Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Similar documents
Rev. B. Operating Instructions

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

PRODUCT INFORMATION AND INSTRUCTIONS OM-810

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

AUTOVENT 4000 VENTILATOR

- GAS REGULATOR - COMPACT STYLE

Welcome to the Specialized Medical Services Respiratory training webinar series!

Dialflow Regulator. Instructions for Use

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

SERIES-O REGULATOR. Instructions for use

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Yoke Block Instruction Manual

Yoke Block Instruction Manual

CPR MEDICAL DEVICES INC. OPERATING MANUAL

PRODUCT INFORMATION AND INSTRUCTIONS OM-411A OM-411AF

U S E R M A N U A L. (CGA 870 Connection)

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

INSTRUCTIONS FOR SINGLE STAGE LECTURE BOTTLE REGULATORS

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

Pressure Regulators. Operating Instructions. Instrumentation

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

Home Oxygen Therapy Patient Handbook

Liquid Oxygen- Helios & Helios Marathon A Guide for Patients in the Home

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

Oxygen Dialflow Meter. Instructions for Use

Oxygen Dialflow Meter. Instructions for Use

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

AND OPERATION INSTRUCTIONS

U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS

Micro Dial-Flowmeter. Instructions for Use

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Pressure Regulators. Instructions for Use

INSTRUCTIONS FOR MODELS APC & APG HIGH PURITY, CORROSIVE GAS REGULATORS

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

CS150 CAP STAPLER OWNER S MANUAL

Product Information News

INSTRUCTIONS FOR MODEL TSC LOW DELIVERY PRESSURE GAS REGULATORS

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Invacare Element Pneumatic Conserver

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Pressure Regulator. Instructions for Use

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G96 Series BASOTROL Dual Operator Valve

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

FLANGED TWO-PIECE BALL VALVES

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Portable oxygen concentrator

Oxygen Usage Best Practice Guide

V-24 OXYGEN LANCE VALVE

623 Series Dome Load Regulators

EvolutionTM OM-900 PRODUCT INFORMATION AND INSTRUCTIONS OXYGEN CONSERVER

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

HELiOSTM Plus & Marathon

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

RG3100 and RG3100Ice Regulator System

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

AIR/OVER HYDRAULIC JACK 20 TON

PRODUCT INFORMATION AND INSTRUCTIONS OM-900M

HomeFill II Oxygen Conserving Cylinder

U S E R M A N U A L CAUTION. Models: 19MFA Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

RG2200 BC Integrated Octopus

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

USER MANUAL Series (CGA 870 Connections) SAVE THESE INSTRUCTIONS

with O 2 Controller Instruction Manual


Medical oxygen. LIV IQ Digital therapy device.

AIR INLINE METAL SHEAR

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Breathing Devices. Chapter 8 KNOWLEDGE OBJECTIVES SKILL OBJECTIVES. 6. List four precautions to take when using oxygen.

Companion 5 TM. Oxygen Concentrator. User Manual

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Offset head dual chuck

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Interface Devices, Inc. Hydraulic Mini Mule

In this manual; Warnings, Cautions and Notes calls your attention to information provided to help ensure your safety. Always dive safely.

Rejuvenation Instructions

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS

2 PRE USE FUNCTION CHECK 3 OPERATING PROCEDURE 4 SERVICING. 5 CAREvent ALS ACCESSORIES 11

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

OPERATING AND MAINTENANCE MANUAL

Transcription:

Operating Instructions Table of Contents Resource v.2 Conserving Regulator Safety Information Device Precautions Introduction Product Features Product Specifications Feature Illustrations Set Up Usage Removal From Oxygen Cylinder Cleaning And Maintenance Warranty 2

Safety Information This chapter defines the signal word warnings (Danger, Warning, Caution, Note) that appear throughout this manual. The warnings are inserted in the manual whenever deemed necessary. This section also describes safety hazards encountered in normal use or misuse. Read all instructions and safety information BEFORE using this device! DANGER NOTE! CAUTION Danger means a hazard that will cause death or serious injury if the warning is ignored. Warning means a hazard that may cause death or serious injury if the warning is ignored. Caution means a hazard that may cause minor or moderate injury to a person, or damage to property, if the warning is ignored. A NOTE indicates a recommendation or company policy. The message may relate directly or indirectly to the safety of the user or protection of property. A NOTE is not used in place of "CAUTION", "WARNING", or "DANGER" notice. Device Precautions The user must understand and apply the following general safety precautions when using this device. These precautions may or may not be included elsewhere in this manual. Read ALL instructions before using.! DANGER THIS PRODUCT OPERATES WITH HIGH PRESSURE OXYGEN - USE NO OIL Keep grease and oil away from the device at all times. Do not smoke while using this device or anytime oxygen is in use. Do not expose device to any flames or sparks. Service on this device should be performed only by an authorized service facility. Do not use the device if it has been tampered with in any way. When mounted to an oxygen source, internal components of the device may be under extreme pressure. Improper assembly or handling could result in explosion or fire. Failure to close the cylinder valve before removing the regulator from the cylinder will result in rapid de-pressurization of the cylinder and a fire could result. This product vents a small amount of oxygen when used. Do not use this product under clothing or in any way which could trap oxygen and cause a fire. Only use the accessories provided with this unit. Any unit that does not meet the performance requirements outlined in this manual should not be used. Contact a technician. 3 4

Device Precautions, cont'd! CAUTION Federal law restricts this oxygen conserving device to sale by, or on order of, a licensed physician. This device must be used only under the supervision of a licensed physician. Anyone handling this device should have clean hands that are free of greases, oils, hand lotions, petroleum jelly, or any other similar products. This device will not function properly if exposed to excessive moisture or excessive salt spray. Do not use the device with a humidifier. Do not expose this device to extreme temperatures. Do not use the device if the oxygen tubing is kinked or obstructed. Backpressure downstream of the device may cause a restriction in flow. NOTES: This device is only to be used by patients requiring supplemental oxygen and only when a nasal cannula is prescribed. Be sure the device is free of contaminants before installing. Turn off oxygen supply when not in use. Do not use this device to sustain life, or while the patient is sleeping. The use of this device for gases or pressures other than those outlined in this manual is expressly prohibited by the manufacturer. Be sure the oxygen hose is attached snugly to the outlet barbs. Use only with standard dual-lumen cannula. Do not use with pediatric (low flow) nasal cannula or mask. Do not use with patients who consistently fail to trigger equipment (e.g., mouth breathing or light breathing patients). 5 Introduction The Resource v.2 Conserver The Resource v.2 Oxygen Conserving Regulator is a high-pressure oxygen regulator and conserving device that is combined into a single compact unit. It operates in the same manner as traditional oxygen pressure regulators with the added benefit of having a conserving device included. The system is designed for use by an ambulatory patient with a high-pressure oxygen cylinder. Since the Resource v.2 requires no electrical (battery) power source, it is a reliable and easy to use device. Function of the Device. Like traditional click-style oxygen regulators, the Resource v.2 can function as a standard continuous flow regulator. However, it is also a conserving device which will double a patient's ambulatory time over that of continuous flow oxygen systems. In the Conserving Mode, the flow of oxygen is controlled by the patient's inhalation and exhalation, which triggers a sensing diaphragm within the control module. As a result, the unit starts flowing oxygen when the user begins his/her inhalation cycle. Conversely, the unit shuts off the flow of oxygen when the user ceases inhalation. In either mode, the Resource v.2's flow rates are adjusted by setting the flow control knob at the prescribed flow rate. Also, the device can be easily switched between continuous or conserve mode without turning the device off. 6

Features and Specifiations Feature Illustrations FEATURES The Resource v.2 is a combined regulator and conserving device. It provides therapy and conserves oxygen by delivering the patient's prescribed liter flow only during inhalation. The user can switch between Continuous and Conserve Mode simply by turning a knob The device has a compact one-piece aluminum body with all-brass in the high-pressure zone. It includes a click-style flow control with 11 flow settings. For additional safety and longer device life, it has a sintered bronze high-pressure inlet filter. Flow setting Mode selector knob Regulator Flow/Mode setting indicator Seal washer SPECIFICATIONS: Operating pressure: 200 to 3000 PSIG Outlet pressure nominal: 22 PSI Selectable outlet flow: 1-6 LPM by.5 LPM increments Oxygen Conservation: Nominal 50% at all settings based upon an average I:E ratio. Inlet Configuration: CGA 870 Pin Indexed Yoke Outlet connection: Cannula hose barb Unit weight 16 oz (1.0 lbs) 1-1/4" diameter gauge Flow selector knob Delivery port Vent hole Sensing port Cylinder contents gauge Yoke pins "T"-handle 7 8

! CAUTION Set Up Keep cylinder valve closed at all times when the cylinder (or Resource v.2) is not in use. 1. Be sure the sealing washer is in place on the inlet yoke. Do not use more than one sealing washer and be sure the sealing washer is clean and in good condition. Only use sealing washers approved by the Cramer Decker Medical, Inc. -- DO NOT use plastic seal washers. Be sure the inlet area is free of contaminants. Set-up, cont'd Never stand in front of or behind the Resource v.2 when opening the cylinder valve. Attach it to the cylinder valve with the outlet ports facing downwards. Open the cylinder valve SLOWLY until oxygen begins to flow into the regulator. Check for audible leaks around the cylinder connection. If leaks are detected, turn off the cylinder valve and re-tighten the connection. SLOWLY reopen the cylinder and check again. If leaks are still detected, do not use the Resource v.2 -- call a technician.! CAUTION Anyone handling this device should have clean hands that are free of greases, oils, hand lotions, petroleum jelly, or any other similar products 4. In the "Conserve" mode, this device should be used only with Hudson dual lumen cannula part number 1850 or a cannula approved by Cramer Decker Medical, Inc. 2. Inspect the cylinder valve and the device to ensure they are clean and free of contamination. 3. Attach the Resource v.2 to the cylinder valve by placing the two yoke pins (on the Resource v.2) into the matching holes on the cylinder post valve. Align the pointed end of the T-Handle with the round depression on the opposite side of the post. 9 10

! CAUTION Usage To ensure proper flow from the Resource v.2, the patient must use the dual lumen cannula provided with the product or replacement cannulas approved by Cramer Decker Medical, Inc. Do not use with a cannula more than 5 feet long. Breathing exclusively through the mouth, extremely light breathing, or nasal blockage will inhibit the device from delivering oxygen flow. Breathing through the nose is required for the unit to operate. Be sure the cannula is properly attached to the hose barbs and there are no kinks or obstructions in the tubing. The adjusting knob must be set at a marked flow setting. Placing the knob between settings will result in inaccurate flow or no flow at all. Do not cover or block vent holes in the device with labels, decals, adhesive material or any foreign object. Blocking vents will cause the conserver to fail, resulting in a reduced or no flow condition and/or an unsafe high-pressure condition. Location of Flow Selector and Mode Selector Knobs Flow selector knob Flow setting (LPM) Mode selector knob To Use the Resource v.2 Usage, cont'd NOTE: The flow selector knob on the end of the regulator allows the user to select the oxygen flow rate in liters per minute. The flow selector knob "clicks" into the specified flow rate settings on the knob. Oxygen will not flow out of the regulator if the knob is set between the indicated flow settings. Set the flow selector knob to the desired flow setting. Attach the cannula to the Resource v.2 outlet ports. Place the nasal portion of the cannula into the nose as directed by the oxygen therapist. Breathe through the nose. To Switch from Continuous to Conserve Mode This oxygen conserving unit is capable of delivering flow in two modes: Conserving Mode, which delivers flow only during inhalation. Continuous Flow Mode, which delivers a constant flow, regardless of breathing patterns. To select Conserving Mode, turn the mode selector knob on the top of the device until the "Conserve" indicator is aligned with the "Flow/Mode" indicator. The knob should click into place. To select Continuous Flow Mode, turn the knob on the top of the device until the "Continuous" indicator is aligned with the "Flow/Mode" indicator. The knob should click into place. Flow/Mode setting indicator 11 12

Removal from Oxygen Cylinder Failure to close the cylinder valve before removing the regulator from the cylinder will result in rapid de-pressurization of the cylinder and a fire could result. NOTE: It is not necessary to remove the regulator unless the cylinder is being exchanged for a new one. To remove the Resource v.2 from the cylinder: Close the cylinder valve. Set the adjusting knob to the lowest flow setting and allow the regulator to de-pressurize. Be sure the contents gauge reads zero. Remove regulator from valve. Cleaning and Maintenance The exterior surfaces can safely be wiped off with a clean, lint-free cloth. If the cloth is dampened with water, do not let water enter the relief valve or vent holes. This device should be tested by the manufacturer at a minimum of every five years. If grease or oil is visible or suspected to be present, DO NOT use the device, and do not attempt to clean or repair it. Have it serviced by qualified personnel. If any leakage of the oxygen cylinder is detected, turn the valve stem or handle clockwise until the cylinder valve is closed. If leakage persists, place the cylinder outdoors and notify the gas supplier immediately. 13 14

Warranty Your Resource v.2 is designed to work satisfactorily for many years. However, in the event the unit does not perform to its specifications, it is warranted under normal use against any and all manufacturing defects from date of purchase for a period of 2 years by the manufacturer. Any failure resulting from defective parts or faulty workmanship, as determined during evaluation at a manufacturer-approved repair facility, will be repaired under warranty by the manufacturer. This warranty will be null and void for any unit that has been subjected to misuse, negligence, or repairs other than those performed by authorized service facilities. Manufactured for and Distributed by: Cramer Decker Medical, Inc. 4 Chrysler Irvine, CA 92618 Tel: 949.461.5930 www.cramerdeckermedical.com 15 BOOKLET PN: 460019