Guidelines on Monitoring in Anaesthesia

Similar documents
Recommendations on Checking Anaesthesia Delivery Systems

Recommended Minimum Facilities for Safe Anaesthetic Practice in Operating Suites

Recommendations for Standards. Monitoring. Cardiopulmonary Bypass

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Recommendations for the minimal monitoring of the patient during anaesthesia.

Recommendations for Standards of Monitoring and Alarms During Cardiopulmonary Bypass

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

Anaesthetic infrastructure and supplies

Monitoring, Ventilation & Capnography

Section 14: Equipment failure

Using the Lifebox oximeter in the neonatal unit. Tutorial 1 the basics

Mechanical Ventilation

VENTILATORS PURPOSE OBJECTIVES

RESPIRATORY PHYSIOLOGY, PHYSICS AND

Minimum equipment list for cardiopulmonary resuscitation Primary dental care

Mechanical Ventilation

McHENRY WESTERN LAKE COUNTY EMS SYSTEM FALL 2014 CONTINUING EDUCATION MANDATORY FOR ALL PRIMARY AND PROBATIONARY ALS SYSTEM PROVIDERS.

Location Publication / Responsible And Number. Controller Standards Australia

Recommendations. For Standards of. Monitoring and Safety during. Cardiopulmonary Bypass

Cardiac Arrest General

Proceedings of the World Small Animal Veterinary Association Sydney, Australia 2007

Page: 1 of 6 Responsible faculty: (Signature/Date)

QED-100 Clinical Brief

Breathing Circuits. Product training

Virginia Office of Emergency Medical Services Scope of Practice - Procedures for EMS Personnel

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

EMS INTER-FACILITY TRANSPORT WITH MECHANICAL VENTILATOR COURSE OBJECTIVES

Homecare Pneumology NEONATOLOGY ANAESTHESIA INTENSIVE CARE VENTILATION Step beyond the future

Flow meter. bellow vaporizer. APL valve. Scavenging system

Comparison Of The Efficacy Of Two Low Fresh Gas Flow Techniques In Low Flow Anaesthesia

Invasive mechanical ventilation:

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

o An experienced and trained assistant is available to help you with induction.

Medical Ventilators. Ryan Sanford Daniel Tajik

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

Isoflurane: Safe Use Guidelines. (2-chloro-2-(difluoromethoxy)-1,1,1- trifluoro-ethane) is a halogenated ether used for inhalational anesthesia.

Instructions/Procedure for Use of the Speaking Valve

Selecting and Connecting Breathing Systems

Sign up to receive ATOTW weekly -

Update on Thoracic Anesthesia: Perioperative Lung Protective Strategies in One- and Two-Lung Ventilation

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

Engineering World Health Youth EWH Design Projects That Matter

Nitrous oxide Quiz 2017 Answers

Chapter 9 Airway Respirations Metabolism Oxygen Requirements Respiratory Anatomy Respiratory Anatomy Respiratory Anatomy Diaphragm

Mechanical Ventilation

Frequently Asked Questions About AEDs updated 11/2/2015

4/2/2017. Sophisticated Modes of Mechanical Ventilation - When and How to Use Them. Case Study 1. Case Study 1. ph 7.17 PCO 2 55 PO 2 62 HCO 3

Historically, rebreathing anesthesia systems

Hartle et al. Checking anaesthetic equipment 2012 Anaesthesia 2012, 67, The pre-use check to ensure the correct functioning of anaesthetic equ

OXYGEN FOR ADULTS IN ACUTE CARE

Hospital and Transport for Controlled Breathing

Fingertip Pulse Oximeter

I. Subject: Medical Gas Systems Utility Failure Interim Procedure III. Purpose:

Certified Hyperbaric Specialist Application

GE Healthcare. Aestiva/5. More than superior ventilation

ROUTINE PREOXYGENATION

Medical Instruments in the Developing World

Nitrous Oxide Sedation

We Warm Animals. User Manual For. Darvall Heated Smooth-Wall Circuits. Darvall Heated ZDS Qubes

Standard Operating Procedure

Anesthesia monitoring

Quick Response Pneupac VR1 Emergency Ventilator AIRWAYMANAGEMENT

Equipment and supplies - pediatric intensive care service.

PROCEDURE (TASK): ROUTINE VENTILATOR CHECK. 5. Verifies current ventilator Insures correspondence between physician's

Respiratory Medicine. A-A Gradient & Alveolar Gas Equation Laboratory Diagnostics. Alveolar Gas Equation. See online here

Clinical Skills. Administering Oxygen

Essential Performance for MED rd ed. PSES San Diego chapter meeting December 11, 2012

Vital Signs Monitoring

Environmental Health & Safety

Let s talk about Capnography

New A7 Anesthesia Workstation

HOME OXYGEN THERAPY Why is oxygen important? Who benefits from home oxygen therapy?

INITIATE APPROPRIATE RESUSCITATION PER POLICY/PROTOCOL

Performance Redefined. Automatic Gas Control (AGC) FLOW-i Anesthesia Delivery System

ACUC ۰ ROUTINE PROCEDURE

Emergency Transport and Ventilation

Circulation and Respiration: Vital Signs Student Version

6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists. Course Test Results for the accreditation of the acquired knowledge

Keeping anaesthetic pollution to minimum in theatre environment

VIMA. (Volatile Induction and Maintenance Anesthesia) How and Why. James H. Philip M.E.(E), M.D.

WARNING: EXPLOSION HAZARD

PRACTICE GUIDELINE EM004 EMERGENCY CENTRE EQUIPMENT

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Auditing the non-emergency use of a fan or oxygen to relieve breathlessness at rest: Background form

Practical considerations in anaesthetising exotic species. By Keith Simpson BVSc MRCVS AMIIE(Electronics).

THE ANAESTHETIC MACHINE THE NEXT GENERATION

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Lab #2: Blood pressure and peripheral circulation

NOTE: If not used, provider must document reason(s) for deferring mechanical ventilation in a patient with an advanced airway

Day-to-day management of Tracheostomies & Laryngectomies

The right atmosphere for health. A system for medical gas supply

Anesthesia Machines. Inhaled Anesthetic Agents

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?


TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Learning objectives. First Response Learning Module 2 Based on ILCOR and ANZCOR 2016

D Beyond essentials DRÄGER SAVINA 300 SELECT

First Response Learning Module 2 Based on ILCOR and ANZCOR Victorian Newborn Resuscitation Project Updated March 2018

Transcription:

Page 1 of 8 Guidelines on Monitoring in Anaesthesia Version Effective Date 1 OCT 1992 2 FEB 2002 3 APR 2012 4 JUL 2013 5 MAY 2017 Document No. HKCA P1 v5 Prepared by College Guidelines Committee Endorsed by HKCA council Next Review Date 2022

Page 2 of 8 Table of Contents 1. Introduction 3 Page 2. Personnel 3 3. Clinical Monitoring of the Patient 4 4. Monitoring Equipment 5 5. Emergency Circumstances 8 6. Postanaesthetic Recovery 8 7. References 8

Page 3 of 8 1. INTRODUCTION 1.1 The Hong Kong College of Anaesthesiologists recommends the monitoring of certain fundamental physiological variables during anaesthesia. Clinical judgement will determine how long monitoring should be continued following completion of anaesthesia. 1.2 The following recommendations refer to patients undergoing general anaesthesia, major regional anaesthesia and monitored anaesthetic care (where relevant) for diagnostic or therapeutic procedures and should be interpreted in conjunction with other policy documents published by the Hong Kong College of Anaesthesiologists. 1.3 Some, or all, of these basic recommendations will need to be exceeded depending on the physical status of the patient, the type and complexity of the surgery to be performed, and the requirements of anaesthesia. 1.4 Monitoring must always be used in conjunction with careful clinical observation by the anaesthesiologist as there are circumstances in which equipment may not detect unfavourable clinical developments. 1.5 Visual and audible alarms must be appropriate and enabled at the commencement of anaesthesia by the anaesthesiologist. There may be exceptional circumstances where this may not be achievable (e.g. cardiopulmonary bypass surgery where the patient is rendered apnoeic and pulseless) but those alarms should be made operational as soon as practicable. 1.6 The health care facility, in which the procedure is being performed, is responsible for provision of equipment for anaesthesia and monitoring on the advice of one or more designated specialist anaesthesiologists, and for effective maintenance of this equipment. Equipment need to have been checked as safe before use on patients. 2. PERSONNEL 2.1 Clinical monitoring by a vigilant and diligent anaesthesiologist is the basis of patient care during anaesthesia. This should be supplemented by appropriate

Page 4 of 8 devices to assist the anaesthesiologist. 2.2 The person who monitors the patient must be a medical practitioner with appropriate training in anaesthesia whose sole responsibility is the provision of anaesthetic care for that patient. This person cannot be the practitioner performing the procedure. The person should be familiar with all the equipment he intends to use and has followed any specific checking procedures recommended by individual manufacturers. 2.3 The anaesthesiologist who monitors the patient must be constantly present from induction of anaesthesia until safe transfer to the post-anaesthetic care unit or intensive care unit has been accomplished. In exceptional circumstances, that person shall delegate, briefly, observation of the patient to an appropriately qualified person who is judged to be competent for the task. The primary anaesthesiologist should remain contactable by the relieving personnel and return instantly to patient if required. 2.4 The individual anaesthesiologist, being responsible for monitoring the patient, should ensure that appropriate monitoring equipment is available. Where there is an environmental risk to staff, e.g. radiation, adequate facilities must exist to enable remote patient monitoring. 3. CLINICAL MONITORING OF THE PATIENT 3.1 The clinical monitoring of a patient undergoing any type of anaesthesia should include regular assessment and recording of the following: 3.1.1 Circulation 3.1.1.1 The circulation must be monitored at frequent and clinically appropriate intervals by detection of the arterial pulse and measurement of the arterial blood pressure. 3.1.2 Ventilation 3.1.2.1 Ventilation must be monitored continuously by both direct and indirect means. A stethoscope should be available in every operating room and anaesthetizing location. 3.1.3 Oxygenation

Page 5 of 8 3.1.3.1 The patient must be observed at frequent intervals for evidence of central cyanosis. The displayed values of an oximeter must be interpreted in conjunction with observation of the patient. Adequate lighting must be available to aid with assessment. 4. MONITORING EQUIPMENT 4.1 In general, monitoring equipment aids the clinical assessment of a patient. Depending on the type of anaesthesia, some of these monitors are mandatory. 4.2 Minimal monitoring devices must be attached before induction of anaesthesia and their use continued until the patient has recovered from the effects of anaesthesia. During induction of anaesthesia in children and in uncooperative adults, it may not be feasible to attach all monitoring before induction. In these circumstances, monitoring must be attached as soon as possible and the reasons for delay recorded. 4.3 When the monitors are in use on a patient, the alarms (visual and audible) must be enabled and appropriate (refer section 1.5). The audible component of the alarm system must be able to be heard by the practitioner responsible for the anaesthesia. 4.4 When any of the monitors of physiological function are in use during anaesthesia, regular recordings should be documented in the anaesthesia record. Minimum monitoring data, for example, heart rate, blood pressure, peripheral oxygen saturation, end-tidal carbon dioxide and anaesthetic vapour concentration (if volatile anaesthetic agents or nitrous oxide are used) must be recorded at least every five minutes, and more frequently if the patient is clinically unstable. 4.5 The following equipment must be available for every patient under any type of anaesthesia: 4.5.1 Pulse Oximeter 4.5.1.1 Pulse Oximeter must be in use for every patient under anaesthesia or sedation. When this particular monitor is in use, the variable pulse tone as well as the low threshold alarm shall be appropriately set and audible to the practitioner responsible for the anaesthesia

Page 6 of 8 4.5.2 Electrocardiograph. 4.5.2.1 A 5-lead option should be available 4.5.3 Intermittent Non-invasive Blood Pressure Monitor 4.5.3.1 A variety of cuff sizes must be available. 4.6 The following equipment are mandatory for general anaesthesia: 4.6.1 Oxygen Supply Failure Alarm 4.6.1.1 An automatically activated device to monitor oxygen supply pressure and to warn of low pressure must be fitted to the anaesthetic machine. 4.6.2 Oxygen Analyzer/Monitor 4.6.2.1 A device incorporating an audible and visual signal to warn of low oxygen concentrations, correctly fitted in the breathing system, must be in continuous operation for every patient when an anaesthetic breathing system is in use. 4.6.3 Volatile Anaesthetic Agent Concentration Monitor 4.6.3.1 Equipment to monitor the concentration of inhaled anaesthetics must be in use for every patient undergoing general anaesthesia from an anaesthetic delivery system where volatile anaesthetic agents are available. Automatic agent identification should be available on newly acquired monitors. 4.6.4 Monitor for Ventilation and Alarms for Ventilation Failure 4.6.4.1 When an automatic ventilator is in use, airway pressure, tidal volume and respiratory rate must be monitored. A device capable of warning promptly of presence of high or continuous airway pressure, breathing system disconnection or ventilator failure must be in continuous operation. It is desirable that this device be automatically activated. 4.6.5 Carbon Dioxide Monitor 4.6.5.1 A monitor of the carbon dioxide level in inhaled and exhaled gases must be in use for every patient undergoing general anaesthesia or deep sedation, except in certain circumstances capnography monitoring is

Page 7 of 8 not feasible, for example during high frequency jet ventilation. 4.6.6 Monitor of Cuff Pressure of Airway Device 4.6.6.1 Cuff pressure of airway devices, for example, endotracheal tube and laryngeal mask, should be monitored regularly throughout the operation. 4.7 The following equipment could be useful in some circumstances: 4.7.1 Continuous Invasive Blood Pressure Monitor 4.7.1.1 Equipment to provide continuous invasive blood pressure monitoring should be available where appropriate. In most cases, this refers to a monitor connected via a transducer to an intra-arterial line. 4.7.2 Temperature Monitor 4.7.2.1 Equipment to monitor core temperature continuously must be applied for all patients undergoing general anaesthesia, in which the procedure lasts longer than 30 minutes. 4.7.3 Neuromuscular Function Monitor 4.7.3.1 Monitoring of neuromuscular function must be available for those patients in whom neuromuscular blockade has been induced and should be used whenever the anaesthetist is considering extubation following the use of non-depolarizing neuromuscular blockade. 4.7.4 Monitoring of anaesthetic effect on the brain 4.7.4.1 When clinically indicated, equipment to monitor the anaesthetic effect on the brain should be applied, especially for patients at high risk of awareness, for example, those under total intravenous anaesthesia with muscle relaxant used. 4.7.5 Other Equipment 4.7.5.1 When clinically indicated, equipment to monitor other physiological variables (e.g. the electroencephalogram, central venous pressure, trans-esophageal echocardiogram, cardiac output or respiratory mechanics) should be available.

Page 8 of 8 5. EMERGENCY CIRCUMSTANCES 5.1 Immediate life support measures are the first priority in emergency circumstances. Appropriate monitoring as described in these recommendations should be instituted as soon as practicable. 6. POSTANAESTHETIC CARE 6.1 The anaesthesiologist should issue clear instructions concerning monitoring of post-anaesthetic care when handing over the patient to post-anaesthetic care unit (PACU) staff. Appropriate monitoring facilities should be available in the PACU. 6.2 In the unusual circumstance that a patient is transferred to general ward with arterial line, e.g. waiting for ICU/HDU bed in general ward or pending CT scan for consideration of re-operation, it is essential to properly handover the plan and care of such line. 7. REFERENCE - Guidelines on Monitoring During Anaesthesia. Australian and New Zealand College of Anaesthetists. PS18 (2015) - Checketts MR, et al. Recommendations for Standards of Monitoring During Anaesthesia and Recovery 2015: Association of Anaesthetics of Great Britain and Ireland. Anaesthesia 2016; 71: 85-93. - Standards for Basic Anesthetic Monitoring. The ASA House of Delegates. (2015)