UniCEM. Continuous Emissions Monitoring System

Similar documents
UltraCEM-PD. Indoor Panel/Wall Mount Utilising Dilution Technology Continuous Emissions Monitoring System

Thermo Scientific Model 146i Principle of Operation

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HumiSys HF High Flow RH Generator

Model EXAxt AV550G. Averaging Oxygen Analyzer

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

780S Ultra High Purity Series

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Columbus Instruments

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Autocalibration Systems For In Situ Oxygen Analyzers

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

BUBBLER CONTROL SYSTEM

Ultra High Purity Model 780S

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

BUBBLER CONTROL SYSTEM

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Pneumatic high-pressure controller Model CPC7000

EasyLine Continuous Gas Analyzers. So smart, they re simple

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Pro-V Multivariable Flowmeter

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

21700 Nordhoff St. Chatsworth, CA Phone

Technical Data Sheet MF010-O-LC

GasSense NDIR User Manual

Instruction Bulletin Addendum For Pressure-Balanced In Situ Oxygen Probes

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Autocalibration Systems for In Situ Oxygen Analyzers

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Title: Standard Operating Procedure for Sabio 2010 and 4010 Dilution Calibrator

Installing a Probe. Typical Installation

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Generating Calibration Gas Standards

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Pneumatic high-pressure controller Model CPC7000

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Instruction Manual. Biogas Analyzer InCa Bio 04

MODEL 400 CLD INSTRUCTION MANUAL

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

I/P Transducer Positioner Module

Best Practice Guide, Servomex 2700

The Ins and Outs of I/P Transducers

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Operation & Maintenance Manual GDS-68XP

FPG8601 Force Balanced Piston Gauge

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

ACV-10 Automatic Control Valve

Features. Description

Mass Flowmeters. Mass Flowmeters for Gases

LT GasAnalyzer beyond standards

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Aurora. Moisture Measurement for Industrial Gases. GE Measurement & Control

SM8200. SO2/NO In Situ Multi-Gas Analyzer

Datasheet: K-30 ASCII Sensor

Expert Hydrostatic Level Transmitters

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

AUTOMATIC HOSE TEST UNIT, TYPE SPU

CAPITAL CONTROLS SERIES NXT3000

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

Oxidation Stability of Gasoline and Aviation Fuels

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

California Analytical Instruments, Inc.

Over 20,000 Strain Gage Target flowmeters installed since 1952.

analytical bulk flow distance FLOW level pressure temperature industrial communication

Potter Nitrogen Generators

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

RAM 4021-DPX Operation Manual

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Oxygen & Binary Gas Measurement and Analysis

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT METHOD INSTRUMENTAL ANALYZER PROCEDURES FOR CONTINUOUS GASEOUS EMISSION SAMPLING

CONTROL VALVE TESTING

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

AMT-Ex Dewpoint Transmitter

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司


Transcription:

UniCEM Continuous Emissions Monitoring System

UniCEM Continuous Emissions Monitoring System The UniCEM system is an up to five channel field mount Continuous Emissions Monitoring System designed to continuously determine the concentration of O2, CO, CO2, SO2, and NOx in a flowing gaseous mixture. The UniCEM uses proven extractive monitoring technology, state of the art measurement detectors and modular Compact-PCI detector interface boards. Designed for process type applications (O2, Co, CO2, NOx, SO2,), the monitoring system uses proven sample handling techniques for reliable gas monitoring to assure accurate readings. The system also provides proven technology for monitoring by using time proven detector technologies, which can measure from low ppm levels to percent levels. Indoor Panel Mount UniCEM Outdoor Field Mount UniCEM NEMA 4X Box designed for Outdoor monitoring. A high cost shelter is not required.

UniCEM Features Compact PCI computer design for reliability and modular design Long life reference-method detectors Includes a web-based interface Integrated with UniDAS for emission reporting. Available in panel mounts and outdoor field mount configurations. Time proven high Accuracy/Sensitivity gas detectors utilized: Paramagnetic (O 2 ), GFC- IR (CO and CO 2 ), Chemiluminescent (NOx), GFC-UV (SO 2 ) An integrated web-based operator interface provides status, configuration and reporting from any connected computer. Small laptop can control the unit over a wireless network. Built in Data Acquisition and System Handling System - 40 CFR Part 60/75 compliant Easy to service front access components Independent Analysis and Sample conditioning panels allow maximum installation flexibility Heated Sample Line. Optional Industry standard robust sample conditioning components Optional Hazardous area Class I, Div. II option. Sample Conditioning/Probe Box The sample gas is extracted by a specially designed probe and is then conditioned by utilizing the UniCEM sample conditioning/probe Box. The box is located at the sampling location and consists of the following equipment. Housing The housing is completely piped and wired and is accessible to customer via bulkhead and terminal block termination points. All sample lines, fittings and valving are Stainless Steel, Teflon and/or Polypropylene. Sample Box uses a Standard Compressor type Air Conditioner. The housing is also equipped with a state of the art Thermo Electric Air Conditioner. The Thermo Electric air conditioner is a compressor-less type and does not require periodic maintenance. The unit will both heat and cool which will allow the Sample Box to operate in any hot to cold environments

Cleaning The gas sample is cleaned with two levels of filtration: Primary filtration is performed at the probe tip by utilizing a 0.5 micron sintered filter. Secondary filtration occurs after the sample pump. Sample Drying The UniCEM provides a dry basis gas measurement. The reason is most regulatory agencies require measurements to be recorded as dry. The UniCEM dries the sample gas by utilizing a dual pass thermo electric chiller. The chiller cools the sample gas and is allowed to continue through the system. The sample is then passed through a membrane-type high efficiency permeation dryer that will dry the sample to a minus 30 C dew point. This extreme drying process eliminates the requirement for heated sample line. Sample Pump The pump is a positive displacement type pump that uses a moving diaphragm. All wetted parts are 316 Stainless Steel and/or Teflon. In normal operation the pressure at the pump outlet is set between 5-10 psi. Wiring All termination points for incoming or outgoing signals are provided on terminal strips or plugs. Probe A specially designed probe extracts sample gas from the stack. The probe is constructed of 316 Stainless Steel. The probe tip is fitted with a sintered filter and the filter can be easily changed and serviced. Calibration fittings are provided so that system complies with EPA guidelines for auto calibration as outlined in US EPA 40 CFR Part 60 regulations. The customer must provide the instrument air supply. The sample probe has optional 4" and 6" flange adaptors available and is available in a variety of probe lengths. Measurement Analysis System The UniCEM design includes an Analysis box which accommodates all of the measurement detectors and computer components. The box can be located at the sampling location or up to 300' away from the sample handling box for user installation flexibility. This enclosure is rated NEMA 4X and can be mounted directly in the outside environment. Sun and rain shields are mandatory to maintain proper performance specifications. Vents and Drains All vented gases or drained fluids are vented through bulkhead unions. Customer may route them to a sump. If the housing is located in a well-ventilated area, the gases can be vented to the atmosphere.

O 2 Detector (Paramagnetic) The determination of oxygen is based on the measurement of the magnetic susceptibility of the sample gas. Oxygen is strongly paramagnetic, while other common gases are not. The detector used is compact, has fast response and a wide dynamic range. The long life cell is corrosion resistant and may be easily cleaned. It has rugged self-tensioning suspension and is of welded Non-Glued construction. Standard range is 0-25%. CO and CO 2 Detectors (NDIR-GFC) The non-dispersive infrared method (Single beam double wave) is based on the principle of absorption of infrared radiation by the sample gas being measured. The gas specific wavelengths of the absorption bands characterize the type of gas while the strength of the absorption gives a measure of the concentration of the gas component being measured. A pair of gas filled cuvettes is mounted on a rotating disc. The reference cuvette is filled with a sample of the gas to be measured and the measure cuvette with nitrogen. This technique is known as gas filter correlation. They pass through the beam of light alternately. The difference in absorbance is measured by the detector and provides a direct output of the gas concentration. CO Standard dual range capability between 3000-1000ppm is available. 1 percent and 10 percent Ranges are also available. CO2 Standard Ranges of 25 percent, 50 percent and 100 percent. NOx (Chemiluminescence) The NOx detector consists of an ozone generator, chemiluminescence reaction chamber and a photomultiplier tube detector. The reaction chamber operates at atmospheric pressure, thus eliminating the need for the bulky vacuum pump found in other chemiluminescence instruments. The reaction between Ozone and Nitric Oxide is used to determine the presence of Oxides of Nitrogen (NOx) in a sample gas. Nitric Oxide and Ozone readily react to form nitrogen dioxide in an electrically excited state. The excited NO2 immediately reverts to the ground state, emitting photons. The light intensity is measured by the thermoelectric cooler controlled photo detector. Standard dual range capability between 100 to 3000ppm are available. SO 2 Detector (UV-GFC) The absorption measurement in the UV spectral range is based on the same principle as the IRGFC measurement. The standard range capability is between 100 to 2000 ppm are available. Accurate Detector Temperature Control Box All measurement detectors are located in a box design equipped with a compact and highly efficient environmentally sealed thermo electric controlled system. The enclosure is kept at a constant temperature enabling the analyzer to produce extremely accurate measurement results due to the fact that the temperature control is stable and at ideal temperature.

Automatic Calibration To minimize the effect of long term zero and span drift in each analyzer detector, the Compact-PCI system controller periodically initiates a calibration cycle as specified by the user. This feature assures reliable, accurate data while minimizing the attention required by operating personnel. At adjustable intervals, the microprocessor will energies the appropriate valves which cause first zero, mid and then span gas to flow through each analyzer. When the analyzer readings stabilize, the PC Controller calculates the zero and span drift value for each detector. If a significant measurement deviation from the standard gas value exists, an alarm is generated which must be reset. UniCEM Laptop Display The UniCEM is provided with laptop computer which allows access to the UniCEM status and configuration. On UniDAS equipped UniCEMs, the laptop can also be used to generate reports. Wireless Option As an option the UniCEM can be equipped with a wireless network interface. The laptop can connect to the UniCEM at distances of up to 1000' away from the analysis enclosure. Computer System Controller/Data Acquisition System The Compact PCI controller is a standard off the shelf PC based platform and will perform all hardware control, as well as provide select data processing capability for the UniCEM. Both analog and digital inputs and outputs are provided, including data correction and average values. The computer system: Automatically calibrates each gas analyzer at selected time intervals to ensure accuracy and regulatory compliance. Automatically controls purge of the sample probe with instrument air. Provides system limit and failure alarms. Provides I/O digital and analog signal interfaces. Applies calibration correction factor for each analyzer output, data averaging for regulatory requirements (3 months data storage of 15 minute and 1 hour averages, 1 week storage of 1 minute averages), Applies O 2 diluent correction and stores data as separate value. Supports an array of communication mechanisms: RS-232/485, Ethernet, TCP/IP, ModBus, OPC, 4-20 ma Current Loops, USB. Uses an Intel processor with 512 MB RAM: USB Port and Monitor Port. Provides single button initiate to download data into excel format. Simple regulatory reports can then be tailored by the user.

Sample and Calibration Gas Distribution The gas and calibration gas samples will be controlled by a single Mass Flow Controller. The MFC shall control the sample gas and calibration gas sample gas flow very accurately. The use of an MFC allows for very high accuracy and reliable monitoring. The Analysis Panel is equipped with a 3 way universal solenoid that will accommodate the gas sample for either the normal stack gas sample or direct the calibration gases directly to the analyzers otherwise known as a local calibration. The UniCEM is equipped with a manifold with up to four two-way Normally Closed solenoid valves that will direct the customer supplied calibration gases into the system. The valves will be used for Zero, Mid and Span gas calibrations respectively. The panel is equipped with a gas vent line. The vent will be routed to a sump by customer. If the housing is located in a well ventilated area, the gases can be vented to the atmosphere. Otherwise they should be piped out of the room or building. The Chemiluminescent detector requires a continuous source of instrument air from customer. The enclosure is equipped with a bulkhead fitting for this connection. 1 Year Ownership Cost Comparison UniCEM (US$) Others (US$) O2, NOx and CO $50,000 $70,000 DAS cost (Part 60) $15,000 $30,000 Shelter cost (8'D X 8'W X 8'H) Annual shelter maintenance $0 $20,000 $0 $5,000 Shelter installation $0 $5,000 Peripheral installation costs $2,000 $10,000 Heated Sample Line (250') $0 $12,500 TOTALS $67,000 $152,500 Savings PER UniCEM $85,500 Equipment to be provided by others Calibration gas bottles Calibration gas regulators. Dual stage with CGA connector Instrument Air supply 85-125 VAC, 50-60Hz plant power supply Tubing between probe and sample handling panel Wiring trays for electrical interconnection wiring Sample ports for probe connection Mounting Hardware

Measurement Analysis System Specifications General Power: Universal Power Supply 85-125VAC, 50-60 Hz, + 10%, 500 Watts Maximum at Start Up. 250 Watts Nominal Microprocessor Board: Intel processor, 512MB RAM, Compact PCI architecture, Windows XP Embedded Platform Laptop: Intel or AMD processor, 512MB RAM 800 x 600 pixels, Windows OS LCD, TFT color, Wireless LAN Detectors//Number: NDIR-GFC (CO and CO 2 ), UV-GFC (SO 2 ), Paramagnetic (O 2 ), Electrochemical (O 2 ),Chemiluminscent (NOx), (THC) FID Up to five in one analyzer Mounting: Wall Mount Area Classification: General Purpose Compliance's: CSA (Pending) Ambient Temperature Range: -30 to 50 C. Relative Humidity: 99% Inputs/Outputs: Digital: Connectivity Protocols: RS-485 Serial Port. (Multi-Drop Network) RS-232 Serial Port. LAN, Ethernet 10/100/1000 -BaseT HTML (Web Browser) - Status, File transfer, Remote Control TCP/IP, HTTP ASCII String, Microsoft Shared drive FTP Logs download TELNET Server Analog: Analog Outputs: up to 8 isolated 4-20 ma dc, 500 ohms Max Load (O 2, CO, CO 2, SO 2, NOx and 3 spares) Analog Inputs: up to 8 (Typically; Flow, Opacity, MW, Fuel Flow) Digital: Outputs: up to 14 dry contact digital Outputs; maximum 110VAC @ 1 amp load. Typical; O 2, CO, CO 2, SO 2, and NOx limit exceed, data valid, in calibration, in maintenance, trouble alarm Digital Inputs: up to 8: (Typical Process on/off, Flame Detect, Shutdown or Initiate Cal, flow signals and Opacity signals). Interrogated with 5 VDC. Instrument Weight: 60 lbs Typical Size: 40 X 32 X 12 (H W D) Ranges: O 2 : 0-1 Selectable to 0-25% (1% increments) CO: 0-10 ppm Selectable to 100% (1 ppm increments) CO 2 : 0-5 ppm Selectable to 100% (1 ppm/% increments) NOx: 0-5 ppm Selectable to 10,000 ppm (1 ppm increments) SO 2 : 0-25 ppm Selectable to 2000 ppm (1 ppm increments) THC: 0-5 ppm Selectable to percent levels Sample Temperature: 0 C to 55 C Sample flow rate: 0.5 to 1.5 litres/min Warm Up Time: Max 25 minutes Sample Handling Box and Probe Specifications General Power: Universal Power Supply 85-125VAC, 50-60 Hz, + 10% 500 Watts Maximum at Start Up. 250 Watts Nominal Mounting: Wall Mount Area Classification: General Purpose Compliance's: CSA (Pending) Ambient Range Temperature: -300 to 500C Relative Humidity: 99% Instrument Weight: 80 lbs Typical Size: 24" x 24" x 12" (H W D) Stack Sample Moisture: Up to 30% max Sample Cooler: Thermo Electric type with dual pass Chiller. Max. Stack Temperature: Standard 14000F

Stack Pressure: Sample Flow Rate: Response Time: Probe Length: Probe Mounting Flange: Sample Pump: Instrument Air Requirements: Typical -5 to 15 inches H 2 O 500 to 2500cc/min 30 seconds/100' of Heated Sample line (1/4" tubing) 48" length 316 Stainless Steel Probe with.5 micron sintered filter. Optional 5' and 6' probes. Standard 4" 150# Raised Face (2 Hole Top). Shipped Equipped with Gasket 316 Stainless Steel diaphragm type Instrument grade air required. 15 SCFM @ 60-100 PSIG (30 seconds 2 times per day) Pressure Regulation by Customer Paramagnetic O 2 NDUV SO 2 /FID THC NDIR CO/CO 2 Chemiluminescent NOx Linearity < +/- 1% < +/- 1% < +/- 1% < +/- 1% (1) Zero Drift < +/- 1% /day < +/- 1% /day < +/- 1% /day < +/- 1% /day (1) Span Drift < +/- 1% /day < +/- 1% /day < +/- 1% /day < +/- 1% /day (1) Repeatability < +/- 1% < +/- 1% < +/- 1% < +/- 1%/day (1) Response Time (t 90 ) 10 < +/-t 90 < +/-15 30 <+/-t 90 < +/-45s 15s < +/-t 90 < +/30s 15s < +/-t 90 < +/-30s Influence of Ambient Temperature (-30 C to 50 C) - On Zero < +/-1% < +/-2% < +/-2% +/-2% - On Span < +/-1% < +/-2% < +/-2% +/-2% (1) 0-10 ppm NOx range is < +/-2%. Sample Menu Screens

UniCEM Vs. Insitu COMPETITIVE ANALYSIS Criteria UniCEM Insitu Comments Accuracy High Moderate Ambient Temp High Range 60ºC 55ºC Analytical Capabilities Excellent Poor Cost of Ownership Low Moderate Drift due to Ambient Temperature changes EPA 40 CFR Part 60 Reference Method Detectors None Yes Not listed No EPA Approval Yes No Ethernet TCP/IP communications Yes No The Chemiluminescent (Nox), NDUV (SO2) and NDIR (CO) will offer much greater accuracy and allow for lower range capability All detector and Electrical components are located in a temperature controlled enclosure which will assure longevity and accuracy The UniCEM utilizes multiple detectors in order to measure each specific gas constituent. Insitu type one detector methods are very unreliable and unstable when measuring more than one gas. The field mount design allows for extremely low installation costs and the robust design of the electronics and detectors enhanced by the internal climate control allow the UniCEM to operate for a very low cost for many years to come. This is very important due to the nature of most applications. The analyzer will see as much as 20 degree C temperature changes daily. This temperature change will not affect the UniCEM EPA specifically states that all certification tests must use chemiluminescent and NDIR technologies as the to certify all CEMS. This will be important due to the nature of discrepancies in measuring accuracy when using different than EPA specified detectors. UniCEM is approved for certification in an EPA 40 Part 60/75 application User can simply use off the shelf Microsoft standard PC and communication equipment. No special software or hardware required to communicate with the UniCEM Future Expansion Yes No Internal Data Storage 12 months None Maintenance Simple Complicated Modularity of the system allow users to add up to 5 gas measurements after installation. Important especially in territories where EPA requirements are constantly changing. This will eliminate the need to have a separate PLC to store back data. This also enables the user to quickly view any calibrations, alarms, measurements that occurred over the last 3 months. All service items are easy to replace without the removal of the analyzer from the stack Repeatability ±1% ±2% Equates to more reliable long term readings Two point stream switch option Yes No Variable Range selection Yes No Windows HTML interface Yes No Wireless Communications with Monitor Yes No The UniCEM can also accommodate 2 separate stacks simultaneously. Very efficient for SCR inlet and outlet applications Customer is able to change ranges on the fly without having to purchase vendor services or software. Customer can view UniCEM by utilizing a standard Microsoft Internet Explorer tool. User can simply use the standard pocket pc from their office to view or select menu functions. Saves time and money not having to climb the stack or drive/walk thru the plant. Data Acquisition System Built-in DAS Limited Optional DAS available On-board