North American 7339 High Pressure Gas Regulators

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

CAPITAL CONTROLS SERIES NXT3000

SERIES SAFETY VALVE

LP-10 LP-GAS SERVICEMAN'S HANDBOOK

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

LINE PRESSURE REGULATOR GUIDEBOOK 7TH EDITION

Swimming Pool Requirements Packet

TECHNICAL DATA. Q = C v P S

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

RESIDENTIAL SWIMMING POOLS AND SPAS A GUIDE FOR HOMEOWNERS

SIZING AND CAPACITIES OF GAS PIPING Reserved

INSTALLATION GUIDE Gas Rangetops

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Pilot Check Valve: Metal Body Type

GAS FUEL VALVE FORM AGV5 OM 8-03

Noth American 7347 High Pressure Gas Regulators

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

SIZING AND CAPACITIES OF GAS PIPING

Series 100 Slam Shut Valve. Technical Bulletin

ACCESSORY KIT INSTALLATION MANUAL

1805 Series Relief Valves

Aquavar SOLO 2 Frequently Asked Questions

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Summary of the MRA LPG Codes of Practice

36H SERIES Combination Gas Valve

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

Draft. Not yet Approved

CHAPTER 13 FUEL GAS PIPING

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

1800C & 1800C-HC Service Regulators

LP-Gas Serviceman s Manual

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

Transcription:

Page 1 of 7 Companies Affected: NIPSCO CGV CMD CKY COH CMA CPA REFERENCE 49 CFR Part 192.353, 192.355, 192.357 1. GENERAL The purpose of this standard is to provide requirements for the inspection or installation of residential and small commercial regulators installed on piping systems with operating pressures greater than low pressure (>LP) to a maximum allowable operating pressure (MAOP) of 100 psig. All service regulators showing external corrosion or damage shall be replaced. These requirements apply to the initial installation and any subsequent re-design or relocation requested by the customer. Any relocation of a gas meter necessary to meet this installation requirement shall be charged to the customer per the guidelines in gas standard 160-0032. Note: Mercury regulators and/or external mercury relief devices encountered in the field shall be removed as soon as practical. Upon discovery and prior to removal of a mercury regulator and/or external mercury relief device, a member of the Operations Center leadership team and a member of the Environmental Department shall be notified. Inspect the area beneath the regulator and/or relief device for evidence of a previous mercury spill and take precautions to ensure that any mercury is not disturbed or tracked through the building. Never attempt to remove a mercury regulator and/or external mercury relief device without assistance and guidance from a member of the Operations Center Leadership team and a member of the Environmental Department. 2. LOCATION Gas meters and service regulators shall be located per the drawing in Exhibits A and B and at a location that is accessible for reading, inspection, servicing and operation of the shut-off valve. Additionally, residential, electric and gas meters should both be located on the same side of the building within the front 1/3 and if possible within 10 feet from the front corner to aid meter reading, testing, maintenance and to allow quick access for emergency response. If possible, locate the meter riser to avoid the need to cross over an existing underground electric line when the service line is installed from the main. When more than one meter is being set on premises (a tract of land and its buildings) they shall be connected to the same service line and installed at one location, except where This document is considered CONTROLLED only when viewed electronically on the Company's intranet. Printed or other electronic copies may not be current, and the intranet version should be used to verify.

Page 2 of 7 impractical. Service regulators are to be located where gas from the vent can escape freely into the atmosphere and away from any opening(s) into a building. 3. SERVICE REGULATOR REQUIREMENTS The Company s standard billing and delivery pressure is 6.5 inches water column (6.5 w.c.). Consideration should be given as to the location of the service regulator and/or relief device to avoid sources of ignition and the possibility of vent terminal freeze-ups. Regulator vent skirts or a vent line extending the vent terminal away from the potential source of moisture should be considered if the potential for vent terminal blockage due to freeze-up is evident. 3.1 Service Regulator Vent Requirements The regulator and/or relief device vent; vent line, if so equipped; screen; and cap, if present; shall be properly sized, installed, and free of blockage, restrictions or valves, with no external leakage. 3.1.1 Aboveground Vent Lines When a regulator and/or relief device is located inside a building, each regulator and/or relief device shall have a separate metallic relief vent line vented to the outdoors so in the event gas is discharged, it will not create a hazard- under no circumstances shall the relief vent lines of separate regulators and/or relief devices be manifolded. If tubing is used for the relief vent line, it shall be metallic and one size larger than the relief opening in no case shall corrugated tubing be used as a regulator relief vent line. Relief vent lines shall be as short as possible, and when in excess of 10 feet in length or contain more than two (2) elbows, shall be increased one nominal pipe size for each additional 10 feet of length. Each elbow in the vent line will contribute approximately three (3) feet in effective length, including the termination elbow. Service regulators installed outdoors of a building requiring a relief vent line, may be equipped with a PVC vent line conforming to UL 651, schedule 40 or schedule 80 rigid PVC conduit. Under no circumstances shall the relief vent line be combined with another regulator relief vent line. The same sizing guidance provided above applies. 3.1.2 Belowground Vent Lines That portion of the regulator vent line that is exposed shall be installed in

Page 3 of 7 accordance with the requirements set forth in section3.1.1 of this standard - under no circumstances shall the relief vent lines of separate regulators and/or relief devices be manifolded. When no other alternatives exist and it becomes necessary to install a portion of the regulator vent line underground, that portion of the belowground vent line shall be constructed of steel pipe in accordance with the requirements in 3020 series of the s and protected against corrosion in reference to the 1400 series of the s, or polyethylene pipe installed in accordance with the 3020 series of the s. Relief vent lines shall be as short as possible, and when in excess of 10 feet in length or contain more than 2 elbows (including the termination elbow), shall be increased one nominal pipe size for each additional 10 feet of length. Each elbow in the vent line will contribute approximately three (3) feet in effective length. All elbows and fittings shall be welded by a qualified welder in accordance with the applicable company Welding Manual. 3.1.3 Service Regulator Vent Terminal Requirements Note: All measurements shall be taken from the service regulator vent terminal (relief opening) (see Exhibits A and B). Except as noted below, the vent terminal: a. Shall be installed outdoors above grade, at a minimum height of 12 inches. b. In areas where flooding may occur, a minimum height in excess of 12 inches may be required to prevent the entry of water into the vent terminal. c. Shall be installed to protect it from the entry of insects by a screen or an approved vent cap, and be installed so as to prevent the entry of rainwater. d. Shall be located not less than three (3) feet radially and not directly below any rotating electrical equipment (e.g., an air conditioning unit). e. Should be installed with a minimum of three (3) feet radial separation from an electric meter, electric panel, electric outlet, electric pedestal, electrical equipment disconnect, or pad mounted transformer, etc. When it is not possible to install the regulator vent terminal with a three (3) foot radial separation, a minimum of one (1) foot radial separation shall be maintained between the regulator vent terminal and any of the electric equipment listed above. f. Shall be located three (3) feet radially from, and not below, any first

Page 4 of 7 floor opening into a building, such as a door, window(s) (that can be opened) or other gravity air opening(s) into a building (including clothes dryer exhaust terminals, and appliance air intakes). g. Shall be located not less than 10 feet radially from, and not below any forced air inlet into a building (excluding appliance air intakes). Note: It may be acceptable for reduced clearances from building openings and potential sources of ignition when approved self-operated diaphragm service regulators equipped with over pressure protection and vent limiting devices are installed. 4. ESTABLISH/REESTABLISH SERVICE Refer to the procedures in the Customer Service Handbook for establishing/reestablishing service. 5. RECORDS Record the necessary information on the MDT Order, including pertinent information regarding the service regulator(s).

Page 5 of 7 EXHIBIT A

Page 6 of 7 EXHIBIT B

Page 7 of 7 EXHIBIT C