H-8 Fall Arrest System EN 353-1:2014

Similar documents
H-50 Fall Arrest System EN 353-1:2014

H-50 Fall Arrest System EN 353-1:2014

H-50.2 Fall Arrest System EN 353-1:2014

FIXED LADDERS ALO 60 & ALO 72

FIXED ACCESS LADDERS, ALUMINIUM 60x20

Operation & Maintenance instructions for the Söll Vi-Go type fall protection system with guided type fall arrester

Guided type fall arrester including a rigid anchor line - H-50.2 System

Instructions for use / test book

SpanSet Gotcha CRD User Instructions. SpanSet Certified Safety

PHOENIX, ARIZONA USA

Manual for the. Installation. Use and Maintenance. "Söll-GlideLoc" fall arrest system. Ho-Ver turn table

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

OPERATING INSTRUCTIONS (Translation) Rope Winch Type , , ,75

Usage and maintenance manual for the fall arrester system of the Söll GlideLoc type with a guided type fall arrester. Söll Comfort 2. Order No.

USER MANUAL Do not throw away these instructions. Read and understand these instructions prior to use of the Lad Grab Safety System.

User Instructions 1789 Parapet Wall Anchor

GOTCHA CRD. Rescue, hoisting and abseiling equipment EN341 / EN1496 CE0158 TECHNICAL DATA

Floor Mount Socket. T: +44 (0) F: +44 (0)

Installation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System. Warning

Instruction Manual AC350 GUIDED-TYPE FALL ARRESTER ON RIGID ANCHORAGE LINE EN 353-1:2002

Height Safety Lifting Load Control Safety Management GOTCHA Rescue Range TECHNICAL DATA

Safewaze FS983 Cable Safety Climb System Ladder Mount Instructions

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

Product Numbers & Ordering Information

RESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx

Operation & Maintenance instructions. for the Söll Vi-Go type fall arrest system with guided type fall arrester

??????? is committed to providing a safe work environment for its employees and preventing occupational injuries due to falls.

OPERATING INSTRUCTIONS (Translation) Rope winch Type KWE 250 KWV 300 KWE 650 KWV 650 KWE 1000 KWV 1250

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

ROLLGLISS TOP/R350. Safety and rescue system. Operating and Maintenance Instructions

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

Manual winch MANISTOR 100 and 200

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

MSA Latchways Ladder System

GUIDELINES FOR USE GUARD

1 SafeClaw Anchorage Connectors

08/2017. No Instructions for assembly and use for fixed ladders

Reliance Industries, LLC Operating instructions for the / Bolt-on D-Ring Anchorage. Model # 3071

Operating instructions. Skyline Beam Clamp

Operating manual for descender and rescue lifting devicesafescape

Operating instructions. Bolt-on Bar Joist Anchorage

User Instructions 1790 Rail Anchor

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

MANUAL SEALLESS STEEL STRAPPING TOOL MODEL A

BC Shackle. Made in the China. Alloy Steel Anchor Shackle. Instructions for handling and use - Please read in full before using this device

User Manual 1792 Standing Seam Metal Roof Retractable Swivel Anchor

ROOF ANCHOR / D-RING ANCHOR PLATE

Security and confidence at height.

User Instruction Manual Fixed Beam Anchor

Figure 1 - Parts Identification. Copyright 2002, DB Industries, Inc.

SECURITY AND CONFIDENCE AT HEIGHT

3/4 SafeClaw Anchorage Connectors

Manual. for the Installation, Use and Maintenance. Söll-GlideLoc fall arrest system. Rotary-Exit-Section

GM-121: Container End Lock Anchor Wand Page 1 WINSAFE CORP. GM 121 CONTAINER END LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

Type BBS-03, BBS-05, BBS-06, BBS-25

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200

Personal Protective Equipment

GM-120: Container Top Lock Anchor Wand Page 1 WINSAFE CORP. GM 120 CONTAINER TOP LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

IMPORTANT: If you have questions on the use, care, or suitability of this equipment for your application, contact DBI/SALA.

LAD-SAF LAD-SAF VERTICAL SAFETY SYSTEM THE ULTIMATE IN FALL PROTECTION

HELM Hinging facility according to EN 795:2012 Typ D. Sliding hardware

CHOKER JOKER LIGHT CAMBIUM SAVER

Safety Equipment Manufacturer Committee Consensus Document

Operating Instructions

>PSA-VRS< >PSA INOX STAR< M12 (1 Pers.)

User Instruction Manual

>PSA-VRS< >PSA INOX STAR< M12 (1 Pers.)

GUIDELINES FOR USE -GUARD

Installation Drawings & Instructions Fall Protection Systems

User Instruction Manual Fixed Beam Anchor

Figure 1 - Parts Identification

Overview. Identify fall hazardous areas Describing potential fall hazards How appropriate portable and extension ladders are used

Made in the USA. For Fall Protection Only. SafeLok Part Description

Quattrocycle BV. Quattrocycle. User Manual. Last update February Quattrocycle BV Bremkant EJ Middelbeers. User Manual Quattrocycle 1

INSTRUCTIONS FOR USE

Tripod. System. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

All rights reserved 2010 Les Fabrications TJD inc.

TRAVSMART permanent single-cable horizontal lifeline system

2000 lb manual winch

Installation & User Manual

INSTALLATION. USE AND MAINTEINANCE INSTRUCTIONS FOR COLLAPSIBLE COLUMNS WITH HAND BALANCED SYSTEM

Fall Protection Checklist. Guardrail System

OPERATOR S MANUAL SPREADER. CSS, VNQ [For Combine Harvester AW82V] Original instructions

Fall Control User Instructions

SASK-A-POLE OWNERS AND USERS MANUAL

AVANTI ANCHOR SAFETY POINT User s, Maintenance and Installation Manual

PF30 Inspection & Maintenance Manual

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # VBC014N

INSTRUCTIONS FOR USE

High level Access solutions. Hailo Wind Systems. Service lifts and access technology. English

WINSAFE CORP. OPERATING AND MAINTENANCE INSTRUCTIONS GM184 TOP ACCESS END LOCK ANCHOR WAND

Operator's Manual Supplement

Figure 1 - Cable Grip Horizontal Lifeline Termination ZORBIT ENERGY ABSORBER RELEASE TAB

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

Deans, Directors, Heads of Schools and Departments and Research Institute Directors and Managers

INSTALLATION AND USAGE HANDBOOK

OCCUPATIONAL HEALTH AND SAFETY ACT FALL PROTECTION REGULATIONS

User Instruction Manual For Davit Rescue System

Transcription:

Hailo Wind Systems H-8 Fall Arrest System EN 353-1:2014 Rope System ø 8mm System Components Information booklet about Assembly Using Inspection Professional Ladder Technology for Structural Engineering, Wind Turbines, Shaft Equipment

Introduction Dear customer, In purchasing the H-8 fall arrest system, you have opted for a quality product from the Hailo Wind Systems company. We thank you for your trust in us. This information booklet describes the assembly, use, maintenance and checks for the H-8 fall arrest system. Please read this booklet through in full and respect all the safety advice before beginning to assemble and use the H-8 fall arrest system. In the event of damage arising due to a failure to respect the details in this information booklet and the safety instructions, the warranty lapses. We accept no liability for consequential losses arising from this. The H-8 fall arrest system satisfies the requirements of the applicable European Directive on Personal Protective Equipment for fall protection (89/686/EEC). EU Type Testing was carried out at DEKRA EXAM GmbH - Prüflaboratorium für Bauteilsicherheit - Dinnendahlstr. 9, D - 44809 Bochum reference number: 0158. If you have any other questions or comments about our H-8 fall arrest system, please don t hesitate to call us. We d be delighted to assist. Hailo Wind Systems GmbH & Co. KG Kalteiche-Ring 18, 35708 Haiger, Germany +49 (0) 2773 82-0 +49 (0) 2773 82-1561 E-Mail: info@ hailo-windsystems.com www.hailo-windsystems.com 2

Table of contents: EMERGENCY TELEPHONE NUMBERS: We recommend that all users add the emergency telephone numbers listed below as contacts on their mobile phones. Emergency services:.................................... Fire service:.................................... Plant operator:.................................... Hailo Service Hotline:.................................... Other important phone numbers:.................................................................................. Introduction......................... 2 1. Initial Notes......................... 4 2. EC Declaration of Conformity.............. 6 3. EC-Type Examination Certificate............ 7 4. System Details........................ 8 5. Safety Instructions.................... 10 6. Performance Data.................... 16 7. Standards and Regulations.............. 17 8. Overview of System Components.......... 18 9. Advice on Assembly................... 20 10. Assembly of H-8 Fall Arrest System......... 22 11. Use of H-8 Fall Arrest System............ 34 12. Markings and Notices.................. 40 13. Rescue Measures..................... 42 14. Assembly Log....................... 44 15. Inspection H-8 Fall Arrest System.......... 46 16. Inspection Plan H-8 Fall Arrest System...... 48 17. Documentation of the Inspection H-8 Fall Arrest System................. 52......................................... 3

1. Initial Notes Texts or drawings tagged with these symbols flag up content and dangers that are of particularly importance. Failure to comply with these instructions may result in injury or loss of life. Symbols used in this information booklet: General warning advice This information booklet must be read carefully and the contents noted before installing or using the H-8 fall arrest system. The operator must ensure that this information booklet is available on site for every H-8 fall arrest system (or kept in a suitable location) and if required can be made available to the user at all times. Danger of falling General instructions See documentation Use Personal Protective Equipment (PPE) against falls from a height Additional advice On tall buildings or for deep shaft facilities, fall arrest systems are a mandatory requirement above a fall height 5 m (per DIN 18799-1) or 3 m (per EN ISO 14122-4). The H-8 fall arrest system is designed as a fall safety when using rung ladders and pole climbers, both above ground and below ground. Rope systems are fitted (to the side or centrally) to the ladders or pole climbers attached to the structure and are used for securing and guiding the SSL-8-R1 fall arrester. The SSL-8-R1 fall arrester when attached to the fall arrester rope is fitted with a BFD-50/8-1 shock absorber and is connected to the user s safety harness. The SSL-8-R1 fall arrester is approved solely for the protection of the user. The fall arrester is easy to attach and secure to the fall arrester rope, is self-locking in the event of a fall and with its easy-glide action along the wire cable without obstructing the user as it moves guarantees a safe passage up and down. 4

The Hailo H-8 fall arrest system may only be used with a Hailo SSL-8-R1 fall arrester. Therefore, before installing the H-8 Fall Arrest System, it is necessary to provide the respective user with an SSL-8-R1 Fall Arrester. The number of fall arresters required depends on the number of personnel who will be using the fall arrest system. SSL-8-R1 fall arrester The use, cleaning and storage of the fall arrester must only be in accordance with the specifications set out in the information booklet SSL-8-R1 fall arrester with integrated BFD-50/8-1 shock absorber 5

2. EC Declaration of Conformity The manufacturer or his authorised agent resident in the EU: Company: Hailo Wind Systems GmbH & Co. KG Kalteiche-Ring 18, 35708 Haiger, Germany hereby declares that the H-8 Fall Arrest System described on the following pages conforms to the provisions of Directive 89/686/EEC, EN 353-1:2014 (for PPE pursuant to Article 8, Para. 3, of the Directive) is identical to the PPE which was the subject of the EC-Type Examination Certificate No. ZP/B145/17 issued by DEKRA EXAM GmbH - Prüflaboratorium für Bauteilsicherheit Dinnendahlstr. 9, D - 44809 Bochum, Ref. no.: 0158 and the procedure according to Article 11 Letter A of Directive 89/686/EEC as monitored by the registered office DEKRA EXAM GmbH - Prüflaboratorium für Bauteilsicherheit Dinnendahlstr. 9, D - 44809 Bochum, Ref. no.: 0158. Haiger, 2017-06-06 Place, date Signature of authorized person (Dirk Mischnick) 6

3. EC-Type Examination Certificate 7

4. System Details Manufacturer s information: Hailo order number:........................................................................... Site information: (to be completed by the operator) Name (operator):............................ Telephone:................................ Street:................................ Fax:................................ Postcode, town:................................ E-Mail:................................ Date of commissioning:........................ Date Signature of Operator 8

System information: (to be completed by the Assembly Manager) Climbing unit:........................ Ladder system (Hailo) Ladder system (customer-supplied) Pole-climber (customer-supplied) Ladder design:....................... AL (Aluminium) VA (Stainless steel) ST (Steel-galvanized) Other Rope design:........................ ES 8 (Stainless steel) ZS 8 (Steel-galvanized) Type of assembly:..................... On side of upright Centre of rung On a ladder system provided by the customer Markings (see wire rope thimble swaging on rope) Batch no./plate no.:....................................... Date Signature of Assembly Manager 9

5. Safety Instructions Information on system equipment, assembly and repairs If the safety instructions on Pages 10 to 15 are not respected, then the manufacturer warranty lapses! The H-8 fall arrest system is tested and licensed as an overall system. Combining this equipment with components from other manufacturers may result in failure of the overall system. The safe function of a part of the equipment or of the equipment in combination can be impaired, and there is a possible risk of falling or injury. Only system components from Hailo must be used for the H-8 fall arrest system. It is not permitted to use Hailo parts in conjunction with those of other manufacturers. Where the use of other manufacturers components is unavoidable, this requires written authorisation from Hailo. The H-8 fall arrest system must only be used for the intended purpose. The use of this equipment for a purpose for which it is not intended is expressly forbidden, since this can lead to damage and thus to failure of the fall arrest system in the event of a fall. No modification or addition to the equipment should be undertaken without obtaining the express agreement of the manufacturer in writing beforehand. If a Hailo H-8 fall arrest system is retrofitted on an existing ladder facility or pole climbers, then in the event of any doubt (e.g. if the cross-section is smaller, if the stile-rung joint is not capable of bearing the load, if there is corrosion or poor anchorage to the building) safe use must be guaranteed taking account of stateof-the-art engineering and/or by involving an engineering office to design and assess the provision. It should be ascertained that the overall system is able to accommodate the dynamic load generated by a fall of 6 kn and a static load of 15 kn. If the necessary proofs (for safe accommodation of forces on the customer side) are not conducted, then in the event of an accident the ability to invoke the manufacturer s product liability is compromised. Liability then passes to the operator. Before each use, the necessary clear space in the working area below the user must be ensured, so that in the event of a fall no impact with the floor or other obstacle is possible. In addition, a safe distance of 3 m is to be maintained (see page 16). The protection afforded by the fall arrest system is invalidated if the user is in the bottom section of the runged ladder. Please take note of the performance data for the fall arrest system. (see page 16). 10

Transport and storage: All component parts of the system are to be secured in such a way that their function is not impaired and all components are to be kept in sound condition with respect to safety. Before assembling the fall arrest system, all the parts must first be inspected to ensure they are in sound condition. If any damage has occurred to the system components in transport the component cannot be used. The system or component parts of the system are to be replaced immediately if there is any doubt as to their safe condition. This must be carried out by the manufacturer or by other trained personnel. A system or component part of a system which has been subjected to stress as a result of a fall is to be tested by trained personnel before further use and if necessary repaired or replaced. When using a combination of equipment parts (e.g. combining a user-specific safety harness with the fall arrester), it is absolutely essential that this does not result in any impairment of the overall system. In the event of a fall, any impairment can result in a failure of the fall arrest system. When a fall arrest system is retrofitted by the operator, the relevant standards need to be met (see page 17). When undertaking assembly, servicing or repair work, ensure that no scaffolding, platforms or any other items project into the potential fall area, thus constituting an additional danger in the event of a fall. The H-8 fall arrest system meets the highest safety requirements. It is tested and certified according to European and other international regulations. The use of climbing aids (either motor-driven or systems based on a counterbalance weight) may impair the safety and function of the H-8 fall arrest system. Any operator and company who combine the two systems are responsible for ensuring that they are used solely in accordance with the regulations. A function test with subsequent declaration of non-objection conducted and certified by an accredited test laboratory is therefore essential. The unrestricted safety and function of the H-8 fall arrest system in conjunction with the respective climbing aid must be assured and documented. Repairs may only be carried out by trained personnel and individuals authorised by the manufacturer. In addition, repairs must be carried out in compliance with the procedures specified by the manufacturer. During assembly and use of accessories for this system, the accompanying instructions must be respected accordingly. The user must follow the recommendations for use with other system components (see the Overview of System Components, page 18 and 19). 11

5. Safety Instructions Use of H-8 fall arrest system Before each use of the H-8 fall arrest system, a visual check of the system and the function of the SSL-8-R1 fall arrester must be carried out, employing the information booklet. Before using the fall arrest system with the fall arrester, the system needs to be inspected to ensure that it is in proper working order. It is not permitted to use the equipment where there are instructions regarding severe icing or contamination of the fall arrest system or where there is already severe icing or contamination. Contaminated or damaged equipment parts impair the function of the fall arrest system. In particular, the fall arrest track must be kept in a clean and sound condition. Contact with oil, acid or other caustic liquids is to be avoided. It is not permitted to use a contaminated or damaged fall arrest system. The fall arrest system is designed for operation in temperatures ranging from -40 C to +50 C. Extreme temperatures and weather conditions (e.g. heavy rain, snow and ice and temperatures of <-40 C or > +50 C) may interfere with the functionality of the fall arrest system. The fall arrest system must not be used in these conditions. The accident prevention regulations DGUV regulation 1 and DGUV rules 112-198/199 (Germany) must be respected. The user of the fall arrest system should never be alone when using the system, as a second person should be available to call for immediate help in the event of an accident. It is strongly recommended that users always carry a mobile phone. The user of the fall arrest system must be physically and mentally capable of movement using the respective equipment. If he has been required to take medicines in advance of using the equipment, it is advisable to find out about possible side-effects which might result in impairment or physical injury if moving around using the equipment. In addition, users must investigate the local conditions beforehand in order to establish whether any specific areas at the site might constitute a hazard. The maximum number of personnel permitted to use a fall arrest system at the same time is three at a minimum distance of 6 m from each other. Prior to starting work, the user of the H-8 fall arrest system must seek information from the plant operator regarding an emergency plan as well as any rescue measures that might be necessary and how to initiate and execute them. The contractor or operator of a plant must put in place a plan which covers all possible emergencies that might arise when using the fall arrest system and outlines the measures required for rescuing personnel. 12

Use of Personal Protective Equipment (PPE) When using the H-8 fall arrest system, it is absolutely essential to use the Hailo SSL-8-R1 fall arrester as Personal Protection Equipment (PPE). [A] Before using the H-8 fall arrest system, follow the instructions in the information booklet for the fall arrester. Personal protective equipment may only be used for the intended purpose and by such persons as have been instructed in its safe use and who possess the corresponding knowledge. The personal protective equipment should be in the personal possession of the respective person and only used by this user. Use by a more extended group of people is not to be considered advisable. Do not use any support harnesses, seat harnesses or older Form B safety harnesses which only partially enclose the body. These harnesses should not be used when climbing. Use only DIN EN 361-compliant safety harnesses, and respect the user instructions accompanying them! The SSL-8-R1 fall arester is approved for a total weight (i.e. the user s body weight plus clothing and equipment) of min. 50 kg to max. 136 kg. The spring hook on the shock absorber may only be attached to the authorised retaining eye on the safety harness [A]. The SSL-8-R1 fall arrester must not be connected to any retaining eyes to the sides of the safety harness that may be provided as an additional element in the hip area. The SSL-8-R1 fall arrester may only be used for climbing and descending using the H-50 fall arrest system. The use of this equipment for a purpose for which it is not intended is expressly forbidden, since this can lead to damage and thus failure of the SSL-8-R1 fall arrester in the event of a fall. The SPL-8-R1 fall arrester may not be used for work positioning. If work positioning is required, a separate system must be used. 13

5. Safety Instructions Use of Personal Protective Equipment (PPE) The user must not touch or manipulate the fall arrester while climbing or descending. Such action may impair or even prevent the braking action of the equipment. For reasons of safety, the user is not permitted to grip or manipulate the fall arrester while climbing or descending, except when the user is in a position of safety and there is no risk of falling. When a system or component parts of a system have been subjected to stress as a result of a fall, they are no longer approved for further use. In this case, the SSL-8-R1 fall arrester must be returned to the manufacturer for testing and/or repair. Repairs to the fall arrester may only be carried out by the manufacturer. The SSL-8-R1 fall arrester is safe to use on a fall arrester rope which deviates from the vertical by no more than +15 /-0. Additional attaching elements: The lengths of the attaching elements for supplementary fall safety systems should be selected to be as short as possible, so that in the event of a fall the distance of the fall is correspondingly limited. Additional attaching elements, e.g. Y harnesses, should only be attached to the fastening-points provided for them (EN 795). The safety of the user of the fall arrest system depends on the effectiveness of the equipment! Only original Hailo parts may be used on the SSL-8-R1 fall arrester. Defective or worn parts may only be replaced by Hailo parts. Only safety harnesses which comply with EN 361 are permitted for use with the SSL-8-R1 fall arrester on the fall arrest system. Please follow the instructions for use for the safety harnesses used. Do not use any support harnesses, seat harnesses, elasticated harnesses or older Form B safety harnesses which only partially enclose the body. These harnesses should not be used when climbing. Connecting parts on the fall arrester must not be lengthened or shortened. The safety harness must sit firmly on the body and be correctly adjusted [B], [D]. It is forbidden to use the fall arrest system with a loose safety harness that has not been adjusted to provide a sufficiently tight fit [C], [E]. 14

[B] [F] [C] [D] [E] The user should basically avoid standing in a position on the fall arrest rope where they are directly above the fall arrester [F]. Warning Risk of falling! 15

6. Performance Data The SSL-8-R1 fall arrester on the H-8 fall arrest system does not provide protection when the user is in the lower section of the climbing unit (< 3m from the upper edge access level). The plant operator must install a corresponding warning notice (see the Sticker on Safe Distance) on the building to inform the user beyond all doubt regarding the safe distance. Arrest distance Block travel For the H-8 fall arrest system, calculating the performance data and the necessary free space to arrest the person in the event of a fall indicates a safe distance of 3 m. Safe distance = 3 m 16

7. Standards and Regulations 89/656/EEC BetrSichV DGUV regulations 1 Minimum health and safety requirements for the use by workers of personal protective equipment at the workplace Occupational health and safety legislation Ordinance on safety and health protection in the supply of work equipment and its use in the workplace, safety in the operation of plant requiring monitoring and the organising of health and safety in operations Accident prevention regulations Principles of prevention DGUV information 208-016 Guidelines for the use of ladders and steps DGUV rules 112-198 DGUV rules 112-199 EN 353-1:2014 EN 361 EN 13101 Ruling on the use of personal protective equipment to prevent falls Ruling on the use of personal protective equipment for rescue at height or underground Personal protective equipment to prevent falls from height: Guided type fall arrester including rigid anchor line Personal protective equipment to prevent falls from height: Full body harnesses Pole climbers in manholes EN ISO 14122-1 Safety of machinery Permanent means of access to machinery Part 1: Choice of fixed means of access between two levels EN ISO 14122-4 Safety of machinery Permanent means of access to machine plant Part 4: Permanent vertical ladders EN 14396 Fixed ladders for manholes DIN 18799-1 Fixed ladders for construction work Part 1: Fixed ladders with uprights safety requirements and tests EN 795 DIN CEN/TS 16415 EN 50308/B-1 Anchor devices Anchor devices: Recommendations for anchor devices for use by more than one person simultaneously Wind turbines labour safety 17

8. Overview of System Components All the illustrations provided are examples and may differ from the version shown depending on the design. Rung ladder Mat.: stainless steel / steel-galvanized Rung ladder Mat.: aluminium Rope guide fitted sideways on the rung Rope guide fitted centered on the rung 18

Rope attachment TOP, sideways on the rung Rope attachment TOP, centered on the rung Rope attachment TOP, un structure For more information on the design and item number of the individual products, please visit: www.hailo-windsystems.com Rope attachment BELOW, sideways on the rung Rope attachment BELOW, centered on the rung Rope attachment BELOW, on structure 19

9. Advice on Assembly Preliminary note Before commencing assembly, first ensure that the requisite loads can be accommodated by the structure. If documentation confirming this is not available, then a statics report taking account of the requisite load accommodation is a mandatory requirement and must be verified. If the required proof (that the customer s facilities can safely accommodate the requisite forces) is not available, then the manufacturer may refuse liability for the product in the event of a claim. Liability then passes to the operator. Make sure that the instructions for installing a rigid anchor line are followed and that this is installed at a maximum angle of +15 /- 0 to the vertical. Fitters At least two people are needed to assemble the fall arrest system. The fitters cannot be secured on the system to be installed. To secure the fitters, an approved fastening point pursuant to DIN EN 795 on the building or on some other construction element is to be used. Information on fitting the system to concrete structures: Only dowels permitted under building regulations requirements may be used for concrete structures. When assembled on unspecified foundation material, the fastening system is to be implemented in consultation with the design engineer responsible for the supporting framework. Concrete requirement: Concrete of at least category C 20/25 is required. Information on fitting system to masonry: Before fitting the vertical ladder, ensure that the transfer of forces to the load-bearing structure is guaranteed with adequate safety (in consultation with the design engineer responsible for the supporting framework). Follow the fitting instructions provided by the manufacturer of the dowels. Only dowels permitted under building regulations requirements may be used for masonry. When assembled on unspecified foundation material, the fastening system is to be implemented in consultation with the design engineer responsible for the supporting framework. It is also possible to anchor the system through the masonry using a counter plate. This should be discussed and verified with the structural engineer. 20

Screw tightening torques When using steel screws: Max. tightening torques in (Nm) with a total coefficient of friction of μ = 0.08 ( μ = 0.08 corresponds to a galvanised, unoiled, dry surface) Property class 8.8: Property class 10.9: M 8 = 17,9 Nm M 8 = 26,2 Nm M 10 = 36,0 Nm M 10 = 53,0 Nm M 12 = 61,0 Nm M 12 = 90,0 Nm M 16 = 147,0 Nm M 16 = 216,0 Nm M 20 = 297,0 Nm M 20 = 423,0 Nm When using A2 + A4 stainless steel screws: Max. tightening torques in (Nm) with a total coefficient of friction of μ = 0.10 ( μ = 0.10 corresponds to an unoiled, dry surface) Carrying out assembly Only use absolutely clean and undamaged system parts. Particular attention is to be paid to ensuring undamaged fall arrest ropes.. Damaged parts must be replaced using new parts. The testing plan and test log for the H-8 fall arrest system are found on pages 48-55. The assembly log for the H-50 fall arrest system is found on pages 44/45.. Assembly log Assembly of the H-8 fall arrest system is to be documented by the assembly manager for the assembly firm in full, permanently, and legibly, in the assembly log. Property class 70: M 8 = 14,5 Nm M 10 = 30,0 Nm M 12 = 50,0 Nm M 16 = 121,0 Nm M 20 = 244,0 Nm Property class 70 corresponds to cold-press fabrication up to a nominal length of 8 x d and a utilisation of the yield strength of Rp 0.2 = 90%. Warning Risk of falling! During assembly, use a fall arrest system complying with the specifications of DIN EN 363 21

10. Assembly of H-8 Fall Arrest System 10.1 Preliminary advice on installing the rope system Fitting the wire cable clamps The first wire cable clamp is attached tightly to the cable thimble. The wire cable clamps must be attached as far from each other as to leave a distance of at least one wire cable clamp width (shown as t) between them. The shackles on the clamps should always be placed on the unstressed end of the cable. A torque of 6 Nm is required. (This torque applies to greased threads and contact surfaces of nuts.) When installing and before commissioning, the collar nuts are to be tightened according to the torque specified. After weight has been fully applied to the system for the first time, the torque must be checked once again and if necessary re-adjusted. Setting the rope tension Preload the spring of the rope tension unit to 140 mm (this equates to a tension force of approx. 800 N). Rope systems must be securely anchored at the top and bottom ends. When securing the system, the fall arrester rope must be tensioned/preloaded with a force of at least 0.8 kn. 22

Limit stop TOP / Positioning the wall brackets The following requirements in respect of the positioning of the upper wall brackets must be met when securing the rope system to the top 3 rungs of the ladder (on limit stop TOP [A]): Wall bracket with upright clamp [B]: The distance from the wall bracket to the end of the ladder must be not more than 280 mm. Wall bracket with rung adapter [C]: The wall bracket must be secured to the last rung of the ladder. 23

10. Assembly of H-8 Fall Arrest System 10.2 Positioning the rope system The arrangement of the limit stop TOP/BOTTOM and the rope guide on the vertical ladder can be varied. The system components of the Fall Arrest System can be fitted to the vertical ladder both in the center and at the side (either to the left or to the right) and/or to the structure. The specified tread widths must be observed without fail. These are: Fitted in the center = min. 2 x 150 mm Fitted to the side = min. 300 mm 1) Examples: 1) Fitted to the side LEFT 2) Fitted to the vertical ladder CENTER 3) Fitted to the side RIGHT Arrangement of system components is turned through 180 4) Fitted to structure LEFT When installing the system components, ensure that the fall arrester rope is fitted in the vertical position. The distance of the rung adaptors (Rope attachment TOP, rope guide and Rope attachment BOTTOM) to the upright must always be the same. 24

2) 3) 4) 25

10. Assembly of H-8 Fall Arrest System 10.3 Fitting to a fixed vertical ladder - aluminium vertical ladder Fitting the H-8 rope attachment TOP, The H-8 rope attachment TOP is fitted to the top 3 rungs on an aluminium vertical ladder. Fitting the rung reinforcement SV3: 1) Insert a tube [A] into each of the top three rungs and in addition to this insert a rod for flexural strength [B] into the centre rung. 2) Bolt both vertical bars [E] to the stiles of the ladder with the inserted tubes. 6 x (M16 x 50, torque = 80 Nm). 3) Fitting the limit stop: Secure the retainer [D] to the stop plate [E] 2 x (M10 x 30, property class 8.8, DIN 933/ ISO 4017). Secure the stop plate [E] to the top three rungs using the three rung adaptors. Fix the H-8 fall arrester rope [F] to the bracket. 1 x (M12 x 70). Safe distance = 3000 mm 26

1) 2) 3) 27

10. Assembly of H-8 Fall Arrest System 10.3 Fitting to a fixed vertical ladder - aluminium vertical ladder 4) Fitting the rope guide H-8 4) Max. distance between the individual rope guides = 9520 mm (i.e. every 34th rung when the distance between rungs is 280 mm). Fitting the Rope attachment BOTTOM 5) Secure the rope tension unit [H] to the limit stop. Either secure to the rung or fit to the floor (see page 29: Fitting to a structure). [H] 5) 28

Fitting to a structure 6) Fitting the tie-bar to the structure [G] (Attachment for fall arrester rope) For concrete structures, only anchor dowels permitted under building regulations may be used (at least 6 pces. M10 x 100). For steel structures, hexagonal bolts in accordance with ISO 4017/4014, min. property class 8.8, are permitted (at least 6 pces. M10). These can be bolted into tapped holes or passed right through the structure. If the structure is fabricated in a different material, a method for fixing the tie-bar must be identified, selected and implemented in consultation with the structural engineer according to technical regulations. 6) 29

10. Assembly of H-8 Fall Arrest System 10.4 Fitting to a fixed vertical ladder (galvanized) steel or stainless steel vertical ladder Fitting the H-8 rope attachment TOP The H-8 limit stop TOP is fitted to the top 3 rungs on a steel vertical ladder. Fitting the rung reinforcement to the top two rungs: 1) Insert the reinforcing tube [I] into the U-profile from below and bolt to the vertical ladder. 2) Fitting the limit stop: Secure the retainer [D] to the stop plate [E] 2 x (M10 x 30, property class 8.8, DIN 933/ ISO 4017). Secure the stop plate [E] to the top three rungs using the three rung adaptors. Secure the H-8 fall arrester rope [F] to the retainer 1 x (M12 x 70). Safe distance = 3000 mm 30

1) 2) 31

10. Assembly of H-8 Fall Arrest System 10.4 Fitting to a fixed vertical ladder (galvanized) steel or stainless steel vertical ladder 3) Fitting the rope guide H-8 3) Max. distance between the individual rope guides = 9520 mm (i.e. every 34th rung when the distance between rungs is 280 mm). Fitting the Rope attachment BOTTOM 4) Secure the rope tension unit [H] to the limit stop. Either secure to the rung or fit to the floor (see page 33: Fitting to a structure). [H] 4) 32

Fitting to a structure 6) Fitting the tie-bar to the structure [G] (Attachment for fall arrester rope) For concrete structures, only anchor dowels permitted under building regulations may be used (at least 6 pces. M10 x 100). For steel structures, hexagonal bolts in accordance with ISO 4017/4014, min. property class 8.8, are permitted (at least 6 pces. M10). These can be bolted into tapped holes or passed right through the structure. If the structure is fabricated in a different material, a method for fixing the tie-bar must be identified, selected and implemented in consultation with the structural engineer according to technical regulations. 5) 33

11. Use of H-8 Fall Arrest System 11.1 Safety Instructions Initial notes: On tall buildings or for deep shaft facilities, fall arrest systems are a mandatory requirement above a fall height 5 m (per DIN 18799-1) or 3 m (per EN ISO 14122-4). Entry and exit points are situated at the start and end of the climb, and at rest platforms along the fall arrest system. Entry to the fall arrest system resp. exiting the fall arrest system is via an end-stop or a pivoting withdrawal point. Both on entering and leaving the fall arrest system, the user must be secured to an approved fastening point appropriate to local conditions to prevent falling. This requires the karabiner clip [A] of the means of attachment in accordance with EN 363 to be attached either to an approved fastening point [B] in accordance with EN 795 on the building or to another structure. The existence and position of approved fastening-points must be clarified with the plant operator. Stop points and stop devices used in a climbing system are to be positioned so that free falling and the fall height are restricted to a minimum. The fastening point must be within the radius of action for the user while still secured on the fall arrest device. In general, the user should always select stop devices/ stop points that are situated above them. A check should be made for possible stop points and stop devices before each use. The system may only be entered or exited from a safe standing position. At no time should there be any risk of falling. 34

Cleaning and Care Where component parts of the fall arrest system in particular the fall arrest track become contaminated by concrete dust, sand, soil or other substances, this should be cleaned off with warm water (max. 40 C) and an acid-free cleaner. Testing and maintenance: Fall arrest systems must be inspected and documented for good working order and functionality at least once a year by trained/authorised personnel. An expert/authorised person is: A person who on the basis of specialist training (cf. DGUV 312-906/TRBS 1203) and his personal experience, has gained the necessary knowledge for this safety device, and who is also familiar with the generally recognised state-of-the-art and the relevant guidelines to the extent that he can assess its safe condition for use and its appropriate application. See test schedule and documentation on the H-8 fall arrest system on pages 48-55. The testing of all components, each individual subsystem and system must be documented. 35

11. Use of H-8 Fall Arrest System 11.2 Description of the SSL-8-R1 Fall Arrester SSL-8-R1 fall arrester with integrated BFD-50/8-1 shock absorber Before using the SSL-8-R1 fall arrester, read this information booklet through in full. Take note of the safety instructions! The Hailo SSL-8-R1 fall arrester is designed for fall arrest equipment pursuant to EN 353-1:2014 and is suitable as reliable fall protection on ladders and pole climbers. The Hailo SSL-8-R1 fall arrester satisfies the regulations set out under EN 353-1:2014. The fall arrester is locked onto the fall arrester rope before climbing/descending. The SSL-8-R1 fall arrester when attached to the fall arrester rope is fitted with a BFD-50/8-1 shock absorber and is connected to the user s safety harness. The SSL-8-R1 fall arrester is approved solely for the protection of the user. The fall arrester is easy to attach and secure to the fall arrester rope, is self-locking in the event of a fall and with its easy-glide action along the wire cable without obstructing the user as it moves guarantees a safe passage up and down. Before using the fall arrest system with the SSL-8-R1 fall arrester, the system must be inspected to ensure it is in good working order. It is not permitted to use the equipment where there are instructions regarding severe icing or contamination of the fall arrest system or where there is already severe icing or contamination. The fixed and integral BFD-50/8-1 shock absorber (EN 353-1:2014) must be replaced on reaching its expiry date (i.e. every five years). The shock absorber may only be replaced by the manufacturer. 36

11.3 Use of the SSL-8-R1 Fall Arrester Inserting and removing the fall arrester 1. 1. Before using the fall arrester, the fixed and integral spring hook on the shock absorber must be clipped onto the retaining eye on the safety harness (pursuant to EN 361), which should be put on beforehand. Take note of the safety instructions (Pages 10 to 15)! 2. The SSL-8-R1 fall arrester is designed for ease of use when attaching it to the rope. The SSL-8-R1 fall arrester should only be attached to the fall arrester rope in the correct direction of pull (i.e. with the red arrow pointing upwards). 3. When attaching the SSL-8-R1 fall arrester, ensure that the thumb grips the fall arrester and the index finger is below the brake lever when pulling the brake lever upwards. 4. Use the other hand to loosen the knurled thumb screw and release the lock on the cover, while at the same time opening the cover. The fall arrester is then attached to the rope. 2. 4. 3. After it is attached, close the cover of the SSL-8-R1 fall arrester and secure the knurled thumb screw tightly (5.). 5. 37

11. Use of H-8 Fall Arrest System 11.3 Use of the SSL-8-R1 Fall Arrester General check and function test: The SSL-8-R1 fall arrester must first be checked visually prior to use. The SSL-8-R1 fall arrester should only be attached to the wire cable in the correct direction of pull (i.e. with the arrow pointing upwards). The shock absorber must move freely on the fall arrester. When the shock absorber is pulled upwards, the SSL-8-R1 fall arrester must be unlocked and run easily up and down the wire cable. When the shock absorber is released, the SSL-8-R1 fall arrester must lock on the fall arrester rope within 30 mm without slipping. The fall arrest effect is not operative if, during climbing or descent, a horizontal force is acting on the fall arrester. This will obstruct the fall arrester. When the SSL-8-R1 fall arrester has been tested successfully to ensure it is working properly, it is ready for use and the user can climb or descend in safety. If there is any doubt as to whether it can be used safely, the fall arrester must be taken out of service immediately. The SSL-8-R1 fall arrester is designed for operation in temperatures ranging from -40 C to +50 C. Extreme temperatures and weather conditions (e.g. heavy rain, snow and ice and temperatures of <-40 C or >+50 C) may interfere with the functionality of the fall arrest system. 38

Daily functional testing before using the H-8 fall arrest system 1. Carry out this test before using the H-8 fall arrest system. Make sure you are in a safe position before carrying out the functional test. 1. Attach the SSL-8-R1 fall arrester into the fall arrest rope at head height. Then connect the SSL-8-R1 fall arrester to the chest eyelet of your harness. 2. Allow the whole weight of your body to hang vertically down. 3. The SSL-8-R1 fall arrester must now be anchored in the rope and unable to slip. 2. 3. If the SSL-8-R1 fall arrester slips during this safety test, you must stop using it immediately and return it to the manufacturer for inspection. 39

12. Markings and Notices Please pay special attention to all markings, stickers with safety information and safety regulations. A) Information on H-8 fall arrest system (type plate) Safety instructions for attaching the fall arrester and using the H-8 fall arrest system. B) Type plate for the vertical ladder Information on the material and dimensions of the ladder as well as the load capacity. C) Plate with ladder markings Information on the Fall Arrest System. The H-8 vertical ladder must be inspected at least once a year by trained personnel and documented with a test badge. A) B) The H-8 Fall Arrest System must be identified with a type plate at the point of access which indicates the type of fall arrester to be used with the H-8 Fall Arrest System. When new types of fall arrester are used, the operator must ensure that this information is clearly visible to the user. C) If necessary, customer-specific safety and information signs can also be used; however, these are not described or illustrated here. 40

Sicherheitsabstand = 3 m Safe distance = 3 m Distance de sécurité = 3 m ACHTUNG! ATTENTION! ATTENTION! Leiter entspricht: Ladder complies to: L'echelle satisfoit aux norms: Aufstieg nur mit einem zum Führungsseil oder zur Führungsschiene zugelassenem Auffanggerät (Steigschutzläufer). Bitte nur Auffanggurte nach EN 361 (Europa) oder OSHA/ANSI standards (Nord Amerika) verwenden! Ascent only using a fall arrester (fall protection glider) suitable for the guiding cable or guide rail. Please use only safety harnesses acc. to EN 361 (Europe) or OSHA/ANSI standards (North America). Zulässige Belastung Gewic t = 150 k g Permitted load Wei g ht = 330 lbs WIN-/ SYSTEMS Ne montez sur l'echelle que si elle es! muine d'un systeme antichute Charge mox. autorisee (glissiere de protection) adapte au cable ou au rail de guidage. Poids = 150 k g Veuillez utilisier exclusivement des harnais de securite aux normes EN 361 (Europe) ou OSHA/ANSI (Amerique du Nord). DIN EN 353-1:2014 OSHA 1926.1053 OSHA 1910.27 ANSI 14.3 (Parts) AS 1657 EN ISO 14122-4 Zugang nur für Steigschutz unterwiesene Personen. Access only permitted for persons troined in fall protection. Acces reserve aux personnes au courant du systeme antichute. Montiert 0 Nächste Prüfung 0 Assembled Next inspection Monte Prochaine inspections 1025179 04/17 41

13. Rescue Measures The contractor or operator of a plant needs to draw up a plan that takes account of all potential emergencies that might arise when using the fall arrest system. Please refer to the following publications which cover the mandatory regulations: Regulations of the Employer s Liability Insurance Association (Germany) DGUV rules 112-198: Ruling on the use of personal protective equipment to prevent falls from height DGUV rules 112-199: Ruling on the use of personal protective equipment for rescue at height or underground Important information on the use of personal protective equipment: It is essential that personal protective equipment is used to protect against falls when working in locations that are difficult to reach due to their height and position. Personal protective equipment for rescue at height and underground is an integral part of rescue systems with which individuals can be raised, lowered or extricated from an emergency situation. This includes: rescue harnesses, suspension loops, lifting equipment, abseil equipment, means of attachment, attachment components and stop devices. Before selecting and using personal protective equipment for rescue, operators have to carry out a risk assessment in accordance with 4 and 5 of the Health and Safety at Work Act. According to 2 of the Use of PPE ruling, the operator must carry out an assessment of the equipment which is available for rescue purposes. Only PPE equipment with the CE mark is permitted to be selected for use in rescue measures. Only approved rescue harnesses are permitted for use. Harnesses that comply with EN 361 can also be used for rescue purposes. Rescue harnesses have at least one fastening point for attaching a means of attachment or karabiner clip. These fastening points may be rescue eyes at shoulder level, arrester eyes on the reverse or fall arrest eyes. Equipment with retaining eyes to the sides of the harness is not approved for rescue purposes. 42

Information on First Aid In the event of a fall and when the individual is left hanging in the fall arrester motionless for a prolonged time (> 15 minutes), this may constitute a serious health risk. There is a risk of suspension trauma/harness hang syndrome (orthostatic shock). Even if there appear to be no external signs of injury, the individual must sit with raised knees (see Fig. A). It may prove fatal for them if they suddenly lie flat due to overloading of the heart and kidney failure. A) It is essential in each case that the patient is examined by a doctor and given medical care to assess the condition of their health. Contact the doctor on the EMERGENCY number. 43

14. Assembly Log H-8 Fall Arrest System Assembly firm (Address):............................................................................................................... Assembly manager:..................................... The Assembly Manager is responsible for ensuring that the climbing unit and H-50 fall arrest system are properly assembled. The following checklist is to be completed by the assembly manager in detail and in full, permanently and legibly. This test checklist is an integral part of the assembly process and is to be made accessible to the manufacturer or a testing body on request. Points for inspection after the assembly Result: 1. Fall arrest device: 1.1 Position for placing the SSL-8-R1 Fall Arrester: 700 mm - 1200 mm from access level 1.2 Limit stop TOP (fitted as specified on pages 24-33) 1.3 Rope attachment (Fall arrester rope, bolt, washer and lock nut are fitted as specified) 1.4 Limit stop BOTTOM (fitted as specified on pages 24-33) 1.5 Fall arrester rope with spring compressor (preloaded spring elongation 140 mm as specified on page 22) 1.6 Rope guides fitted (distance 9520 mm as specified on pages 24-33) (No.: pces.) 1.7 Test run with SSL-8-R1 fall arrester conducted without problems Yes No 44

Points for inspection after the assembly Result: 2. Markings: 2.1 Plate with ladder markings (see chapter on markings) 2.2 Information plate: Safe distance 3 m (see chapter on markings) 2.3 Test badge (see chapter on markings) Yes No Comments: Place, date Signature of assembly manager 45

15. Inspection H-8 Fall Arrest System Testing must adhere to the respective national operating and testing regulations. Fall arrest systems must be inspected for good working order and functionality at least once a year by trained/authorised personnel. An expert /authorised person is: A person who on the basis of specialist training (cf. DGUV 312-906/TRBS 1203) and his personal experience, has gained the necessary knowledge for this safety device, and who is also familiar with the generally recognised state-of-the-art and the relevant guidelines to the extent that he can assess its safe condition for use and its appropriate application. See test schedule and documentation for the H-8 fall arrest system on pages 48-55. The testing of all components, each individual subsystem and system must be documented. In addition, regular checks must be made depending on the respectively applicable environmental conditions. This can mean that the intervals between testing are correspondingly shortened. In the event of a fall, then the fall arrest system must be checked without delay by an expert/an authorised person. Inspection and maintenance of the fall arrest system must always be carried out respecting the instructions in full. The plant operator is responsible for ensuring that testing and maintenance intervals are observed. The accident prevention regulations must be respected. DGUV information 201-019 DGUV rules 112-198 - DGUV rules 112-199 GUV-V D36 - GUV-R 177 46

Test intervals are in accordance with DGUV rules 112-198. Additional test intervals may be required due to local/operational conditions (these are to be laid down by the contractor/operator). Exception: Fall arrest devices on chimneys must be inspected at least once a year by an authorised person in accordance with DGUV information 201-014. Testing intervals depend in particular on the frequency of use, the stress imposed during use and the frequency and severity of any defects that have been identified in previous tests. When carrying out annual inspections of the limit stop (fitted to the rungs on the left, on the right or in the centre), check the bolts to make sure that they are tightly secured. The operating license will be revoked and all warranties on the part of the manufacturer will be invalidated if this device is not handled in accordance with these instructions (i.e. improper assembly or fitting, damage, etc.). Proof of regular testing is required for warranty claims. Regular checks of the equipment are a mandatory requirement. The safety of the user is dependent on the effectiveness and the durability of the equipment. 47

16. Inspection Plan H-8 Fall Arrest System Test schedule for regular testing of the H-8 fall arrest system Annual tests are to be documented in the table on pages 48-55 by trained/authorised personnel. In the event of a claim, this documentation must be submitted in full as evidence.the manufacturer must be granted access to this at all times. Result: 1. Fall arrest device 1.1 Limit stop BOTTOM Technical condition 1.2 Rope tension as specified 1.3 Rope guides (No.: pces.) Technical condition, function 1.4 Limit stop TOP Technical condition 1.5 Rope attachment Condition of bolt, washer, lock nut 1.6 Fall arrester rope Corrosion, kinks, loops, wire breakage* 1.7 Rope thimble + crimp sleeve Technical condition 2. Markings: 2.1 Original markings All markings present and easily legible? 2.2 Function test Used with SSL-8-R1 fall arrester 2.3 Documentation Has test been documented correctly and in full? * Where more than 3 individual strands of wire in a 250 mm length are broken, the cable must be replaced. 48

Inspection 1 Inspection 2 Inspection 3 Inspection 4 Inspection 5 Date (Month/Year) Date (Month/Year) Date (Month/Year) Date (Month/Year) Date (Month/Year) OK not OK OK not OK OK not OK OK not OK OK not OK YES NO YES NO YES NO YES NO YES NO YES NO YES NO YES NO YES NO YES NO 49

16. Inspection Plan H-8 Fall Arrest System Test schedule for regular testing of the H-8 fall arrest system Annual tests are to be documented in the table on pages 48-55 by trained/authorised personnel. In the event of a claim, this documentation must be submitted in full as evidence.the manufacturer must be granted access to this at all times. Result: 1. Fall arrest device 1.1 Limit stop BOTTOM Technical condition 1.2 Rope tension as specified 1.3 Rope guides (No.: pces.) Technical condition, function 1.4 Limit stop TOP Technical condition 1.5 Rope attachment Condition of bolt, washer, lock nut 1.6 Fall arrester rope Corrosion, kinks, loops, wire breakage* 1.7 Rope thimble + crimp sleeve Technical condition 2. Markings: 2.1 Original markings All markings present and easily legible? 2.2 Function test Used with SSL-8-R1 fall arrester 2.3 Documentation Has test been documented correctly and in full? * Where more than 3 individual strands of wire in a 250 mm length are broken, the cable must be replaced. 50