Installation, Operation, and Maintenance Manual

Similar documents
Installation, Operation and Maintenance Manual

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Vessel Installation and Operating Manual

SElECTING A MOUNTING location OPERATING SPECIFICATIONS* * For individual cartridge specifications, refer to cartridge literature.

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

OWNER S MANUAL. Table of Contents

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Installation and Operating Manual

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

453 Series Steam Heated Vaporizing Regulator

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Installation & Instruction Manual For Portable Series R.O. units:

BS Series Basket Strainer

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

ROPV R40 E Series User Manual

Yoke Block Instruction Manual

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Saline C 6.0 Junction Box

1020 Industrial Drive, Orlinda, TN fax

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Nitrogen Supply System

PURITY INSTALLATION INSTRUCTIONS MODEL P40

Yoke Block Instruction Manual

INSTALLATION INSTRUCTION

Iron Filter Installation / Operation Manual

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

J Air and Water Kit Instructions Part# 02584

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Accu-Tab Systems 2000 P Series by Axiall Corporation

Tsunami Breathable Air System

D Series Air and Water Kit Part# 02550

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Commercial Well Tank Installation Instructions

3M Water Filtration Products

G7S Hand Pump Owner s Manual

FLUSHMATE FLUSHOMETER - TANK SYSTEM. 501-A Series. Owner s Service Manual. 501-A Series

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

Accu-Tab Systems 1000 Series by Axiall Corporation

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

Cocoa Patio Pond with Lit Spillway

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

4 and 8 Station PDS Control Installation & Operators Manual

TITAN FLOW CONTROL, INC.

Model Portable Eyewash

CSA Sample Draw Aspirator Adapter Operator s Manual

Revolution Gurney Attachment

Tactical Sniper air rifle & carbine

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Twin System Triple System Quad System

Accu-Tab PowerBase 3012AT by Axiall Corporation

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

INSTALLATION INSTRUCTION & OWNER S MANUAL

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Purifier for Vinyl Lined Pools

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation and Operating Instructions

TactAir PCP Fill Kit/Adapter. Operation Manual

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

AND OPERATION INSTRUCTIONS

Owner s Manual W Automatic Aboveground Pool Cleaner

User Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL ZERO WASTE REVERSE OSMOSIS SYSTEM

Interface Devices, Inc. Hydraulic Mini Mule

92831 TEL: (714) FAX:

Owner s Manual AMERICAN. LiquaGen 5 Stage (RO/DI) Aquarium Reef System. YEAR Y 1

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Manual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering

MANUAL. Sesame. Thermoplastic Tank Technologies

4-in-1 Professional Inflator Kit

INSTALLATION INSTRUCTIONS AT-SERIES ANCHOR ASSEMBLY PART NUMBER: F-04CAJP 450 LB. [204kg] MAXIMUM CAPACITY (PRO POOL LIFT)

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 3035 INSTRUCTION MANUAL

KJ4000 Operating Instructions & Parts Manual NSN

MPULSE 3000TM. Instruction & Owner s Manual. Pool Water Treatment System. 890 W.Grant Rd., Tucson, AZ, (877) * (520) Fax

2 Gallon Air Compressor

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

ECONOMY POOL SUNSHINE IONIZER MODEL SPE INSTALLATION INSTRUCTIONS

PC1131 Electric Air Compressor

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

Types 749B and R130 Changeover Manifolds

Model TWBS.SH Tempered Water Blending System

FLANGED TWO-PIECE BALL VALVES

ACCU-MIX 1200 / / 26270

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Installation Instructions Air Compressor Part # 2780, 2781

GAS FRYER Instruction Manual Model #5099NS

Series 867. Reduced Pressure Zone Assemblies " 3" (65 80mm)** INDEX. Testing INSTALLATION INSTRUCTIONS WARNING NOTICE NOTICE !

Transcription:

Installation, Operation, and Maintenance Manual Product Preservers Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The Product Preservers Anti-Scale System will condition the tap water providing optimum water characteristics for many applications. The result is reduced equipment maintenance requirements, longer equipment life and improved quality & consistency of your products. The Product Preservers system is built with the finest and most advanced materials and each system is quality inspected and pressure tested prior to shipment. With proper installation and routine maintenance, you will have years of trouble-free operation. Please refer to this manual when performing routine filter changes. The instructions make periodic maintenance quick and easy and ensure you will receive maximum benefit from your system. System Specifications Model SM1.0L LG1.5L Peak Flow Rate Service Flow Rate Gallon Rating for Cartridge Maximum Pressure Temperature Inlet/Outlet Connections 6 gpm (2 lpm) 0.25-4 gpm (1-15 lpm) Up to 4 gpm, 24/7/65 for 2 years 90 psi (6.2 bar) 5 F - 100 F (2 C - 8 C) /4" FNPT Water ph 6.5 to 8.5 Hardness (max) Chlorine Iron (max) Manganese (max) Copper Oil & H2S Polyphosphate Silica (max) 10 gpm (8 lpm) 0.5-10 gpm (1.9-8 lpm) Up to 6 gpm, 24/7/65 for 2 years 75 grains (100 ppm CaCO) < ppm 0. mg/l 0.05 mg/l none allowed none allowed none allowed 10 ppm Capacity: The Product Preservers cartridge does not have a grain removal capacity, however, other contaminants present in the water will gradually degrade the effectiveness of this cartridge. Change the system cartridge at least once every two years.

Notice to Installer Do not discard this manual after installation. This manual contains important operation, maintenance and precautionary information. Please present this manual to user/operator/owner after installation. It is strongly encouraged that you read this manual before installing the system to ensure the best possible installation. Installation must conform to all local and state plumbing codes and regulations. Connect system to cold water supply only. Water temperature cannot exceed 100 F/8 C. System must be installed in a vertical, upright and level position. Product Preservers systems must not be used in conjunction with polyphosphate or any other scale inhibitor. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Notice to user/operator/owner: Please retain this manual for future reference for parts, maintenance or troubleshooting. It is recommended that all personnel responsible for operation and maintenance of this product read the precautions, operation and maintenance sections of this manual. Use caution when installing NEW COPPER LINES immediately before the Product Preservers system. Dissolved copper oxide from the new pipes can foul the Product Preservers media and the equipment will not be protected. Any system using new copper lines should be run for 4 WEEKS WITHOUT CARTRIDGE INSTALLED to allow lines to passivate.! i Installation 1. Turn off all equipment to be fed by the Product Preservers system, locate water supply shutoff valve and turn OFF. 2. Determine if the water line has an existing water treatment system. If so, examine system for use of polyphosphate or other scale inhibitors. Product Preservers will not be effective if used in conjunction with other scale inhibitors. Remove the scale inhibitors from the water line or discontinue installation.. Install a /4" full-flow ball valve on the water supply side that will feed the water system. 4. Anchor the Product Preservers system on a wall stud or suitable mounting material spanning wall studs. System must be vertical and upright. 5. Run a suitable line from the /4" full-flow ball valve at the tap water source to the inlet ball valve on the left side of the Product Preservers system. Use 2- wraps of Teflon tape and brace the inlet ball valve on the system with a wrench when connecting the feed water line. NOTE: DO NOT OVERTIGHTEN CONNECTION FITTING INTO BALL VALVE. 6. Select the appropriate size tubing for the equipment being fed and connect it to the outlet of the Product Preservers system. NOTE: DO NOT connect the tubing to the equipment at this time. Prior to making connection to the equipment, this line will be used to facilitate flushing the system. As an option, a drain valve in a tee on the outlet side of the Product Preservers system could be provided in the line to facilitate flushing when changing filters.! Installation Precautions! Do NOT install system on line pressure above 90psi. Do NOT install system on HOT water line. Failure to limit line temperature to 100 F may result in housing failure and damage. Do NOT install the system backwards with the feed water line connected to the outlet. Do NOT use liquid pipe compounds for fitting connections. USE two to three wraps of Teflon tape. Do NOT solder plumbing connections attached to filter housing or inlet valve. Inlet valve and filter housing will be damaged by high temperature. Do NOT allow system to freeze. Turn off water supply to housing and drain housing if temperature falls below 2 F. Do NOT install system in direct sunlight or where system is exposed to harsh chemicals or may be subjected to being struck by moving equipment, carts, mops or any other item that may cause damage. ALLOW a minimum of under the housing to allow for filter replacement. IF water hammer is evident, install water hammer arrestors before the Product Preservers unit. Do NOT overtighten fitting connections into inlet valve or housing outlet. Always back-up valves and fittings with a wrench when installing a fitting to avoid turning the valve. Do NOT install the unit behind equipment where it may be difficult to access the system for filter replacement. Position the Product Preservers unit in a suitable location. The direction of flow through the Product Preservers unit is always through the inlet first; keep this in mind when determining installation location. Do NOT mount the Product Preservers system near any source of heat. Also, do not mount the system above any device or area that would be adversely effected by water. 7. If using new copper lines to install the Product Preservers system, install, leak test, and run the unit for 4 weeks without cartridge installed to allow lines to passivate. Copper oxide from new pipes can foul the Product Preservers media and leave the system unprotected. 8. With Product Preservers inlet valve closed, slowly open the /4" full-flow ball valve at the tap water source. Check for leaks. 9. If a drain valve was not installed on the outlet side of the system, hold the tubing that will connect to equipment in a clean bucket or over sink or drain. Open the system inlet feed valve and allow water to flush through system for 2 minutes at the specified system flow rate to allow air bubbles to escape. NOTE: NO ACTIVATION IS REQUIRED FOR THE Product Preservers SYSTEM TO PERFORM PROPERLY. FLUSHING IS RECOMMENDED TO ALLOW AIR TO ESCAPE THE SYSTEM. 10. Make certain that the end of the tubing to be connected to the equipment is clean and sanitary. 11. Connect tubing to equipment. Open all water supply valves and check for leaks. 12. If no leaks, turn on equipment and check for normal operation. 1. Attach the Service Log to the installed Product Preservers system and fill in install date. Teflon is a registered trademark of E.I. Dupont de Nemours & Company. 2

Installation Drawings & Dimensions 10" 7 /8" 6 1 /2" 5" 5 /8" 8 5 /8" Mounted to secure wall on studs or wall panel Do not mount to unsupported sheetrock or gypsum board. 1" 4 1 /2" " /4" 2'-8" Min. 5'0" A.F.F. Installation Height " Min. Removal Clearance 5 /8" 4 1 /2" 2' 4 1 /2" 5" 6 1 /2" Max Pressure: 90psi (6.2 bar) Max Temperature: 100 F (8 C) Water treatment unit must be installed on the cold water supply only. /4" FNPT outlet connection to equipment /4" Full flow ball valve w/ /4" FNPT inlet connection from water supply Wall *Note: Both models have same external dimensions. Model Sump Color Weight SM1.0L Blue 15 lbs (6.8 kg) LG1.5L White 19 lbs (8.6 kg) Installation in a Recirculation System Air Vent Tankless Water Heater Hot Water Outlet to Fixtures Pressure Relief Valve Gas Supply Air Separator Recirculation Pump Y-Strainer Cold Water Inlet Expansion Tank Product Preservers Anti-Scale System

Operation With sufficient pressure, operation of the Product Preservers system is completely automatic. Dependable operation involves only periodic filter changes and service documentation. Maintenance Routine maintenance of your Product Preservers system involves periodic filter cartridge changes and/or replacement of sump O-rings. Filter Change Frequency If the system sizing recommendations have been followed, the Product Preservers cartridge should last two years. Replace filter every 24 months to ensure proper operation. Replacement Filter Cartridges Product Preservers systems can only be used with Product Preservers filter cartridges. Use of replacement cartridges other than those specified will void warranties, certifications and may compromise equipment protection, water quality and equipment life. Model Sump Color Replacement Filter Part Number SM1.0L Blue SM1.0L-RM 261-00 LG1.5L White LG1.5L-RM 261-001 2.. 6. 7. Filter Cartridge Replacement Procedure IMPORTANT: Determine whether all equipment connected to the Product Preservers system must be turned off prior to shutting off water supply from filters. 4. 8. 1. If required, turn off equipment. 2. Turn OFF water to Product Preservers system by closing inlet ball valve.. Press the red button to release pressure. 4. Remove housing(s) - use filter wrench if necessary. 5. Clean inside of housing sumps with warm water. If desired, disinfect housing using a teaspoon of household bleach. Add to filter bowl and add water. Let stand 5 minutes and discard. 6. Insert new cartridge into filter housing. Match cartridge model number to model number on bracket. 7. Make certain the O-ring is properly positioned and reinstall filter housing (hand tighten only). Check O-ring for damage and replace if damaged or distorted. 8. Slightly open the inlet ball valve; push the red pressure relief button to release trapped air until a small amount of water comes out - release the red button and fully open the ball valve. 9. Open the flush valve downline from the filter housing (if equipped) and flush the new cartridge to drain or bucket for two (2) minutes or until water runs clear. If no flush valve is present, disconnect line from equipment to flush to drain. 10. VERY IMPORTANT: With water supply inlet valve OPEN and water flow confirmed, turn on connected equipment. Failure to supply water to equipment may cause serious damage. 11. Record filter change on the service log. 4

Replacement Parts for Product Preservers Anti-Scale System Drawing ID # Description 1 Housing, w/pr 1a O-Ring 2 Valve, /4" FxM Ball Bracket, Single Housing 4 Screw 5 Pressure Relief Button Replacement Filter Cartridge 6 SM1.0L-RM P/N 261-00 LG1.5L-RM P/N 261-001 2 4 4X inlet IN outlet 5 OUT 6 1 1a 5

Limited Warranty Company warrants its Product Preservers Anti-Scale System as follows: The Product Preservers cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original shipment. Product Preservers filter cartridges are warranted for performance for a period of one year from the date of original installation when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual. Conditions 1. The Product Preservers system must be installed in applications with municipally supplied water adhering to EPA guidelines. 2. Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation.. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply. 4. Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications. 5. Water supply must not exceed 2.0 PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required. (Please contact your water treatment specialist.) 6. Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty. 7. Defective parts are subject to inspection by the company or any authorized representative before final commitment of warranty adjustment is made. 8. The company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then current production. Limitations Our obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Our obligation under this warranty with respect to the Product Preservers media will be limited to furnishing a replacement for the media within two years from date of original installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under Specifications, is not covered by this warranty. THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY A. O. SMITH WATER HEATERS WITH RESPECT TO THE PRODUCT. A. O. SMITH WATER HEATERS MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. A. O. SMITH WATER HEATERS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product. Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE. CALIFORNIA PROPOSITION 65 WARNING WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. (California law requires this warning to be given to customers in the State of California) USA: 500 Tennessee Waltz Parkway, Ashland City, TN 7015 4/19/1