Question : What are some tips and recommendations and choices for roof venting?? Part One

Similar documents
VAV SYSTEM INDOOR AIR QUALITY CONSIDERATIONS FOR OFFICE SPACES

Mott Manufacturing Limited

Lecture 11 Natural Ventilation (Passive Cooling)

The Hoffman Specialty Series 2000 consists of main

Thermal design of APFC Panels

Series 3000 Layout Guidelines

The Classroom Environment

The Stack Effect. Mat Ansari PE

FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN

Defining Terms. Types Of Ventilation Systems: Types Of Ventilation Systems: Natural Ventilation - Winter

Quick Reference Technical Data

Good News From the Doctor

Mott Manufacturing Limited

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

OVERVIEW. Flow Coefficient C v. Operating Conditions. Specific Gravity

Airtightness Testing in Large Buildings: NESEA 2016

Sizing Enclosures for SCR Power Controllers

Paw Q Story 10/9/ Steps to Drier Houses & Better Paw Quality. Step 1 Manage Moisture

PLEA th Conference, Opportunities, Limits & Needs Towards an environmentally responsible architecture Lima, Perú 7-9 November 2012

HAP e-help. Obtaining Consistent Results Using HAP and the ASHRAE 62MZ Ventilation Rate Procedure Spreadsheet. Introduction

STORAGE OF HAZARDOUS CHEMICAL AGENTS (HCA)

Double L Group, Ltd. TJP Inlets Number & Placement of Inlets Using Summer Fans with Minimum Ventilation on Endwalls

Meteorology & Air Pollution. Dr. Wesam Al Madhoun

External Influences. thermal science. Forward. Recirculation ON COOLING TOWER PERFORMANCE

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

COATINGS SPRAY GUIDE Urethane 520

Exercise on Projectile Motion (Unit-III)

BACK PRESSURE / SUSTAINING

Design wind pressures and forces are determined per equations given in section : q Gf Cp - qi GCpi : at height z above ground Resisting System

CHAPTER 5 CULVERT DESIGN

CK-12 Geometry: Special Right Triangles

BACK PRESSURE / SUSTAINING

GEMINI 8-M Telescopes Project

MEASURING AIR FLOW. Ventilation (Outside Air) Calculations. Derive % of OA as part of total air flow using air temperatures:

SECTION 2 APPLICATION OF FUNDAMENTALS

OIL AND GAS INDUSTRY

Hot Tub Pre-Delivery Guide

A building equipment operation, weather and pollution protection

The Art of Natural Ventilation Balancing Heat and Air Flows?

Models 106-RF / 206-RF Rate of Flow Control Valve

VENTILATION DURING TUNNEL CONSTRUCTION INDUSTRY CONSIDERATIONS

09 - Choosing /sizing a cylinder and valve

Ventilation of Small Multispan Greenhouse in Relation to the Window Openings Calculated with CFD

Results of Field Measurements and CONTAM Simulation. Building Science

Understanding Lobe Blowers Roots Blowers. Article written by Technical Team of EVEREST GROUP

AN IMPROVED CROSS VENTILATION MODEL IN WINDY REGIONS

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES

Meteorology 2/6/2017. Wind, and its Interaction with Particle Plumes. Variation of wind speed with elevation. Variation of wind speed during the day

Increase in Evaporation Caused by Running Spa Jets swhim.com

Theory, Application, and Sizing of Air Valves

Loads on Structures. Dead Load / Fixed Load Live Load / Imposed Load Earthquake Load Wind Load Snow Load

Application Worksheet

INTERPRETATION IC OF ANSI/ASHRAE STANDARD VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY

The process of measuring air

1. PRODUCT INFORMATION

The Application of Temperature and/or Pressure Correction Factors in Gas Measurement

Automatically or individually calculated.

Calculus 12: Evaluation 3 Outline and Review

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA

vento specification sheet

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Grade 3 TEAM TRAVEL: DISTANCE. Warm Up. Overview. Materials. Essential Question. Standards

Theory, Applications and Sizing of Air Valves

AVEMS & UNICLIMA joint Position paper on Regulation (EU) No.1253/2014 Paris, June 8 th

QT2 Triathlon Calculator

DAV - P. Product Catalogue DAV - P. Air release & Vacuum Break Valves. (Plastic Air Valves) DAV - P. Edition 2012

Evaluating Surge Potential in CSO Tunnels

Fundamentals of Turboexpanders Basic Theory and Design

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

AP Physics 1 Summer Assignment 2017

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Squire-Cogswell

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

PRE-TEST Module 2 The Principles of Flight Units /60 points

4-3 Rate of Change and Slope. Warm Up. 1. Find the x- and y-intercepts of 2x 5y = 20. Describe the correlation shown by the scatter plot. 2.

Gas Gathering System Modeling The Pipeline Pressure Loss Match

RATE OF CHANGE AND INSTANTANEOUS VELOCITY

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax:

Single & Headered Relief Vent Piping Analysis

Trout farm has 5000 gallons of water flow through the trout farm that stays open in winter & summer.

AIR FOAM CHAMBER DATA SHEET

US / 1400 Bubblers 1800 SAM-PRS 1800 SAM- PRS-45

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

AIR CONDITIONERS WA14 SERIES

Controlling Cabin and Envelope Air Flows & Pressure Differentials

EXPERIMENTAL RESEARCH ON THE MECHANICAL SOLICITATIONS OF THE GREENHOUSES OF VEGETABLES AND FLOWERS LOCATED ON ROOFTOPS

ADA Operations Contact Info

SIZING AND CAPACITIES OF GAS PIPING

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

2011 Excellence in Mathematics Contest Team Project Level I (Precalculus and above) School Name: Group Members:

COATINGS SPRAY GUIDE Fast Set Urethane 530

This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or

4 Testing Agency Guide. 4.1 U.S. Army Corps of Engineers (USACE) Standard for Air Leakage

Experimental Characterization and Modeling of Helium Dispersion in a ¼-Scale Two-Car Residential Garage

SIZING AND CAPACITIES OF GAS PIPING

Effect of airflow direction on human perception of draught

Transcription:

Greenhouse - Q and A TIPS AND ADVICE Agroponic Industries Ltd. Calgary, Alberta, Canada ph 403 241 8234 email: agropon@agroponic.com Ask the Experts Question : What are some tips and recommendations and choices for roof venting?? Part One The most common question is what size of vent do I need. This is an important question but there are several other factors to consider other than how many sq. feet of vent you require. Height differentials plays a very major role in the performance of your vent system. General Natural Ventilation Rules Natural Venting of Greenhouse Structures Several general rules should be observed in designing a greenhouse for natural ventilation. ( I.e.: By roof vents/ridge vents or gutter vents and or sidewall vents. ) Systems using natural ventilation should be designed for effective ventilation regardless of wind direction. THERE MUST BE EFFECTIVE VENTILATION WHEN THE WIND DOES NOT COME FROM THE PREVAILING DIRECTION. The greatest flow per unit area of total opening is obtained by using inlet and outlet openings of equal area. The neutral pressure level tends to move to the level of any single opening, with a resulting reduction in pressure across the opening. [1]

There must be a vertical distance between the vents for temperature difference to product natural ventilation. THE GREATER THE VERTICAL DIFFERENCE, THE GREATER THE VENTILATION ( flow ) rate will be. Openings near the neutral plan level are least effective for ventilation. Protect roof vents against high winds / rains with outdoor weather stations. FLOW DUE TO THERMAL FORCES In most greenhouses, there is no significant internal resistance to affect total flow rates so this formula is an effective tool. Q = C * A * sq. root(h(t1-t0)/t1) where Q = flow, L/s or CFM A = free area of inlets or outlets, Sq.M or Sq. Ft. h = height from inlets to outlets, M or ft t1= indoor temperature at height h, Deg C or Deg F t0=outdoor temperature, Deg. C or Deg. F C = constant of proportionality, 116 (if metric ), 9.4 This applies if t1>to, if t1<to replace t1 in denominator with t0. Reference source ASHRAE - fundamentals handbook Interesting formula for sure and it does work. Backing up to the basic rules though please note, sure the areas of the openings are important... but... what is really important is the height differential between the openings. Let's look at a couple situations. Common factors... no wind. Inside temperature up at roof vent 120 deg. F. Outdoor temperature 85 deg. F. Roof vents total area of 500 sq. feet. ( 1/2 inlet / 1/2 outlet, 1000 sq. ft. total ) and are located at same distance from the peak. Both houses at 240 feet long. House 1 was built using a slope of 1/4" per 12 feet for roof drainage. House 2 was built using a slope of 1 1/2" per 12 feet for roof drainage. Will the vents on both houses work the same at the same common factor conditions??? Nope... house 2 will always provide more ventilation than house one. Remember the height differential plays a very very strong role. House one has a total elevation drop of 5" along the length of the gutter or and average of 2.5" (.4' ) House two has a total elevation drop of 30" along the length of the gutter or and average of 15". ( 1.25') House one will ventilate 19,810 CFM House two will ventilate 36,020 CFM Just due to the thermal force acting. Hm... same house.. but with different slopes on the gutter. I know which house I'd build, if cooling was a concern. Remember the height differential plays a very very strong role. [2]

How to improve house number one???? It's easy. You don't need to add exhaust fans. Just introduce some low level openings... how about sidewall vents or shutters... As an example on house # one... if only 200 sq. feet of low level vent/shutters were added and were centered at the 6 foot mark off grade. The vents on the roof are 14 feet above grade. This provides a height differential of 8 feet. All other conditions the same. Now the roof vents will flow 46,00 CFM air flow at a ratio of 500/200 ( 500 sq. feet of roof vent --- 200 sq. feet for the sidewall vent area ). No...that's an increase on air flow. The thing to note: It is not always the size of the vent but the height differentials between the vents. Flow Due to Wind Remember it is foolish to size the vents based on prevailing wind ( we know many companies and suppliers do... but it is foolish ). Here's a handy little formula. Required Flow Q=CVAv Q = air flow in L/sec or CFM A = area if inlet openings v = velocity of wind, M/sec or MPH Cv = constant of effectiveness of openings ( 0.50 to 0.60 with wind perpendicular, 0.25 to 0.35 for diagonal wind ) A 10 MPH wind acting perpendicular on the above examples would cause an extra 7500 CFM air flow in and out of the structure. The required flow is dependent on the total heat to be removed and the difference between outdoor and indoor temperatures ( at the vent heights ). As an example, a greenhouse is subjected to a total conducted and solar gain load of 3,600,000 BTU's, 120 deg. F at the vent opening and 85 deg. F outdoor air, the required air flow rate would be 93,294 CFM. Based on air density of 0.075 lbs/cubic feet, specific heat of 0.245 BTU/lbF. Using the above formulas you them can figure out the vent sizes that you need. Just remember... Closely read and consider the ventilation rules. If you do so... Your ventilation blues can be solved. Common Venting Methods [3]

[4]

[5]

[6]

Agroponic Industries Ltd. ph 403 241 8234 email : agropon@agroponic.com web : www.agroponic.com Consultants, Suppliers and Installer to the Commercial Greenhouse Industry [7]