PRESENTED AT: NACE CORROSION 2006 SAN DIEGO, CA

Similar documents
PTRT 2470: Petroleum Data Management 3 - Facilities Test 4 (Spring 2017)

Optimizing Effective Absorption during Wet Natural Gas Dehydration by Tri Ethylene Glycol

DEHYDRATION OF ACID GAS PRIOR TO INJECTION Eugene W. Grynia, John J. Carroll, Peter J. Griffin, Gas Liquids Engineering, Calgary, Canada

Figure Vapor-liquid equilibrium for a binary mixture. The dashed lines show the equilibrium compositions.

PREPARING SOLUBILITY DATA FOR USE UPDATING KEY RESOURCES BY THE GAS PROCESSING INDUSTRY:

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

OIL AND GAS PROCESSES AND EMISSIONS

INNOVATIVE GAS-LIQUID SEPARATOR INCREASES GAS PRODUCTION IN THE NORTH SEA

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Chapter 13 Gases, Vapors, Liquids, and Solids

Natural Gas Desulfurization Process By MEA Amine: The preferable Engineering Design Procedure

GAS LIFT IN NEW FIELDS

INTEROFFICE MEMORANDUM MODIFICATIONS TO DEW POINT CONTROL PROCESS

Journal of Chemical and Pharmaceutical Research, 2016, 8(5): Research Article

DISTILLATION POINTS TO REMEMBER

Vapor Recovery from Condensate Storage Tanks Using Gas Ejector Technology Palash K. Saha 1 and Mahbubur Rahman 2

PE096: Overview of Gas Processing Technology

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

SHOP WELDED TANKS STANDARD CONNECTIONS

16. Studio ScaleChem Calculations

From the Choke KO drum, the gas passes through another gas/gas exchanger - the 'LTS Pre-cooler'.

Application Worksheet

EDUCTOR. principle of operation

Focus on VOC Emissions Reduction Using an Oxygen Based Inerting Control System For Inert Gas Blanketing of Chemical Process Vessels

Air Eliminators and Combination Air Eliminators Strainers

Removing nitrogen. Nitrogen rejection applications can be divided into two categories

1 PIPESYS Application

Natural Gas Gathering

CHEMOLUBE H SPECIAL FIRE RESISTANT HYDRAULIC FLUID

1. A pure substance has a specific volume of 0.08 L/mol at a pressure of 3 atm and 298 K. The substance is most likely:

OIL AND GAS SEPARATION DESIGN MANUAL

The Use of Radioactive Sources in Troubleshooting Gas Plant Problems. By Waleed J. Georgie PRIMAS (Oil & Gas) Consultancy, Aberdeen, Scotland

Protective Atmospheres, Measurement Technologies and Troubleshooting Tools

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Yutaek Seo. Subsea Engineering

Thermodynamics ERT 206 Properties of Pure Substance HANNA ILYANI ZULHAIMI

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

States of Matter Review

New 55 Holdings LLC. R3 Universal B&W Film Developer Material Safety Data Sheet

Gas Laws Chapter 14. Complete the following pressure conversion. Be sure to show how units cancel.

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Please do not write on this test. Please use the answer sheet. 1) Please choose all conditions that would allow a gas sample to behave ideally.

CHEM 3351 Physical Chemistry I, Fall 2017

Treatment plants for gas production

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT STORMY PHILLIPS J-W MEASUREMENT 9726 E. 42 ND STREET, STE. 229 TULSA, OK 74146

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

PRODUCTION EQUIPMENT EFFECTS ON ORIFICE MEASUREMENT. Stormy Phillips

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

Ch. 11 Mass transfer principles

--- III. itti A. on_ coo. & EP Department DOCUMENT NO: WOC-HSE-ST Section H005 Hydrates

Name Chemistry Pre-AP

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

TABLE OF CONTENT

COPYRIGHT. Reservoir Fluid Core. Single Phase, Single Component Systems. By the end of this lesson, you will be able to:

Laser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C

Natural Gas Conditioning Skids & Equipments

Fundamentals Of Petroleum Engineering PRODUCTION

Ingestion: - No special treatment is generally required. - Do not make the patient vomit to prevent risks of aspiration in the respiratory tract.

Original ATE DOT3 Brakefluid (blue)

Cost Effective Natural Gas Conditioning Twelve Years Experience of Membrane System Operation

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

maintaining storage tank dissolved oxygen levels utilizing gas transfer membranes

Bladder Tank Installation & System Design Information

SAFETY DATA SHEET. CALLOUS CUTTER Revision 01/30/ PRODUCT AND COMPANY IDENTIFICATION 2. HAZARDOUS IDENTIFICATION

Optimizing Gas Supply for Industrial Lasers

acrolein, acetaldehyde and acetone( cm -1 ); methanol (1306 cm -1 ); ethylene (949 cm -1 ); and isoprene (893 cm -1 ).

Safety Data Sheet Lyden Oil Company

Example: Calculate the density of methane at 50 psig and 32 ⁰F. H.W. In previous example calculate the density of methane in gm/m 3.

MATERIAL SAFETY DATA SHEET DATE PREPARED: January 2001

Generating Calibration Gas Standards

Simulation of Gas Dehydration Plants Safe Operation in Chemical Industry

At the end of this lesson, you will be able to do the following:

Using P-T Analysis As A Service Tool

Model Series 62 Constant Differential Relay

MODELLING OF REGENERATION IN TEG NATURAL GAS DEHYDRATION UNITS

Experiment 18 Properties of Gases

1 - IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

A Sub-Synchronous Vibration Problem: Trapped Fluid in Compressor Coupling Spacer. Diagnosis and Resolution

0B Glycol Dehydration as a Mass Transfer Rate Process. Nathan A. Hatcher, Jaime L. Nava & Ralph H. Weiland Optimized Gas Treating, Inc.

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Instructor s t Background

SAFETY DATA SHEET. Dura Seal Concrete Sealer. 1. Product and Company Identification. 2. Hazards Identification

Improving Performance of Gas Lift Compressors in Liquids-Rich Gas Service

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

Chem 110 General Principles of Chemistry

Safety Data Sheet. TB Quat

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

SAFETY DATA SHEET. Magnifico Lavender Fragranced All Purpose Cleaner. 1. Product and Company Identification. 2. Hazards Identification

Alkylphosphines. Storage and Handling Recommendations

Honors Chemistry - Problem Set Chapter 13 Classify each of these statements as always true, AT; sometimes true, ST; or never true, NT.

Quebec Quebec Tel : Fax : MSDS: Methane, Oxygen in Nitrogen Mixture PRODUCT INFORMATION

FlashCO2, CO2 at 23 $/ton

Safety Data Sheet 0307 LYNX RTU QUAT CLEANER DISINFECTANT. Additional ID:

Diagnosing EVAP systems By: Bernie Thompson

Phase Changes * OpenStax

Gilbert Kirss Foster. Chapter 10. Properties of Gases The Air We Breathe

SAFETY DATA SHEET. GHS Label Elements: The product does not require a hazard warning label in accordance with GHS criteria.

Transcription:

PRESENTED AT: NACE CORROSION 2006 SAN DIEGO, CA POSSIBLE GLYCOL CORROSION IN NOMINALLY DRY GAS PIPELINES John S. Smart, III John Smart Consulting Engineers Houston, TX 77079 Tel 281 493 5946 email jacksmartiii@hotmail.com Randy L. Roberts Brenntag/Coastal Chemical C. L.L.C. POB 81577, Lafayette, LA 70598-1577 Tel 337 261 0796 email rroberts@brenntag.com ABSTRACT Pipeline quality gas is normally dried in Triethylene Glycol to reduce its water dew point to below the lowest operating temperature in a pipeline, and the presence of glycol as a vapor in the gas has been regarded as insignificant. This paper explores how TEG vapor can exist in a pipeline in a similar manner to water, and possibly lead to corrosion. TEG vapor can condense at long distances down a gas pipeline as the line cools, with most condensing above 60 o F. However, even the small quantities involved accumulate with volume and time, and can become significant. The corrosion rate of steel in glycol is lower than for water and the problem is a long term one. In-Line Inspection for gas pipelines should pick up internal corrosion as well as external corrosion. Lines that are not piggable should be rinsed with a water/methanol slug driven by a foam disc pig to reduce risk when high risk areas such as low spots under rivers are present. Keywords: Glycol, Triethylene Glycol, glycol corrosion, dew point, gas pipeline internal corrosion, CONCLUSIONS AND RECOMMENDATIONS 1. Glycol used for dehydration of natural gas carries over as a vapor to gas pipelines and will condense to form a liquid that will remain in a pipeline until drained. 2. While the quantities of glycol are small per Million Standard Cubic Feet (MMSCF), high flow rates and long service periods will cause significant accumulations in pipelines which can cause corrosion.

3. Corrosion from glycol is insidious in that it will occur where it is not expected in conventional internal corrosion direct assessment models. 4. Corrosion from glycol is a long term problem as the rate of accumulation of glycol is low and corrosion rates are also low. 5. In Line Inspections (ILI) of gas pipelines should pick up any internal corrosion, but non-piggible lines should be rinsed with methanol/water slugs periodically to remove glycol and reduce risk of corrosion. INTRODUCTION Most gas plants dehydrate natural gas using a glycol such as Triethylene Glycol, and gas transmission companies recognize that there is water in their gas they receive. The level of water, however, is specified to be less than the dew point at the lowest ambient operating condition and there should not be any liquid water in their pipeline. Normal operation of a glycol dehydration plant has lean glycol entering the dehydration tower at about 100 o F and 97% glycol, near the limit of glycol regeneration due to the operating temperature of the glycol heater tubes. When the skin temperature of the glycol heater tubes is operated at above 405 o F, glycol thermally decomposes to produce acid byproducts such as HEED, especially if oxygen is present. The amount of water in natural gas is given in the McKetta and Wehe Chart, (1) which shows the amount of water, in pounds water/mmscf natural gas, as a function of temperature and pressure. This chart is extremely useful for determining to what level natural gas must be dried to avoid condensation of liquid water in a gas pipeline, the range of hydrate formation, and how much water will be condensed in such processes as gas compression interstage cooling. It also forms the basis for internal corrosion direct assessment and analysis of gas pipelines, as internal corrosion cannot occur without an electrolyte in a gas pipeline, and is still the most accurate data available for water in natural gas REVIEW OF GLYCOL CHEMISTRY AND USE IN GAS DRYING OPERATIONS Ethylene Glycols are straight chain aliphatic compounds terminated at each end by a hydroxyl group. Ethylene Glycol, diethylene glycol and triethylene glycol have one, two and three ethylene groups, respectively, with the ethylene groups in diethylene and triethylene glycol joined by an ether linkage. Ethylene Glycol Diethylene Glycol Triethylene Glycol HOCH 2 CH 2 OH HOCH 2 CH 2 OCH 2 CH 2 OH HOCH 2 CH 2 OCH 2 CH 2 OCH 2 CH 2 OH Ethylene glycol is manufactured by the hydration of ethylene oxide. Diethylene glycol and triethylene glycol are manufactured by reaction of ethylene glycol with ethylene oxide.

Glycols are characterized by their complete range of water solubility, affinity for water (hygroscopicity), moderate viscosity, freezing point depression of water, noncorrosiveness, high flash points and stability. Glycols have the physical properties shown in Table I. Table I Physical Properties of Pure Glycol Compounds Physical Property of Pure Compound Ethylene Glycol Diethylene Glycol Triethylene Glycol Boiling Point, 760 mmhg, o C 197.2 244.8 287.4 Flash Point, open cup, o C 240 290 330 Freezing Point, o C -13-10.5-7.2 Molecular Weight 62.7 106.12 150.17 Refractive Index 1.4318 1.4475 1.4559 Specific Gravity, 20/20 o C 1.1155 1.1184 1.1254 Specific Heat, 0 o C, cal/gm/ o C.544.551.525 Vapor Pressure, 20 o C, mm Hg 0.1 0.01 0.01 Viscosity, 20 o C, centipoises 20.9 35.7 47.8 Water Solubility Complete Complete Complete Weight, 20 o C, pounds/gallon 9.28 9.31 9.36 Glycols are used in automobile engine antifreeze/coolants, the manufacture of polyester fibers and films, the dehydration of natural gas, hydrate preventative, and various other uses of their hygroscopicity such as conditioning agents in adhesives, cork, tobacco, cellophane, vinyl floor tiles, synthetic rubber, cellulose sponges, printing inks and paper. It is also used as a deicer for airplanes due to its compatibility with steel, aluminum, magnesium, cadmium, natural and synthetic rubber, paint, copper and copper alloys, and acrylic plastic. GLYCOL DEHYDRATION OF NATURAL GAS Most pipeline gas is dried using triethylene glycol to a nominal value such as 6 pounds/mmscf. The vapor pressure of water in the temperature range of interest is shown in Figure 1. The McKetta and Wehe chart (1) can be calculated from the vapor pressure of water and the temperature of the natural gas system, with water contributing vapor volume according to its vapor pressure, with the McKetta and Wehe Chart also accounting for non-idealities in the gas. For instance, at 60 o F, the vapor pressure of water is 13.250 mm Hg. at 60 o F and 1 atm. pressure, corresponding to 0.2562 psi. The mole ratio of water to natural gas is then 0.2562/14.696 = 0.017434. Multiply this ratio by the number of moles in 1 MMSCF, 2638.522, and the molecular weight of water, 18.016, to get the weight of water in 1 MMSCF natural gas at 1 atm. absolute, 828.736 pounds per MMSCF.

The Vapor Pressure of Water vs. Temperature Vapor Pressure of Water, psi 2 1.5 1 0.5 0 0 50 100 150 Temperature, Deg. F Figure 1 The Vapor Pressure of Water vs. Temperature Similarly, a chart to show the amount of glycol vapor in natural gas can be calculated knowing the vapor pressure and molecular weight of glycol. The vapor pressures of mono-ethylene, di-ethylene and tri-ethylene glycols is given in the GPSA Engineering data book (1) using data supplied by Dow, and in other publications such as Ethylene Glycol, Diethylene Glycol, Triethylene Glycol (2) from Huntsman Corporation. Glycols used in dehydration are not pure, but are typically about 97% glycol after regeneration. The total vapor pressure of a glycol solution is a function of how much water it contains, but the vapor pressure of the glycol itself is approximated by the vapor pressure of the pure compound. The vapor pressure of pure TEG and its water solutions can be calculated using the Antoine Equation with the following constants: (2) Log 10 (P) mmhg = A B/(T o C +C) Equation 1

Table II Antoine Equation Constants for TEG Solutions at Various Temperatures TEG, Wt% A B C 0 7.959199 1663.545 227.575 50 7.922294 1671.501 228.031 70 7.878546 1681.363 228.237 80 7.837076 1697.006 228.769 90 7.726126 1728.047 229.823 95 7.620215 1806.257 236.227 97 7.495349 1841.522 238.048 98 7.404435 1881.474 240.666 99 7.211145 1926.114 242.799 99.5 7.042989 1970.802 242.864 100 7.472115 2022.898 152.573 Where the values of the constants are given in Table II for TEG solutions from 0 to 100% TEG: Figure 2 shows the TEG content of natural gas in pounds TEG/MMSCF for the temperature range from 30 o F to150 o F and from 600 psig to 1400 psig. Note that the vertical scale is logarithmic. Figure 2 is the equivalent of the McKetta and Wehe Chart for TEG. Similar charts can be made for MEG and DEG. It is recommended that the vapor pressure be calculated from the Antoine Equation rather than try to interpret Figure 2. Contact the authors for a spreadsheet on calculation of these curves. The procedure to calculate the amount of glycol in natural gas in pounds/mmscf is given in an example in this paper. At the usual rich glycol dehydration unit operating temperature of 100 o F in a glycol dehydration plant, the corresponding vapor pressure of triethylene glycol is 0.0007 psi, which is small but not zero. In a gas stream at a pressure of 1000 psi, the glycol vapor ratio would be equal to.0007/1014.696 or 1.3E-08. Multiplying this by the number of lb-moles in 1 MMSCF, 2638.5, there are 0.000035 moles triethylene glycol vapor in the gas per million standard cubic feet. The molecular weight of tri-ethylene glycol is 150.17, so there are 0.0053 pounds glycol/mmscf. Again, while this is a small number, it is not zero, and with enough gas production through a glycol dehydration plant, vapor carryover to the pipeline system could cause glycol condensation in the pipeline as the gas cools. Therefore, for corrosion analysis in a nominally dry gas pipeline, one must take into account and deal with the possible presence of glycol and cannot simply assume that low water dew point gas will always produce a corrosion free environment.

TEG Content of Natural Gas vs. Temperature and Pressure Log (TEG Content), lbs/mmscf 0 0 50 100 150 200-1 -2-3 600 psi 800 psi 1000 psi -4 1400 psi -5-6 Temperature, Deg. F Figure 2 Triethylene Glycol Content of Natural Gas vs. Temperature OPERATION OF GLYCOL DEHYDRATION UNITS TO MINIMIZE GLYCOL LOSSES Good operation of glycol dehydration systems has always involved minimizing glycol losses (5,6,7). Loss control begins with an adequate inlet gas scrubber design distinct from the integral contact tower scrubber. Inlet scrubber designs should handle approximately 125% of maximum gas flow rate and be equipped with a high liquid level shutdown. Entrained and free water, turbine and compressor oils, dissolved brine, downhole additives, and corrosion inhibitors are a few inlet gas contaminates that can cause excess losses of TEG. Some operational conditions, such as low lean return temperatures; low ph, increased hydrocarbon contamination, elevated iron and solids can all exacerbate foaming conditions and escalate glycol losses. The contact tower requires installation of an adequately sized wire-mesh mist extractor above the top tray to control glycol losses. An improperly sized mist extractor can cause glycol carryover at low gas flow rates. The mesh pad sizing K factor is usually 0.3 to 0.35 with the absorber tower sizing K no larger than 0.2. (5) The ratio of K s averages indicated that the pad should be approximately 75% of the vessel diameter (6).

Elevated lean glycol inlet temperatures, above 120ºF, can cause higher vaporization losses of TEG. The rule of thumb is 10ºF hotter than the inlet gas temperature to minimize hydrocarbons from condensing in the glycol and promoting stabilized foaming conditions. Triethylene glycol and all glycols naturally become acidic in the presence of CO2, H2S, COS, and O2. Careful monitoring of the ph will also minimize glycol carryover. Normal operating ph range is 7.0 to 8.3 (7). The following normal glycol losses will help to determine if you have a concern (6). Conditions are based on 1000 PSIG at 100ºF inlet gas. Absorber (mist): 0.10 gallon/mmscf Absorber (vapor): 0.01 gallon/mmscf Still Column with reflux coil (vapor): 0.02 gallon/mmscf Total Anticipated Loss: 0.13 gallon/mmscf or 1.2 lbs. MMscf Density of TEG = 9.35 lbs./gallon @ 77 º F. While these losses have been well known, only the vapor phase carry-over into the pipeline is able to be transported long distances down a pipeline, as mist carryover normally settles out in the first mile or less. PROBLEMS CAUSED BY GLYCOL Several things make glycol condensation a potential problem in gas pipelines: 1. Pipelines transport many million SCF gas, and in a heating season, many gallons of glycol can accumulate in the pipeline. 2. Glycol adsorbs water out of the gas to increase its volume and decrease its concentration. 3. Glycol condensation may produce an electrolyte in places where it is not expected and assumed not present, 4. Glycol cannot be dried from pipelines by flushing with very dry gas nor removal by conventional pigging. 5. An additional partially oxidized hydrocarbon nutrient source is available that could possibly be used by bacteria (4) and rendered corrosive; PRECIPITATION OF GLYCOL IN A GAS PIPELINE Liquid glycol carries over into a gas pipeline due to incomplete mist extraction in a glycol plant, typically at a rate of 0.1 gallon per MMSCF. If there is foaming in the plant, up to 0.5 gallons TEG per MMSCF may carry over. Thus, 95% or more of the glycol entering the gas pipeline will be liquid, and 5% or less will be vapor. Liquid glycol

carryover settles out quickly, typically within the first mile or less, and is usually recovered and recycled in a liquid trap or removed in a subsequent compressor suction scrubber. Vapor phase glycol, however, will only condense as the gas cools, and/or is compressed, and can carry down a gas pipeline for a long distance, right to the end if the line keeps cooling. To illustrate how much glycol can carry down a pipeline, and how far it goes, consider the fate of TEG in the following hypothetical case: 1. 200 MMSCFD Gas exits a glycol dehydration plant at 800 psi and 100 o F with 6 pounds water/mmscf, 2. The gas goes 1 mile to a gas compression facility, arriving at 790 psi and 90 o F 3. Gas is compressed to 1400 psi and cooled to 120 o F 4. Gas travels 200 miles to next compression station, arriving at 800 psi and 65 o F. 5. Gas is compressed to1400 psi and cooled to 120 o F 6. Gas travels 200 miles and arrives at second compressor station at 800 psi and 55 o F 7. Gas is compressed to 1400 psi and cooled to 120 o F 8. Gas travels 200 miles and arrives at third compressor station at 800 psi and 50 o F. Analysis Step 1: The vapor pressure of TEG at 100 o F, using the Antoine Equation, is 1.353 E-05 psi. The mole fraction of TEG in the gas at 800 psig is 1.353 E - 05/(814.696) = 1.661 E-08, and there are 2.494 E-06 moles TEG/MMSCF, or 0.006880 pounds TEG/MMSCF Step2 The gas is assumed to cool to 90 o F and have a 10 psi pressure drop in the first mile. The vapor pressure of TEG at 90 o F is 6.483 E-06, the mole fraction of TEG in the vapor at 790 psig is 6.107 E-09, and there are 0.003192 pounds TEG vapor in the gas as it arrives at the compressor station. The difference in TEG vapor content, from 0.006880 pounds glycol/mmscf down to 0.003192 pounds glycol/mmscf has condensed to liquid form by the time the gas reaches the compressor station and ideally is removed in the compressor knock-out vessel. At 0.003688 pounds/mmscf, this is over half the original glycol vapor content leaving the dehydration contactor. NOTE: In actual glycol contactors, demisters will still pass up to 0.1 0.3gallons/MMSCF liquids in the form of a fine mist. Step 3 Gas compression to 1200 psi, followed by cooling to 100 o F. Just like the behavior of water in gas, TEG will become undersaturated in the gas as the temperature is raised. For instance, the solubility of TEG in natural gas at 1200 psi is given in Figure 3, below, with the glycol content at 100 o F equal to.004413 lbs/mmscf. Since the gas entering the

compressor contains only.003192 pounds TEG in the compressed gas, no condensation occurs. The hot compressed gas is always undersaturated in glycol. Water in the gas, at 6 lbs/mmscf, will not condense either, as the saturation level of water in gas at 1200 psi and 100 o F is 8 lbs/mmscf. Step 4 Gas travels 200 miles to next compressor station, arriving at 800 psi and 65 o F. The gas here is at the same pressure as when it approached the compressor in stage 2, but is 25 o F lower in temperature. The glycol content of the gas entering this line segment is natural gas between 100 o F and 65 o F at 800 psi is as follows: Temperature Glycol Content of Gas, lbs/mmscf at 800 psi 100 o F (37.8 o C).006580 90 o F (32.2 o C).003153 80 o F (26.7 o C).001443 70 o F (21.1 o C).000629 65 o F (18.3 o C).000407 The difference in glycol content from the compressor discharge gas, 0.003192 pounds/mmscf and the amount soluble in the gas at 800 psi and 65 o F of.000407 lbs/mmscf is 0.002785 pounds/mmscf. This amount of TEG will condense somewhere in the pipeline as the gas cools below its TEG dew point, in this case, about 95 o F at 1200 psi. The TEG may condense as a fog and continue to be carried down the line, or it may condense on the wall of the pipe and settle to the bottom of the line. For a line carrying 200MMSCFD, the amount of TEG which condenses in this section of the line is 0.5578 pounds per day. For one year of operation, however, the amount is 203.6 pounds per year, or 21.75 gallons TEG. After ten or twenty years, the amount would be 217 gallons or 435 gallons. This is a significant amount of electrolyte in a pipeline where none is expected based on water dew point of the gas. In actual gas pipeline systems, the gas will cool to below its TEG dew point before indicated in the example, since the TEG dewpoint is higher at higher temperatures. For instance, the TEG dew points for the gas with 0.003192 lbs TEG/MMSCF used in this example are the following: Pressure, psig Dew Point Temperature 1200 95 o F 1000 93 o F 800 90 o F

Thus, gas with 0.003192 lbs TEG/MMSCF at 1200 psi will begin to condense TEG at 95 o F, gas at 1000 psig will condense TEG at 93 o F, and gas at 800 psig will begin to condense glycol at 90 o F. It is likely that the gas will cool more quickly than it will be reduced in pressure, so most of the pipeline will operate below the TEG dewpoint. This is beneficial for corrosion control since only small amounts of electrolyte will exist at any point in the pipeline unless there is rapid cooling at some location such as in cold water or under a cold river. Step 5 Gas is compressed to1200 psi and cooled to 120 o F. This is the same as step except that the compressor after cooler is not as effective. The glycol content of the gas remains the same as when the gas entered the compressor, i.e. at 0.000407 pounds/mmscf. No TEG or water condensation will occur until the TEG dew point is reached, approximately 65 o F depending on the pressure. Step 6 Step 7 Step 8 Gas travels 200 miles and arrives at second compressor station at 800 psi and 55 o F (12.8 o C). The TEG content of the gas is now down to 0.000163 pounds/mmscf, with the balance having condensed in the pipeline (under ideal conditions). The amount of TEG condensed in the pipeline is (0.000407 0.000163 lbs/mmscf) = 0.000244 lbs/mmscf, equivalent to 0.0488 pounds per day, or 17.8 pounds per year (<2 gallons). Gas is compressed to 1200 psi and cooled to 120 o F This is equivalent to Step 3, and no condensation occurs. Gas travels 200 miles and arrives at third compressor station at 800 psi and 50 o F. As in step 6, the gas will not condense additional TEG until it reaches the TEG dew point, but the dew point may be higher than the 55 o F temperature at the in let to the compressor station. The following table gives the TEG dew point temperature of a natural gas with 0.000163 pounds TEG/MMSCF: Pressure, psig 0.000163# Dew Point Temperature 1200 59 o F 1000 57.5 o F 800 55 o F As the gas cools to 50 o F at 800psig, the TEG vapor content is reduced to 0.000101 lbs/mmscf. The amount of TEG vapor condensation is (0.000163-0.000101 = ) 0.000062 pounds/mmscf under ideal conditions. This corresponds to 0.0124 pounds per day for 200MMSCFD, or 4.5 pounds glycol per year. A greater amount of glycol can actually condense if the line cools to 50 o F while the pressure is above 800 psi. If the gas cools to 50 o F at 1100 psi, the

TEG vapor content of the gas is only 0.0000735 lbs/mmscf, so an additional 0.000037 lbs TEG/MMSCF would condense in the beginning of the pipeline segment, resulting in 7.20 pounds condensed TEG per year. ESTIMATING THE CONCENTRATION OF GLYCOL IN CONTACT WITH WATER CONTAINING GASES Water vapor dew points over TEG solutions are presented in glycol references. (1,2), and the data for TEG is presented below in Figure 3 below. Figure 3 TEG-water solutions in Natural Gas (Ref. 2) For the case of 6 pound gas at 1000 psi, as used in the example, the dew point of the gas is 29 o F. The glycol in contact with this gas will have a

concentration as given in Table III below, as taken from Figure 3. Thus, the concentration of TEG in condensed liquid in the pipeline will be usually greater than 90% over the practical range of interest. Table III Composition of TEG in equilibrium with gas containing water Temp, o F 800 psi 1000 psi 1200 psi Dew point of 25 o F 29 o F 31 o F 6# gas, o F 100 o F 97.5 % 97.1% 97.0 % 90 o F 96.9 % 96.2% 96.0 % 80 o F 95.8 % 95.5% 95.3 % 70 o F 95.2 % 94% 93 % 60 o F 92 % 90.5% <90 % 50 o F <90 % <90% <90 % CORROSION IN GLYCOL Glycol acts as an electrolyte, and can cause corrosion, but at a lower rate than pure water. Van Bodegam et al. (4) have presented information on the corrosion rate of steel in glycol solutions with carbon dioxide in the gas, shown in Figure 5 as a fraction of the corrosion rate from carbon dioxide in brine. For the range of interest in gas pipelines, with 90-99+% TEG, the corrosion rate will be approximately 1% as much as in brine. However, this chart may not reflect low ph from thermal degradation of glycol nor from bacterial degradation of the glycol to produce acids. Industry experience is that most glycol dehydration plants are not well monitored for glycol ph and it is not uncommon to have the glycol ph as low as 3.5.

Figure 5 Effect of Glycol on CO 2 Corrosion of Carbon Steel, (Ref. 4) TREATMENT OF GAS PIPELINES TO PREVENT GLYCOL CORROSION Pigging with Methanol Many operators are aware of the presence of glycol in their lines, especially near to their dehydration plants, and run a slug of methanol and/or water to dissolve the glycol and pig it out of their pipeline. This is an effective treatment, and it should be recognized that running a pig without a methanol slug will merely smear the glycol on the wall of the pipe. In older pipelines, running an In Line Inspection pig is recommended to detect any corrosion that has occurred, even in lines nominally dry. Running an ILI pig in dry gas pipelines is normally done for external corrosion, but the pig should be able to differentiate between internal and external corrosion. Finally, internal corrosion direct assessment methods at present are designed around the water dew point. The possibility of internal corrosion from glycol needs to be recognized in direct assessment methods and checks made based on TEG collecting in, for example, low spots in the line. Lines which have inaccessible low spots and which may have glycol

accumulations, running a slug of methanol/water pushed by a foam sphere pig is recommended to clean the system and reduce risk. TEG AS A POSSIBLE BACTERIAL NUTRIENT Ray, Little and Jones-Meehan (3) have reported on the biodegradability of glycol/water mixtures. Glycols are readily biodegradable under some circumstances, including fresh and saltwater, ground water and soil inocula. Both aerobic and anaerobic degradation have been reported. Normally, glycol is a low corrosive media with a ph above 7. However, glycols can become corrosive due to either thermal breakdown or bacterial alteration. Several strains of bacteria are capable of using ethylene glycol and propylene glycol as sole sources of carbon. However, concentrations above 10% have toxic effects on yeasts and fungi from soil, but not necessarily on glycol utilizing bacteria. Since the equilibrium concentration of TEG with 6# gas is 90% or higher, then bacterial degradation of TEG is not expected in the pipeline. DISCUSSION TEG used in natural gas dehydration can travel long distances down natural gas pipelines and condense as the pipeline cools. While the quantities of glycol are not large, accumulation over years of operation can result in significant quantities of electrolyte at places not expected by analysis for water. Glycol is also a lower corrosion rate liquid than water. This combination will most likely only result in corrosion failures after many years, but gas pipelines already exist that have been in operation for more than 50 years and are expected to continue to operate. To remove glycol corrosion from a pipeline, pigging with slugs of methanol or water are required, as pipeline gas will nearly always be saturated in glycol vapor and cannot be removed by drying as would be liquid water. Removal by pigging without methanol or water would only smear the glycol on the wall of the pipe and not remove it from the pipeline. This would be especially important in high risk areas such as under rivers in non-piggable pipelines in an effort to minimize risk. The possible presence of liquid glycol in an otherwise dry natural gas pipeline is another good argument to run intelligent pigs for the entire length of piggable pipelines in addition to external corrosion. The suggested 5 year pigging interval is suitable to glycol corrosion due to its low corrosion rate.

REFERENCES 1. Gas Processor Suppliers Association Engineering Data Book, Ninth Edition 1972 Chapter 15, Dehydration and Treating 2. Ethylene Glycol, Diethylene Glycol, Triethylene Glycol Huntsman Corporation, Houston, TX 77056 1995 3. Richard L. Ray, Brenda J. Little and Joanne Jones-Meehan An Evaluation of Microbiologically Influenced Corrosion in Potential Fluids for Between-Hull Spaces NACE CORROSION 2002 Paper 02435 4. L. van Bodegom, K. van Gelder, M.K.F. Paksa, and L van Raam Effect of Glycol and Methanol on CO 2 Corrosion of Carbon Steel CORROSION87 Paper 55 NACE, Houston, TX 5. Manning, Francis S. Ph.D., P.E. & William P. Ph.D., P.E. Dehydration Using TEG PennWell Publishing Co. 1988, page 7; 6. Kendell, Wendell W., Matthew Hall Engineering, Inc., Design and Operate Glycol Units To Save Money, PetroEnergy 1984 Workshop 7. Ballard, Don, Coastal Chemical Co., L.L.C. How to Improve Glycol Dehydration page 11