TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Similar documents
Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Pressure Regulators. Operating Instructions. Instrumentation

ERNG-X TESCOM Product Manual

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

1805 Series Relief Valves

64 Series Pressure Reducing Regulators

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Types 749B and R130 Changeover Manifolds

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

MEGR-1627 Instruction Manual

ER3000 Explosion Proof Manual

Type R622 Pressure Reducing Regulator

1305 Series Pressure Reducing Regulators

Types S100K and S102K Pressure Regulators

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

1805 Series Relief Valves

MEGR-1912 Instruction Manual

1301 Series High-Pressure Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

T208VR Series Tank Blanketing Vacuum Regulator

INSTRUCTIONS FOR MODEL TSC LOW DELIVERY PRESSURE GAS REGULATORS

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Temperature Controllers

623 Series Dome Load Regulators

RB Series Regulating System

INSTRUCTIONS FOR SINGLE STAGE LECTURE BOTTLE REGULATORS

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Type CT88 Backpressure Regulator

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

INSTRUCTIONS FOR MODELS APC & APG HIGH PURITY, CORROSIVE GAS REGULATORS

LRS(H)4 Pressure-Reducing Regulator User Manual

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve

Oxygen Usage Best Practice Guide

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

RD(H)20/25 Pressure-Reducing Regulator User Manual

Operation Manual Piston Sensed Gas Pressure Regulators

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Y692VB Series Vacuum Breaker

Type EZH Relief or Backpressure Regulator

OPERATING AND MAINTENANCE MANUAL

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

627 Series Pressure Reducing Regulators

Petro-Chemical & Analyzer Sampling Systems

CP200 Series Commercial / Industrial Pressure- Loaded Pressure Reducing Regulator

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

OPERATION MANUAL NTF-15

1200B2 Series Service Regulators. Instruction Manual

Fisher DVI Desuperheater Venturi Inline

Protocol Switchover Station

Type FEQ Slam-Shut Valve

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

OPERATION MANUAL NTF-60 Plus

Float Operated Level Controllers

Manual Actuated Boiler Blowdown Valves

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

INSTRUCTIONS FOR FM4460N SERIES HIGH PRESSURE, METAL TUBE FLOWMETERS

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Petro-Chemical & Analyzer Sampling Systems

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

GILMONT ACCUCAL FLOWMETERS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

ACCU-PULSE Installation and Operation Instructions

Before using or working with the Grab n Go Heliox system, please read and understand the usage and safety instructions provided in this booklet.

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

Types ACE95 and ACE95Sr Tank Blanketing Valves

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

PURPOSE OF THE POLICY

2.0 INSTALLATION & SERVICE

T208 Series Tank Blanketing Vapor Recovery Regulators

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Fisher DSA Steam-Atomized Desuperheater

R122H, R222, R232A, and R232E Series Instruction Manual

Transcription:

Operations & Service Manual TESCOM 50-4X Series Safety, Installation & Start-Up Procedures Do not attempt to select, install, use or maintain this product until you have read and fully understood this manual.

50-4X Series Table of Contents Contents Section 1: Symbols.... 4 Section 2: Safety, Installation and Operations Precautions.... 4 2.1 Installation.... 6 2.2 Repair Service... 6 Section 3: Installation... 7 3.1 Introduction.... 7 3.2 Specifications.... 7 3.3 Installation Diagram.... 8 3.4 Installation.... 8 Section 4: Start-up Procedure... 10 Table of Contents 3

Section 1: Symbols 50-4X Series Section 1: Symbols Caution Paragraphs highlighted by the CAUTION icon contain information that must be followed to maintain a safe and successful operating environment. Paragraphs highlighted by the WARNING icon contain information about practices or circumstances that can lead to personal injury or death, property damage or economic loss. Section 2: Safety, Installation and Operations Precautions Do not attempt to select, install, use or maintain this regulator, valve or accessory until you have read and fully understand these instructions. Be sure this information reaches the operator and stays with the product after installation. Do not permit untrained persons to install, use or maintain this regulator, valve or accessory. Improper selection, improper installation, improper maintenance, misuse or abuse of regulators, valves or related accessories can cause death, serious injury and/or property damage. Oxygen service requires special expertise and knowledge of system design and material compatibility in order to minimize the potential for death, serious injury and/ or property damage. Possible consequences include but are not limited to: High velocity fluid (gas or liquid) discharge Parts ejected at high speed Contact with fluids that may be hot, cold, toxic or otherwise injurious Explosion or burning of the fluid Lines/hoses whipping dangerously Damage or destruction to other components or equipment in the system 4 Section 1: Symbols

50-4X Series Section 2: Safety, Installation and Operations Precautions Caution Safety Precautions 1. Inspect the regulator, valve and accessories before each use. 2. Never connect regulators, valves or accessories to a supply source having a pressure greater than the maximum rated pressure of the regulator, valve or accessory. 3. Refer to product label (model specific) for maximum inlet pressures. If this rated pressure cannot be found, contact your local TESCOM representative for the rated pressure prior to installation and use. Verify the designed pressure rating of all equipment (e.g., supply lines, fittings, connections, filters, valves, gauges, etc.) in your system. All must be capable of handling the supply and operating pressure. 4. Clearly establish flow direction of the fluid before installation of regulators, valves and accessories. It is the responsibility of the user to install the equipment in the correct direction. 5. Remove pressure from the system before tightening fittings, gauges or components. 6. Never turn regulator or valve body. Instead hold regulator or valve body and turn fitting nut. 7. If a regulator or valve leaks or malfunctions, take it out of service immediately. 8. Do not modify equipment or add attachments not approved by the manufacturer. 9. Apply pressure to the system gradually, avoiding a sudden surge of fluid or pressure shock to the equipment in the system. 10. Regulators are not shut-off devices. Install a pressure relief device downstream of the regulator to protect the process equipment from overpressure conditions. Shut off the supply pressure when the regulator is not in use. 11. Periodic inspection and scheduled maintenance of your equipment is required for continued safe operation. 12. The frequency of servicing is the responsibility of the user based on the application. Positive seal/tied diaphragm regulators require the downstream pressure vented before turning the hand knob counterclockwise to reduce the outlet pressure. Damage may occur to the regulator if this procedure is not followed. 13. Never allow problems or lack of maintenance to go unreported. 14. Read and follow precautions on compressed gas cylinder labels. 15. It is important that you analyze all aspects of your application and review all available information concerning the product or system. Obtain, read and understand the Material Safety Data Sheet (MSDS) for each fluid used in your system. 16. Never use materials for regulators, valves or accessories that are not compatible with the fluids being used. 17. Users must test components for material compatibility with the system operating conditions prior to use in the system. 18. Vent fluids to a safe environment and in an area away from employees. Be sure that venting and disposal methods are in accordance with Federal, State and Local requirements. Locate and construct vent lines to prevent condensation or gas accumulation. Make sure the vent outlet is not obstructed by rain, snow, ice, vegetation, insects, birds, etc. Do not interconnect vent lines; use separate lines if more than one vent is needed. Section 2: Safety, Installation and Operations Precautions 5

Section 2: Safety, Installation and Operations Precautions 50-4X Series 19. Do not locate regulators, valves or accessories controlling flammable fluids near open flames or any other source of ignition. 20. Some fluids when burning do not exhibit a visible flame. Use extreme caution when inspecting and/or servicing systems using flammable fluids to avoid death or serious injury to employees. Provide a device to warn employees of these dangerous conditions. 21. Many gases can cause suffocation. Make certain the area is well ventilated. Provide a device to warn employees of lack of Oxygen. 22. Never use oil or grease on these regulators, valves or accessories. Oil and grease are easily ignited and may combine violently with some fluids under pressure. 23. Have emergency equipment in the area if toxic or flammable fluids are used. 24. Upstream filters are recommended for use with all fluids. 25. Do not bleed system by loosening fittings. 26. Prevent icing of the equipment by removing excess moisture from the gas. 27. Always use proper thread lubricants and sealants on tapered pipe threads. 2.1 Installation Caution Do not open packaging until ready for installation or in a clean environment. Product is cleaned in accordance with CGA 4.1 and ASTM G93, Verification Type 1, Test 1 and Test 2. With periodic verification of cleaning process to MIL-STD-1330D. Make sure that the components and materials used in the fluid handling system are compatible with the fluid and have the proper pressure rating. Failure to do so can result in death, serious injury and/or property damage. Inspect the regulator, valve and accessories for physical damage and contamination. Do not connect the regulator, valve or accessory if you detect oil, grease or damaged parts. If the regulator, valve or accessory is damaged, contact your local TESCOM representative to have the regulator cleaned or repaired. 2.2 Repair Service If a regulator or valve leaks or malfunctions, take it out of service immediately. You must have instructions before doing any maintenance. Do not make any repairs you do not understand. Have qualified personnel make repairs. Return any equipment in need of service to your equipment supplier for evaluation and prompt service. Equipment is restored to the original factory performance specifications, if repairable. There are flat fee repair charges for each standard model. The original equipment warranty applies after a complete overhaul. 6 Section 2: Safety, Installation and Operations Precautions

50-4X Series Section 3: Installation Caution Proper Component Selection 1. Consider the total system design when selecting a component for use in a system. 2. The user is responsible for assuring all safety and requirements of the application are met through his/her own analysis and testing. 3. TESCOM may suggest material for use with specific media upon request. Suggestions are based on technical compatibility resources through associations and manufacturers. TESCOM does NOT guarantee materials to be compatible with specific media THIS IS THE RESPONSIBILITY OF THE USER! 4. Component function, adequate ratings, proper installation, operation and maintenance are the responsibilities of the system user. Do not modify equipment or add attachments not approved by the manufacturer. Failure to do so can result in death, serious injury and/or property damage. ASSEMBLY/INSTALLATION DRAWINGS and BILLS OF MATERIAL drawings and parts lists for your product may be obtained by contacting TESCOM. Tescom will provide these by email, fax or mail. Your local TESCOM representative can provide additional assistance. Be sure to have your complete model number ready. Section 3: Installation 3.1 Introduction 50-4X Series pressure reducing regulators are specifically designed for extended life operation in high pressure hydraulic applications. The 50-4X Series is designed with an integrated bypass valve which controls large variations in flow rates at pressures up to 20,000 psig / 1379 bar. Applications include hydraulic power units for production, wellhead control panels (WHCP) and intervention work over control systems (IWOCS), where start-up requires high flow rates at large differentials and operate at high pressures with precise control. 3.2 Specifications Maximum Inlet Pressure: 10,000, 15,000 and 20,000 psig / 690, 1034 and 1379 bar Outlet Pressure: 9000-20,000, 8000-15,000, 6000-15,000, 4000-10,000, 2000-6000, 2000-4000, 1700-2500 psig 621-1379, 552-1034, 414-1034, 276-690, 138-414, 138-276, 117-172 bar Operating Temperature: -15 F to 165 F / -26 C to 73 C Flow Capacity: C v = 0.12 (Control Regulator) C v = 1.9 (Integrated Bypass) Weight (approximate)*: 50-4000: 15 lbs / 6.8 kg 50-4100: 20 lbs / 9.1 kg 50-4200: 20 lbs / 9.1 kg * Air loaded versions will have an additional approx. 10 lbs / 4.5 kg to account for the actuator. Section 3: Installation 7

Section 3: Installation 50-4X Series 3.3 Installation Diagram Letter call-outs are referenced in the Installation and Start-Up Procedures section of this manual. A F 50-4X SERIES B G C 15,000 psig 6000 psig INLET OUTLET VALVE VALVE VENT LINE D E Manual Bypass (E) Configurations ONLY: Hex Size = 3/4 inch Torque Range = 38 to 43 FT-LBS 3.4 Installation Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion, fire and/or chemical contamination causing property damage and personal injury or death. TESCOM regulators must be installed, operated and maintained in accordance with federal, state and local codes, rules and regulations. If the regulator vents gas or a leak develops in the system, service to the unit may be required. Failure to correct trouble could result in a hazardous condition. Installation, operation and maintenance procedures performed by unqualified personnel may result in improper adjustment and unsafe operation. Either condition may result in equipment damage or personal injury. Call qualified personnel when installing, operating and maintaining the 50-4X Series regulator. 8 Section 3: Installation

50-4X Series Section 3: Installation Metering valves should not be used to isolate the pressure reducing regulator. It is strongly recommended that block and bleed valves be used to properly isolate the regulator from the rest of the system. Failure to due so could result in personal injury, equipment damage or leakage due to escaping fluid. Confirm with gauges that there is zero pressure in the system prior to installation: Note: Refer to the Installation Diagram for additional information. 1. Confirm both the inlet (A) and outlet (C) block and bleed valves are closed prior to installation. 2. Install the regulator with inlet port connected to the supply or inlet piping of the system and connect the outlet port to the downstream piping in the system. 3. Connect the vent port of the regulator to the vent line (D) (return line to reservoir). There should be no restrictions in the vent line between the regulator and reservoir that would allow for the buildup of pressure. Check valves should be used in the vent line if it is possible for pressure to be introduced by another section of the system. 4. Confirm all pipe fittings are torqued to manufacturer s recommended rating. Personal injury, equipment damage or leakage due to escaping accumulated fluid or bursting of pressure-containing parts may result if this regulator is: Over-pressured Used with incompatible process fluid Installed where service conditions could exceed the limits given in the specifications section and marked on the regulator itself. Where conditions exceed any ratings of adjacent piping or piping connections. To avoid such injury or damage, provide pressure-relieving or pressure-limiting devices to prevent service conditions from exceeding those limits. Section 3: Installation 9

Section 4: Start-up Procedure 50-4X Series Section 4: Start-up Procedure To avoid possible personal injury, equipment damage or leakage due to escaping fluid, make certain the regulator is installed as instructed in the Installation section. Pressure gauges must always be used to monitor downstream pressure during Start-up. Note: For airload units follow the same process except instead of adjusting the handknob adjust the pressure on the airloader appropriately. Note: Refer to the Installation Diagram for additional information. Page 8. 1. Prior to opening the supply block valve (A), rotate the hand knob of the regulator (B) clockwise until it stops turning. This will verify the regulator (B) is set at its maximum setpoint. 2. Leave the inlet (A) and outlet (C) block and bleed valves surrounding the regulator closed and pressurize the supply/inlet side of the system. 3. Slowly open the inlet block valve (A) to apply pressure to the inlet of the 50-4X Series regulator (B). 4. Verify the regulator s supply pressure (F). 5. Verify the regulator s outlet pressure (G) is stable. If there is steady leakage, remove regulator for inspection and repair. 6. Check the vent line (D) for any sign of steady leakage. If leakage occurs remove regulator for inspection and repair. 7. Turn the hand knob of the regulator (B) counterclockwise to decrease outlet pressure to below the desired outlet pressure setting, making sure not to go below the bypass operating range. Pressure will be vented off through the vent return line (D) as the pressure setting is adjusted to a lower setpoint. Reference product data sheet for bypass operating range. 8. Turn the hand knob clockwise to increase outlet pressure to the desired outlet pressure setting. 9. Verify pressure is stable (G) (not increasing or decreasing). 10. Fully open outlet valve (C) to fill downstream volume. Note: If the desired control pressure is below the minimum of the regulator outlet pressure range, the manual bypass version is required and it must be set in the deactivated position. To deactivate the bypass valve (E), first remove all pressure from the inlet and outlet of the regulator. Then remove the protective cover on the manual override bypass cap and turn the external 3/4 inch hex clockwise until a torque of 38 to 43 ft-lbs is reached. At this point the bypass valve is now deactivated and only the control regulator is in operation. When adjusting the control regulator outlet setpoint be aware pressure will be vented off as regulator s outlet pressure setting is adjusted in the decreasing direction. The specified operating range of the bypass valve while active can be referenced on the product data sheet. 10 Section 4: Start-up Procedure

50-4X Series Section 4: Start-up Procedure Activated and Deactivated Bypass Valves ACTIVATED DEACTIVATED DEACTIVATE ACTIVATE Section 4: Start-up Procedure 11

Webadmin.Regulators@emerson.com Tescom.com Facebook.com/EmersonAutomationSolutions LinkedIn.com/company/emerson-automation-solutions Twitter.com/emr_automation Emerson Automation Solutions Americas Elk River, Minnesota 55330 USA T +1 800 447 1250 +1 763 241 3238 Europe Selmsdorf 23923, Germany T +49 38823 31 0 Asia Pacific Singapore 128461, Singapore T +65 6770 8337 Middle East and Africa Dubai, United Arab Emirates T +971 4 811 8100 2015, 2018 Emerson Process Management Regulator Technologies, Inc. All rights reserved. 01/18. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. TESCOM is a mark owned by Tescom Corporation, a business of Emerson Automation Solutions. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.