Protect your people, your productivity and your bottom line.

Similar documents
FA L L P R O T E C T I O N P L A N N I N

FALL ARREST TETHER TRACK RIGID RAIL ANCHOR SYSTEMS DESIGN:

Fall Protection. 29 CFR Appendix C 29 CFR 1926 Subpart M

workplace fatalities involving falls to a lower level. Fall related fatalities make up 16% of workplace fatalities

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

??????? is committed to providing a safe work environment for its employees and preventing occupational injuries due to falls.

What standards apply to rooftop fall protections systems?

Fall Protection ABC s

SECTION FACILITY FALL PROTECTION PART I - GENERAL

Region: USA Language: EN Number : TB0031 Revision : B. Total Page: 3 Page n : 1 First Issue: 10/2014 Rev. Date: 10/08/2014

Occupational Protective Equipment

Know Your ABCs FALL PROTECTION GUIDE

Patrick Harel Ph

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

Department of Facilities Management. Occupational Health and Safety. Fall Protection Program

ARKANSAS TECH UNIVERSITY FACILITIES MANAGMENT HEALTH AND SAFETY MANUAL

Fall Protection Training

Competent Person - Fall Protection Presented by Turner Safety- your instructor is Steve Turner

New Mexico Institute of Mining & Technology. Fall Protection Program

Risk Control at United Fire Group

Walking-Working Surfaces Fall Protection Program

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

Fall Protection Refresher Orientation. Fall Protection Refresher Orientation 1

Fall Protection. Fall Prevention. vs. Sam Carbis Solutions Group. Solutions for Workplace Safety

Fall Protection 4/7/16

TRAVSMART permanent single-cable horizontal lifeline system

Product Name: Hold Me Rope Anchor

Progressive Safety Services LLC

Subparts D and I Walking-Working Surfaces & Personal Protective Equipment Final Rule

2.2. Anchorage Point A secure point of attachment for Lifelines, lanyards or deceleration devices.

At the end of this presentation you should know the difference between fall prevention, fall restraint, and fall arrest.

Reviewed: New Effective: 5/18/12 Supersedes: New Preparer: Owner: Approver: Team Member, Occupational Safety Industrial Hygiene

Applying Construction Fall Protection Concepts to General Industry

Operator's Manual Supplement

FALL PROTECTION

Walking-Working Surfaces and Fall Protection Standards Update. OSHA General Industry

SAFETY 101: FALL PROTECTION: REDUCING FALLS DURING RESIDENTIAL CONSTRUCTION: RE-ROOFING FACT SHEET

Update 29 CFR Subparts D & I

Application Showcase LIFE MATTERS TM

User Instructions 1790 Rail Anchor

Product Name: Edge Angel SRL

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

Product Name: Beamer Trolley Anchor

1.0 Scope and Application

Are You OSHA Compliant? Browse Our Products Specifically For Compliance With The Updated Walking-Working Surfaces and Fall Protection Standard.

Product Name: Edge Series Web SRL

User Instruction Manual Fixed Beam Anchor

User Instructions 1789 Parapet Wall Anchor

OSHA s new walking working surfaces standards

Product Name: Bull Ring Anchor

8. Fall Protection Procedures WAC

Reliance Industries, LLC Operating instructions for the / Bolt-on D-Ring Anchorage. Model # 3071

Product Name: Angel Anchor

Product Name: Concrete Anchor Strap

Working at Heights Training Checklist (Ontario Version)

FREQUENTLY ASKED QUESTIONS ABOUT FALL PROTECTION

FALL PROTECTION PLAN

Product Name: O-Torque Beamer

Product Name: Non-Shock Lanyard

Fall Protection Resource Guide P AGE 1

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

Regulation Summary: Walking-Working Surfaces & Personal Protective Equipment (Fall Protection Systems); OSHA s Final Rule

FALL PROTECTION GUIDELINE

Centennial Fall Protection Work Plan _CP_11_20_en_A1

Product Name: Beamer Instruction Manual. Part #: 00110

Product Name: Internal Shock Lanyard

Fall Protection. Fall Protection

Fall Protection. OSHA Office of Training & Education

FALL PROTECTION PROGRAM (OHS-0010)

This subject outlines procedures to prevent accidents or injuries to you and others from inappropriate selection and use of fall protection equipment.

29 CFR 1926, Subpart M. Fall Protection Program Table of Contents

Fall Hazards, Anchor Points and Fall Clearances OSH-2 August 7, 0900

Section 16B. Fall Protection. Falls are the second leading cause of death in the workplace. Factors contributing to falling incidents:

Fall Protection Checklist. Guardrail System

RIGGERS SAFETY SAFETY IS IN THE DETAILS FULL LINE CATALOG

Product Name: 2-Way Standing Seam Roof Clamp

FALL PROTECTION PLAN July 2012

FALL PROTECTION (SAF-SPI-06)

Figure 1 - Parts Identification. Copyright 2002, DB Industries, Inc.

UNIVERSITY OF MINNESOTA University Health and Safety FALL PROTECTION PROGRAM

Fall Protection Program

Written Program. For. Fall Protection. <<Company Name>> <<911 Address>> <<City, state, zip code>>

Effective Date: 10-January Table of Contents

Product Name: Rope Grab

Doc No: FPP CARDINAL SURVEYS COMPANY. Safety Management System. Initial Revision Date: Version Revision No. 02 FALL PROTECTION

Part #: 42000; 42001; 42002; 42003; 42004; 42005; 42006; 42008

Product Name: Snappy Anchor

Safety Manual Page 1 of 15

User Instruction Manual Fixed Beam Anchor

Fall Protection Introduction

Title- Fall Protection Effective Date: 03 Jan 14 Revision-0

Health, Safety, Security and Environment

Figure 1 - Parts Identification

FALL PROTECTION LADDERS ACCESSWAYS

Product Name: Standing Seam Roof Clamp

Fall Protection Guidelines. Individual Unit Function: Safety Procedure No.: SOP-0111 Page: 1 of 13. Preparer: Owner: Approver: Safety Safety Safety

The content of this resource has been generously provided by the AGC Houston, the Associated General Contractors of America.

Reporting, Recording & more Walking Working Surfaces Local Emphasis Program Your Questions

Product Name: 2-Way Standing Seam Roof Clamp. Instruction Manual. Part #: 10600

What is fall protection?

Transcription:

FALL PROTECTION TOOLKIT Protect your people, your productivity and your bottom line. What you will find inside: Fall protection basics OSHA and ANSI key requirements Tether Track product information Fall hazard assessment Tips for creating a fall protection plan

Your employees safety hangs in the balance. The facts are alarming. According to 2009 data compiled from the Bureau of Labor Statistics, 605 workers were killed, and an estimated 212,760 were seriously injured by falls to the same or lower level. Fall injuries constitute a considerable financial burden, as well. For example, Workers Compensation and medical costs associated with occupational fall incidents have been estimated at approxiamtely $70 billion annually in the United States. 1 Falls are among the most common causes of serious work-related injuries and deaths. 2 Worker safety is imperative, and developing and implementing a fall protection program not only prevents injuries, but could save lives as well. In addition, regulatory agencies have increased fines for noncompliance with fall protection standards. While there are a number of reasons why many companies are not meeting today s requirements for fall protection, the fact remains that employers have a legal and moral obligation to protect their people. Fall protection 101 Complying with today s workplace health and safety requirements is easier said than done. Which rules and standards apply to you? What s recommended and what s required? Before you can even start to develop a Fall Protection Plan you need to determine your company s legal obligations. A good starting point is to visit the Fall Protection section of the OSHA website: www.osha.gov/sltc/fallprotection. Common causes of workplace falls: Limited or no training Incorrect equipment Incorrectly calculated total fall distances and clearance Damaged equipment Worker fatigue Environmental conditions Situational awareness Fall protection by the code. What OSHA requires. Under Title 29 of the Code of Federal Regulations (29 CFR), the Occupational Health & Safety Act (OSHA) assures and enforces safe and healthful working conditions for general industry, construction and maritime trades. Employers have the duty of providing their workers with a place of employment free from recognized safety and health hazards. OSHA enforces regulation 1926, Subpart M for construction and regulation 1910, Subparts D and F for general industry, which require fall protection be provided at: 4' in general industry 5' in shipyards 6' in the construction industry 8' in longshoring operations Any height, when working over dangerous equipment and machinery, regardless of the fall distance. These regulations are legislation and must be followed under penalty of law. To avoid potential fines and citations, be sure to carefully assess your workplace environment and potential fall hazards. What ANSI recommends. In addition to federal regulations, there are voluntary consensus standards regarding fall protection set forth by the American National Standards Institute (ANSI) and Canadian Standards Association (CSA). ANSI and CSA specify product performance and testing criteria for personal fall arrest equipment. While not enforceable by law, these standards typically should be adhered to, as they are often adopted by OSHA or other regulatory agencies. ANSI Standards can become mandatory by Incorporation by Reference ; when an OSHA standard cites the ANSI standard for compliance; or when the General Duty clause is cited which requires employers to keep the workplace free from recognized hazards. ANSI issues the nationally recognized fall protection code ANSI Z359. 1 CDC Reference: NSC (2002) Report on injuries in America 2002. Itasca, IL: National Safety Council. 2 www.osha.gov/sltc/fallprotection

Do you need fall protection? An all-inclusive fall protection program begins with the ability to identify all fall hazards in your workplace. As a general rule, when someone is working from a height greater than four feet (1.2 m), a fall hazard exists and must be addressed in order to prevent workrelated injuries and avoid OSHA fines. Once a fall hazard has been identified, you typically have two options: 1) Eliminate the hazard altogether, or 2) Provide protection against it. In some cases, it is possible to eliminate a fall hazard, typically known as engineering out the hazard, simply by changing the working environment, processes and procedures. If this is not possible, fall prevention should be the next consideration. Common fall prevention methods include installing guardrails, scaffolds, handrails or barriers. Change work procedures or redesign your environment. ELIMINATE Move work to ground level. Deploy a fall protection system. PREVENT Work in a guarded area, utilizing products such as handrails, safety gates, guardrails and rooftop railings. When passive fall protection solutions such as elimination or prevention are not practical, personal fall protection equipment, such as harnesses, lanyards and retractable lifelines can be used. Personal fall protection may consist of a restraint system to keep the worker from reaching an area where a fall hazard exists, or a personal fall arrest system that enables a worker to perform their duties from the height required, while tied off to the system. If a need for fall protection is determined, the next step is to carefully consider the four options illustrated here. RESTRAIN Restrain worker by fitting them in a harness with a tether attached. A fixed-length lanyard is then attached to the D-ring on the harness, and then to a code-compliant anchorage system. ARREST Utilize a professionally engineered fall arrest system ideally one that is customdesigned for your specific work environment. Proper fall arrest includes three key components: anchorage, body harness, and connecting device.

Components of a fall arrest system. 1 2 3 ANCHORAGE: A secure point of attachment for lifelines, lanyards or deceleration devices; commonly referred to as a tie-off point. ANSI Z359 further defines anchorage as a fixed structural component such as a beam, girder, column or floor that can support the forces exerted in arresting a fall. CONNECTING DEVICE: A device used to link the body support component of the system to the anchorage connector, such as a shock-absorbing lanyard or self-retracting lanyard (SRL). BODY HARNESS: Provides a connection point on the worker to distribute the forces evenly across the body in the event of a fall. A full body harness is a body support device that distributes fall arrest forces across the shoulders, thighs, and pelvis and has a center back fall arrest attachment, typically a D-ring, for connection to the fall arrest connecting device.

The benefits of rigid rail fall arrest systems. While its name might imply otherwise, rigid rail systems are the most flexible forms of fall arrest. Ideal for environments where there is limited clearance between the working level and lower level or obstruction, these systems provide a shorter free-fall distance and a reduced risk of secondary injury due to impacts during the free fall or sudden deceleration. Rigid rail fall arrest systems are the perfect solution for permanent applications and can easily be customized to fit every situation. Tether Track Rigid Rail Fall Arrest Systems, A Class Above traditional wire rope. LESS FALL CLEARANCE DISTANCE Wire rope systems require additional fall clearance due to the initial sag of the wire. The dynamic sag, or the stretch of the rope during a fall, adds to this distance. A Tether Track Rigid Rail Fall Arrest System stops the fall sooner by eliminating any sag, stopping the fall in a much shorter distance than wire rope. REDUCED RISK OF SWING FALL INJURIES Injuries occurring after the fall, such as swinging into obstacles, are minimized with a rigid rail fall arrest system, which stays firm and minimizes the total fall distance. When a worker falls on a wire rope system, the wire s sag will make the trolley slide to the center of the nearest two supports, creating a risk for the worker to collide with nearby obstacles after a fall. LONGER DISTANCES BETWEEN SUPPORTS A rigid rail fall arrest system allows for longer distances between supports, reducing both material and installation costs. Tether Track Rigid Rail Fall Arrest Systems provide shorter free-fall distances, reduced risk of secondary fall injuries such as swinging into obstacles, and no negative impact on a second worker in the event of a fall. SAFER WORK FOR MULTIPLE WORKERS When a worker falls on a wire rope system, any slack on the wire is eliminated. The result could be a sudden pull on the rope that could have a jarring effect on other workers on the same system. Rigid rail fall arrest systems provide uninterrupted protection for additional workers on the same system. In the event of one worker s fall, the rigid rail system will not bend or deflect like a wire rope system, allowing additional workers to continue to move freely and safely. AFTER A FALL The worker can continue use of a rigid rail fall arrest system after a visual inspection. A wire rope system must be replaced and recertified by a qualified engineer. Wire rope systems can create hazardous situations due to the dynamic sag of the wire after a fall.

Getting your safety on the right track. Gorbel a leader in overhead material handling offers one of the most complete lines of rigid rail fall arrest systems available today. Featuring an enclosed track design, exclusively engineered for easy movement, Tether Track Systems provide the highest degree of mobility and safety, while reducing the risk of injury in elevated work environments. Designed by qualified engineers, Tether Track systems are available in multiple configurations, including various track profiles and support center distances, and meet the OSHA 1926 Subpart M Construction Standard, as well as the ANSI Z359 Fall Protection Code. The safest solution for virtually every environment. Engineered for easy movement, all Tether Track systems can be designed to accommodate multiple workers, utilizing dual bypassing track that allows them to maneuver around each other without disconnecting. Choose the configuration that best meets the needs of your environment: CEILING MOUNTED MONORAIL SYSTEMS Provide mobility along a single axis for applications when workers need to travel in a straight line Curved track sections available Variety of hanger options available to accommodate various building structures Unlimited monorail lengths with up to 50'* between supports CEILING MOUNTED MONORAIL FREE STANDING MONORAIL SYSTEMS Provide free standing support when building structure is inadequate for ceiling mounted applications Available in free standing cantilevered or goal post designs Cantilevered design allows for fewer support columns and accommodates headroom constraints Goal post design can be bolted directly into concrete floor, reducing the need for costly foundations Standard support centers from 7' to 35', and up to 50'* custom designed FREE STANDING MONORAIL *Dual trussed track only

BRIDGE BRIDGE SYSTEMS Consist of two runways and a traveling bridge for maximum coverage within a rectangular work area Lightweight aluminum bridge follows the worker, remaining directly overhead Available in ceiling mounted or free standing designs Plain or trussed track runways based on support center requirement Multiple bridges can accommodate several workers when properly zoned Unlimited runway lengths, with up to 30' bridge spans SWING ARM SWING ARM SYSTEMS Provide circular or semicircular fall protection with a compact footprint Versatile and adaptable; swing arm can be moved out of the way when not in use Wall mounted, column mounted or free standing designs Available in wall cantilever or wall bracket configurations, depending on headroom constraints Infinitely variable friction brake or motorized rotation available Standard arm lengths from 8' to 30', custom spans available upon request FOLD AWAY FOLD AWAY SYSTEMS Deploy as needed, then fold away when done Perfect for work cells requiring access to overhead cranes, when floor space is limited or when infrequent fall protection is necessary Wall mounted, column mounted or free standing designs Available in wall cantilever or wall bracket configurations, depending on headroom constraints Infinitely variable friction brake or motorized rotation available Unlimited lengths with up to 50' between supports SINGLE POLE SYSTEMS Space-saving design allows for installation in areas where there is minimal floor space or limited room for foundations Utilizes only one free standing support with one single foundation Standard track lengths up to 53' SINGLE POLE

Fall Hazard Assessment Checklist Use this checklist to determine if you require fall protection. Work is performed: indoors outdoors Identification of fall hazards (check boxes): Working surfaces at elevations of: 4' 5' 6' 8' Plus Unprotected sides or edges Leading edges Holes Ramp, runways and other walkways Excavations Dangerous equipment Wall openings Other Type of surface Frequency of task Task requires: vertical movement horizontal movement Number of workers exposed to a fall hazard Approximate distance from the surface to lower levels Can the fall hazard be eliminated or prevented by: Process change? Working in a guarded area, utilizing guardrails or gates? Using a fall restraint system? If you answered no to all of these questions, an engineered fall arrest system is required. If so, please answer the following two questions: Are there overhead obstructions? Are there floor obstructions? Yes, I do need a fall arrest system. Now what? Once you have determined a need for fall arrest system, the first thing you should do is contact Gorbel a recognized leader in overhead materials handling and fall arrest systems. Our engineers and fall protection trainers have the expertise to match your needs. Available in multiple configurations, including various track profiles and support center distances, fall protection systems can be easily customized to fit every budget and application. The next step is to add fall protection to your company s overall health and safety plan. A written site-specific program should be developed, including detailed work procedures to protect your employees. The fall protection portion of your plan should state what fall protection measures are to be used, how they are to be used, a rescue plan, as well as the individual responsible for overall supervision and training. For more information, visit www.gorbel.com or call 800-821-0086 What are the necessary lengths (how many supports?) What is the necessary height? 2012 Gorbel Inc. All Rights Reserved.