Customer Responsibilities

Similar documents
Customer Responsibilities

Customer Responsibilities

490 Micro GC Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

490 Micro GC Site Preparation Checklist

Customer Responsibilities

Customer Responsibilities

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

DD2 Site Preparation Checklist Hardware Site Preparation Specification

Customer Responsibilities. Important Customer Information. Agilent Infinity II Preparative HPLC System Site Preparation Checklist

For additional information about our solutions, please visit our web site at US/Pages/HomePage.

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

6890 GC Site Preparation

Xcalibur, Gemini. User Manual. [Instrument version from September 2013 onwards] X-ray Diffractometer Systems. Version 2.

Columbus Instruments

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

Avio 500 ICP-OES. ICP-Optical Emission Spectroscopy PREPARING YOUR LAB. Preparation Checklist. Suitable Working Area

AB SCIEX QTRAP 4500 System

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

UltraLo 1800 Alpha Particle Counter

NGN Series nitrogen generator

TECHNICAL SPECIFICATION. SPC-1 Stirling Process Cryogenerator

Series Environmental Chambers

TECHNICAL SPECIFICATION. SPC-4 Stirling Process Cryogenerator

Preparing Your Laboratory for the Optima 7300 V and 8300 ICP-OES Spectrometers

Varian 240-MS GC/MS Ion Trap Mass Spectrometer Pre-installation Instructions

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

APEX TM III MASS SPECTROMETER SITE GUIDE AND PRE-INSTALLATION INSTRUCTIONS

Your local gas generation partner. Precision series Modular gas generation solution for GC.

PRC CO ² -LASER PRESENTATION

Discovery TGA 55, TGA 550, TGA Site Preparation Guide

Miris Ultrasonic Processor

Customer Responsibilities. Important Customer Information GCMS QQQ Site Preparation Checklist

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Nitrogen Supply System

Pneumatic spool valve islands

SonoMeter 30 Energy Meters

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

GasSense NDIR User Manual

User Manual. Quantos Automated Dosing Liquid Module

Technical Information

CNG FILLING STATIONS

Pressure Automated Calibration Equipment

Varian 400-MR Magnetic Resonance Spectrometer Pre-installation Instructions

Workhorse-15 Oxygen Generator

NexION 1000/2000 ICP-MS

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 5975C MSD Series G3170A, G3171A, G3172A, G3174A

Pneumatic valve islands

RPS900W Redundant Power Supply. Installation Guide.

Discovery HP-TGA 75/750. Site Preparation Guide

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Cryostream 800 Series

Recirculating Coolers

Oxford Instruments Plasma Technology

TA Instruments Installation Requirements for the Thermal Discovery Series

Additel 780 Series Pressure Controller

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

Please refer to the Hydrogen Safety Guide which is shipped with the Instrument. 5977B Series GC/MS Systems Site Preparation Checklist

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Budget Range Operators Handbook

Your local gas generation partner. Precision series Modular gas generation solution for GC.

PURCHASE AND DELIVERY OF A HELIUM CLOSED-CYCLE OPTICAL CRYOSTAT. The present tender is only an unofficial translation provided as a courtesy.

HumiSys HF High Flow RH Generator

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

High Pressure Breathing Air Compressors

New AQF Filter Polymer Filtration System

icon i150 / i350 Installation / Operation Manual

Your local gas generation partner. Precision series Modular gas generation solution for GC.

TECHNICAL INFORMATION

Step-by-Step Planning Guide

Preinstallation Checklist and Instructions for the TriStar These Preinstallation Checklist and Instructions were reviewed and approved by:

Agilent 7890 / 220 Ion Trap GCMS Site Preparation Checklist

To plot the following performance characteristics; A pump is a device, which lifts water from a lower level to a higher

Electro-Pneumatic Converter YT-940 SERIES

icap Q Preinstallation Requirements Guide

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

NGP-250/500 Nitrogen Generator Quick Start Guide

Additel 780 Series Pressure Controller

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Gas Hydraulic Valve Operator

CCT-7320/ROC-2313 Reverse Osmosis Controller

CAPITAL CONTROLS SERIES NXT3000

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

THE WATER-COOLED INDUSTRIAL RANGE

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Operating Instructions

Digital Melting Point Apparatus

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Best Practice Guide, Servomex 2700

Transcription:

Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is the key first step in ensuring that your instruments and software systems operate reliably over an extended lifetime. This document is an information guide AND checklist prepared for you that outlines the supplies, consumables, space and utility requirements for your equipment for your site. Customer Responsibilities Make sure your site meets the following prior specifications before the installation date. For details, see specific sections within this checklist, including: Guidance When completing the relevant checkboxes in the checklist using a X or tick mark, please note that "X" stands for FAIL and for PASS. The site meets the requirements for Instrument space dimensions, floor loading and door access as describe in the Section 1 - Dimensions and Weights below. The Laboratory where the instrument will be located meets the environmental conditions for Temperature and water requirements as described in Section 2 Environmental Conditions The Power in the Laboratory meets the requirements for location, voltage/ current rating and number of socket outlets as described in Section 3 Power consumption Additional item to be made available by the customer at the time of installation including a suitable high vacuum pump, ideally 70 Liters/sec turbo molecular pump, water to the correct specification and Liquid Nitrogen or Helium to the correct purity as described in Section4 - Additional requirements to be supplied by the customer. An Uncompensated Geiger Muller tube radiation monitor should be available to carry out a critical examination of the equipment. Please consult Other Requirements section below for other product-specific information. For more details, please consult the product-specific Site Preparation. If Agilent is delivering installation and familiarization services, users of the instrument should be present throughout these services; otherwise, they will miss important operational, maintenance and safety information. 1 Page 1 of 8

Important Customer Information 1. If you have questions or problems in providing anything described as a Customer Responsibilities above, please contact your local Agilent or partner support/service organization for assistance prior to delivery. In addition, Agilent and/or its partners reserve the right to reschedule the installation dependent upon the readiness of your laboratory. 2. Should your site not be ready for whatever reasons, please contact Agilent as soon as possible to re-arrange any services that have been purchased. 3. Other optional services such as additional training, operational qualification (OQ) and consultation for user-specific applications may also be provided at the time of installation when ordered with the system, but should be contracted separately. Important Customer Web Links How to get information on your product? - http://www.agilent.com/chem/xrd Need to know more? - customer Education http://www.agilent.com/chem/education NOTE: Please use your local call centers when contacting us for any Sales & Service related questions quoting your system type and serial number. If your country does not appear below please contact xrdsupport@agilent.com Site Preparation Completion Date completed Customer signature 2 Page 2 of 8

Dimensions and Weight Identify the laboratory space before your system arrives based on the table below. Pay special attention to the total height and total weight requirements for all system components you have ordered. Also pay special attention to the total weight of the modules you have ordered to ensure your laboratory floor can support this weight. 1. Floor should be able to bear the system weight of about 500kg over an area of 0.64m2. 2. Floor should be flat and horizontal within a tolerance of 3mm. 4. 3. Doorways to the room for installation are at least 85 cm wide. 5. Allow at least 63 cm clearance between Diffractometer and wall. 6. Adequate space is required around the system for servicing. The minimum clearance from the walls and a suggested system layout are shown in Fig.1 drawing. 7. When the low temperature option is fitted an extra 100 cm space on the left-hand side of the system is required. 8. An engine hoist or several people should be available to help with assembly. 9. Tables should be provided for temperature controllers if ordered. Instrument Description Weight Height Depth Width Kg lbs cm in cm in cm in Kappa Goniometer 106 234 64 25 47 19 43 17 X-Ray generator 40 88 22 9 69 27 48 19 Enclosure 50 110 100 39 100 40 115 45 Electronics rack 80 176 85 33 80 31 80 31 KMW200b 19 42 10 4 37 15 60 24 KMW300C 56 124 54 21 96 38 38 15 Option devices Weight Height Depth Width Kg lbs cm in cm in cm in Helijet Head 10 22 25 10 10 4 30 12 Helijet transfer line 3 7 150 60 6 2,5 250 99 Cryojet Head 15 33 35 14 15 6 15 6 3 Page 3 of 8

ILM210 5 11 10 4 30 12 44 17 ITC502 5 11 10 4 30 12 44 17 GFC1 12 27 26 10 38 15 45 18 Approximate Boxed Weights Weight Height Depth Width Kg lbs cm in cm in cm in Goniometer 165 364 90 35 95 37 60 24 Protection cabinet 195 430 60 24 140 55 120 47 Electronics rack 185 408 105 41 95 37 95 37 CCD camera 135 298 115 45 115 45 95 37 Accessories 177 390 90 35 120 47 80 31 KMW3000C Chiller 100 220 80 31 110 43 50 20 X-ray Tubes 40 88 60 24 50 20 50 20 Option devices Weight Height Depth Width Kg Lbs cm In cm In cm In 160L LN2 Dewar 120 265 155 61 70 28 70 28 Cryojet 145 320 190 75 70 28 80 31 Helijet 105 231 100 40 95 37 60 24 Helijet, Transfer Tube 20 44 15 6 170 67 95 37 60L LHe Dewar 100 220 145 57 70 28 70 28 4 Page 4 of 8

Fig.1 Gemini Suggested Layout 5 Page 5 of 8

Environmental Conditions Operating your instrument within the recommended temperature ranges insures optimum instrument performance and lifetime. 1. Performance can be affected by sources of heat & cold e.g. direct sunlight, heating/cooling from air conditioning outlets, drafts and/or vibrations. 2. The site s ambient temperature conditions must be stable for optimum performance. 3. The Relative Humidity is particularly important as the CCD and its cooling pipes can reach ~12 C, condensation should not be allowed to collect on the CCD at any time. 4. Clean location, dust free environment > 2m from air conditioning or heating units Instrument Description Operating temp range C (F) Gemini/Xcalibur (Operating conditions) 18-28 (64-82) Operating humidity range (%) 20-80 without condensation Heat Dissipation (BTU) 6800 Instrument Description Storage temp range C (F) Gemini / Xcalibur (Storage conditions) 10-40 (50-104) Tap water or closed loop supply line Storage humidity range (%) 20-80 without condensation Heat Dissipation (BTU) None 1. This is only required if the Gemini/Xcalibur is not to be used with the third party chiller. 2. Take care to check Return Line Pressure on closed loop water systems Min flow rate 3.3 l/min Supply Line Pressure 3 5 bar gauge Return Line Pressure Maximum of 1 Bar Temperature stability Temperature range ± 5 C 10 20 C Composition Filtered, without deposits, chemically neutral and optically clear 6 Page 6 of 8

Note: Gravity drain with an elevation that does not exceed 1 m should be available only when tap water used. If the external cooling water for the Xcalibur/Gemini system is to be supplied by a third party chiller, this circuit should incorporate its own bypass valve system as the Xcalibur/Gemini Chiller will only take water as and when it is required. The third party chiller supply pressure must be set to 3 bar. Power Consumption 1. Connectors suitable for the mains outlets must be available when the Agilent Technologies service engineer arrives to carry out the installation. (If local rules require it an Electrician may have to be arranged by the customer to make the connections). 2. Outlets location should be on wall behind the system, (except Computer Monitor supply which should be near intended computer location). 3. Common Earth should be supplied for all connections <0.5 Ohm. 4. Circuit breaker should be fitted to all outlets. 5. In areas where the mains power supply is unreliable an uninterruptible power supply (UPS) is recommended. The UPS should have specifications of 10 kva with 3-phase input and single phase output. 6. Fit a line voltage regulator if the power supply voltage fluctuates more than ±10 %. Instrument Description Line Voltage (V) Frequency (Hz) Fuse Rating (A) Gemini system + peripherals 1 x single-phase outlet 50/60 Hz ±5% 1 x 16 Gemini high voltage power supply 2 x single-phase outlet 50/60 Hz ±5% 2 x 32 Xcalibur high voltage power supply 1 x single-phase outlet 50/60 Hz ±5% 1 x 32 PC monitor 1x single-phase outlet 50/60 Hz ±5% 1 x 16 Low Temperature Attachment 3 x single-phase outlet 50/60 Hz ±5% 1 x 16 7 Page 7 of 8

Required Operating Supplies by Customer 1. For information on Agilent consumables, accessories and laboratory operating supplies, please visit http://www.chem.agilent.com/en-us/products/consumables/pages/default.aspx 2. For all systems incorporating Cu Enhance Ultra Optics the customer should provide 1 full helium gas cylinder of at least 99.95% grade helium gas in order that the Ultra Optics can be demonstrated. 3. A turbo molecular pump, capacity 70 litres/sec is REQUIRED before each use of the Helijet, and must be supplied if not purchased as part of the system. Gas Options Purity Regulator Minimum pressure Flow rate Helijet, Ultra optics low pressure 0.5 bar gauge 30-40 cm3/min @ Helium 99.95% regulator ATP Liquid Options Purity Quantity Helium Helijet 99.99% 50L Nitrogen Nitrogen powered LTs Up to 75L Water KMW3000 Demineralized 35L Demineralized water specification 10 μs/cm < specific conductivity < 250 μs/cm 1 D < hardness in German Degrees < 4 D 7.5 <acidity (ph) < 9.5 In practice this can usually be achieved by using a mixture of demineralized water and filtered tap water. The ph can be modified by adding NaOH to the water whenever required. Whenever possible use old or boiled water rather than fresh tap water. For third party chiller water specification please follow the manufacturer manual. 8 Page 8 of 8